Acoustic Sensors. Title page without bleed in RGB SITRANS AS100. Operating Instructions

Similar documents
Instruction Manual April sitrans AS 100

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

Instruction Manual August sitrans CU 02

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Quick Start Manual July pointek CLS100

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Instruction Manual December 2001 ENACOCU02

CU-02 with Senaco Plus

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Functional Safety Manual June pointek CLS500/LC500

Is your process protected?

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Snifter ATEX22 VERSION. User Manual. Distributor

Operating Instructions Edition 02/2007

OPTIWAVE X500 Supplementary Instructions

Level Measurement Continuous level measurement Ultrasonic transmitters

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Motion Sensors. Milltronics MFA 4p. Operating Instructions

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Process Protection. 6/2 Product overview. 6/3 Acoustic and Motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400

Level Measurement Continuous level measurement - Ultrasonic transmitters

Certificate of Compliance

Process Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit

OPTIBAR DP 7060 Supplementary Instructions

Certificate of Compliance

MODEL 6430T, 6460 & 6460T POTATO PEELER

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

Ultrasonic Flowmeters SITRANS F US SONO Operating instructions 01/2010 SITRANS F

Square D Clipsal Outdoor Light-Level Sensor

Survey of electrical equipment installed in hazardous areas on tankers

Installation Instructions

multiranger 100 / 200

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Silverware Pre-washing System INSTALLATION

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Installation guide 864 MTT Multi Thermo sensor Thermometer

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Installation Instructions

VERSAFLOW VORTEX Supplementary instructions

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

SITRANS Pressure transmitter SITRANS LH300 (7MF1575..) Transmitter for hydrostatic level Compact Operating Instructions

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Lamp Supply (Recommended)

AVANI Grinding Booth

Explosion Protection Enclosure with integrated measuring system

Continuous level measurement Ultrasonic transmitters

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

SITRANS. Temperature sensors SITRANS TSinsert/TS100/TS200/ TS500. Introduction 1. Safety information 2. Description 3. Installation 4.

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Manual Power relay SR853

Cabinet design and EMC SINAMICS. SINAMICS G130 Cabinet design and EMC. Safety information 1. General. Basic information about EMC 3

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

OilSET-1000 (12 VDC)

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Electrical Safety Requirements

INSTALLATION GUIDE Steamer Module

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

OPTIBAR P 1010/2010 C Supplementary instructions

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

INSTRUCTION MANUAL TABLE OF CONTENTS

Explosion Proof Line Powered Telephone Ringer

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Flameproof Manual Call Points

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Dräger Polytron 8700 IR Detection of flammable gases and vapors

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer

User s Manual YTA610 and YTA710 NEPSI Certification

INSTALLATION GUIDE Fryer Module

Greentrol Automation, Inc.

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Gas cylinder scale Model GCS-1

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

SAVE THESE INSTRUCTIONS

INSTRUCTION & SERVICE MANUAL

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Transcription:

Bufferzone Title page without bleed in RGB Find any font sizes for the text fields in the Panel "Paragraph styles"! The image must not touch with the Bufferzone. Background coolgray 20%, without history Image should come behind the bar so that the transparency comes to the fore. Do not change the transparency of the bar! 8 mm 8 mm Acoustic Sensors Operating Instructions Siemens Serif OT, Semibold, 36/30/26 PT, weiss Absatzformat: 01 System 36/30/26 pt Siemens Sans OT, Bold, 18/15/13 PT, weiss Absatzformat: 02 Produkt 18/15/13 pt Siemens Sans OT, Bold, 13/11 PT, weiss Absatzformat: 03 Titel 13/11 pt Siemens Sans OT, Bold, 13 PT, weiss Absatzformat: 04 Dokuklasse 13 pt A text area at the top is (big bar) 2-Spaltig, so the text extends upwards! Then adjust the transparent beams according to and while holding the 8 mm distance from text. I think this means that, if you need to add more lines of text, extend the big bar upwards, while maintaining the proper distance from the text. The lower pane (smal bar, Dokuklasse) must be only single-column! Natural Blue dark CoolGray 100% Edition 06/2016 Siemens Sans OT, Bold, 11/7,5 pt, weiss Absatzformat: 05 Ausgabe 11/7,5 pt Siemens Sans OT, Bold, 13 PT, schwarz Absatzformat: 06 SectorClaim 13 pt 60 mm Horizont immer auf 60 mm

Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user s agent. All new components are to be provided by Siemens. Restrict repair to faulty components only. Do not reuse faulty components. Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications. Copyright Siemens AG 2016. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens. Siemens will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. European Authorized Representative Siemens AG Industry Sector 76181 Karlsruhe Deutschland For a selection of Siemens level measurement manuals, go to: www. siemens.com/processautomation. Select Products & Systems, then under Process Instrumentation, select Level Measurement. Manual archives can be found on the Support page by product family. For a selection of Siemens weighing manuals, go to: www. siemens.com/processautomation. Under Products & Systems, select Weighing and Batching Systems. Manual archives can be found on the Support page by product family. Siemens AG 2016

Acoustic Sensors Operating Instructions General Information 1 Specifications 2 Outline and Dimensions 3 Installation 4 Mounting 5 Interconnection 6 Applications 7 06/2016 A5E31952194-AB

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY Document order number: A5E31952194 P 11/2016 Subject to change Copyright Siemens AG 2016. All rights reserved

Table of contents 1 General Information... 5 2 Specifications... 7 3 Outline and Dimensions... 9 4 Installation... 15 5 Mounting... 17 6 Interconnection... 21 7 Applications... 25 Index... 29 Operating Instructions, 06/2016, A5E31952194-AB 3

Table of contents 4 Operating Instructions, 06/2016, A5E31952194-AB

General Information 1 Sensor is an acoustic sensor for flow detection. It monitors high frequency acoustic emissions (sound waves) generated by: the friction and impact of solids flow in pipes, chutes, and conveyors cavitation occurring in pumps, pipes, and valves turbulence of gases or liquids leaking through valves and flanges friction and jarring of mechanical parts Acoustic emissions travel readily through solid materials such as metal, but are strongly attenuated when traveling through air. As such, the Sensor is immune to airborne interferences and provides a non-invasive method of monitoring process activities. The sensor can be configured electrically during wiring to operate in either low or high sensitivity range mode. The high sensitivity range applies where highest signal levels vary up to 40 db. The low sensitivity range applies where highest signal levels vary between 28 and 68 db. Sensor provides an analog output for use with the Sitrans Control Unit. The Sensor may be operated independently from the Control Unit by providing an external supply. The output is fed into a control panel, chart recorder, data logger, or programmable logic controller with a suitable input. Sensor is primarily used for solids flow detection. However, this device can be used in pump cavitation and fluid leak detection, provided sufficient noise levels are generated. Note The is to be used only in the manner outlined in this manual This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications Features non-invasive screw in, bolt on, weld, or bond in place analog output high and low sensitivity range of operation Operating Instructions, 06/2016, A5E31952194-AB 5

General Information 6 Operating Instructions, 06/2016, A5E31952194-AB

Specifications 2 Model standard extended standard operating temperature range (see below) extended operating temperature range (see below) Power 20 to 30 V DC 18 ma typical Operating Temperature standard -20 to 80 C (-4 to 176 F) 1 extended: -30 to 120 C (-22 to 248 F) 2 or -40 to 125 C (-40 to 257 F) 3 Note 1 Available for CSA/FM Class II, ATEX versions 2 Available only for CSA Class II version 3 Not available for hazardous rated versions Relative Sensitivity 0.5% / C of reading, average over the operating range Output analog, 0.08 to 10 V DC nominal, 100 KΩ minimum load impedance Operating Instructions, 06/2016, A5E31952194-AB 7

Specifications Construction housing cable 304 stainless steel 303 stainless steel (CSA/FM Class II, ATEX II 3D version) aluminum (ATEX II 2GD version) standard: 4 m (13 ft) cable, PVC jacketed, 3 twisted pairs, 24 AWG, shielded extended: 4 m (13 ft) cable, thermoplastic elastomer jacketed, 6 conductor, 24 AWG conductor, shielded Ingress Protection IP68 (waterproof) The IP68 test was performed by immersing the enclosure in 1.8 m of water for 30 minutes. Weight 0.4 kg (1 lb.) 1.2 kg (2.65 lb.) (ATEX II 2GD version) Approvals General Hazardous Europe: US: Canada: CE, C-TICK, KCC ATEX II 2GD Ex II 2G Ex d IIC T4 Gb Ex II 2D Ex tb IIC T100 C Db DEKRA cert #: DEKRA 13ATEX0006 X Standards: 60079-0 : 2009, EN 60079-1 : 2007 and EN 60079-31 : 2009 ATEX II 3D FM Class II, Div. 1, Groups E, F, G CSA Class II, Div. 1, Groups E, F, G 8 Operating Instructions, 06/2016, A5E31952194-AB

