Detroit Radiant Products Co.

Similar documents
Detroit Radiant Products Co.

INSTALLATION AND SERVICE MANUAL

ASX7-5-IOM-3 J

INSTALLATION INSTRUCTIONS

ASX7-4-IOM-6 J

INSTALLATION AND SERVICE MANUAL

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

INSTALLATION INSTRUCTIONS

SEPARATED COMBUSTION WARNING

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

SEPARATED COMBUSTION. General WARNING

Ventis Direct Vent. Installation Instructions

SEPARATED COMBUSTION. General

FA Series Manual WARNING. Detroit Radiant Products Company. Installation, Operation, Maintenance and Parts. For Your Safety

Pellet Stove. Flex Pipe. Appliance Connector

Installation and Maintenance Instructions

P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

Tube Heater General Manual

BDM Direct Vent systems are for use with direct vent gas fired appliances.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Installation and Maintenance Instructions

Installation & Maintenance Instructions

EUTECTIC EC-10DV Series

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

MX 200. MX-200 Technical Specifications FEATURES:

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Saf-T Vent SC Plus/SC 316

DX SERIES TUBE HEATER

Installation, Operation, Maintenance and Parts Manual

MX 200. MX-200 Technical Specifications FEATURES:

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Vent Supplement Ultra-80, -105, -155, -230 & -310

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

Installation and Maintenance Instructions

Installation and Maintenance Instructions

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual

Operating and Installation Instructions

GB162 Concentric Horizontal Vent Kit

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Pellet Vent INSTALLATION INSTRUCTIONS

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

LD Series Installation Manual

Mitchell Metal Products, Inc.

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS

Technical and Dimensional Data. Saf-T Vent SC Plus

COFFEE ROASTER VENTILATION HOOD INSTALLATION AND OPERATING INSTRUCTIONS

COMMON VENT DANGER: General

High Power Range Hood

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

LD3 Series Installation Manual

INSTALLATION INSTRUCTIONS

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

Installation and Maintenance Instructions

FOR YOUR SAFETY WARNING FOR YOUR SAFETY. high efficiency, separated combustion gas-fired unit heaters models PTC and BTC

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY!

VENT SYSTEM COMPONENTS

Do not use this vent pipe or fittings for venting incinerators of any kind.

Prestige Gas Vent Stainless Termination Kit

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

DuraTech. Installation Instructions. Combustion Air System

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

LS Series Installation Manual

DANGER. Direct Vent Gas Stove Installation and Operating Instructions. Models: OXDV30NVSB WARNING SAFETY BARRIER WARNING.

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

Mechanical Appliance and Equipment Inspection Checklist

Installation Instructions

VENTING APPLICATION GUIDE

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

INS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT

OPTION CA1, CA2, AND CA3 POWER VENTERS

Tankless Water Heater Direct Vent Sweet Termination Installation Instructions

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)

External Roof-mounted Power Vent System

PelletVent Multi-fuel venting system. UL 641.

Installation Instructions for PTS Chimney Liners: Ventinox /DuraFlex Pro /DuraFlex SW

Direct Exhaust Venting Kit Instructions

ZC Kit AGP Pellet Insert

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

St. Croix Greenfield Installation Manual

CWD Series. Gas-Fired Direct Vent Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Woodbridge Fireplace Inc.

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Installation Instructions

Transcription:

