SKYPAK II Heating & Cooling Self Contained Packages

Similar documents
SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Advance Release September 2009

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

technical guide Water-Cooled Self-Contained Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

13 GEP A L P - 1 A

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Commercial High-Efficiency Condensing Units

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

RGE 13 A T - 1 A

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Commercial High-Efficiency Condensing Units

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MERIT Series R-410A - Upflow / Horizontal

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MERIT Series R-410A - Upflow / Horizontal

Concealed Ducted Split Series R-407C MBH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

48TF GAS HEATING/ ELECTRIC COOLING UNITS

High Heat COP. High/Low Stage

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

PACKAGE AIR CONDITIONER

MERIT SERIES Up Flow / Horizontal

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Cooling/Heat Pump Convertible Air Handlers

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Water-Cooled Self-Contained Units

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PAJ3. Product Specifications

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

PAR5. Product Specifications

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

CWA4 Chilled & Hot Water Fan Coil

TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

48TM GAS HEATING/ELECTRIC COOLING UNITS

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

G6RC Series TECHNICAL SPECIFICATIONS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

8+* Bulletin No November 1997

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

VariCool VAV Engineering Guide

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

catalog CDV Fan-Coil Units High-Performance, Vertical

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Incremental Comfort Conditioners

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Product Specifications. Vertical Floor Consoles By First Co.

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

MAC N-407 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

VERTICAL FAN COIL UNITS

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

GUIDE SPECIFICATIONS AQUARIUS ii

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

36,000-62,000 BTUH Nominal Capacity

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Condensing Units & Air Handlers

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

TECHNICAL SPECIFICATIONS

Transcription:

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation in residential low and high rise, industrial and commercial applications. The all-indoor design eliminates the need for any unsightly exterior equipment, and refrigerant line connections, while maintaining architectural esthetics, protecting the Skypak from weathering and vandalism. SKYPAK II Features and Data Available in natural gas (direct vent), electric heating, or hot water heating. Gas input ratings of 0,000, 40,000, 60,000, and 80,000 BTUH. Cooling capacity from 1,000 to 9,000 BTUH. R-410A refrigerant. Every unit rigorously factory tested for quality control. Allows independent metering and temperature control, eliminating building wide service shut downs as encountered with conventional systems. Aluminized steel tubular heat exchanger provides 80.3% AFUE. Return air can be ducted if required. Power vented through wall sleeve, eliminating chimney. High efficiency scroll or rotary compressor (rotary in 1,000 BTUH models). Convenient indoor access to all parts and service needs, eliminating bulky chassis removal and spares. Condensate drain isolated from air stream. Left hand or right hand unit configuration. Exterior grilles available in five standard colours - or custom match (optional) All components readily available through authorized stocking distributors.

SKYPAK II GAS HEAT / ELECTRIC COOLING Model SGAD011 SGAD4011 SGAD40181 SGAD60181 Heating Section Rated Input-BTU / HR Output Capacity-BTU / HR CFM (Motor Speed) AFUE 0,000 16,160 350 (MED-LO) 40,000 3,30 55 (HI) 08-30 / 1 / 60 40,000 3,30 600 (MED) 60,000 48,480 675 (HI) Cooling Section BTU / HR T. C* BTU / HR Sensible CFM At.30" E.S.P. Efficiency (S.E.E.R.) Compressor R.L.A. Compressor L.R.A. Min. Circuit Ampacity Max. Fuse / CCT. BKR. Filter Size / Type ** Approx. Ship Weight (LBS.) 08-30 / 1 / 60 197 min. Oper. VOLTS 1,100 18,000 9,300 13,800 400 600 11.0 11.5 5.7 10.0 31.0 48.0 9.03 14.80 15 0 4" x 34" / 1" Thick Replaceable Media 95 335 Model SGAD4041 SGAD6041 SGAD60301 SGAD80301 Heating Section Rated Input-BTU / HR Output Capacity-BTU / HR CFM (Motor Speed) AFUE 40,000 3,30 600 (LO) 60,000 48,480 700 (MED) 08-30 / 1 / 60 60,000 48,480 750 (LO) 80,000 64,640 800 (MED) Cooling Section BTU / HR T. C* BTU / HR Sensible CFM At.30" E.S.P. Efficiency (S.E.E.R.) Compressor R.L.A. Compressor L.R.A. Min. Circuit Ampacity Max. Fuse / CCT. BKR. Filter Size / Type** Approx. Ship Weight (LBS.) 08-30 / 1 / 60 197 min. Oper. VOLTS 4,400 9,100 19,400 3,400 800 975 11.0 11.0 14.1 15.7 58.3 73.0 0.63 3.03 30 35 4" x 34" / 1" Thick Replaceable Media 345 365 Caution: Cooling section of this unit should not be operated when outside temperature is below 60 F Performance tested in accordance with ARI standard 10/40-03, and rating conditions of 95 F outdoor ambient, and 80 F D.B./67 F W.B. indoor air temperature. * T.C. = net cooling capacity (Heat dissipation from fan motor included). ** Factory Supplied. As Enviro-Tec maintains a continuous product improvement policy, specifications are subject to change without notice.