Outline and Dimensions 3 (ST and ET versions) 1 6 x 24 AWG cable 2 Mounting post, 17A/F nut and M10 thread Operating Instructions, 06/2016, A5E31952194-AB 9

Outline and Dimensions (CSA/FM Class II Rated ST and ET versions) 1 6 x 24 AWG cable 2 ½" NPT (CSA and FM approvals) or M20 (ATEX approval) female conduit fitting 3 Mounting post, 17A/F nut and M10 thread 10 Operating Instructions, 06/2016, A5E31952194-AB

Outline and Dimensions (ATEX II 2GD version) WARNING Do not open when an explosive atmosphere is present. Possible static hazard. Do not rub or clean the product on site. 1 Cable entry (2) M20 x 1.5 2 Enclosure Operating Instructions, 06/2016, A5E31952194-AB 11

Outline and Dimensions Accessories Extension Tab (optional, not available for ATEX II 2GD version) 1 mounting hole M10 thread 2 Bolt hole, 14mm (0.55")Ø 12 Operating Instructions, 06/2016, A5E31952194-AB

Outline and Dimensions Mounting Disc (optional, not available for ATEX II 2GD version) 1 mounting hole M10 thread Note Both Tab and Disc are 304SS. Operating Instructions, 06/2016, A5E31952194-AB 13

Outline and Dimensions 14 Operating Instructions, 06/2016, A5E31952194-AB

Installation 4 Ideal Locations areas where the acoustic emission levels are highest and most consistent where the material impact is greatest areas closest to the point of leakage (e.g. valve body) closest point to source of cavitation (e.g. pump body) Conditions to Avoid non-metallic surfaces, as these tend to attenuate acoustic emission levels pipes with non-metallic liners as these tend to attenuate acoustic emission levels Conditions to Consider joints and interfaces attenuate the acoustic emission levels. minimal temperature variation where acoustic emission levels are weak. location should provide sufficient response time in alarm or control circuit. e.g. loss of bearing lubrication, plug chute detection. Operating Instructions, 06/2016, A5E31952194-AB 15

Installation Solids Flow Sensing Recommended Not Recommended Good friction between product and piping. Mount Sensor on the upstream side of gasket for highest level of acoustic emission activity. Minimal amount of acoustic emission activity due to limited friction between product and piping. 16 Operating Instructions, 06/2016, A5E31952194-AB

Mounting 5 Note To ensure the most ideal location, test the by clamping the Sensor to the application, and running a trial period to determine the system's performance. The acoustic emission level can be monitored by a voltmeter across the analog output. Refer to Interconnection (Page 21). Coating the contact surfaces with grease enhances the propagation of acoustic emissions to the Sensor. Mounting Method Clearance hole Drill and Tap Mounting Disc Extension Tab Acoustic Coupling and Sensitivity Good Good Good Fair Direct Mounting Clearance Hole Drill and Tap Contact Insert mounting post through hole in device being monitored and fasten with customersupplied washers and nut. Screw mounting post into threaded hole in device being monitored. Weld or bond mounting post to device being monitored. When welding, first remove the acoustic sensor from the housing. Note To ensure proper coupling, the face of the Sensor nut must be tight to the application surface. Operating Instructions, 06/2016, A5E31952194-AB 17

Mounting Accessory Mounting Extension Tab Screw Sensor into threaded hole of tab, and fasten onto device being monitored. Mounting Disc Screw Sensor into disc, after welding or bonding disc onto device being monitored. Note If welding, weld must be a continuous bead. Tacking does not provide sufficient acoustical coupling. Do not arc weld on equipent connected to a. Remove the SITRANS AS100 or disconnect electrically to avoid current flowing through the sensor. If gluing, use Loctite 326 adhesive, or equivalent. Follow manufacturer s instructions to ensure proper adhesion. 18 Operating Instructions, 06/2016, A5E31952194-AB

