Product Highlights BINDER Scientific with New Avantgarde.Line Products
Growth Storage 3 In vivo and In vitro cultures Sample storage Growth chambers with illumination KBW and KBWF series APT.line Advanced Preheating Technology Patented lighting system ensures uniform light distribution with height-adjustable cassettes and three lamp types to choose from, e.g. daylight lamps or Arabidopsis lamps Fast and precise steam humidification Integrated weekly programming capability in real-time ULTRA.GUARD TM -80 C Ultra low temperature freezers UF V series Motorized door latch for one-touch easy open and close Lowest noise level available in its class Low energy consumption Personalized access control through RFID technology (optional) Data logger with USB connection (standard) ~ 500 liters ~ 17.6 cu.ft. ~ 700 liters ~ 24.7 cu.ft. ~ 720 liters ~ 25.4 cu.ft. Range Fluctuation ±K Interface Alarm Safety Device Fan Fan with Speed Control Inner Glass Door Controller C T A + 7 C to 50 C 0.1 V/A 3.1 LED/Timer CB T A + 7 C to 60 C 0.1 RS422 V/A 3.1 Color Graphic Program CB T A + 7 C to 60 C 0.1 RS422 V/A 3.1 Color Graphic Program BD 9010-0177 T A + 5 C to 100 C 0.1 RS422 V 3.1 LCD/Timer Function/Ramp BF 9010-0244 T A + 5 C to 100 C 0.2 RS422 V 3.1 LCD/Timer Function/Ramp KB 9020-0167 -5 C to 100 C 0.1 RS422 V/A 3.1 LCD/Timer Function/program KT 4 C to 100 C 0.1 Ethernet V/A 3.1 Graphic Program KBW 9020-0172 0 C to 70 C 0.1 RS422 V/A 3.1 LCD/Timer Function/program KBWF 9020-0282 0 C to 70 C 0.5 RS422 V/A 3.1 Color Graphic Program UF V 9020-0234 1 9020-0238 2-80 C to -40 C RS422 V/A LCD/Constant temperature 1: 120 V version for UF V 500 = 9020-0235 2: 120 V version for UF V 700 = 9020-0239 3: Termperature range 0 to 100 C T A : Ambient A: Audible V: Visual FLUORA or Arabidopsis illumination options (KBW KBWF) BINDER PURE AQUA SERVICE (KBWF) Wide selection of racks and boxes (UF V) Various access ports (C CB BD BF KB KT KBW KBWF)
2 Growth Cell and tissue cultures Microbiology incubators C and CB series Validated and recognized 180 C hot air sterilization routine High relative humidity up to 95% Stable ph values thanks to drift-free IR sensor technology Condensation-free interior due to Permadry technology VENTAIR air jacket system ANTI.PLENUM Design Incubators BD, BF, KB and KT series APT.line Advanced Preheating Technology Adjustable fan speed Disinfection routine at 100 C Inner glass door: First look, then open Refrigerated incubator (KT series) with Peltier technology Refrigerated incubator (KB series) with compressor technology Product Certificate ~ 23 liters ~ 0.7 cu.ft. ~ 53 /56/60 liters ~ 2 cu.ft. ~ 115 liters ~ 4.1 cu.ft. ~ 160 liters ~ 5.4 cu.ft. ~ 170 liters ~ 5.9 cu.ft. ~ 220 liters ~ 7.9 cu.ft. ~ 240/260 liters ~ 8.5 cu.ft. ~ 400 liters ~ 14.3 cu.ft. incubator C UL 9040-0013 incubator CB UL 9040-0089 9040-0093 9040-0097 incubator O 2 control CB UL 9040-0091 9040-0095 9040-0099 Incubator gravity convection BD UL 9010-0189 9010-0324 9010-0326 9010-0330 9010-0176 Incubator forced convection BF UL 9010-0314 9010-0316 9010-0320 9010-0242 Refrigerated incubator KB UL 9020-0113 3 9020-0252 9020-0253 9020-0254 9020-0179 Refrigerated incubator KT UL 9020-0312 9020-0314 9020-0310 Growth chamber KBW 9020-0256 9020-0180 Growth chamber KBWF 9020-0281 Ultra low temperature freezer UF V UL Wide range of options Gas Tank Switch (C CB) Divided inner glass door (CB) Stacking adapter for thermal decoupled stacking of two incubators (C CB) Data Logger Kits (BD BF KB KBW KBWF)
