Installer manual SAM 40

Similar documents
Installer manual SAM 40. Supply air module IHB GB LEK

Installer manual NIBE ERS

Installer manual AHP/AHPS

Installer manual NIBE ERS

Installer manual AHP/AHPS

User and Installer manual NIBE UKV 20

Installer manual NIBE ERS

User manual NIBE F135

Installation and Operating Manual

Installer manual ELK 213 Immersion heater

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

Installer manual NIBE FLM. Exhaust air module IHB GB LEK

Installer manual NIBE F135

User manual NIBE F110

User manual NIBE F130. Hot water heat pump

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE Hot Water Storage Tank with Coil

User manual NIBE F2040

Installer manual SMO 40

User manual NIBE SPLIT HBS 05 AMS 10-8 / / 10-16, HBS / 05-16

Installer manual SMO 40. Control module IHB GB LEK

LEK MOS UK VPA 300/200, 450/ INSTALLATION AND MAINTENANCE INSTRUCTIONS VPA 300/200, 450/300

Installer manual SMO 20. Control module IHB GB LEK

User manual NIBE F , 12, 16 kw Air/water heat pump UHB GB LEK LEK LEK

User manual NIBE F2016

User manual AMS 10 AMS 10-6 / 10-8 / / 10-16

User manual NIBE F2120 8, 12, 16, 20

User manual NIBE F2120 8, 12, 16, 20

User manual NIBE SMO 05. Accessories UHB GB LEK

Installer manual NIBE VVM 500. Indoor module APH

Operating manual NIBE F1345. Ground source heat pump OHB GB LEK

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 310. Indoor module IHB GB

Installer manual NIBE F750. Exhaust air heat pump IHB GB LEK

User manual NIBE F2300

Installer manual NIBE VVM 310. Indoor module IHB GB

User manual NIBE F2300

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 310

Installer manual NIBE VVM 500

User manual NIBE SMO 05

Installer manual NIBE F370

Installer manual NIBE F470

User manual NIBE SMO 20

Installer manual ELK 213 Immersion heater

Installer manual NIBE F370

Installer manual NIBE VVM 500. Indoor module APH

User manual NIBE VVM 500

Installer manual NIBE F1245. Ground source heat pump IHB GB

User manual NIBE F470

Installer manual NIBE SPLIT HBS 05

User manual NIBE VVM 310

Installer manual NIBE F1245PC. Ground source heat pump IHB GB

User manual NIBE F470

User manual NIBE SMO 40

User manual NIBE F470. Exhaust air heat pump UHB GB LEK

User manual NIBE F1255

User manual NIBE SMO 20

Installer manual NIBE F2300. Air/water heat pump IHB GB LEK

User manual NIBE VVM 500

User manual NIBE F1145

Installer manual NIBE F2026. Air/water heat pump IHB GB LEK

User manual NIBE VVM 320

Installer manual NIBE VVM 325. Indoor module IHB GB APH

Installer manual AXC 30

Installer manual AXC 40. Accessories IHB GB LEK

Installer manual SMO 40

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

MOS GB VEDEX INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual NIBE F730

Installer manual AG-WL10

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump

Installer manual NIBE VVM 500

Installer manual NIBE F370. Exhaust air heat pump IHB GB LEK

Installer manual SMO 40

Installer manual NIBE VVM 310

Installer manual NIBE F2300. Air/water heat pump IHB GB LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS EVP EVP 500 LEK

Installer manual NIBE VVM 320

Installer manual SMO 40

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

NIBE SPLIT ACVM 270 Air/water heat pump

Installer manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

Installer manual NIBE F470

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V IHB GB

Installer manual SMO 20

INSTALLATIONS MANUAL GV-HR110. Passive ventilation / Heat recovery. Version

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

NIBE F750 A +++ Flexible, high-performance exhaust air heat pump. Exhaust air heat pump