SGAD DIMENSIONAL DATA

SKYPAK II ELECTRIC HEAT / ELECTRIC COOLING Model SEAD511 SEAD0511 SEAD7511 SEAD05181 SEAD75181 SEAD10181 Heating Section KW Total 08 / 30 No. of Elements CFM (Motor Speed) Heating Output MBTU / HR.10 /.57 1 300 (LO) 7.1 / 8.7 4.0 / 5.14 1 400 (MED) 14.3 / 17.5 08-30 / 1 / 60 6.30 / 7.71 600 (HI) 1.5 / 6.3 4.0 / 5.14 1 500 (LO) 14.3 / 17.5 6.30 / 7.71 600 (MED) 1.5 / 6.3 8.41 / 10.8 700 (HI) 8.7 / 35.1 Cooling Section BTU / HR T. C* BTU / HR Sensible CFM At.30" E.S.P. Efficiency (S.E.E.R.) Compressor R.L.A. Compressor L.R.A. Min. Circuit Ampacity 08V Max. Fuse / CCT. BKR. 08V Min. Circuit Ampacity 30V Max. Fuse / CCT. BKR. 30V Filter Size / Type** Approx. Ship Weight (LBS.) 13.6 15 14.97 15 08-30 / 1 / 60 197 min. Oper. VOLTS 1,100 9,300 400 11.0 5.7 31.0 6.30 30 8.93 30 18,000 13,800 600 11.5 10.0 48.0 39.4 40 43.40 38.9 40 4.90 45 6.80 30 9.43 30 45 4" x 34" / 1" Thick Replaceable Media 70 305 5.10 60 57.37 60 Model SEAD7541 SEAD1041 SEAD1541 SEAD75301 SEAD10301 SEAD15301 Heating Section KW Total 08 / 30 No. of Elements CFM (Motor Speed) Heating Output MBTU / HR 6.30 / 7.71 700 (LO) 1.5 / 6.3 8.41 / 10.8 800 (MED) 8.7 / 35.1 08-30 / 1 / 60 1.61 / 15.4 3 800 (MED) 43.0 / 5.6 6.30 / 7.71 700 (LO) 1.5 / 6.3 8.41 / 10.8 800 (MED) 8.7 / 35.1 1.61 / 15.4 3 800 (MED) 43.0 / 5.6 Cooling Section BTU / HR T. C* BTU / HR Sensible CFM At.30" E.S.P. Efficiency (S.E.E.R.) Compressor R.L.A. Compressor L.R.A. Min. Circuit Ampacity 08V Max. Fuse / CCT. BKR. 08V Min. Circuit Ampacity 30V Max. Fuse / CCT. BKR. 30V Filter Size / Type** Approx. Ship Weight (LBS.) 39.80 40 43.78 45 08-30 / 1 / 60 197 min. Oper. VOLTS 4,400 19,400 800 11.0 14.1 58.3 5.48 60 57.74 60 9,100 3,400 975 11.0 15.7 73.0 5.48 60 57.74 77.78 80 85.68 90 39.80 40 43.78 45 60 4" x 34" / 1" Thick Replaceable Media 35 345 77.78 80 85.68 90 Caution: Cooling section of this unit should not be operated when outside temperature is below 60 F Performance tested in accordance with ARI standard 10/40-03, and rating conditions of 95 F outdoor ambient, and 80 F D.B./67 F W.B. indoor air temperature. * T.C. = net cooling capacity (Heat dissipation from fan motor included). ** Factory Supplied. As Enviro-Tec maintains a continuous product improvement policy, specifications are subject to change without notice.