4 Drying and tempering Drying and heat treatment Material testing Laboratory ovens ED, FD and FED series Uniform drying conditions due to APT.line Advanced Preheating Technology High standard according to DIN 12880 (27-point measurement) Large capacity reserves Fast heat up and recovery times Available with gravity or mechanical convection Material test chambers FP and M series Uniform drying conditions due to APT.line Advanced Preheating Technology High standard according to DIN 12880 (27-point measurement) High air exchange rate and large power reserves Fast heat up times Individual programming with digital controller (only M series) Product Certificate ~ 23 liters ~ 0.7 cu.ft. ~ 53/56 liters ~2 cu.ft. ~ 115 liters ~ 4.1 cu.ft. ~ 150 liters ~ 5.4 cu.ft. ~ 210 liters ~ 7.9 cu.ft. ~ 240/260 liters ~ 8.5 cu.ft. ~ 400 liters ~ 14.3 cu.ft. Drying oven with gravity convection ED UL 9010-0193 9010-0334 9010-0336 9010-0340 9010-0168 Drying oven with forced convection FD UL 9010-0196 9010-0304 9010-0306 9010-0310 Heating chamber with forced convection FED UL 9010-0296 9010-0294 9010-0300 9010-0217 Material test chamber with forced convection FP UL 9010-0175 9010-0262 9010-0264 9010-0266 test chamber M 9010-0201 9010-0202 9010-0203 9010-0204 Saftey drying oven FDL 9010-0292 Vacuum drying oven VD UL 9030-0035 9030-0036 9030-0037 Saftey vacuum drying oven VDL ATEX 9030-0038 9030-0039 9030-0040 Wide range of options Door with heated viewing window with interior lighting (ED FD FED FP M) Access ports with silicone plugs (ED FD FED FP M FDL) Reinforced Shelves (FD FED FP M) Data Logger Kits (ED FD FED FP M)
Drying and tempering 5 Safety drying Vacuum drying Safety drying ovens FDL series APT.line Advanced Preheating Technology Defined solvent quantity meets drying safety standards Meets EN 1539: Fresh air monitoring with automatic switchoff Safety class IP 33 Easy to replace fresh air filter Vacuum drying ovens VD and VDL series Maximum specimen protection with adjusted overshooting Direct heat transfer through thermal conducting plates Patented, flexible positioning of the expansion racks Accelerated drying process due to Cross-Flow Principle Ensures optimal work safety through its one-of-a-kind safety concept ~ 500 liters ~ 17.6 cu.ft. ~ 700 liters ~ 24.7 cu.ft. ~ 720 liters ~ 25.4 cu.ft. Range Fluctuation ±K Interface Alarm Safety Device Fan Fan with Speed Control Inner Glass Door Controller ED 9010-0169 T A + 15 C to 300 C 1a 0.3 RS422 V 2 LCD/Timer Function/Ramp FD T A + 10 C to 300 C a 0.3 V 2 LCD/Timer Function/Ramp FED 9010-0219 T A + 10 C to 300 C a 0.3 RS422 V 2 LCD/Timer Function/Ramp FP 9010-0268 T A + 5 C to 300 C a 0.3 RS422 V 2 LCD/Timer Function/program M 9010-0205 T A + 5 C to 300 C 0.3 RS422 V 2 Color Graphic Program FDL T A + 5 C to 300 C 0.3 RS422 V 2 LCD/Timer Function/Ramp VD T A + 15 C to 200 C 0.1 RS422 V 2 LCD/Timer Function/program VDL T A + 15 C to 200 C 0.1 RS422 V 2 LCD/Timer Function/program 1: range varies by unit size. a. ED, FD, FED and FP Avantgarde Units Range as listed Classic range 5 C to 300 C T A : Ambient A: Audible V: Visual measurement of the specimen (ED FD FED FP M FDL MDL VD VDL) Vacuum-tight access port into the device for measuring lines (VD VDL) Vacuum module with chemical membrane pump (VD VDL) Specimen temperature display with PT 100 sensor (ED FD FED FP M VD VDL)