UH and FA Series Concentric Vent Kit Instruction Sheet Detroit Radiant Products Co. CVK-3, 4 or 6 Concentric Vent Kit Installation Instructions This instruction sheet is intended to describe the installation of the Concentric Vent Kit. This kit is designed for use with the FA and UH Series when both venting and combustion air is desired through a roof or wall penetration. Refer to the FA Series (F/N: LIOFA) or UH Series (F/N: LIOUH) manual for overall venting requirements. For additional information, please contact the factory. Verify that all parts listed under kit contents are present prior to beginning service on the unit. Concentric Vent Kit Types CVK-3 CVK-4 CVK-6 30 to 45 MBH 60 to 125 MBH 150 to 250 MBH The following installation MUST be performed by a qualified service person. Improper installation, adjustment, service or maintenance can cause property damage, injury or death. Tools Required: Drill with 1/4 Inch Driver. Tin Snips. Level. Saw. Gloves. Safety Glasses. Kit Contents: Additional Items Needed: BVP-# - 60 long doublewall B-vent (Duravent). DHC-# - B to C adapter (drafthood connector). #8 sheet metal screws. Single-wall vent pipe. Metallic tape or silicone sealant (RTV-106) approved for use at 400 F. SC-# - Storm collar (vertical venting only). Insulation (optional). Concentric Vent Box. Air Outlet Cap. Combustion Air Inlet Cap. Figure 1 Kit Contents SWD-# High Wind B-Vent Cap SK-# Pass Thru High Wind Intake Cap (Single-Wall) CVK-# Concentric Vent Box (3, 4 or 6 ) FRONT VIEW (to unit) REAR VIEW (to outside) Vent Pass-thru Pass Thru Hole Fresh Air Intake Concentric Vent Connection LSH140-7/13 (DRP)

Concentric Vent Kit Instruction Sheet UH and FA Series Specifications This concentric vent kit is specifically designed for use with FA and UH Series unit heaters only. It is the responsibility of the installer to ensure the concentric vent kit is the proper size for the unit in which it is to be installed. For more information, contact the local representative or the factory for assistance. Chart 1 Concentric Vent Kit Data Kit Part No. Heater Input Range (MBH) Intake (Single wall) Exhaust (B-Vent) Figure 2 Concentric Vent Kit Dimensions Gas-fired heaters must be properly vented at all times. Insufficient ventilation and/or improperly sealed vents may release gas into the building which could result in health problems, carbon monoxide poisoning, fire or death. Vent Pipe Sizes Concentric (Single-wall) Box Dimensions Penetration Hole Size A B C CVK-3 30-45 4 3 5 5-1/4 15 4 12 CVK-4 60-125 4 4 6 6-1/4 15 4 15 CVK-6 150-250 6 6 8 8-1/4 15 6 23 FRONT VIEW (to unit) Concentric Vent Connection (Single-wall) REAR VIEW (to outside) Exhaust Vent Pass Thru Hole Fresh Air Intake Anchor Points A SIDE VIEW C B

UH and FA Series Concentric Vent Kit Instruction Sheet Horizontal Installation (Sidewall) 1 Select the optimal location for the vent to terminate. Take into consideration external features of the building such as windows, overhangs, adjacent buildings, as well as internal features. Prepare mounting surface. 2 Cut a penetration hole through the wall according to the kit size (see Chart 1) and prepare the mounting surface for the concentric vent box. NOTE: The concentric vent box can be directly mounted to the wall, or spaced away from the wall using suitable brackets. 3 Cut a piece of single wall pipe for the connection to the concentric vent connection. Ensure that at least 6 of pipe extends beyond the external side of the wall when the box is in its final mounting position. A crimp on one side will allow for easier installation of the Pass-Thru High Wind Intake Cap (SK-#). 4 Fasten the piece of single wall pipe for connection to the concentric vent connector with at least three (3) sheet metal screws. Seal the vent with high temperature silicone sealant. 5 Insert pipe through the wall penetration and anchor the adaptor box in place. 6 Flash in, caulk, or seal the vent pipe to the external wall. Insulate concentric vent box if located in un-tempered climate or if condensation is likely to occur (insulation optional). 7 Install the Pass-Thru High Wind Intake Cap (SK-#) to the vent pipe and secure with at least three (3) sheet metal screws. Seal the connection. 8 From the inside of the building, slide the single piece of B-Vent through the concentric vent box and the hole in the high wind intake cap. 9 Install the High Wind B-Vent Cap to the B-Vent and twist to lock in place. 10 11 The following installation MUST be performed by a qualified service person. Improper installation, operation or maintenance can cause property damage, injury or death. Read and understand these supplemental instructions along with the heater s Installation, Operation, and Maintenance Manual before installing the concentric vent kit. Install a B to C adapter (draft hood adapter) onto the single piece of B-Vent to allow for connection of the flue pipe to the vent termination. Connect the flue pipe and combustion air pipe from concentric vent box to the unit heater. Follow venting instructions from the unit heater manual. All vent joints must be sealed with high temperature silicone sealant or foil tape.

