Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

Similar documents
4-Way Cassette type. Contents MMU-AP 2H2UL

Digital Inverter 4 series 8 & 10HP

Air to Air Heat Exchanger

Engineering Data Book

Engineering Data Book

Compact 4-way Cassette ( ) Type

Engineering Data Book

Engineering Data Book

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

DESIGN & TECHNICAL MANUAL

Engineering Data Book

DESIGN & TECHNICAL MANUAL

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Engineering Data Book

[U] Serie MHB / MHA Manual de Ingeniería

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

ELECTRICAL QUANTITY WEIGHT (LB)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

EDUS Heat Pump - D-Series

DESIGN & TECHNICAL MANUAL

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

PAJ3. Product Specifications

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

DESIGN & TECHNICAL MANUAL

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit

DESIGN & TECHNICAL MANUAL

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

DESIGN & TECHNICAL MANUAL

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

DESIGN & TECHNICAL MANUAL

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

PHD3. Product Specifications

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

[U] Serie MOV. Manual de Ingeniería

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

PAR5. Product Specifications

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

TECHNICAL DATA & SERVICE MANUAL

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

ECOi TM. Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

DESIGN & TECHNICAL MANUAL

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

DESIGN & TECHNICAL MANUAL

R4H4. Product Specifications

Transcription:

E15-3E1 MMC-AP 1H2UL Ceiling type MMC-AP0181H2UL MMC-AP0241H2UL MMC-AP0361H2UL MMC-AP0421H2UL Contents 1. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical current characteristics 7. Sensible capacity table 8. Air throw distance chart 9. Sound data 10. Accessories 1

MMC-AP 1H2UL E15-3E1 1. Specifications Ceiling type Model name MMC- AP0181H2UL AP0241H2UL AP0361H2UL AP0421H2UL Cooling Capacity kbtu/h 18 24 36 42 Heating Capacity kbtu/h 20 27 40 47.5 Electrical characteristics Power supply 230 V (208/230 V) 1phase 60 Hz Power consumption kw 0.038 0.05 0.091 0.11 Appearance White (Munsell 10Y 9.3/0.4) Height In 8.3 8.3 8.3 8.3 Unit Width In 35.8 46.5 62.8 62.8 Dimension Depth In 26.8 26.8 26.8 26.8 Height In 12.4 12.4 12.4 12.4 Packing Width In 39.1 50.0 66 66 Depth In 32.0 32.0 32.0 32.0 Total weight Heat exchanger Unit lbs 46 57 75 75 Packed unit lbs 62 75 97 97 Finned tube Fan Centrifugal fan Fan unit Standard air flow (High/Mid/Low) cfm 410/360/320 590/530/470 880/770/680 950/820/730 Motor W 60 60 120 120 Air filter Standard filter (Long life filter) Gas side In 1/2" 5/8" 5/8" 5/8" Connecting pipe Liquid side In 1/4" 3/8" 3/8" 3/8" Drain port (Nominal dia.) In VP20(Polyvinyl chloride tube: External Dia.1 Internal Dia.0.79) Sound pressure level (High/Mid/Low) (*1) db(a) 38.5/35/32.5 40.5/38/35 44/41/37 46/42.5/39.5 Option parts Drain Pump Kit Elbow Piping Kit TCB-DP22CUL TCB-KP12CUL TCB-KP22CUL Note (*1) The actual values in an external operating environment are generally higher than the indicated values due to the contribution from ambient noise. 2

