Operational Safety in the underground facilities of a deep geological disposal of nuclear waste

Similar documents
Y. ORMIERES. Fire risk analysis method for nuclear installations

Lata Mishra Bhabha Atomic Research Centre, INDIA

FIRE PROTECTION REGULATION AND EXPERIENCE FIRE PROTECTION IN INDONESIA. Agus Waluyo Indonesian Nuclear Energy Regulatory Agency

30 top tips to tackle HVAC challenges No.21 - Fireman s override

Top tip No. 21 Fireman s override

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Smoke detection in hazardous areas:

CHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS

NATIONAL COMPETENCY STANDARD

Research Needs for the Fire Safety Engineering Profession

Fire Protection Approaches and Experiences in NPP

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

FIRE PROTECTION ISSUES IN THE HOT CELLS OF A NUCLEAR FACILITY

FIRE RESISTANCE OF ROLLING STOCK ELEMENTS STANDARD AND SPECIAL CASE OF TUNNELS

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

Modeling the Underground Ventilation System at the Waste Isolation Pilot Plant to Ensure Proper Ventilation Alignment

- CONSTRUCTION FIRE SAFETY STANDARDS

Delhi Metro System. Emergency and Fire Safety Measures in. - by Sanjeev Kumar & Kailash Chandra Joshi. Fire Protection & Safety

Technical Information

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Fire Safety Checklist

DEEP GEOLOGIC REPOSITORY PROJECT JOINT REVIEW PANEL RESPONSE TO INFORMATION REQUEST EIS

Case Study of Underground Car Park. Team Japan

PHASED CONSTRUCTION AND SAFETY IN MALA KAPELA TUNNEL

GASEOUS HYDROGEN SYSTEMS

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

ITER Fire Safety Approach

- CONSTRUCTION FIRE SAFETY STANDARDS

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER C: DESIGN BASIS AND GENERAL LAYOUT

Safety Manual Section 7 Fire/Life Safety

3.1 Introduction. 3.1 Introduction

Fire protection on chemical manufacturing sites

Division III Process Gas Treatment Equipment

Protection against Internal Hazards in the Design of Nuclear Power Plants

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

Protection against Internal Hazards in the Design of Nuclear Power Plants

DSEAR - Requirements

Crossrail. Clare Hebden; September 2012

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Safety Security Interface (SSI) at Bhabha Atomic Research Centre, Mumbai, India

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Foam Products ENGLISH

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

Fire Protection Coffee Break Training May 2016

Agency for Health Care Administration

Sprinkler systems. A presentation for fire brigade staff

Soot Mitigation Strategies

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

REFERENCES TO ICC ELECTRICAL CODE - ADMINISTRATIVE PROVISIONS IN THE INTERNATIONAL BUILDING CODE

LABORATORY SAFETY SERIES: Flammables & Explosives

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

INITIAL FIRE ASSESSMENT REPORT (FAR)

Edward K. Budnick Hughes Associates, Inc. Wheaton, Maryland, U.S.A SUMMARY. that is entrained or otherwise mixed into the mass.

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

Florida International University. Biosafety Cabinet Program

Fire outbreak inside a warehouse 5 December 2013 Crépy-En-Valois (Oise) France

ASPECTS OF FIRE SAFETY IN ULTRA HIGHRISE BUILDINGS

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

FACADES AND FIRE The Essential Elements

WARM WELCOME RISK ASSESSMENTS & HOMESTAY FIRE/GAS SAFETY

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Modeling a real backdraft incident fire

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Building Fire Safety Regulation 2008

EMERGENCY VENTILATION FOR SMOKE CONTROL IN ROADWAY TUNNELS (NCHRP PROJECT TASK 363)

Essentials of Fire Fighting 6 th Edition Firefighter I

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

Element C3.5 Means of Escape

automatic FiReFighTing SYSTeMS in PainT booths

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

Max Fire Box Users Guide

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Case Study 1 Underground Car Park

White Paper EXPLOSION PROTECTION EXPLOSION PROTECTION SOLUTIONS FOR SANITARY HYGIENIC APPLICATIONS IN THE FOOD & PHARMACEUTICAL INDUSTRY

INITIAL FIRE SAFETY ASSESSMENT

C4.8 Fire Protection Regulations

Unit 2 Fire Safety (Zone 2)

