Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Environmental Stress Chamber

Compact design for personal use Ready to network with your computer.

Bench-Top Type Temperature (& Humidity) Chamber

Thermal Shock Chambers

Thermal Shock Chambers

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

Environmental Stress Chamber

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Thermal Shock Chambers TSA Series

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Platinous J Series CAT.NO.E15110-Y1612

Highly Accelerated Stress Test System (HAST Chamber)

Battery Charge/Discharge Test System Integrated with Temperature Chamber

Temperature Chamber Series

Environmental Chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Walk-In Type Temperature (& Humidity) Chamber E Series

Walk-In Type Temperature (& Humidity) Chamber E Series

Temperature Chamber Series

Benchtop Test Chambers. Temperature and Humidity

Temperature Cycling Chambers Global-N Series

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

The best test chambers...

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Environmental Chambers

Benchtop Test Chambers Temperature and Humidity

The best test chambers...

Chapter 5 Inspection and maintenance

Chapter 8 Troubleshooting

Chapter 5 Inspection and maintenance

Technical Specification of High and Low Temperature Altitude Test Chamber

Chapter 8 Troubleshooting

Customized Industrial Products

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

TCC-34. Features: TISSUE CULTURE

Daily maintenance and checks

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Chapter 7 Troubleshooting

Reproducible Climate...

TCR. Features: TISSUE CULTURE

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

Environmental.

SPC-56 SHORT PLANT.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Constant climate chambers

UV Weather Resistance Test Chamber Technical Data

Constant climate chambers

Constant climate chamber with humidity

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

KMF Environmental test chamber for constant climate

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Refrigerated Incubators / Environmental Testing Chambers

Remote Conditioners. RC-Series. ZPRC Series

Chapter 7 Checks and Maintenance

Constant climate chamber with ICH-compliant illumination

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.


Freezers. Upright Laboratory & Plasma. i.series Horizon Series

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

FITOCLIMA 600 & 1200 STABILITY

Benchtop & Compact Test Chambers

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Freezers. Laboratory & Plasma. i.series Horizon Series

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

SPC-7-2H SHORT PLANT.

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

IndigoVision Alarm Panel. User Guide

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Stability Chambers & Rooms

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

incubator, the best in its class

FITOCLIMA 600 & 1200 STABILITY

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Constant climate chambers

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Environmental simulation chamber for complex alternating climate profiles

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

DESIGN & TECHNICAL MANUAL

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

Transcription:

Faster Temperature (& Humidity) Chamber SM series CAT.No.E17129

Stress of 5 /min. achieved with the large-capacity 1800L models. The faster 1800L temperature and humidity chamber can handle the reliability testing of large display devices used in automotive components, car electronics systems and other devices. The chamber can achieve a temperature change rate of 5 /min, and in addition to making specimen setting easier, it now allows for central control and remote monitoring via an internet browser. 1

2

Characteristics Temperature & Humidity Control Range 100 90 80 Relative 70 Humidity 60 (%rh) 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 Temperature ( ) 85 *When the chamber is operated below +30 to +40, continuous operation is restricted due to the dew condensation in the cooler (also functions as a dehumidifier). 98 Application of high stress of 5 / min. or more now possible This faster temperature (& humidity) chamber enables the application of high stress to the specimen at a steep temperature rate of change of 5 /min. or more based on IEC60068-3-5, IEC60068-3-6 (without specimens loaded), thanks to the larger refrigeration systems installed in this series. The chamber features operation within wide temperature ranges: 70 to +180 and 40 to +180. Four models with 1800L capacity Two models are available for each of the temperature ranges from 40 to +180 / 70 to +180, with a humidity model (from 20 to 98%rh) also available for each type. Thus, a chamber model can be selected from four models to suit the intended application at best. Easy to set specimens For cases in which specimens are set in the chamber using a hand-lift, an insertion hole has been provided at the bottom of the chamber, and the test area has also been lowered, so that large-sized specimens and heavy articles can easily be inserted or withdrawn. Test area (one set of shelves and shelf supports equipped as standard) Shelf Shelves structure (Japanese patent no.4418691) Due to the large size (1200mm wide 1500mm deep) of the test area, shelves are relatively heavy. With this in mind, shelves have been designed in a twopiece structure. Moreover, storage space is provided at the bottom of the device to hold the shelves. Free access of the chamber Since the machinery compartment is located in the back of the test area, virtually no maintenance space is required on either side of the equipment, enabling access either from the right or the left. 3