Concentric Vent Kit Instruction Sheet UH and FA Series Horizontal Installation (Sidewall) Figure 3 Outside Combustion Air Sidewall Intake - Side View High Wind B-Vent Cap 6 Min. Single-Wall Pipe for Concentric Vent Single piece of B-Vent (Duravent) Single-wall Exhaust Pipe B to C Adapter (Draft Hood Connector) 6 in. Min. Fresh Air Vent Gas Pass Thru High Wind Intake Cap Concentric Vent Box Single-Wall Fresh Air Pipe

UH and FA Series Concentric Vent Kit Instruction Sheet Vertical Installation (Roof) 1 Select the optimal location for the vent to terminate. Take into consideration external features of the building such as windows, overhangs, adjacent buildings, as well as internal features Prepare mounting surface. 2 Cut a penetration hole through the roof according to the kit size (see Chart 1). 3 Mark locations for hanging points for the concentric vent box. 4 Prepare mounting of the concentric vent box. On a flat roof, box can be mounted directly to the surface. For pitched roofs, the box must be hung level from the roof using a suitable bracket or threaded rod. Insulate concentric vent box if located in un-tempered climate or if condensation is likely to occur. (insulation optional). 5 Install cone roof flashing, ensuring that the single wall pipe for the concentric vent will be vertically level. Use of a plumb-bob or 4 foot level is recommended. 6 Cut a piece of single wall pipe for the connection to the concentric vent connection. Ensure that the length of pipe of pipe extends beyond the roof cone flashing to the desired length when the box is in its final mounting position. A crimp on one side will allow for easier installation of the pass-thru high wind intake cap (SK-#). 7 Fasten the piece of single wall pipe for connection to the concentric vent connector with at least three (3) sheet metal screws. Seal the vent with high temperature silicone sealant. 8 Insert pipe through the penetration and roof cone flashing. Anchor the adaptor box in place. 9 Install single wall storm collar onto single wall pipe. 10 Install the pass through High Wind Intake Cap to the vent pipe and secure with at least three (3) sheet metal screws. Seal the connection. 11 From the inside of the building, Slide the single piece of B-Vent through the concentric vent box and the hole in the high wind intake cap. 12 Install B-Vent storm collar onto B-Vent pipe. The following installation MUST be performed by a qualified service person. Improper installation, operation or maintenance can cause property damage, injury or death. Read and understand these supplemental instructions along with the heater s Installation, Operation, and Maintenance Manual before installing the concentric vent kit. 13 Install the high wind B-Vent Cap to the B-vent and twist to lock in place. 14 Connect Vent pipe of unit to B-Vent. If using single wall pipe, install a B to C adapter (Draft Hood Adapter) onto the single piece of B-Vent to allow for connection of the flue pipe to the vent termination. 15 Connect the flue pipe and combustion air pipe from concentric vent box to the unit heater. Follow venting instructions from the unit heater manual.

Concentric Vent Kit Instruction Sheet UH and FA Series Vertical Installation (Roof) Figure 4 Outside Combustion Air Roof Intake - Side View High Wind B-Vent Cap 6 Min. B-Vent Storm Collar Pass Thru High Wind Intake Single Wall Storm Collar Single piece of B-Vent (Duravent) 24 Min.* Concentric Roof Flashing Bracket or Threaded Rod for Box Support Single-Wall Pipe for Concentric Vent Concentric Vent Box B to C Adapter (Draft Hood Connector) Single-Wall Fresh Air Pipe Single-wall Exhaust Pipe Fresh Air Vent Gas *Consult the NFPA ANSI Z223.1 Gas Vent Termination criteria if roof pitch exceeds 9:12 2014 Detroit Radiant Products Company - 21400 Hoover Road Warren, MI 48089 U.S.A. Voice: (586) 756-0950 - Fax: (586) 756-2626 - Website: www.detroitradiant.com