Installer manual NIBE F1145

Outline principle. Application Buildings with water-borne heating systems. Alternative

Installer manual NIBE F1255. Ground source heat pump IHB GB

MOS GB VEDEX 3300 M10528 INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

User manual AG-WT10. Indoor unit air/air heat pump UHB GB LEK

User manual NIBE F2026

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

Transcription:

Installer manual Supply air module LEK IHB GB 1549-4 031934

LEK LEK

Table of Contents 1 Important information 4 5 Electrical connections 17 Safety information 4 General 17 2 Delivery and handling Transport 7 7 Connections 6 Commissioning and adjusting 17 18 Assembly 7 Preparations 18 Removing the covers 7 Connecting to heating medium system 18 3 The design of the supply air module 8 Start-up and inspection 7 Disturbances in comfort 18 21 4 Pipe and ventilation connections General pipe connections Symbol key Outline diagram 10 10 10 10 Info menu Manage alarm Troubleshooting 8 Accessories 21 21 21 23 Dimensions and pipe connections Mounting 11 11 9 Technical data 24 Heating medium side 12 Dimensions and setting-out coordinates 24 General ventilation connection 16 Technical specifications 25 Ventilation flow 16 Energy labelling 26 Adjusting ventilation 16 Electrical circuit diagram 27 Index 28 Table of Contents 3

1 Important information Safety information This manual describes installation and service procedures for implementation by specialists. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Rights to make any design or technical modifications are reserved. NIBE 2015. Symbols NOTE This symbol indicates danger to machine or person. Caution This symbol indicates important information about what you should observe when maintaining your installation. TIP This symbol indicates tips on how to facilitate using the product. Serial number Serial number The serial number can be found at the bottom left inside the front cover. Caution Recovery LEK Serial number Always give the product's serial number (14 digits) when contacting your installer. Leave the disposal of the packaging to the installer who installed the product or to special waste stations. When disposing of the product, the constituent materials and components, such as compressors, fans, circulation pumps and circuit boards, must be disposed of at a special waste station or at a dealer who provides this type of service. To access the separate components, refer to the section that shows the construction of the product. No special tools are required for access. Improper disposal of the product by the user results in administrative penalties in accordance with current legislation. Country specific information Installer manual This installer manual must be left with the customer. Marking is CE marked and fulfils IP21. The CE marking means that NIBE ensures that the product meets all regulations that are placed on it based on relevant EU directives. The CE mark is obligatory for most products sold in the EU, regardless where they are made. IP21 means that objects with a diameter larger than or equivalent to 12.5 mm cannot penetrate and cause damage and that the product is protected against vertically falling drops of water. 4 Chapter 1 Important information

Inspection of the installation In addition, fill in the page for the installation data in the User Manual. Current regulations require the supply air module to be inspected before it is put into service. The inspection must be carried out by a suitably qualified person. Description Notes Signature Date Ventilation (page 16) Setting ventilation flow exhaust air Setting ventilation flow supply air Heating medium (page 12) System flushed Accessories bled Check against output and pressure drop diagrams Connected according to outline diagram Electricity (page 17) Connections Phase voltage Supply connected 230 V Connected communication Chapter 1 Important information 5