Characteristics Viewing Windows as Standard Equipped with viewing windows as standard, and chamber lamp (LED lamps) provide greater visibility. Door unlocking system inside the chamber A door unlocking handle is installed inside the chamber, so that the door can be opened from inside, should someone be locked in by mistake. Chamber lamp switch Viewing window Simple replacement of wick The wick located at the upper rear of the test area must be replaced periodically in order to maintain high precision of humidity measurement at all times. To this end, the wick has been designed for easy replacement from the exterior. Pocket for printed material A pocket is provided at the lower front of the chamber to store printed material such as the operation manual. Door unlocking system Wick installation (Test area) External view of wick (Right side) 4

Control operation N instrumentation P-310 Chamber lamp Color LCD Touch Panel A 7-inch wide color LCD fitted with LED backlight. Tabs are displayed at the bottom of the screen to help access to other screens. Multilingual support The language used by the instrumentation can be changed with the screen settings (Japanese / English). Touch navigation Touch icon to show navigation bar. Information notification The INFO icon will blink when chamber information requiring attention. Registering test patterns Program operation: 40 patterns (99 steps per program) Constant operation: 3 patterns Program Copy and Computer Editing Information Test data records Temperature & humidity settings and measurement values can be recorded on the internal memory and external memories. Copy test profiles Share the test profiles among chambers via USB memory* instead of PC. * USB memory not included. Copy Faster Temperature (& Humidity) Chamber Edit Faster Temperature (& Humidity) Chamber * Some items may not be copied between different models and chambers with different options. 5

Network * Requires an intranet Supported browser: Internet Explorer 11 Chambers can be operated from PC and tablet Remote monitoring and control (Ethernet connection) The chambers are equipped with unique web applications that enable chamber status to be confirmed and operated from a web browser screen (PC or tablet terminal). It is also possible to start operations with a PC or other device from a remote location. Editing test profiles with a browser It is possible to edit the test profiles registered in the chamber through a web browser. Login privileges Screen Chamber monitor Privileges Constant/ Program setup Run/Stop Image Configuration Displaying data in trend-graph Settings and measured data saved in the chamber can be displayed in graphs on a web browser. ( 別売 ) Administrator Operator User インターネット E-mail notifications Details on alarms that have been triggered will be sent to pre-registered e-mail addresses. It is also possible to transmit e-mails when testing has finished. * An Intranet environment is required to transmit e-mails. Email alert Faster Temperature (& Humidity) Chamber Ethernet イントラネット Intranet (company LAN) Mail server PC Mobile phone ESPEC OnlineCore Internet Test area A (Sold separately) Intranet Central control system recommended for multiple environmental test chambers installations Offices Test area B Test chambers of other manufacturers Measuring instrument Network camera *Please contact ESPEC for more information, about which products can be connected. 6