E15-3E1 MMC-AP 1H2UL 2. Dimensions MMC-AP0181H2UL Hole for remote control wires(knockout) Conduit hole (Hole for power supply cable, knockout) 3.3" (84) 6.7"(170) (Hanging position) 12.6"(320) Upper pipe draw-out port(knockout) 2.1" (53) 2.8" (70) Left drain size 1.5" (39) (52) 2.0" 8.5"(216) 4.3" (110) (76) 3.0" 2.0" (50) 5.1" (130) Refrigerant pipe connecting port 1/2"(12.7) (Gas side) 26.8"(680) 8.3"(210) 6.6"(167) 4.1" (105) Pipe draw-out port(knockout) 7.9"(200)(Liquid pipe) 8.5"(216)(Gas pipe) Drain port VP20(Inner dia. 5.6" (141) 4.5"(114) 1.0"(26), hose supplied) 33.7"(855) (Hanging position) Refrigerant pipe connecting port 1/4"(6.4) (Liquid side) 3.0" 3.8" (75) (97) 5.7" (146) Drain pipe Connecting port 5.3"(135) 10.3"(262) 7.8"(197) 3.5" (90) 12.4"(316) 1.2" (31) Conduit hole(hole forpower supply cable) Conduit hole(knockout) 1.3" (32) 35.8"(910) 5.7"(145) 3.6" (92) Knockout hole 3.6"(92) 3.3" (84) 6.7"(171) Left drain pipe draw-out port(knockout) Hole for remote control wires Piping hole on the wall( 3.9"(100) hole) Wireless sensor mounting section Hanging bolt Within 2.0"(50) Ceiling surface Unit 9.8"(250) ormore 9.8"(250) ormore (Front side to be positioned horizontally.) Space required for installation and servicing 19.7"(500) or more Unit:in (mm) 3

MMC-AP 1H2UL E15-3E1 MMC-AP0241H2UL 6.7"(170) (Hanging position) 12.6"(320) Upper pipe draw-out port(knockout) Hole for remote control wires(knockout) Conduit hole (Hole for power supply cable, knockout) 3.3" (84) Left drain size 2.1" (53) 2.8" (70) 1.5" (39) (52) 2.0" 8.5"(216) 4.3" (110) (76) 3.0" 2.0" (50) 5.1" (130) 26.8"(680) 8.3"(210) 6.6"(167) 4.1" (105) Pipe draw-out port(knockout) Drain port VP20(Inner dia. 1.0"(26), hose supplied) 7.9"(200)(Liquid pipe) 8.5"(216)(Gas pipe) 5.6" (141) 4.5"(114) 44.3"(1125) (Hanging position) Refrigerant pipe connecting port 3/8"(9.5) (Liquid side) Refrigerant pipe connecting port 5/8"(15.9) (Gas side) 3.0" 3.8" (75) (97) 5.7" (146) Drain pipe Connecting port 5.3"(135) 10.3"(262) 7.8"(197) 3.5" (90) 12.4"(316) 1.2" (31) Conduit hole(hole for power supply cable) Conduit hole(knockout) 1.3" (32) 46.5"(1180) 5.7"(145) 3.6" (92) Knockout hole 3.6"(92) Hole for remote control wires 3.3" (84) 6.7"(171) Left drain pipe draw-out port(knockout) Piping hole on the wall( 3.9"(100) hole) Wireless sensor mounting section Hanging bolt Within 2.0"(50) Ceiling surface Unit 9.8"(250) or more 9.8"(250) or more (Frontsideto be positioned horizontally.) Space required for installation and servicing 19.7"(500) or more Unit:in (mm) 4

E15-3E1 MMC-AP 1H2UL MMC-AP0361H2UL, AP0421H2UL 3.3" (84) Upper pipedraw-out port(knockout) Hole for remote control wires(knockout) Conduit hole (Hole for power supply cable, knockout) 1.5" (39) 2.0" (52) 8.5"(216) 4.3" (110) (76) 3.0" 2.0" (50) 8.3"(210) 6.6"(167) 4.1" (105) Pipe draw-out port(knockout) Drain port VP20(Inner dia. 1.0"(26), hose supplied) (Hanging position) 12.6"(320) 6.7"(170) 2.1" (53) 2.8" (70) 5.1" (130) 4.5"(114) Hanging bolt Within 2.0"(50) Left drain size Ceiling surface Unit 60.6"(1540) (Hanging position) Refrigerant pipe connecting port 3/8"(9.5) (Liquid side) Refrigerant pipe connecting port 5/8"(15.9) (Gas side) 3.0" 3.8" (75) (97) 5.7" (146) Drain pipe Connecting port 5.3"(135) 10.3"(262) 7.8"(197) 3.5" (90) 12.4"(316) 26.8"(680) 1.2" (31) 7.9"(200)(Liquid pipe) 8.5"(216)(Gas pipe) 5.6" (141) Conduit hole(holeforpowersupply cable) Conduit hole(knockout) 1.3" (32) 62.8"(1595) 5.7"(145) 3.6" (92) Knockout hole 3.6"(92) Hole for remote control wires Piping hole on the wall( 3.9"(100) hole) Left drainpipe draw-out port(knockout) 3.3" (84) 6.7"(171) Wireless sensor mounting section Hanging bolt Within 2.0"(50) Ceiling surface Unit 9.8"(250) or more 9.8"(250) or more (Front side to be positioned horizontally.) Space required for installation and servicing 19.7"(500) or more Unit:in(mm) 5