SEAD DIMENSIONAL DATA

SKYPAK II HOT WATER / ELECTRIC COOLING MODEL NUMBER SWAD01 SWAD018 SWAD04 SWAD030 HEATING COIL AREA /ROWS / FPI.43 / / 14 FLOW RANGE (USGPM) 3-6 WATER CONNECTION SIZE 1/ in FPT COOLING SECTION 08-30 / 1 / 60 197 min. Oper. VOLTS BTUH T.C.* 1,100 18,000 4,400 9,100 BTUH SENSIBLE 9,300 13,800 19,400 3,400 CFM AT.30" E.S.P. 400 600 800 975 EFFICIENCY (S.E.E.R.) 11.0 11.5 11.0 11.0 COMPRESSOR TYPE ROTARY SCROLL SCROLL SCROLL COMPRESSOR R.L.A. 5.7 10.0 14.1 15.7 COMPRESSOR L.R.A. 31.0 48.0 58.3 73.0 MIN. CIRCUIT AMPACITY 9.03 14.80 0.63 3.03 MAX. FUSE/CCT. BKR 15 0 30 35 FILTER SIZE / TYPE** 4" x 34" / 1" Thick Replaceable Media APPROX. SHIP WEIGHT (LBS.) 95 335 345 365 Caution: Cooling section of this unit should not be operated when outside temperature is below 60 F Performance tested in accordance with ARI standard 10/40-03, and rating conditions of 95 F outdoor ambient, and 80 F D.B./67 F W.B. indoor air temperature. * T.C. = net cooling capacity (Heat dissipation from fan motor included). ** Factory Supplied. As Enviro-Tec maintains a continuous product improvement policy, specifications are subject to change without notice. HEATING COIL PERFORMANCE 65 ENTERING AIR TEMPERATURE