Contact information AT CH CZ DE DK FI FR GB NL NO PL RU SE KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at NIBE Wärmetechnik c/o ait Schweiz AG, Industriepark, CH-6246 Altishofen Tel: (52) 647 00 30 Fax: (52) 647 00 31 E-mail: info@nibe.ch www.nibe.ch Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: nibe@nibe.cz www.nibe.cz NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle Tel: 05141/7546-0 Fax: 05141/7546-99 E-mail: info@nibe.de www.nibe.de Vølund Varmeteknik A/S, Member of the Nibe Group, Brogårdsvej 7, 6920 Videbæk Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk NIBE Energy Systems OY, Juurakkotie 3, 01510 Vantaa Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: info@nibe.fi www.nibe.fi NIBE Energy Systems France Sarl, Zone industrielle RD 28, Rue du Pou du Ciel, 01600 Reyrieux Tel : 04 74 00 92 92 Fax : 04 74 00 42 00 E-mail: info@nibe.fr www.nibe.fr NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk NIBE Energietechniek B.V., Postbus 634, NL 4900 AP Oosterhout Tel: 0168 477722 Fax: 0168 476998 E-mail: info@nibenl.nl www.nibenl.nl ABK AS, Brobekkveien 80, 0582 Oslo, Postadresse: Postboks 64 Vollebekk, 0516 Oslo Tel. sentralbord: +47 23 17 05 20 E-mail: post@abkklima.no www.nibeenergysystems.no NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: sekretariat@biawar.com.pl www.biawar.com.pl "EVAN" 17, per. Boynovskiy, Nizhny Novgorod Tel./fax +7 831 419 57 06 E-mail: info@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: info@nibe.se www.nibe.se For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information. 6 Chapter 1 Important information

2 Delivery and handling Transport The supply air module must be transported and stored dry. Assembly is mounted free standing on brackets, alternatively above a VPB 200 (For VPB 300/VPBS 300 installation is with the help of brackets). Noise from the fan can be transferred to the brackets. Install the brackets to an outside wall, ideally in a room where noise does not matter, in order to eliminate noise problems. If this is not possible, avoid placing it against a wall behind a bedroom or other room where noise may be a problem. Wherever the unit is located, walls to sound sensitive rooms should be fitted with sound insulation. Route pipes so they are not fixed to an internal wall that backs on to a bedroom or living room. Removing the covers Front cover 1. Remove the service cover by pulling it straight out. LEK Installation area Leave a free space of 500 mm in front of the supply air module. All service on can be carried out from the front. 800 NOTE Ensure that there is sufficient space (300 mm) above the supply air module for installing ventilation hoses. Chapter 2 Delivery and handling 7

3 The design of the supply air module BT22 XL33 QM20 XL34 BT23 LEK LEK AA5 PF 1 HQ11 AA100 AA5-S2 XL33 QM20 XL34 QN40 BT69 BT68 SF1 LEK PF1 HQ11 LEK LEK Svenskt produktblad EP13 GQ3 XL37 XL36 W102 W101 SF1 QN40 8 Chapter 3 The design of the supply air module LEK

Pipe connections XL33 Ventilation connection supply air XL34 Ventilation connection outdoor air XL36 Connection, heating medium in XL37 Connection, heating medium out 1 HVAC components EP13 Supply air battery QM20 Venting heating medium QN40 Control valve heating medium Sensors etc. BT22 Temperature sensor, supply air BT23 Temperature sensor, outdoor air BT68 Temperature sensor, flow BT69 Temperature sensor, return 1 Electrical components AA5 Accessory card AA5-S2 Dip switch AA100 Joint card SF1 Switch, position 0-1, main switch W101 Cord with connection plug W102 Control cable Ventilation GQ3 Supply air fan HQ11 Air filter supply air Miscellaneous PF1 Rating plate 1 Not visible in the image Designations in component locations according to standard IEC 81346-1 and 81346-2. Chapter 3 The design of the supply air module 9

4 Pipe and ventilation connections General pipe connections Pipe installation must be carried out in accordance with current norms and directives. Symbol key Outline diagram -EB100 -AZ2 Symbol Meaning Control valve Shunt / shuttle valve Temperature sensor Expansion vessel Circulation pump Fan Compressor -CP1 Heat exchanger Caution If the total circulating volume in the climate system (excluding the heat pump volume) falls below 40 litres, extra system volume is connected, for example volume vessel UKV (CP1) according to the outline diagram above. NOTE If several climate systems (ECS 40/ECS 41) are present, must be connected in parallel with climate system 1. A circulation pump must be used to ensure the flow over. 10 Chapter 4 Pipe and ventilation connections