SPECIFICATIONS Model SML-21 SMU-21 SMS-21 SMG-21 System Performance *1 Construction Balanced Temperature (& Humidity) Control system (BT(H)C system) Temperature range 40 to +180 ( 40 to +356 ) 70 to +180 ( 94 to +356 ) Humidity range 20 to 98%rh 20 to 98%rh Temperature fluctuation ±0.5 ( 40 to +100 ) ±1.0 (+101 to +180 ) ±0.5 ( 70 to +100 ) ±1.0 (+101 to +180 ) Humidity fluctuation ±5%rh ±5%rh Temperature variation in space 3 Temperature rate of change 5 /min. no specimen (Average) 5 /min. no specimen (Average) Lowest attainable temperature 40 70 Exterior material Test area material Insulation Heater Humidifying boiler Cooler Air circulator Refrigerator unit 18-12-2.5 Cr-Ni-Mo stainless steal sheathed heater Cold-rolled rust-proofed treated steel plate 18-8 Cr-Ni stainless steel plate (2B polish) Glass wool Fin-type sheathed heater 18-12-2.5 Cr-Ni-Mo stainless steal sheathed heater Plate fin cooler (Also works as a dehumidifier) Sirocco fan (Direct-coupled electric motor type, 100 W 4) System Mechanical single stage refrigeration system Mechanical cascade refrigeration system Refrigerator Chamber total load resistance Inside dimensions (mm) *2 Outside dimensions (mm) *2 Capacity Scroll-type compressor, Water-cooled condenser, Cascade condenser (SMS, SMG only), Electronic expansion valve system, Refrigerant (R404A, R23 SMS, SMG only ) 100 kg W1200 H1000 D1500 (W47.2 H39.3 D59.0 inch) W1400 H1900 D2737 (W55.1 H74.8 D107.7 inch) 1800 L Weight 1250 kg 1400 kg Equipment Accessories Utility requirements Allowable conditions Power supply *3 Drain hose, Cable port 2 (φ50 mm, each side), Chamber lamp, Time signal terminal, Specimen power supply control terminal, Ethernet port (LAN), USB memory port, Viewing window (W295 H380 mm), Cable port rubber plug (Silicone sponge rubber, φ50mm), Shelf brackets, Shelf (front, back), Strainer, Strainer element, Nipple, Spacer for frame, Cartridge fuse, Wet-bulb wick, Operation Manual *Power cable is not included. Ambient temperature range: 0 to +40 (+32 to +104 ) Cooling water temperature range: +5 to +32 (+41 to +89.6 ) 200V AC 3φ 3W 50/60Hz 109 A 86 A 120 A 220V AC 3φ 3W 60Hz 97 A 75 A 109 A 380V AC 3φ 4W 50Hz 56 A 45 A 63 A 400V AC 3φ 4W 50Hz 57 A 45 A 64 A Cooling water supply pressure Cooling water supply rate Piping connection size Humidifying water supply Noise level *4 0.2 to 0.5MPa 2350 L/h (Reference temperature +25 ), 4400 L/h (Reference temperature +32 ) Electrical conductivity Electrical conductivity water quality 0.1 to 10μs/cm 0.1 to 10μs/cm Supply water pressure 0.07 to 0.5MPa 0.07 to 0.5MPa 32 A Max. 65dB *1 The performance values are based on IEC 60068-3-5:2001, and IEC 60068-3-6:2001. Performance figures are given for a +23 ambient temperature, a +25 refrigerator cooling water temperature, no specimens inside the test area and refrigerator capacity set to auto. *2 Excluding protrusions *3 Voltage fluctuation: ±10% of rated value. *4 Noise level was measured in an anechoic room at a height of 1.2 m from the floor and a distance of 1 m from the chamber front panel (ISO 1996-1:2003 A-weighted sound pressure level). 7

TEMPERATURE & HUMIDITY CONTROL RANGE 100 90 80 Relative 70 Humidity 60 (%rh) 50 40 30 20 10 0 MODEL SM - 21 10 20 30 40 50 60 70 80 85 90 100 Temperature ( ) *When the chamber is operated below +30 to +40, continuous operation is restricted due to the dew condensation in the cooler (also functions as a dehumidifier). Temperature & humidity range L : -40 / 20 to 98%rh U : -40 S : -70 / 20 to 98%rh G : -70 98 SAFETY DEVICES Leakage breaker for power supply (200 to 380V AC spec.) Circuit breaker for power supply (400V AC spec.) Circuit breaker for refrigerator Boil dry protector (SML, SMS only) SSR overload and short circuit protecting circuit breaker Temperature switch for air circulator Control circuit overload and short circuit protection fuse Electrical compartment door switch Refrigerator high /low pressure switch Thermal fuse Temperature switch for compressor Specimen power supply control terminal Reverse-prevention relay Upper and lower temperature (& humidity) limit alarms (built-in temperature (& humidity) controller) Burn-out circuit (built-in temperature (& humidity) controller) Watchdog timer (built-in temperature (& humidity) controller) Overheat protector (independent type) Water suspension relay Circuit breaker for heater Circuit breaker for humidifying heater (SML, SMS only) Switch for humidifying boiler water level detection (SML, SMS only) Wick insertion port switch (SML, SMS only) DIMENSIONS / FITTINGS LOCATION unit : mm 1400 50 1200 1500 2737 300 Wick replacement mechanism 200 USB memory port Viewing window 1225 1900 1200 1000 450 Cable port (each side) 450 100 800 50 Ethernet port Specimen power supply control terminal Time signal terminals Front side Right side 8