MMC-AP 1H2UL E15-3E1 3. Center of gravity Model name X (In) Y (In) Z (In) Total weight (lbs) MMC-AP0181H2UL 18.1 46 MMC-AP0241H2UL 22.4 57 12.6 3.55 MMC-AP0361H2UL 30.3 75 MMC-AP0421H2UL G X X Y Z 4. Piping diagram Liquid side Gas side Strainer Capillary Tube Air heat exchanger at indoor side Pulse Motor Valve Sensor (TC2) Sensor (TCJ) Sensor (TA) Fan Fan Motor Sensor (TC1) 6

E15-3E1 MMC-AP 1H2UL 5. Wiring diagram MMC-AP0181H2UL, AP0241H2UL, AP0361H2UL, AP0421H2UL Power Supply 208/230-1-60 FM PMV MCC-1402 7

MMC-AP 1H2UL E15-3E1 6. Electrical current characteristics Type Ceiling type Model Nominal Voltage (V-Ph-Hz) Voltage Range (V) Power consumption FLA MCA MOCP Min Max kw A A A MMC-AP0181H2UL 208/230-1-60 187 253 0.038 0.4 0.5 15 MMC-AP0241H2UL 208/230-1-60 187 253 0.05 0.5 0.7 15 MMC-AP0361H2UL 208/230-1-60 187 253 0.091 0.8 1.0 15 MMC-AP0421H2UL 208/230-1-60 187 253 0.11 0.9 1.2 15 MCA: Minimum Circuit Amps MOCP: Maximum Overcurrent Protection (Amps) FLA: Full Load Amps 8

E15-3E1 MMC-AP 1H2UL 7. Sensible capacity table Ceiling type (MMC-AP 1H2UL) TC: Total capacity [Btu/h] SHC: Sensible capacity [Btu/h] unit size 018 024 036 042 outdoor air temp. FDB indoor air temp. 59 FWB 61 FWB 64 FWB 67 FWB 68 FWB 72 FWB 75 FWB 71 FDB 73 FDB 77 FDB 80 FDB 82 FDB 86 FDB 90 FDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 50 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 54 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 57 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 61 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 64 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 68 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 70 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 73 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 77 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 81 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 84 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 88 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 91 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 95 15320 11370 16030 11680 17040 12150 18000 12540 18310 12580 19470 12420 20270 11950 99 14880 11040 15570 11340 16550 11800 17480 12180 17780 12220 18910 12060 19680 11600 102 14520 10780 15200 11070 16150 11520 17060 11890 17360 11930 18460 11770 19220 11330 50 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 54 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 57 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 61 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 64 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 68 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 70 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 73 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 77 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 81 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 84 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 88 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 91 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 95 20430 15630 21370 16060 22730 16720 24000 17240 24410 17290 25960 17070 27020 16430 99 19840 15180 20750 15590 22070 16240 23300 16740 23700 16790 25210 16570 26240 15950 102 19370 14820 20260 15220 21550 15850 22750 16340 23140 16390 24610 16180 25610 15580 50 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 54 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 57 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 61 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 64 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 68 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 70 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 73 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 77 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 81 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 84 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 88 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 91 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 95 30640 22150 32060 22760 34090 23690 36000 24430 36620 24500 38930 24180 40540 23280 99 29750 21510 31130 22100 33100 23000 34960 23720 35560 23790 37800 23480 39360 22600 102 29050 21000 30390 21580 32320 22460 34130 23160 34720 23230 36910 22920 38430 22070 50 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 54 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 57 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 61 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 64 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 68 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 70 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 73 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 77 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 81 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 84 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 88 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 91 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 95 35750 26660 37400 27380 39770 28500 42000 29400 42720 29480 45420 29100 47290 28020 99 34710 25890 36320 26590 38620 27670 40780 28550 41480 28630 44100 28260 45920 27210 102 33890 25270 35460 25960 37700 27020 39820 27870 40500 27950 43060 27590 44830 26560 9

