APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Similar documents
Operations Manual. Part Number: For Research Use Only

ST5189/ST5189E Bioclave

Class B Autoclaves Instruction for Use

A WORLD OF QUALITY, SAFETY AND HYGIENE STERILCLAVE. 18 litres-bhd/b/s

OPERATION & MAINTENANCE MANUAL

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

OPERATION & MAINTENANCE MANUAL

PERFORM Operating Document

OPERATION & MAINTENANCE MANUAL

Steam sterilizer AHS-75-DRY

AZTECA A LITRE STERILISER

Available from. M3 ULTRAf AST. Phone (502) Toll-free (800) Online

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5.

BRAVO AUTOCLAVES. Installation Notes. BRAVO 1 Quick Start Guide SD-402 Rev. 1.0 Copyright 2012 SciCan Ltd. All rights reserved

MODEL 7000 SUCTION UNIT

M9 M /M3 11/ Automatic Sterilizers

AUTOCLAVE STEAM STERILIZERS (BENCH TOP)

Tornado Operations & Maintenance Manual

AUTOMATIC STERILIZERS

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

OPERATION & MAINTENANCE MANUAL

Operating Instructions

POLYMIX PX-IG 2000 Operating Instructions

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

INSTRUCTIONS CertoClav EL

Theory of Operation: M9/D & M11/D

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Manual Page 1 of 8. Manual. Laboratory autoclave

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

Glass and Dishwashers AMX / AUX Series

Table of Contents. English

Tabletop 2340 EA-D Class S Autoclave 19 Litres

EL400 OPERATION MANUAL

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

LS5 VACUUM & NON-VACUUM AUTOCLAVES. Instructions for use. ST-IM61e

EZ9Plus & EZ11Plus Instructions on: Operating

OPERATI ON & MAI NTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL

Operation and Maintenance Manual

PREMIUM LINE. DOMINA PLUS B Water Steam Sterilizer. User Manual. Rev. 8 Date: March 2017 OM1004U

SimpleVIS Viscometer Reference Guide P

OPERATING AND MAINTENANCE MANUAL

I N S T R U C T I O N S

CLINOCLAV steam sterilizer AH-21 L

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

RELIABLE. The Midmark M9 and M11 UltraClave Automatic Sterilizers - make sterilization reliable and efficient.

LabClave.Com OPERATION & MAINTENANCE MANUAL. Horizontal Autoclave Model: Z-LABCLAVE-01-1 S/N

OPERATION & MAINTENANCE MANUAL

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

1 L Rotary Vacuum Evaporator Instruction Manual

COMINOX. SAFETY. TECHNOLOGY. DESIGN.

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

M4.9. NO LONGER IN PRODUCTION Some service parts may not be available for this product- Service and Parts Manual M4.9-0

Dyna-Form Air. Alternating Pressure Relief Overlay System

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

Technical Specifications. Schedule 6(i) Electric operated Autoclave (2 Drum)

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Hand Dryer Installation & User Manual

Laboklav. Laboklav ECO Steam Sterilizer Basic / with Forced Cooling 80 Litres, 135 Litres. User Manual. Steam sterilizers

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

Water Distiller Service Manual

Operation and Maintenance Manual

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

SERVICE MANUAL. Kleenmaid SMART oven OMFHS6010

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

O P E R A T I N G I N S T R U C T I O N S

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

O P E R A T I N G I N S T R U C T I O N S

30DSERIES E32D4. (Digital Operation) Installation and Operation Manual

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Local Air Conditioner

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

Mobile Air Conditioner Instruction Manual Model TC-N9KM

SERVICE MANUAL. IPP Cooled incubator with Peltier technology HPP 108 Constant Climate Chamber with humidification

OPERATING INSTRUCTIONS KSG 40/60-2 KSG 50/70-2 KSG 50/80-2 KSG 50/95-2

Classic Media Operating Instructions

Corn Flame Energy Corn Stove Model 3000

SMD Rework Station TABLE OF CONTENTS

A few simple steps to ensure perfect water, every time.

CHH30 Dishwasher. Wiring Diagram. Spare Parts List. Installation / Operation

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

40cm Pedestal Fan with Remote Control

Bravo. Troubleshooting Guide

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

TECHNICIAN MANUAL. Table -Top Autoclaves models 1730, 2340, 2540, 3140, 3850, 3870 M & MK 1730MK Valueklave

Features. Control Panel. Exhaust Vent Power Cord. Ceramic Plate. Control Panel. Power Mode Indicator. Power / Temperature and Timer Display

A few simple steps to ensure perfect water, every time.