Dimensions and pipe connections 40 Mounting Installing on brackets 1. Install on brackets. 2. Connect heating medium and ventilation pipes. Ø22 295 75 320 210 LEK LEK 420 40 55 Chapter 4 Pipe and ventilation connections 11

Installing on VPB 200 Caution For connection of VPB 200 together with F750 docking kit DEW 40 is used. 1. Remove the service cover from VPB 200. 2. Remove the top panel from VPB 200 (installed with 6 screws). 3. Install DEW 40 according to the instructions in the installation manual. The pipes in VPB 200 can be adjusted/replaced in such a way that can easily be installed above VPB 200. 4. Install from the top and slide into position. Heating medium side A water borne climate system with a volume of at least 20 litres of circulating water must be present for installation of to be possible. For the correct function of the total volume of the climate system (excluding the internal volume in F750) must exceed 40 litres of circulating water. This means that, if the volume of the climate system does not exceed 40 litres of circulating water, installation of volume vessel (NIBE UKV) is necessary. Dimensioning the system 1. Work from the water temperature at DUT (DVUT). 2. Work from the current supply air flow. 3. Work from the desired supply air temperature, then calculate the output that must give at DUT. 4. Determine the water flow across from the correct output diagram. NOTE! For supply temperatures that are not in one of the diagrams, an estimate (linear interpolation) can be carried out. 5. Work from the projected pressure drop (at the projected flow) in the water borne system, climate system 1. 6. Check in the pressure drop diagram that the working point is inside the grey working area. 7. Check that the pump capacity from F750 is sufficient for both the heating system and. LEK 5. Secure with the 2 screws supplied. LEK 6. Connect heating medium and ventilation pipes. 7. Reinstall the service cover on VPB 200. 12 Chapter 4 Pipe and ventilation connections

Output transfer to the supply air Power Effekt output (W) (W) Flow line temperature 35 C 4800 4600 600 l/h DUT -30 ºC 4400 4200 4000 3800 3600 3400 3200 200 l/h DUT -30 ºC 600 l/h DUT -20 ºC 200 l/h DUT -20 ºC 600 l/h DUT -10 ºC 3000 75 l/h DUT -30 ºC 2800 200 l/h DUT -10 ºC 2600 2400 75 l/h DUT -20 ºC 2200 75 l/h DUT -10 ºC 2000 1800 1600 1400 Supply 1200 Luftflöde air flow 100 125 150 175 200 225 250 (m3/h) 30 40 50 60 70 (l/s) Power Effekt output (W) Flow line temperature 45 C 5400 600 l/h DUT -30 ºC 5200 5000 4800 200 l/h DUT -30 ºC 4600 600 l/h DUT -20 ºC 4400 4200 200 l/h DUT -20 ºC 4000 600 l/h DUT -10 ºC 3800 3600 3400 3200 3000 75 l/h DUT -30 ºC 200 l/h DUT -10 ºC 75 l/h DUT -20 ºC 2800 2600 75 l/h DUT -10 ºC 2400 2200 2000 1800 1600 Supply 1400 Luftflöde air flow 100 125 150 175 200 225 250 (m3/h) 30 40 50 60 70 (l/s) Chapter 4 Pipe and ventilation connections 13

Power Effekt output (W) Flow line temperature 55 C 6200 6000 600 l/h DUT -30 ºC 5800 5600 5400 600 l/h DUT -20 ºC 5200 200 l/h DUT -30 ºC 5000 4800 4600 200 l/h DUT -20 ºC 600 l/h DUT -10 ºC 4400 4200 4000 200 l/h DUT -10 ºC 75 l/h DUT -30 ºC 3800 3600 75 l/h DUT -20 ºC 3400 3200 3000 75 l/h DUT -10 ºC 2800 2600 2400 2200 2000 1800 Supply 1600 Luftflöde air flow 100 125 150 175 200 225 250 (m3/h) 30 40 50 60 70 (l/s) 14 Chapter 4 Pipe and ventilation connections