BaBar Fire Hazards Analysis. Executive Summary

MINISTERIAL ORDER NO.(6) OF 2013 WITH RESPECT TO PROTECTION OF WORKERS FROM THE HAZARDS OF FIRE IN ESTABLISHMENTS AND WORK SITES

Loss Prevention Standards

Crossrail Fire Safety Designs

INITIAL FIRE SAFETY ASSESSMENT

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Development of Post-Accident Monitoring System for Severe Accidents

CHAPTER 7 ALTERATIONS LEVEL

COMMISSION REGULATION (EU)

Transcription:

Operational Safety in the underground facilities of a deep geological disposal of nuclear waste Denis DE WINTER, David CLAUDEL, Olivier CITE

General presentation Cigéo Project 2012 Preliminary design 2

Radioactive waste to be disposed of in underground disposal facility HLW: 10,000 m 3 59 French nuclear reactors Processing of spent fuel Technology waste, research activities and legacy waste A variety of waste types IL-LLW: 70,000 m 3 3

The Cigéo project The underground facility is hosted 500 m deep in thick argillite (hard clay) formation Surface Facilities Waste preparation facility Waste transfer ramp and service ramp HLW disposal 2025-2040 Construction support facility Ventilation and service shafts HLW disposal 2075-2140 U/G facilities ILW disposal 2025-2085 4 2012 Preliminary design

HLW disposal packages High Level Waste (HLW) will be placed in thick steel overpacks Handling Interface Ceramic skids for easy handling Vitrified HLW Stainless Canister 5

HLW Disposal Cells High Level waste (HLW )will be disposed of in steel lined micro-tunnels Excavation Ø 0,70 m Steel sleeve Spacer Disposal package Steel overpack 6

IL-LLW disposal packages Intermediate Level Long lived Waste will be placed in precast reinforced concrete containers Concrete cover Concrete box Primary waste package 7

IL-LLW disposal cells IL-LLW will be disposed of in horizontal tunnels excavation Ø ~ 9 m concrete Lining ILW disposal package Remotely operated fork lift Disposal chamber (400 m long) transport cask Handling chamber Access gallery 8

Construction and operation Cigéo Project 9

Construction and operation Cigéo is a unique project Large underground facility (120 km tunnels, 160 km microtunnels) Will be constructed, operated and closed over a very long period (~120 years) Construction and operation will take place simultaneously Operation is a nuclear operation with highly radioactive material (use of steel shields >10 cm thick) Reversibility Ability to retrieve waste packages for at least 100 years Step by step, flexible development 10

Main design principles Each category of waste in a separate zone HLW IL-LLW Keep construction area and operation area separate Separate access facilities Separate power and information network Separate ventilation system Generally speaking, an incident in one area should have minimal consequence on the other area 11

Development of project Twin tube design for higher safety and service Emergency access and exit possible within each area Electrical and data network can be doubled in separate galleries Nuclear area Nuclear ventilation Construction area 12

Development of project Nuclear area Nuclear ventilation Construction area 13

Development of project Nuclear area Nuclear ventilation Construction area 14

Development of project Nuclear area Nuclear ventilation Construction area Closed area 15

Development of project Nuclear area Nuclear ventilation Construction area Closed area 16

Development of project Nuclear area Nuclear ventilation Construction area Closed area 17

Development of project Nuclear area Nuclear ventilation Construction area Closed area 18

Operational Safety The Cigéo Andra Fire Guidelines 19

The fire risk : Cigéo fire guidelines Two apparently divergent approaches : Nuclear approach Fire + presence of Toxic, Radioactive, Flammable, Corrosive, and Explosive products => Fire barriers and confinement to prevent contamination by dangerous products Underground construction/tunnel approach Fire + presence of persons => Smoke extraction to allow evacuation of persons and action of firemen No existing regulation covering all aspects of Cigéo fire risk Necessity of reconciling these two approaches to draw up the Cigéo fire guidelines The guidelines have been set up by Andra with the contribution of fire experts from nuclear operators (AREVA, CEA, EDF) and from various bodies including the institute for industrial risks (INERIS), the center for tunnel studies (CETU) and firemen. 20