Service Instructions

air conditioner/dehumidifier 9000btu/hr

Operating Instructions

A measured step forward

Tornado Operations & Maintenance Manual

WC141 Integrated Dishwasher Installation, Use and Maintenance

Coffee Machine Zia series

Autoclaves. Steam Autoclaves

Transcription:

Thank you for choosing the Biomega BioClave steam sterilizer. Your steam sterilizer has been CE certified and designed with durability, reliability, and safety in mind. It is your responsibility to install this instrument in conformance with local electrical codes. APPENDIX 4 HYDRAULIC DRAWING Safety valve Pressure sensor This manual contains important operating and safety information. Please read and understand the contents of this manual prior to operating this instrument. Condenser Chamber Pump Distilled water tank Used water tank V1: Air release valve V4: Water release valve 24

APPENDIX 3 TABLE OF CONTENTS TANK MAX. LEVEL PUBLIC TANK MIN. LEVEL USED WATER TANK MAX. LEVEL DOOR SWITCH KEYBOARD DATA LINE PRINTER OUTPUT TP 1 TP 2 TP 3 ELECTRICAL DRAWING V1 110 220V T12A 20 T12A 20 V4 PRESSURE SENSOR 21V 9V Tp1: Steam generator temperature sensor TP2: Inner-Chamber temperature sensor TP3: Temperature sensor of chamber wall V1: Air release valve V4: Water release valve AC220V 110 OUTPUT FAN THERMAL PROTECTOR THERMAL PROTECTOR WATER PUMP STEAM HEATER CHAMBER HEATER 1. GENERAL ------------------------------------------------------------ 1 2. TECHNICAL SPECIFICATIONS----------------------------------- 2 3. PACKING CONTENT ----------------------------------------------- 3 4. INSTALLATION ---------------------------------------------------- 4 5. CONTROL PANEL --------------------------------------------------- 5 6. OPERATION --------------------------------------------------------- 6 6.1 POWER ON ------------------------------------------------------ 6 6.2 FILLING THE DISTILLED WATER ----------------------------- 6 6.3 PREPARING THE MATERIAL FOR STERILIZATION ----- 6 6.4 SELECTING THE STERILIZATION PROGRAM -------------- 7 6.5 RUNNING THE STERILIZATION PROGRAM ----------------- 7 7. DRAINING THE WATER TANKS ---------------------------------- 9 8. ADVANCED SETTING ---------------------------------------------10 9. PRINTER (OPTIONAL) --------------------------------------------11 10. MAINTENANCE -------------------------------------------------- 12 11. TRANSPORT AND STORAGE ----------------------------------- 12. ERROR CODES-----------------------------------------------------16 13. SERVICE AND CONTACT---------------------------------------- 17 APPENDIX 1. WATER PROPERTIES / CHARACTERISTICS -------------- 18 2. DIAGRAMS OF THE STERILIZATION PROGRAMS ----- 19 3. ELECTRICAL DRAWING ----------------------------------------- 23 4. HYDRAULIC DRAWING ----------------------------------------- 24 23

1. General The sterilizer described in this manual is intended for the sterilization of research tools. It operates automatically with 134 C and 121 C sterilization temperatures. This sterilizer is in compliance with the European Directive 93/42/CEE and it has been produced in accordance with the EN 160. In addition the chamber has been ASME certified. Pressure psi LIQUID 134 C 1 2 10 11 0 Time (min) 3 12 4 13 9 8 7 6 5 1 Distilled (clean) water tank 2 Display 3 Control panel 4 Power switch 5 Fuses 6 Drain connector, clean water tank 7 Door handle 14 8 Door 9 Drain connector, used water tank 10 Safety valve 11 Condenser ventilation 12 Serial / Electrical Label 13 Printer port (printer is optional) 14 Power supply cord Pressure psi LIQUID 121 C For safe operation, please pay close attention to the alert symbols below which cab be found throughout this manual. Please carefully read and understand the contents of this manual prior to operating this instrument. 0 Time (min) This symbol represents an electrical caution - ground protection HOT SURFACE. This symbol represents a hot surface This symbol is used to draw the attention of the reader to particularly important notions for operator safety. 1 1 22