Pressure drop diagram 35 kpa Pressure Tryckfall drop över over SAM SAM 40 40 30 25 20 15 10 5 Water flow above Flöde 0 0 100 200 300 400 500 600 700 800 900 1000 (l/h) The diagram shows pressure drop across at different water flows. Note that the pressure drop is the same as that which prevails across the climate system 1. Check that the working point is inside the grey working area. If the working point is inside the darker grey area to the left of the diagram, it can give an oscillating supply air temperature. NOTE Venting may be necessary on installation and after a period of use. Vent through vent valve (QM20). Chapter 4 Pipe and ventilation connections 15

General ventilation connection Ventilation installation must be carried out in accordance with current norms and directives. To prevent fan noise being transferred to the supply air devices, it may be a good idea to install a silencer in the duct. This is especially important if there are supply air devices in bedrooms. Connections must be made via flexible hoses, which must be installed so that they are easy to replace. The air should be routed to the outdoor air duct through an outside wall grille in the facade. The outer wall grille must be installed protected from the weather and must be designed so that no rain water can penetrate the facade. The outdoor air duct must be provided with diffusion-tight insulation over its entire length. Ensure that the condensation insulation is sealed at any joints and/or at lead-in nipples, silencers, roof cowls or similar. Provision must be made for inspection and cleaning of the duct. Make sure that there are no reductions of cross-sectional area in the form of creases, tight bends etc, since this will reduce the ventilation capacity. The air duct system must be a minimum of air tightness class B. Ventilation flow The supply air flow must be lower than the exhaust air flow to prevent over pressure in the house. Ensure that the ventilation openings are not blocked. Set the ventilation capacity in the heat pump's menu system (menu 5.1.6). Adjusting ventilation To obtain the necessary air exchange in every room of the house, the exhaust air device and the supply air device must be correctly positioned and adjusted and the fans in the heat pump and supply air module adjusted. Immediately after installation adjust the ventilation so that it is set according to the projected value of the house. A defective ventilation installation may lead to reduced installation efficiency and thus poorer operating economy, and may result in moisture damage to the house. Supply air Outdoor air 450 160 275 195 LEK Ø160 16 Chapter 4 Pipe and ventilation connections

-X8 -X8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 -X4 -X4 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 -X2 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 -X2 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 -X10 -X1N L PE PE 9 8 7 6 5 4 3 2 1 -X10 -X1N L PE PE -X9 -X9 9 8 7 6 5 4 3 2 1 N L PE PE 5 Electrical connections General All electrical equipment is connected at the factory. Disconnect before insulation testing the house wiring. For the supply air module wiring diagram, see page 27. Signal cables to external connections must not be laid close to high current cables. If the supply cable is damaged, only NIBE, its service representative or similar authorised person may replace it to prevent any danger and damage. EB100 A B GND AA3-X4 15 14 13 F750 AA3-X4 NOTE Electrical installation and service must be carried out under the supervision of a qualified electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. Accessory card 1 AA5-X4 A 1 B 2 GND 3 A 4 B 5 GND 6 7 8 AA5-X4 ON 1 2 3 4 5 6 7 8 Connections Connecting to F750 This section describes the electrical connection for controlling from NIBE F750. The heat pump switch must be in the " " position and the switch on in position 0, before any work is carried out. 1. Ensure that the products are completely disconnected from the power source. Remove the front hatch and protective cover to the input card on the heat pump according to the instructions in its Installer's manual. 2. Connect cable W102 to position X4 on the input board in the heat pump, according to the electrical wiring diagram on page 27. Use the cable lead-in in the heat pump when routing cables. If several accessories are to be connected or are already installed, the adjacent wiring diagram must be followed. The first accessory board must be connected directly to the heat pump's terminal block AA3-X4. The following boards must be connected in series to the previous board. 3. Fix external cable routing. 4. Install the protective cover and the service cover according to the heat pump Installation manual. 5. Connect plug W101. Accessory card 2 A B GND A B GND DIP switch AA5-X4 1 2 3 4 5 6 7 8 AA5-X4 The DIP-switch (S2) on the accessory board (AA5) is set in the factory as below. 1 2 3 4 5 6 7 8 ON AA5-S2 -X8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 -X4 -X2 -X10 -X1 -X9 Chapter 5 Electrical connections 17