OPTIONS Power cable 5m 10m * AC 200V only * The chamber does not come with a power cable. Shelf, Shelf bracket Equivalent to standard accessory. Additional cable port Provided in addition/replacement of the standard cable port (left-side). *Equipped with rubber plug. φ25 mm φ50 mm φ100 mm Cable port rubber plug Comes with the cable port. Frost-free circuit Prevents frost from accumulating on the refrigeration circuit to allow longterm continuous operation. With models SMS and SMG, it is applicable with all chambers except those equipped with cascade refrigeration. Product temperature monitor When temperature measurement is performed on the specimen by the temperature sensor, the results are displayed on the instrumentation monitor screen. In programmed operation, the exposure time can be controlled, provided that the specimen temperature is within the available set temperature specifications. Measurement point: 1 Sensor in use: Thermocouple, Type T Appurtenances: Terminal board 1 Connecting position: Right side of the main unit (front) Accessories: Thermocouple, Type T 1 (φ0.32mm, 6m) Connector 1 Time signal terminals Nine relay contacts (time signals) added. (Two contacts standard equipped) Paperless recorder Records temperature of each section such as the temperature inside the chamber. Recorder location: Top or Left side Size: 144 144 mm *External dimensions change when attaching the recorder. (Please refer to the recorder location.) Display: 5.7inch color touch panel Data saving cycle: 5 sec. Internal recording media: Flash memory: 8MB External recording media: CF memory card (256MB) USB memory port Language support: ENG, JPN [Temperature type] Number of inputs (Initial setting): Temperature 1 (5 more channels can be turned ON) [Temperature and humidity type] Number of inputs (Initial setting): Temperature 1 / Humidity 1 (4 more channels can be turned ON) Interface RS-485 RS-232C GPIB Recorder location Top 144 144 unit:mm Left side 144 144 9

OPTIONS Recorder output terminal Temperature, humidity Output terminals for chamber tempera-ture and humidity. *Cannot be installed in conjunction with a recorder Dey-bulb temperature Terminal boards for dry-bulb sensor in the chamber. (SMU, SMG only) Thermocouple Attached to specimen to measure specimen temperature. *Thermocouple type T (Copper/ Copper-Nickel) 2m 4m 6m Anchoring fixtures Used to bolt the chamber to the floor. Overcool protector If the temperature inside the chamber decreases excessively, the chamber stops operating to prevent the specimens from being damaged. Additional overheat protector Additional preventive measures can be taken for excessive temperature rise in the chamber, in addition to the standard equipped overheat protector. External alarm terminal If the safety device of the chamber is activated, the external alarm terminal will notify it to a remote point. Emergency stop push button Stops the chamber immediately. Operation manual CD Booklet Reports & certificates Testing and inspection report Test data Temperature (& humidity) uniformity measurement Calibration report Calibration certificate Traceability certificate Traceability system chart With guard Safety precautions Do not use specimens which are explosive or inflammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. Do not place corrosive substances in the chamber. If corrosive substances are generated by the specimen, the life of the chamber may be significantly shortened specifically because of the corrosion of stainless steel and copper and because of the deterioration of resin and silicon. Do not place life forms or substances that exceed allowable heat generation. Be sure to read the operation manual before operation. 10

http://www.espec.co.jp/english Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-5500 ESPEC NORTH AMERICA, INC. Tel : 1-616-896-6100 Fax : 1-616-896-6150 ESPEC EUROPE GmbH Tel:49-89-1893-9630 Fax:49-89-1893-96379 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-51036677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-10-64627025 Fax : 86-10-64627036 TIANJIN Branch Tel : 86-22-26210366 Fax : 86-22-26282186 GUANGZHOU Branch Tel : 86-20-83317826 Fax : 86-20-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-68028890 Fax : 86-512-68028860 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-68798008 Fax : 86-21-68798088 ESPEC ENGINEERING (THAILAND) CO., LTD. Tel : 66-3-810-9353 Fax : 66-3-810-9356 Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2015 (JIS Q 9001:2015) through the Japanese Standards Association (JSA). *Registration : ESPEC CORP. (Overseas subsidiaries not included) Environmental Management System Assessed and Registered ESPEC CORP. (Overseas subsidiaries not included) Specifications are subject to change without notice due to design improvements. TF12E29C06 (The contents of this catalog is as of December, 2017.) Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.