2. Technical Specifications Pressure psi WRAPPED 134 C (1)Chamber Dimensions: 9in. x 14.2in. / 2mm x 360mm (2)Rated Voltage: AC110V-120V or 220-240V, 50-60Hz (3)Nominal power: 1600W (120V) 1250W(220V) (4)Sterilization Temperature: 121 C / 134 C (5)Main Fuses: T20A/250V (6) Capacity of the distilled water tank: Approx 2.5L (water at level MAX) 0 Time (min) (7)OperatingEnvironment: 5-40 C (8)External Dimensions: 17.5in. (width) x 16.7in. (height) x 23in. (depth) 445mm (width) x 400mm (height) x 590mm (depth) (9)Net weight: 99lbs. /45kg (10)Noise: <60dB (11)Relative Humidity: max 80%, non condensing Pressure psi WRAPPED 121 C (12)Atmospheric Pressure: 76kPa -106kPa 0 Time (min) 21 2

3. Packing Content No Accessory Quantity 1 16L Steam sterilizer 1 Pressure psi UNWRAPPED 134 C 2 Loading tray 3 3 4 5 6 Tray rack Tray handling tool Door adjustment tool Draining hose 1 1 1 2 0 Time (min) 7 1 8 Spare fuse power (20A) 2 9 Spare fuse for valve (3A) 2 10 Spare fuse for mainboard (1A) 2 11 Door seal 1 Pressure psi UNWRAPPED 121 C 0 Time (min) 3 20

APPENDIX 2 4. Installation DIAGRAMS OF THE STERILIZATION PROGRAMMES PROGRAM UNWRAPPED WRAPPED Temperature ( C) 134 121 134 121 Pressure (PSI) 16 16 Holding time (min.) 4 6 Total time (min.) 12~ ~45 ~40 35~50 TYPE Unwrapped solid material Unwrapped hollow material Single-wrapped solid material MAXLOAD (kg) 5.00 5.00 5.00 4.00 * * * * * Ensure that the sterilizer is installed with 2.5in. (10cm) ventilation space on all sides of the sterilizer, and 5 in. (20cm) on top side. The clearance required to open the door is.5in. (40cm). The sterilizer should be placed on a level worktable. Do not cover or block the door, ventilation or radiation openings on the sterilizer. Do not install the sterilizer near a sink or in a location where it is likely to be splashed. Do not install the sterilizer nearby a heat source. LIQUID 134 12 ~65 Wrapped liquid 0.50 121 16 45~65 Wrapped liquid 0.50 DRY ONLY <100 0 The max. temperature of the 134 C sterilization cycle is 136C The max. temperature of the 121 C sterilization cycle is 123C Above dimensions are shown in mm. 19 4

APPENDIX 1 Water Properties/Characteristics: DESCRIPTION WATER CONDENSATE Evaporate residue Silicium oxide sio 2 Iron Cadmium Lead Rest of heavy metals, excluding iron, cadmium, lead Chloride Phosphates Conductivity (at 20 ) ph value Appearance Hardness 10 mg/l 1 mg/l 0.2 mg/l 0.005 mg/l 0.05 mg/l 0.1 mg/l 2 mg/l 1.0 mg/kg 0.1 mg/kg 0.1 mg/kg 0.05 mg/kg 0.1 mg/kg 0.1 mg/kg 0.1 mg/l 0.5 mg/l 0.1 mg/l ヲs/cm 5-7.5 Colorless, clean, without sediments 0.02 mmol/l 3ヲs/cm 5-7 Colorless, clean, without sediments 0.02 mmol/l 5. Control panel 5.1 Pressure display window. Displays the current pressure (PSI) inside the chamber 5.2 Temperature display window. Display the current temperature ( C) inside the chamber 5.3 Timer display window Displays the cycle state (see below) or the remaining cycle time 5.4 TEMP button Select the desired sterilization temperature according to your instrument. 5.5 Sterilization Cycles - UNWRAPPED - WRAPPED - LIQUID - DRY ONLY (Please see Appendix 2) 5.6 WATER indication lamp This lamp will illuminate when the distilled water tank. is low on water. The tank should then be filled (with distilled water). 5.7 FULL indication lamp This lamp will illuminate when the used water tank is full. The used water tank must be drained to continue operation. 5.8 START & STOP button Once the parameters have been chosen, press this button to start the sterilization cycle. To cancel or stop the cycle, press and hold this button for 3 sec. Cycle State Time Display State State description Ld preheating / loading The machine is prepared for sample loading Do Door state Door is open Po vacuuming The machine is vacuuming during a cycle HE Time in Min. PL Ed E1 - E9 heating sterilization/drying exhaust end Error state The machine is in heating mode Time remaining in program The machine is cooling and releasing steam. The cycle is completed, you can open the door and take out the sterilized sample. Error - Please see section 12 18 5