6 Commissioning and adjusting Preparations 1. Check that the switch (SF1) for F750 is in position " 2. Check that the filling valves (QM10) and (QM11) in the heat pump are fully closed. Caution Check the miniature circuit-breaker (FA1) in the heat pump. It may have tripped during transportation. Connecting to heating medium system 1. Connect according to the outline diagram on page 10. 2. Fill with water using the filler valve (QM11) in F750. 3. Vent the heating medium system with the vent valves (QM20) above, and the vent valves in F750 and fill if necessary using the filler valve (QM11) in F750. Start-up and inspection Start-up NOTE There must be water in the climate system before the switch in F750 is set to " ". 1. Set switch (SF1) on in position "1". 2. Set the heat pump's switch (SF1) to "". 3. Follow the instructions in the start guide in the heat pump display. If the start guide does not start when you start the heat pump, start it manually in menu 5.7. Commissioning The first time the heat pump is started a start guide is started. The start guide instructions state what needs to carried out at the first start together with a run through of the heat pump s basic settings. The start guide ensures that the start-up is carried out correctly and cannot be bypassed. The start guide can be started later in menu 5.7. This applies to a heat pump with approximately 4 kw rated output. For a 15 kw heat pump the corresponding flow is from 0.09 l/s (324 l/h) to 0.14 l/s (504 l/h). Caution As long as the start guide is active, no function in the installation will start automatically. The guide will appear at each installation restart until it is deselected on the last page. 18 Chapter 6 Commissioning and adjusting

Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu 5.2 -system settings Activating/deactivating of accessories. Select: "ext sup air md" Caution This accessory may require a program software update in your F750. The heat pump software must be version 3585R2 or later. Setting the ventilation Ventilation must be set according to applicable standards. The supply air flow is adjusted so that it is 80% of the exhaust air flow. The setting is made in menu 5.1.6. Even if ventilation is roughly set at installation it is important that a ventilation adjustment is ordered and permitted. Available pressure (Pa) (Pa) 400 NOTE Order a ventilation adjustment to complete the setting. 350 300 250 200 90/100% 150 80% 70% 100 60% 50 40% 50% 0 0 50 100 150 200 250 300 20 40 60 80 Airflow Luftflöd (m3/h) (l/s) Power Effekt output (W) (W) 120 100 90/100% 80 80% 60 70% 40 20 40% 50% 60% 0 0 50 100 150 200 250 300 20 40 60 80 Airflow Luftflöde (m3/h) (l/s) Chapter 6 Commissioning and adjusting 19

Setting of supply air temperature Set the supply air temperature in menu 5.3.9 (ext sup air md). Note that when changing the supply air temperature, the settings for other parts of the climate system need to be adjusted. ext sup air md 5.3.9 supply air temp. at low outd temp. outdoor temp.t1 supply air temp. at T1 C C supply air temp. at avg outdoor temp. outdoor temp.t2 C At outdoor temperatures that lie between the stated points in the diagram below, the supply air temperature can be calculated linearly. The angle of the graph continues outside the stated points. Min. Supply air temperature 52 48 44 40 36 32 28 24 20 16-20 -15-10 -5 0 5 10 15 20 T1 T2 T3 Outdoor temp. (BT1) Max 20 Chapter 6 Commissioning and adjusting