Mounting Figure 5-1 Cable Gland (optional for use with ATEX II 2GD version) 1 Rubber component 2 Foil Jacket 3 Sleeve 4 Cable with outer jacket The ATEX II 2GD version is supplied with an approved cable gland. Installation of glands/ conduit must conform to local governing codes. 1. Disassemble the cable gland and discard the plastic membrane inside. 2. Route the cable into the M20 section of the gland and thread it onto the housing. 3. Mark the cable 2 (50 mm) from the entry of the housing then remove the acoustic sensor from the housing. 4. Remove the outer jacket of the cable from the acoustic sensor to the mark on the cable. 5. Reinstall the acoustic sensor into the housing and route the cable through the M20 section and into the throat of the rubber component. 6. Peel back the foil jacket (on the cable) over the tapered steel (connected to the rubber component). 7. Install the sleeve over the tapered steel part, and thread the remaining two parts of the gland onto the cable. 8. Tighten the assembly to ensure a seal of the gland over the cable with outer jacket. Operating Instructions, 06/2016, A5E31952194-AB 19

Mounting Temperature Considerations WARNING Temperature at Sensor must not exceed minimum or maximum ratings. Ensure adequate isolation from hot surfaces by providing additional spacing. Note For standard Temperature range model, maximum temperature is 80 C. Tab acts as heat sink. Note If the flange temperature is 100 C and the ambient temperature is 20 C, the Sensor temperature at the electronics is below the maximum rating. *maximum range dependent on model. 20 Operating Instructions, 06/2016, A5E31952194-AB

Interconnection 6 Standard Temperature Version (ST) 1 Vsup: 20 to 30 V DC supply input 2 Vsens: analog output 0.08 to 10 V DC nominal 3 shield--tied to Sensor casing *Sensor range selection high sensitivity range = red and green to Vsup + low sensitivity range = red to Vsup + and green to Vsup - Operating Instructions, 06/2016, A5E31952194-AB 21

Interconnection Extended Temperature Version (ET) 1 Vsup: 20 to 30 V DC supply input 2 Vsens: Analog output 0.08 to 10 V DC nominal 3 shield--tied to Sensor casing *Sensor range selection high sensitivity range = red and orange to Vsup + low sensitivity range = red to Vsup + and orange to Vsup - Note Connect shield to ground at one end only! If Sensor mounting is grounded, leave cable shield disconnected If Sensor mounting is not grounded, connect cable shield to ground The longer the cable, the more susceptible it is to noise and earth loops. We recommended using cable with heavy gauge conductors and good RF/electrical shielding (copper braid rather than drain and foil). A proper junction box close to the sensor is an ideal location not only to extend the cable, but to also to configure the wiring for high or low sensitivity range operation. This table provides a guideline for suitable wire gauges where distances are considerable. Maximum distance between Sensor and supply (24V or Control Unit) wire size distance AWG mm mm 2 * meters feet 24 7 x 0.20 0.22 500 1600 22 7 x 0.25 0.35 800 2600 20 10 x 0.25 0.5 1200 3900 * nominal wire size 22 Operating Instructions, 06/2016, A5E31952194-AB

Interconnection Analog Output The Sensor provides an analog output proportional to the level of acoustic emission activity. As the level of acoustic emission activity is a relatively good indication of process or mechanical activity, the output is suitable as an input to devices such as dataloggers chart recorders and programmable logic controllers. The output is 0.08 to 10V (nominal), dc coupled, short circuit protected with a 60 μs timeconstant. The minimum load impedance is 100 KΩ. Refer to Installation. (Page 15) Relative Sensitivity The sensitivity of acoustic emission is affected by temperature. In most applications this is not a concern when considering the much greater changes in signal level due to changes in flow. However, it is important to be aware of the effect. The sensitivity of the Sensor decreases with increasing temperatures at a rate of approximately 0.5% per degree Celsius. For example, if the temperature of the standard Sensor increased from 20 C to 50 C, its sensitivity would decrease by 15%. If the Sensor were to be used to monitor flow changes over such a temperature range, you should set an associated alarm setpoint at least 30% away from the normal operating level measured at 20 C. Operating Instructions, 06/2016, A5E31952194-AB 23