6. Operation 6.1 Power on 6.1.1 Open the chamber door and remove all inner packing and accessories. 6.1.2 Plug the power cord into the proper electrical outlet. (Please check that the power source is in accordance to the electrical specifications of the machine (listed on the power label). 6.1.3 Power on - The switch is located underneath the control panel on the front side of the machine. Following power up, the control panel illuminates. The Time window will display Ld. 6.2 Filling the water tank Open the top lid, and fill the tank with distilled water. The water should be filled within approximately 1 inch of the black seal. If you hear a beep signal, the max water level is exceeded. Please stop filling immediately. 13. Service and Contact For additional information on any of the error codes listed in section 10, please contact your sales representative, or contact Biomega Research Products Service Department at 1-908-769-5555. Please have the unit s serial number (located on the back panel of the instrument) available when calling. Do not send in a unit for service without first calling to obtain a repair authorization number and a decontamination form. The unit should be properly packed to avoid damage. Any damage resulting from improper packing shall be the responsibility of the user. 6.3 Sample Preperation For the most effective sterilization and to preserve the sample, please follow below: * Arrange the samples of different material on different trays or with at least 2in. of space between them. * Always insert a sterilization paper or cloth between the tray and sample, to avoid direct contact between the different materials. 6 17

* Verify all samples are not sealed, capped or closed. * Don't overload the trays above the stated limit (see Appendix 1). * Don't stack the trays one above the other or put them in direct contact with the walls of the sterilization chamber. * When handling the trays, always use the tray removal tool. * Wrap each sample separately, if samples are wrapped together verify that they are of the same material. * Seal the wrap with sterilization adhesive ribbon or by a thermal sealer. * Never seal with metallic clips, pins, etc. as this jeopardizes the maintenance of the sterility; * When using sterilization paper, set the plastic part downward (tray side) and the paper side facing upward. 12. Error Codes Code E1 E2 E3 E4 E5 Description Steam generator temperature sensor error Inner temperature sensor error Temperature sensor of chamber wall error Failure to raise temperature Failure to release steam Proposed solution Check steam generator temperature sensor Check inner temperature sensor Check temperature sensor of chamber wall Check the water pump or the door seal Check the air release valve Always wrap samples. E6 E7 Door has opened during the cycle Time Error Make sure you have turned the door handle to the max. position or check the door switch Check the water pump and the air release valve 6.4 Select the sterilization program Select the appropriate sterilization temperature and cycle. (For additional information, see appendix 2.) E8 E9 EE Steam generator overheat Failure to hold temperature Program manually interrupted Check steam generator temperature sensor Ensure that the clean water tank is not empty or contact your dealer to check the heating system and temperature sensors. Shut off the power and restart the machine EF Failure to initialize Shut off the power and restart the machine 6.5 Running the sterilization program After selecting the appropriate sterilization settings, load the samples onto the loading tray and insert the tray into the autoclave using the tray handling tool. 7 16

10.6 Replace fuse 1). Switch off the power. 6.6 After the samples are loaded, close and lock the door by turning the door handle clockwise until it stops. 2). Push inward with a flat head screw driver, then unscrew the fuse holder (counter clockwise). 3). Pull out the fuse holder by hand. Caution: You must turn the door handle to the maximum position, otherwise the machine will alarm and an error message will be displayed during the cycle. 4).Replace the fuse with a fuse of the proper electrical requirements (see pg.2).. 5). Place the fuse holder back in place and use a flat head screw driver to fully push it in. Then tighten (clockwise). 6.7 Starting the sterilization program. Press the START button, the machine will begin the sterilization cycle and complete all phases (fill, sterilize, exhaust and dry) automatically. The cycle will complete in 12-65 minutes. (See Appendix 2) 11. Transport and Storage 11.1 Switch off the sterilizer before transportation or storage. Pull out the plug and let the machine cool down. 11.2 Drain both the clean and the used water tank. 11.3 Conditions for transportation and storage: Temperature: -20 C /~ +55C Relative humidity: 85% Atmospheric pressure: 50kPa~106kPa Caution: When you press the "Start" button and the door handle has not been turned to the maximum position, do will flash on the Time display window. The cycle will not begin until the door has been completely closed and the "Start" button is pressed again. 6.8 Sterilization cycle completion After a cycle is completed the time display will show Ed Once the pressure has reached 0 PSI on the display the door can be opened and samples can be removed. Always use the tray removal tool to load or unload the tray in order to avoid touching the hot surface of the trays. 8

