Tristor MF. Installation Guide

Similar documents
Tornado & Tempest Stainless. Installation Guide & Customers Copy (including Solar, Heat Pump & Horizontal)

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer:

ADVANCE ECB ELECTRIC COMBINATION BOILER

SEALED THERMAL STORE

ADVANCE ELECTRIC THERMAL STORE

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

THERMflow Thermal Store Cylinders

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Tornado & Tempest Stainless Installation Guide & Customers Copy (including Solar, Heat Pump & Horizontal)

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

CUBEflow Thermal Store Tank

MURELLE EV HE 25/55-30/55

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Avanta 12v - 15v - 18v - 24v - 30v

ir-range 8G /03.15 Changes reserved.

User s Operation Instructions & Important Warranty Information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Instructions for Use Installation and Servicing

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Instructions for Installation, Servicing and Use

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

CPC-150-ABIAB. Important Installation Notes.

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Combi Eco Elite Range. User s Guide and Important Warranty Information

Unvented Electric Water Heater 10/15 litre Undersink

User Guide. Promax SL Condensing Central Heating Boiler

Installation Manual EXCELSIOR Unvented Water Heater

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

ZIP AQUAFLO II Unvented storage cylinders

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Megaflo Eco SystemReady Unvented Indirect Hot Water Cylinders

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

MEGAFLO HE Iss 1

CPC-150-ANA. 150 litres, 535mm x 1300mm high. Pandora Heat Bank. 100kW Plate Heat Exchanger with 22mm Thermostatic Mixing Valve.

Installation and User Instructions HS10U, HS15U.

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

HOTFLO 10 / 15. Fitting Instructions and User Guide

HW3 Handwash Installation and Operating Instructions

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Unvented Direct & Indirect Hot Water Cylinders (400L L)

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Streamline Undersink. Fitting Instructions and User Guide

INSTALLATION & TECHNICAL MANUAL

Stainless Steel Unvented Cylinders

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

Installation and Commissioning Manual

Installation & Technical Guide. Domestic & Commercial.

User Guide. Gold Combi Condensing Combination Boiler

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

Unvented water heating

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

Manual Heatstream Installation & Maintenance

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Alpha FlowSmart 25 and 50

Assessment Schedule - TS.6

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Unvented Direct & Indirect Hot Water Cylinders

Multipoint. Unvented point of use hot water

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Multipoint Technical Data

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

Flomaster Installation & Maintenance Instructions for an unvented hot water cylinder with external thermal expansion

UNVENTED HOT WATER SYSTEM ANNUAL SERVICE REQUIRED

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Transcription:

Tristor MF Installation Guide Tel 1952 257963 Fax 1952 253452 Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE www.telford-group.com NOV 24

Parts Installer Replaced Registration Number Installed and ommissioned First Annual Second Annual Third Annual Fourth Annual Fifth Annual Sixth Annual The Benchmark Scheme Telford opper and Stainless ylinders is a licensed member of the Benchmark Scheme which aims to improve the standard of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturers instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark hecklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out the installation, commissioning and servicing work in accordance with the Benchmark ode of Practice which is available from the Heating and Hotwater Industry ouncil who manage and promote the Scheme. Visit www.centralheating.co.uk for more information. The HWA harter Statemant requires that all members adhere to the following: To supply fit for purpose products clearly and honestly described To supply products that meet, or exceed appropriate standards and building and water regulations To provide pre and post sales technical support To provide clear and concise warranty details to customers Visit: www.hotwater.org.uk Seventh Annual Eighth Annual Ninth Annual Tenth Annual THE INSTALLER MUST SIGN THE BENHMARK HEKLISTS AND FILL IN THE APPROPRIATE INSTALLATION INFORMATION. OMPLETING THE OMMISSIONING AND USER INSTRUTIONS IS A REQUIREMENT OF ADL1 OF THE BUILDING REGULATIONS. FAILURE TO DO SO MAY INVALIDATE THE WARRANTY ON THIS PRODUT. All Electrical Instalation Must be to IEE Standards For term and condition please refer to our website: www.telford-group.com