SWAD DIMENSIONAL DATA

TYPICAL INSTALLATION LAYOUT * ROUGH-IN OPENING DIMENSIONS

INSTALLATION ACCESSORIES

MECHANICAL SPECIFICATION GENERAL All SKYPAK models feature a complete heating, cooling, and air handling system in one self-contained assembly. Units are shipped completely factory assembled, tested, precharged, and ready for field connection. The unit casing is made entirely of heavy gauge galvanized steel. The cabinet interior is fully insulated with foil faced fiberglass insulation, firmly attached with nonflammable adhesive, to prevent heat loss or gain to the interior space. All operating components of the mechanical systems are completely enclosed in the insulated cabinet to minimize sound transmission. Units are designed for freestanding floor mounting, in conjunction with the companion wall sleeve. Airflow orientation is upflow, top discharge. Units may be ordered in either left hand, or right hand, return air configuration. The return air opening is field selectable for side intake or bottom intake; a pre-scored intake-opening panel requires removal from either the evaporator side panel, or the unit bottom panel. An optional bottom return air plenum is available to allow alternate return air duct layouts. The outdoor wall grille is available in five standard colors, or may be custom color matched. COOLING SECTION All models utilize high efficiency rotary or Scroll type compressors. Each refrigeration circuit is thoroughly evacuated, and fully charged with R-410A refrigerant before shipment. Internal compressor-motor overload protection is standard. Compressors are mounted on rubber isolators to minimize vibration transmission. A compressor start assist device is included to ensure reliable compressor operation in the event of low supply voltage. The refrigeration circuit includes an adjustable thermal expansion valve, liquid line filter drier, a high refrigerant pressure switch (manual reset), and service gauge ports. The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. The evaporator coil is employed in a blow-through configuration. Large evaporator coil face area maximizes efficiency and cooling performance. INDOOR AND OUTDOOR FANS Forward curved, double inlet and double width, direct-drive centrifugal blowers are used for evaporator and condenser air movement. Large diameter wheels are employed to provide required airflow performance at minimum sound levels. Blower wheels are fabricated of galvanized steel. Fan motors are PSC types, with minimum three speeds on the evaporator motor. The PSC motors feature permanently lubricated bearings and internal thermal overload protection. DIRECT VENT GAS FURNACE SECTION The gas-fired heat exchanger is a tubular aluminized steel design with no-weld construction. The burner section is of the in-shot design, with hot surface ignition. All air for combustion is drawn through the outside wall grille. Flue gases are power vented through the upper wall grille section. Furnace controls include a high limit switch, flame roll out sensor, ignition sensor, ventor motor safety switch, and an indoor blower control module. The unit controls are factory wired to a low voltage terminal strip, for connection to a single stage heat/cool thermostat. ELECTRIC FURNACE SECTION Electric heating elements consist of resistance type nickelchrome wire supported in ceramic holders. The bare wire elements are exposed directly in the air stream resulting in instant heat transfer, lower element temperatures, and long service life. Each heavy gauge element frame is equipped with an auto reset limit control, and elements are individually removable for service. Relays bring the heating elements on and off, in sequence and equal increments, with a time delay between each element. In addition, relays initiate or stop blower operation, or change blower speed. The unit controls are factory wired to a low voltage terminal strip, for connection to single stage heat/cool thermostat. HOT WATER HEAT SECTION The two-row hot water heating coil is constructed of copper tubes mechanically bonded to aluminum plate fins. The large coil face area ensures maximum heat transfer from the hot water supply. An optional circulating pump may be factory installed to provide control of the water flow, simultaneous with blower operation. The unit controls are factory wired to a low voltage terminal strip, for connection to a single stage heat/cool thermostat. FILTERS All models are shipped with an internal, suspended wireframe style filter rack, for use with replaceable filter media. A one-inch thick fiberglass media filter is factory provided. ACCESSORIES Wall Sleeve (Standard depths = 6, 8,10,1,14 inches) Exterior Grille (Five standard colors) Bottom Return-Air Plenum External Flat Panel Filter Rack Side Return Only (allows use of higher efficiency filters; field supplied) Low Ambient Cooling Kit (allows compressor operation to 45 F outdoor ambient) Outdoor Temperature Lockout Thermostat (prevents compressor operation below 60 F outdoor ambient) Hi-Altitude Furnace Kit (required above 000 feet elevation) (Canada Only) Propane Conversion Kit 10

COMPONENT LAYOUT 8 1 7 6 5 3 4 KEY COMPONENTS 1. Primary and secondary aluminized steel tubular heat exchanger.. Centrifugal evaporator and condenser blowers, zinc coated wheels and painted housing for rust resistance. 3. Available in left hand or right hand configuration. 4. High efficiency compressor. 5. Heavy gauge galvanized steel cabinet, fully insulated. 6. Honeywell smart valve c/w hot surface igniter. 7. Power ventor. 8. Thermal expansion valve. Left Hand Configuration Illustrated Optional Electric Heating.5-15 KW Enviro-Tec Model # Nomenclature Code Model# SGAD 60 4 1 L C Product Type SGAD = SKYPAK S SERIES - GAS HEAT SEAD = SKYPAK S SERIES - ELECTRIC HEAT SWAD = SKYPAK S SERIES - HOT WATER HEAT Nominal HeatingCapacity SGAD0 = 0MBH INPUT SGAD40 = 40MBH INPUT SGAD60 = 60MBH INPUT SGAD80 = 80MBH INPUT SEAD5 =.5 Kw SEAD05 = 5 Kw SEAD75 = 7.5 Kw SEAD10 = 10 Kw SEAD15 = 15 Kw Voltage 1 = 08-30/1/60 Nominal Cooling Capacity 1 = 1,000 BTUH 18 = 18,000 BTUH 4 = 4,000 BTUH 30 = 30,000 BTUH Convertible Return FIELD SELECTED BOTTOM OR SIDE Unit / Return Air Configuration L = LEFT HAND R = RIGHT HAND 11

City of New York Department of Buildings MEA Enviro-Tec maintains a continuous product improvement policy, therefore specifications are subject to change without notice. 04/08