7 Disturbances in comfort In most cases, the heat pump F750 notes operational interference (operational interference can lead to disturbance in comfort) and indicates this with alarms and shows action instructions in the display. Info menu All the heat pump measurement values are gathered under menu 3.1 in the heat pump menu system. Looking through the values in this menu can often simplify finding the source of the fault. Manage alarm alarm info / action reset alarm aid mode Low pressure alarm In the event of an alarm, some kind of malfunction has occurred, which is indicated by the status lamp changing from green continuously to red continuously. In addition, an alarm bell appears in the information window. Alarm In the event of an alarm with a red status lamp a malfunction has occurred that the heat pump cannot remedy itself. In the display, by turning the control knob and pressing the OK button, you can see the type of alarm it is and reset it. You can also choose to set the heat pump to aid mode. info / action Here you can read what the alarm means and receive tips on what you can do to correct the problem that caused the alarm. reset alarm In most cases it is enough to select "reset alarm" to correct the problem that caused the alarm. If a green light illuminates after selecting "reset alarm" the alarm has been remedied. If a red light is still visible and a menu called alarm is visible in the display, the problem that caused the alarm remains. If the alarm disappears and then returns, see the troubleshooting section (page 21). aid mode aid mode is a type of emergency mode. This means that the heat pump produces heat and/or hot water despite there being some kind of problem. This can mean that the heat pump's compressor is not running. In this case the immersion heater produces heat and/or hot water. NOTE To select aid mode an alarm action must be selected in the menu 5.1.4. Caution Selecting "aid mode is not the same as correcting the problem that caused the alarm. The status lamp will therefore continue to be red. Troubleshooting If the operational interference is not shown in the display the following tips can be used: Basic actions Start by checking the following possible fault sources: That the heat pump is running or that the supply cable to is connected. Group and main fuses of the accommodation. The property's earth circuit breaker. The heat pump's miniature circuit breaker (FA1). The heat pump's temperature limiter (FD1). Correctly set load monitor (if installed). Low hot water temperature or a lack of hot water The heat pump has temporarily prioritised supply air ventilation to prevent too low temperatures in the supply air coil. Low room temperature Air in the heating medium system. Vent using vent valve (QM20). Incorrect value set in supply air automatic control system. Enter menu 5.3.9 (ext sup air md) and adjust the setting for the supply air temperature. High room temperature Incorrect value set in supply air automatic control system. Enter menu 5.3.9 (ext sup air md) and adjust the setting for the supply air temperature. Low or a lack of ventilation Filter (HQ12) blocked. Clean or replace the filter. The ventilation is not adjusted. Order/implement ventilation adjustment. Supply air device closed, blocked or throttled down too much. Check and clean the supply air device. High or distracting ventilation Filter (HQ12) blocked. Clean or replace the filter. The ventilation is not adjusted. Order/implement ventilation adjustment. Low supply air temperature Air in the heating medium system. Chapter 7 Disturbances in comfort 21

Vent using vent valve (QM20). Incorrect value set in supply air automatic control system. Enter menu 5.3.9 (ext sup air md) and reduce the setting for the supply air temperature. High supply air temperature Incorrect value set in supply air automatic control system. Enter menu 5.3.9 (ext sup air md) and adjust the setting for the supply air temperature. 22 Chapter 7 Disturbances in comfort

8 Accessories Brackets Wall mounting of. Part no. 067 083 Buffer vessel UKV UKV 40 Part no. 088 470 Top cabinet Top cabinet for concealing the ventilation ducts. 345 mm 395-645 mm Part no. 089 757 Part no. 089 758 Chapter 8 Accessories 23

9 Technical data Dimensions and setting-out coordinates 40 Ø22 Ø160 160 295 320 450 595 75 45 35 300 355 420 600 210 540 195 275 290 305 40 55 24 Chapter 9 Technical data