NOTES 1 Installation of Tristor MF At the time of commissioning, complete all relevant sections of the Benchmark hecklist located on the inside back pages of this document. 1. Fit Tristor onto a level floor 2. Fit 3bar pressure reducing valve to Tristor MF, if Tristors are regulated on apartment level fit check valve as good practice to all Tristors. 3. Fit stop cock valve to mains cold feed. 4. Fit stop cock valve to hot water supply. 5. Tristor can only fill with electric on to open valve. Do not operate with electric off. 6. Once electric is on fill Tristor to water indent line inside expansion can (pour inhibitor in to expansion tank before filling). After filling open hot taps to remove air. 7. Always use plumber past on compression fittings not p.t.f.e tape. 8. Once filled to indent line remove filling loop and fit 2x 1/2"caps one to service valve and one to expansion can. 9. Over fill box must be wired to a 3amp fuse switched spur. 1. Each immersion heater must be wired to a 13 amp switched fuse spur, also fit 16 amp mcb into consumer unit type B for each immersion. 11. Always fit lid after filling and inspection to stop condensation forming inside Tristor. 12. Always stay with Tristor when filling, do not rely on over fill float as power suppy can be interrupted during building construction on site. 13. heck fittings as they may come loose in transit and when adding pipe work. 14. heck stats are set to 7/75 c on both top and bottom immersion heaters. 15. Telford opper ylinders do not recommend fitting timer controls to thermal stores, stats will control water heaters. 16. Fit water softener in hard water areas. Servicing: After servicing, complete the relevant Interval Record section of the Benchmark hecklist located on the inside back pages of this document. All Electrical Instalation Must be to IEE Standards Telford opper ylinders do not recommend fitting timer controls to thermal stores stats with control water heaters. Telford opper ylinders do not hold responsibility for errors or omissions. Failure to install and commission the appliance to the Manufacturers instructions may invalidate the warranty. This guarantee is only available in the United Kingdom of Great Britain and Northern Ireland. laims made against our Guarantee must be supported with evidence of purchase and the product serial number, along with a copy of the completed Benchmark booklet and service record. Your Statutory rights are not affected by this guarantee. 3

DIAGRAM OF TRISTOR MF Switch float for overfill FILLING LOOP SERVIE REORD It is recommended that your hot water system is serviced regularly and that the appropriate Record is completed. SERVIE PROVIDER Before completing the appropriate Record below, please ensure you have carried out the service as described in the manufacturer s instructions. SHOK ARRESTER F & E AN FILL INDENT HOT OUT FILL VALVE 22mm PIPE MIXER VALVE OLD IN Vc 4613 DOMESTI OIL OVERFILL BOX SERVIE 1 SERVIE 3 SERVIE 2 SERVIE 4 SERVIE 5 SERVIE 6 TOP IMMERSION HEATER SERVIE 7 SERVIE 8 OUTER ASE BOTTOM IMMERSION HEATER DRAIN OFF THERMAL FOAM SERVIE 9 SERVIE 1 4 9

UNVENTED SYSTEMS ONLY Where is the pressure reducing valve situated (if fitted)? What is the pressure reducing valve setting? Has a combined temperature and pressure relief valve and expansion valve been fitted and discharge tested? No The tundish and discharge pipework have been connected and terminated to Part G of the Building Regulations Are all energy sources fitted with a cut out device? No Has the expansion vessel or internal air space been checked? No THERMAL STORES ONLY What store temperature is achievable? What is the maximum hot water temperature? bar ELETRIAL INSTALLATION The unit is provided with two 3Kw Immersion Heaters these must be connected to single phase 23V supplies via a suitable switched fused isolator. The control of these units will depend on the type of Tariff/Supply Agreements in place (no timer controls are supplied with the spacesaver unit). NOTE: Telford opper ylinders does not recommend the use of timers with Thermal Store Units. We strongly advise leaving the units to run from a constant supply managed by internal thermostats, this will ensure the unit is always at temperature and ready to deliver hot water. ALL INSTALLATIONS The hot water system complies with the appropriate Building Regulations The system has been installed and commissioned in accordance with the manufacturer s instructions The system controls have been demonstrated to and understood by the customer The manufacturer s literature, including Benchmark hecklist and Record, has been explained and left with the customer ommissioning Engineer s ustomer s (To confirm satisfactory demonstration and receipt of manufacturer s literature) ALL ELETRIAL WORK TO BE ARRIED OUT BY AN ELETRIIAN ELEMENT TEST Turn off power supply at consumer unit and remove fuse from fuse spur. Set multimetre to 2 ohms put prob on neutral and the other prob on live on immersion heater. The reading should be 17.5 to 19.5 tested ok if 15 to 14 ohms the element has too much resistance immersion heater will need changing. *All installations in England and Wales must be notified to Local Authority Building ontrol (LAB) either directly or through a ompetent Persons Scheme. A Building Regulations ompliance ertificate will then be issued to the customer. Please ensure that the installer has fully completed the Benchmark hecklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). Heating and Hotwater Industry ouncil (HH) 8 www.centralheating.co.uk 5