MMC-AP 1H2UL E15-3E1 8. Air throw distance chart MMC-AP0181H2UL/AP0421H2UL MMC-AP0361H2UL 6.56 (2) 9.84 ft (3 m) 3.28 (1) 3.28 (1.0) 0.98 (0.3) 1.64 (0.5) 1.64 (0.5) 0.98 (0.3) 6.56 (2) 3.28 (1) 9.84 ft (3 m) 0.98 (0.3) 3.28 (1.0) 1.64 (0.5) 0.98 (0.3) 3.28 (1) 6.56 (2) 9.84 (3) 13.1 ft (4 m) 3.28 (1) 6.56 (2) 9.84 (3) 13.1 ft (4 m) MMC-AP0241H2UL 3.28 (1) 6.56 (2) 3.28 (1.0) 0.98 (0.3) 9.84 ft (3 m) 0.98 (0.3) 1.64 (0.5) unit : [ft/s (m/s)] 3.28 (1) 6.56 (2) 9.84 (3) 13.1 ft (4 m) 10

E15-3E1 MMC-AP 1H2UL 9. Sound data 3.28 ft (1 m) 3.28 ft (1 m) Microphone MMC-AP0181H2UL Sound pressure level (db (A)) H - M - L 38.5-35-32.5 MMC-AP0241H2UL Sound pressure level (db (A)) H - M - L 40.5-38-35 90 H 90 H 80 M L 80 M L Octave band sound pressure level (db) 70 60 50 40 30 NC-70 NC-60 NC-50 NC-40 NC-30 Octave band sound pressure level (db) 70 60 50 40 30 NC-70 NC-60 NC-50 NC-40 NC-30 20 Audibility limits of continuous white level 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) NC-20 20 Audibility limits of continuous white level 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) NC-20 MMC-AP0361H2UL Sound pressure level (db (A)) H - M - L 44-41-37 MMC-AP0421H2UL Sound pressure level (db (A)) H - M - L 46-42.5-39.5 90 H 90 H Octave band sound pressure level (db) 80 70 60 50 40 30 M L NC-70 NC-60 NC-50 NC-40 NC-30 Octave band sound pressure level (db) 80 70 60 50 40 30 M L NC-70 NC-60 NC-50 NC-40 NC-30 20 Audibility limits of NC-20 continuous white level 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 20 Audibility limits of NC-20 continuous white level 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 11

MMC-AP 1H2UL E15-3E1 10. Accessories Elbow piping kit TCB-KP12CUL TCB-KP22CUL Drain pump kit TCB-DP22CUL Parts Name Model name Applied Model Notes Remarks Drain pump kit TCB-DP22CUL MMC-AP 1H2UL Stand-up 600 or less (from bottom face of ceiling) Use with TCB-KP12CUL and TCB-KP22CUL Elbow piping kit TCB-KP12CUL MMC-AP0181H2UL Needed when drain TCB-KP22CUL MMC-AP0241H2UL pump kit is used to 0421H2UL 12

MEMO

MEMO

MEMO

Ceiling type Engineering Data Book Model name: MMC-AP 1H2UL March, 2016 First Edition