Interconnection 24 Operating Instructions, 06/2016, A5E31952194-AB

Applications 7 Pneumatic Conveyor A tanker load of bulk solid material is being pneumatically conveyed into a silo. The Sensor detects the acoustic emissions generated by the particles impacting against the pipe wall and the output is used to activate the silo dust filter system. Recommended location is any impact point along the line, such as an elbow. Screw Conveyor Discharge A fibrous material is being delivered to a pelletiser by means of a screw feeder. When loss of flow is detected by the Sensor, an alarm in the control room informs the operator of a possible blockage. Recommended location is any point along the under side of chute, where there is friction due to the flow of material. Operating Instructions, 06/2016, A5E31952194-AB 25

Applications Diverter Gate The process material is stored in a hopper and fed into the process through a diverter gate. A Sensor mounted to each leg of the diverter indicates the presence or absence of flow in the open leg. Low alarm gives early indication of problems in the diverter gate or slide gate, or of blockage or material shortage in the hopper. Leak detection 26 Operating Instructions, 06/2016, A5E31952194-AB

Applications Cavitation Monitoring Install the Sensor in B either A or B locations. Machine Condition Monitoring Install the Sensor in either A or B locations. Operating Instructions, 06/2016, A5E31952194-AB 27

Applications Manufactured Date To identify when the product was built use the tables below based on the serial number on the product. Company/Plant code Separator Year of MFG. Month of MFG. Serial Number Scheme Day of MFG. 4 digit sequential # (0000 to 9999) PBD / S 1 0 1 0 0 0 1 PBD / S 1 0 1 0 0 0 2 PBD / S 1 0 1 0 0 0 3 Refer to following tables for encoding formats. Encoding of Letters Year of Manufacture (one character alpha entry) Year 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 ALPHA CODE M N P R S T U V W X Year 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 ALPHA CODE A B C D E F H J K L Month of Manufacture (one character alpha or numeric entry) Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sept. Oct. Nov. Dec. 1 2 3 4 5 6 7 8 9 0 N D Day of Manufacture (two character numerical entry) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 28 Operating Instructions, 06/2016, A5E31952194-AB

Index A Accessories, 12 Accessory Mounting, 18 Analog Output, 23 C Cavitation Monitoring, 27 Conditions to Avoid, 15 Conditions to Consider, 15 S Screw Conveyor Discharge, 25 (ATEX II 2GD version), 11 (CSA/FM Class II Rated ST and ET versions), 10 (ST and ET versions), 9 Sensor, 5 Standard Temperature Version (ST), 21 Solids Flow Sensing, 16 D Direct Mounting, 17 Diverter Gate, 26 T Temperature Considerations, 20 E Extended Temperature Version (ET), 22 I Ideal Locations, 15 L Leak detection, 26 M Machine Condition Monitoring, 27 Manufactured Date, 28 Mounting Disc (optional, not available for ATEX II 2GD version), 13 P Pneumatic Conveyor, 25 R Relative Sensitivity, 23 Operating Instructions, 06/2016, A5E31952194-AB 29

Index 30 Operating Instructions, 06/2016, A5E31952194-AB

Letter without trimming Find any font sizes for the text fields in the Panel "Paragraph styles"! Background coolgray 100 %, Siemens Sans OT, Bold, 13 PT, schwarz Absatzformat: 01 Weitere Info 13 pt Siemens Sans OT, Roman, 9 PT, schwarz Absatzformat: 01 Info Text 9 pt Siemens Sans OT, Bold, 9 PT, schwarz Absatzformat: 01 Info Link 9 pt For more information www.siemens.com/level www.siemens.com/weighing Texts are filled from bottom to top 12 mm Bufferzone 12 mm Bufferzone Siemens Canada Limited 1954 Technology DriveSiemens Sans OT, Roman, 7,5 PT, schwarz P.O. Box 4225 Absatzformat: 02 Adresse 7,5 Subject pt to change without prior notice Peterborough, ON A5E31952194 Rev. AB Canada K9J 7B1 Siemens AG 2016 Siemens Sans OT, Bold, 9 PT, schwarz Absatzformat: 03 siemens.com 9 pt www.siemens.com/processautomation 11 mm 48 mm 66 mm Printed in Canada Bereich für Codes 60 mm Horizont immer auf 60 mm