Technical specifications Electrical data Supply voltage Drive output actuator motor Driving power fan Enclosure class Heating medium circuit Min pressure Max pressure Ventilation Max airflow Sound power level according to EN 12,102 Sound power level (L w(a )) 1 Sound pressure levels Sound pressure level in the boiler room (L (PA) ) 2 Pipe connections Heating medium ext Ø Hot water ext Ø Ventilation Ø Dimensions and weight Width Depth Height Weight Part No. V W W MPa/bar MPa/bar m 3 /h db (A) db (A) mm mm mm mm mm mm kg 230 V 50 Hz 1.5 175 IP21 0.05/0.5 0.25/2.5 300 45-50 41-46 22 22 160 600 556 396 31 067 147 1The value varies with the selected fan curve. For more detailed sound data including sound to channels visit www.nibe.eu. 2 The value can vary with the room's damping capacity. These values apply with a damping of 4 db. Chapter 9 Technical data 25

Energy labelling Supplier Model Specific energy consumption (SEC) Energy efficiency class Declared typology Type of drive Type of heat recovery system Thermal efficiency of heat recovery Maximum air flow rate Electric power input of the fan drive at maximum flow rate Sound power level (LWA) Reference flow rate Reference pressure difference Specific power input (SPI) Control factor and control typology External leakage rates Information about filter warning Information about supply/exhaust grilles in the facade Information about pre-/disassembly The annual electricity consumption Annual heating saved, kwh primary energy per year kwh/(m 2 year) m 3 /h W db m 3 /s (m 3 /h) Pa W/m 3 /h % kwh/year kwh prim/year NIBE Average: -11.0 Cold: -28.9 Warm: 0.7 E RVU, Unidirectional Variable speed drive None 0 290 108 50 0.0583 (210) 78 0.262 Clock control (0.95) < 3 See user manual. See section General ventilation connection on page 16. See section Recovery on page 4. This installer manual can also be accessed at www.nibe.eu. 312 Average: 1,874 Cold: 3,667 Warm: 848 26 Chapter 9 Technical data

Electrical circuit diagram Chapter 9 Technical data 27

10 Item register Item register A Accessories, 23 Adjusting ventilation, 16 Alarm, 21 Assembly, 7 C Commissioning and adjusting, 18 Connecting to heating medium system, 18 Preparations, 18 Start-up and inspection, 18 Connecting to heating medium system, 18 Contact information, 6 D Delivery and handling, 7 Removing the covers, 7 Dimensions and pipe connections, 11 Dimensions and setting-out coordinates, 24 Disturbances in comfort, 21 Alarm, 21 Manage alarm, 21 Troubleshooting, 21 E Electrical circuit diagram, 27 Electrical connections, 17 Connections, 17 General, 17 Energy labelling, 26 H Heating medium side, 12 Output transfer to the supply air, 13 I Important information, 4 Recovery, 4 Safety information, 4 Inspection of the installation, 5 M Manage alarm, 21 Marking, 4 O Output transfer to the supply air, 13 P Pipe and ventilation connections, 10 Adjusting ventilation, 16 Dimensions and pipe connections, 11 General pipe connections, 10 General ventilation connection, 16 Heating medium side, 12 Ventilation flow, 16 Pipe connections Symbol key, 10 Preparations, 18 R Removing the covers, 7 S Safety information, 4 Contact information, 6 Inspection of the installation, 5 Marking, 4 Serial number, 4 Symbols, 4 Serial number, 4 Start-up and inspection, 18 Setting the ventilation, 19 Symbol key, 10 Symbols, 4 T Technical data, 24 Dimensions and setting-out coordinates, 24 Electrical circuit diagram, 27 Technical Data, 25 Technical Data, 25 The design of the supply air module, 8 List of components, 9 Transport Assembly, 7 Troubleshooting, 21 V Ventilation flow, 16 28 Chapter 10 Item register

WS name: -Gemensamt WS version: a129 (working edition) Publish date: 2015-12-15 10:44 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 031934