6 Environmental simulation Constant climate testing Constant climate testing with illumination Constant climate chambers KBF Best uniformity due to APT.line Advanced Preheating Technology Use in-house water, tank or BINDER Pure Aqua water solution Vapor pressure humidification with fast response times Stability tests according to ICH guideline Q1A(R2) Documentation and software FDA compliant Constant climate chambers with illumination KBF P & KBF LQC ICH-Q1 B Option 2 compliant Synergy Light Uniform light over the entire usable space Light Quantum Control with accurate light valuation directly at the sample location Documentation and software FDA and GMP/GLP compliant Tap or tank automatic water and discharge management Product Certificate ~ 23 liters ~ 0.7 cu.ft. ~ 53 liters ~ 1.9 cu.ft. ~ 115 liters ~ 4.1 cu.ft. ~ 150 liters ~ 5.4 cu.ft. ~ 210 liters ~ 7.9 cu.ft. ~ 240 liters ~ 8.5 cu.ft. ~ 400 liters ~ 14.3 cu.ft. Constant climate chambers KBF UL 9020-0268 9020-0270 Constant climate chambers with ICH-compliant illumination Constant climate chambers with Light Quantum Control Constant climate chambers for stress testing KBF P UL 9020-0274 KBF LQC UL 9020-0278 KMF 9020-0307 9020-0308 Wide range of options BINDER PURE AQUA SERVICE water treatment system Data Logger Kits Validations and calibrations External water supply
40 30 20 10 0 300 250 200 150 100 50 Environmental simulation Documentation 7 Dynamic constant climate testing Process documentation APT-COM TM Constant climate chambers for stress testing KMF Best uniformity due to APT.line Advanced Preheating Technology Broad climate range up to 90 % RH Vapor pressure humidification with fast response times Use in-house water, tank or BINDER Pure Aqua water solution Powerful cooling system for safe operation up to T A 32 C Software: APT-COM TM DataControlSystem Performance potential in 3 classes: Basic, Standard, GLP Edition (FDA conform) Clear presentation of process data Unsurpassed process safety and security Guideline-compliant data security Time-saving documentation and presentation of results ~ 500 liters ~ 17.6 cu.ft. ~ 700 liters ~ 24.7 cu.ft. ~ 720 liters ~ 25.4 cu.ft. ~ 1020 liters ~ 36 cu.ft. Range Fluctuation ±K Interface Alarm Safety Device Fan Fan with Speed Control Inner Glass Door Controller KBF 9020-0272 9020-0315 0 C to 70 C 0.1 Ethernet V/A 3.1 Color Graphic Program KBF P 9020-0276 0 C to 70 C 0.2 Ethernet V/A 3.1 Color Graphic Program KBF LQC 9020-0280 0 C to 70 C 0.2 Ethernet V/A 3.1 Color Graphic Program KMF 9020-0309 -10 C to 100 C 0.5 Ethernet V/A 3.1 Color Graphic Program T A : Ambient A: Audible V: Visual Reinforced Shelves Access ports with silicone plugs Replacement set illumination tubes for one illumination cassette (KBF P KBF LQC) Specimen temperature display with PT 100 sensor
BINDER Scientific Products Growth Cell and tissue cultures C CB Microbiology BD BF KB KT In vivo and In vitro cultures KBW KBWF Storage Sample storage UF V Drying and tempering Drying and heat treatment ED FD FED Material testing FP M Safety drying FDL Vacuum drying VD VDL V 2016; The illustrations, information and technical specification contained in this catalog are all subject to change. Environmental simulation Constant climate testing KBF Constant climate testing with illumination KBF P KBF LQC Dynamic constant climate testing KMF Process documentation APT-COM BINDER Inc. 545-3 Johnson Ave Bohemia, NY 11716 USA Contact +1 (631) 224 4340 Fax: +1 (631) 224 4354 USA@binder-world.com www.binder-world.us