Diagnostics on TRISTOR STORE MF Warning all electrical work to be carried out by an electrician to IEE Standard WATER NOT FILLING THERMAL STORE heck stop cock valve is open and water runs from taps. 1. heck OVER FILL fuse spur switch is switched on and fuse has not blown. 2. heck consumer unit has not tripped. 3. heck service valve is open on filling loop (close after filling store to indent line in F & E AN and remove filling loop and replace 2 x 1/2 blank caps on can and service valve. 4. heck continuity on float wires (by lifting float up and down, and testing with multimetre for open & closed circuit). If test fails change float switch. 5. heck grey 2 port vc valve is open. When the white lifter on the side of the valve points towards the brass body the valve is open. When the white lifter points towards the actuator head the valve is closed. heck water level has not reached float if in closed position. If over filled up to float inside can then down drain to fill indent line to power vc4613 open. 6. heck terminal S on PB board. No voltage when float is in low position. 24 volts when float is in high position. Float is fitted inside can, replace lid after to stop condensation roaming inside the body. When 24 volts at terminal S this will close valve. 7. If all above is ok change vc4613 valve. NO WATER PASSING THROUGH HOT TAPS 8. heck stop cock valve is open. 9. heck grey 2 port valve is open. When the white lifter on the side of the valve points towards the brass body the valve is open. When the white lifter points towards the plastic actuator head the valve is closed. If in closed position see water not filling thermal store above. 1. heck filters on all domestic taps in bathroom and kitchen. 11. heck mixer valve inside the top of Tristor is not blocked if not blocked replace mixer valve. NO HOT WATER AT TAPS 12. heck top and bottom immersion heater fused spur switches are switched on at wall, and fuse has not blown (before switching immersion heater on check the thermal store has been filled with water by looking inside can for water level) see No. 3 if F&E can needs filling. 13. heck consumer unit has not tripped. 14. heck Hi limit reset button has not tripped inside immersion heater see page immersion stats for picture. 15. heck top and bottom immersion heater regulated stats are set at 7/75 o. The regulated stat is the one with the mains in coming brown wire connected to it (see page immersion stats). 16. heck temperature reading of the top immersion heater brass body is at 68-75 o. (If no temperature, check 24v at immersion cables if there is 24v change stats. (only to be tested by electrician) WARNING HIGH VOLTAGE TURN OFF POWER AT ONSUMER UNIT. 17. Remove top lid to inspect water level reaches the FILL INDENT LINE. Low water level will stop internal domestic coil from heating the water to hot taps. If water level is low open service valve on filling loop and fill to indent line. 18. heck hot & cold on mixer valve. old in connected to hot in connected to H. If in correct position and all above have been checked replace mixer valve (remember which way hot and cold-ports connect to pipe work). MAINS PRESSURE HOT WATER STORAGE SYSTEM OMMISSIONING HEKLIST The ommissioning hecklist is to be completed in full by the competent person who commissioned the storage system as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference. Failure to install and commission this equipment to the manufacturer s instructions may invalidate the warranty but does not affect statutory rights. ustomer Name Address ylinder Make and Model ylinder Serial Number ommissioned by (print name) Registered Operative ID Number ompany Address ommissioning To be completed by the customer on receipt of a Building Regulations ompliance ertificate*: Building Regulations Notification Number (if applicable) ALL SYSTEMS PRIMARY SETTINGS (indirect heating only) Is the primary circuit a sealed or open vented system? Sealed Open What is the maximum primary flow temperature? ALL SYSTEMS What is the incoming static cold water pressure at the inlet to the system? Has a strainer been cleaned of installation debris (if fitted)? No Is the installation in a hard water area (above 2ppm)? No If yes, has a water scale reducer been fitted? No What type of scale reducer has been fitted? What is the hot water thermostat set temperature? What is the maximum hot water flow rate at set thermostat temperature (measured at high flow outlet)? Time and temperature controls have been fitted in compliance with Part L of the Building Regulations? Type of control system (if applicable) Y Plan S Plan Other bar l/min Is the cylinder solar (or other renewable) compatible? No What is the hot water temperature at the nearest outlet? All appropriate pipes have been insulated up to 1 metre or the point where they become concealed 6 7