Objectives and Functional Requirements to be reached Objectives OS 1: Protection of the live and health of the persons present in the installations OS 2: Preservation of the environment (including protection of the nearby population) OS 3: Maintaining safety functions OS 4: Maintaining the industrial activities and the installations Declined into sub-objectives and associated requirements Performance criteria are proposed for each of the identified requirements Wherever possible, a specific reference value is used. It is issued from Applicable regulations, if available, Or the other guideline texts, Or the feedback from experience and the experts opinions. For example Requirements in connection with personnel possibility of evacuating, distance of evacuation (400m maximum), fire resistance of the galleries more than the evacuation duration in terms of structures resistance, flame and warm gas tightness In the absence of complete applicable regulations, all theses reference values will have to be justified to the regulators (Nuclear Authority, Civil Protection Authorities) 21

Further Requirements to Take into account the Specificity of the Cigeo Underground Installations Apply the principle of defence-in-depth commonly used in the nuclear industry 1 st line of defence : minimize the risk of any start of fire and its spreading : Limitation of the fire load when designing the fixed and mobile equipments, For example, transfer of nuclear waste using Cable car in the ramp Electrically powered Rail system in horizontal galleries Limitation of the areas having a high fire risk For example limitation of underground maintenance shops and storage areas as much as practically achievable 2 nd line of defence : detection of fire and early fire fighting : Implementation of detection devices as close as possible to the potential hazard sources (in order to have a reduced time of reaction) Implementation of fire-fighting systems to limit the spreading of fire For example, in board automatic fire fighting system on vehicles 3 rd line of defence : control of fire and limitation of its consequences : To be implemented according to the reference fires and the selected envelope scenarios : Ventilation and smoke extraction systems, managed from a central control room Presence of fire compartments, especially for areas entailing a risk of radioactive substances dispersion or for areas presenting a major fire hazard electrical rooms for example, which feature major fire loads and ignition sources Presence of passageways to evacuate persons and to enable access for fire-fighting and rescue teams 22

Ventilation Cigéo Project 23

Design Principle Applicable to Ventilation o o o General Separation of ventilation flows between «construction area» & «nuclear area», Main ventilation plants near the head of shafts and ramps, IL-LLW* Disposal Cells have been classified «Containment Class C2***» as a function of the risk of accidental dispersion of radioactive material filtration and separation (air duct) of ventilation flows exhausted from the cell In normal operation nuclear area : air intake provided through full section of galleries air exhausted through air duct (HLW** zone) or dedicated gallery (IL-LLW zone) construction area : air intake provided through full section of galleries + secondary air ducts air exhausted through air ducts In case of fire Underground design includes patterns of parallel galleries. These galleries are interconnected, thus providing a smoke free escape route to the personnel and access for firefighting and rescue operations. *Intermediate Level Long Life Waste, **High Level Waste. ***Containment Class C2 implies the use of HEPA (High Efficiency Particular Air) filters 24

Ventilation General Design (nuclear and construction areas) Nuclear shafts Construction shafts Nuclear ramps Nuclear area Nuclear ventilation Construction area Fresh air (full face) Nuclear exhaust air Construction exhaust air 25

Ventilation in normal operation in IL-LLW zone (nuclear area and construction area) Construction area Fresh air (full face) Nuclear exhaust air Construction exhaust air Nuclear area Separate air flows for Construction area and Nuclear area Full section ventilation Air from the disposal cell cleaned by HEPA 1 filter Air exhausted through ventilation gallery surrounding the disposal zone & linked to a central exhaust air shaft 1 High Efficiency Particulate Air 26

Fire case study (access gallery in nuclear area) in IL-LLW zone Construction area Fresh air (full face) Nuclear exhaust air Construction exhaust air Nuclear area Subdivision of gallery in compartments using fire doors (maximum length of compartment 800 m) Ventilation stopped in neighbouring disposal cells Smoke extraction via duct installed at the top of each gallery Air intake through door and/or connection gallery Escape of personnel through connection drifts into smoke free gallery Access of firemen through door and/or connection gallery 27

Fire case study (disposal cell) in IL-LLW zone Construction area Fresh air (full face) Nuclear exhaust air Construction exhaust air Nuclear area Scenario : fire in disposal cell No personnel in disposal cell No access for firemen in disposal cell Closure of air shutters at inlet & outlet of disposal cell in order to contain the fire 28