7. Draining the water tanks 10.5 Replacement of the door seal 10.5.1 Fully open the door. 1.Connect the supplied drain hose to the drain valve by pressing it on firmly. 2.Set the drain valve to the open position by turning it counter clockwise 10.5.2 Remove the door seal carefully by pulling it by hand away from the door 10.5.3 Clean the new door seal carefully with a soft cloth saturated with distilled water. 10.5.4 Moisten the new seal with medical disinfectant. 10.5.5 Insert the new seal following the instruction below: 3.Pull the drain valve outward, the tank will begin to drain through the hose. 4.After you have completed draining the water, push the drain valve inward and set to the closed position The sterilizer includes two draining valves. The left valve is used for draining the used water tank. The right valve is used for draining the clean water tank. Always be sure that the hose is draining into a vessel with at least 2L capacity. 1). Press on the top of the seal. 2). Press on the bottom of the seal. 3). Press on the left and right portions of the seal. 4). Press the remaining seal surface and ensure that it is smooth. Caution: Always ensure the chamber and the door have been cooled down before attempting to change the seal. 9 14

10.3 Cleaning the inner-chamber, weekly - Remove the trays and tray rack from the inner-chamber - Wipe the inner chamber with a soft cloth saturated in distilled water - Apply the same procedure to the trays and tray rack. 10.4 Door adjustment Below are the instructions for the door adjustment. This should only be performed if the door is not providing the proper seal or if the door seal has just been replaced. 10.4.1 Open the door and insert the door adjustment tool in the gap beneath the plastic cover (Fig. 2). 10.4.2 To tighten the door seal, use this tool to adjust the door adjustment nut counter clockwise (Fig. 1). 10.4.3 If the door seal is too tight (it is difficult to lock/unlock the door), you may also adjust the door adjustment nut clockwise to loosen it. 8 Advanced adjustment settings 8.1 Adjustment of sterilization time and drying time 8.1.1 Hold the UNWRAPPED button for seconds. The machine will beep to signify that you have enetered the advanced settings mode. 8.1.2 The pressure display window shows 0, and the temperature display window shows - - -. The timer display windowwill show the preprogrammes sterilization time parameter. 8.1.3 Select the sterilization program that you wish to adjust. For example, If you want to adjust the parameter of WRAPPED. Press the WRAPPED button. Press the button again,the time display shows 1. 0 means the 121 sterilization time.(the range from 3 to 40 min.) 1 means the 134 sterilization time.(the range from 3 to 40 min.) 2 means the drying time.(the range from 3 to 20 min.) 8.1.4 Press TEMP button, the value of time parameter will plus one. 8.1.5 After finishing the adjustment, press START button to confirm it. 8.1.6 When adjusting the DRYING program, there is only one option, 2. This is to adjust the drying time. Caution: Always ensure that the sample being sterilized can withstand the sterilization time that is being programmed. Fig. 1 Fig. 2 Caution: Never attempt to adjust the door seal when the door is in the closed position. 13 10

9. Printer (Optional) 9.1 If you have purchase the BioClave printer device, you can connect the printer cable to the back of the sterilizer. 9.2 Connect the printer power cord to the socket with the proper electrical specifications. 9.3 Power on the sterilizer and press the sel button. 9.4 After the sterilization cycle has completed, the printer will begin printing the details of the sterilization cycle (see below). 10 Maintenance 7. Maintenance Frequency Daily Weekly Annually Operation Clean the door seal Wipe dry the inner chamber Clean the clean water reservoir Clean the inner-chamber Replace the door seal Example of the print report Program: wrapped Temperature: 134 Pressure: 39 PSI Vacuum Num.: 3 Dry Time: min Ster Time: 12min Cycle No: 00009 MAX. Temp: 135.1 MIN. Temp: 134.1 AVG. Temp: 134.6 MAX. Pres.: 41PSI MIN. Pres.: 38PSI AVG. Pres.: 39 PSI Start Time: 22:38 End Time: 23:17 Date: 2008-07-19 8.1 Cleaning the door seal Clean the door seal daily with a softy cloth saturated in distilled water 8.2 Cleaning the clean water tank Clean the clean water tank every week with medical disinfectant. 11 12