G-3/GS-3. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-3-*21N** COUNTERTOP COOLER. * 0,N,2,B,P,Z,W **G,I,M,7 plug types

Similar documents
GS-1. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-1 GS-1-013EB GS-1-N13EB COUNTERTOP COOLER

GS-2. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-2 GS-2-013EB GS-2-N13EB GS-2-P23EB GS-2-Z23EB COUNTERTOP COOLER

GS-2.5. Instruction Manual. G-Series Cooler. Manual is for the following models: COUNTERTOP COOLER

GS-2. Instruction Manual. G-Series Cooler

G-6c/GCG-6c. Instruction Manual. G-Series Cooler. Manual is for the following models: G-6-C23EB GCG-6-C23EB, G-6-CB23EB, GCG-6-CB23EB BEVERAGE COOLER

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

G-10f/GCG-10f UPRIGHT COOLER

GCG-26c. Instruction Manual. G-Series Cooler

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

INSTRUCTION MANUAL Water Dispenser

INSTRUCTION MANUAL FOR WINE COOLER

Vinobox C 50 1T Vinobox C 50 2T

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

177 Can Beverage Cooler

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

USER MANUAL. Vino 160 Vino 440. Wine Coolers

96 Can Beverage Cooler

WINE COOLER. Model: WR 64-16

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

Since User Manual LBC6178 Beverage Centre LWC646 Wine Storage Built Under. lemairappliances.com.au

AB-WINE18S Thermoelectric Wine Cooler OWNER S MANUAL Read and save these instructions.

INSTRUCTION MANUAL FOR WINE COOLER

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

INSTRUCTION MANUAL COMPRESSOR DRIVEN WINE COOLER

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

29 Bottle Compressor Wine Cooler

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

TWLRZ-238 REFRIGERATOR

HT-MOSEL-51D PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE WINE CHILLER

Thank you for buying this refrigerator-freezer. To ensure that you get the best

200L Chest Freezer / GVATCS20Q. Instruction Manual

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

9.9 CU.FT. TOP MOUNT REFRIGERATOR INSTRUCTION MANUAL. Model No.: HVDR1040W HVDR1040B HVDR1040S

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

AWR-290DB-B 29 Bottle Black Stainless Steel Compressor Wine Cooler

Model Modèle Modell Modello Modelo Malli:

Outdoor Refrigerator USER S MANUAL

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Countertop Refrigerator

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

Dual Zone Wine Cellar

INSTRUCTION & USER MANUAL

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

Bar Fridge USER MANUAL MB46W

Instruction Manual. 4.6 Cu. Ft. Refrigerator/Freezer. Wards.com Wards.com The solution for your cold-storage needs!

BAR FRIDGE MODEL:FF.69L

IMPORTANT INSTRUCTIONS READ & SAVE

INSTRUCTION MANUAL Thermoelectric Wine Cooler MODEL: AW-210ED

Ice Maker. Model BIM25. Instruction Manual. Write Serial Number of unit here:

Ui REFRIGERATOR SPEC SHEET

Wine Cellar. Instruction Booklet. Model: WC-2038

FR120RC/FR120RM FR120RR/FR120RB FN-153/FN-153C

WARNING/SAFETY PRECAUTIONS

FR-1020ARW FR-1020ARS

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

Instruction manual for slot-in wine cabinet

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

A PROUD HERITAGE OF EXPERIENCE & QUALITY. SINGLE- Zone Wine COOLER EL-33WCST

Freestanding Wine Cooler Instruction Manual

Outdoor/Commercial Refrigerator USER S MANUAL

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

WINE COOLER BUIT-IN DUAL-ZONE BE A PRO IN YOUR KITCHEN. K430D Bottles INSTALLATION GUIDE AND USER MANUAL. APPLICABLE MODEL: KD430D

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

OUTDOOR ICE MAKER Model BIM24OS

Beverage Air IMPORTANT

USER MANUAL KBU-21, KBU-52, KBU-68 SERIES COMPRESSOR BEVERAGE COOLER

ICE CREAM DISPLAY MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION

Wine Cabinet Manual. We know you don t want to read through this manual, but trust us, there is good information in here.

INSTRUCTION & USER MANUAL

2.4 Cu. Ft. Compact Refrigerator

WCD-200W Water Dispenser

Modular Island Grill - Refrigerator Module

USER MANUAL KBU-21, KBU-52, KBU-68 SERIES

AIR CONDITIONER ELECTRONIC CONTROL

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

TABLE OF CONTENTS. Safety Information...3. Installation Instructions...4. Reverse Refrigerator Door...5. Care and Maintenance... 9

GLASS DOOR BAR FRIDGE

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

Free Standing Water Cooler

Transcription:

G-Series Cooler G-3/GS-3 COUNTERTOP COOLER anual is for the following model: GS-3-*21N** * 0,N,2,B,P,Z,W **G,,,7 plug types nstruction anual

anual is for the following models: GS-3-*21N** * 0,N,2,B,P,Z,W **G,,,7 plug types nstruction anual G-3/GS-3

G-3/GS-3 FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting the best use of your cooler. Remember to record the model number and the serial number. This information can be found on the inside of your cooler. Keep your receipt with this manual for future warranty service. odel #: Serial #: Date of Purchase: TABLE OF CONTENTS Parts and dentification... 2 Safety nstructions... 3 nstallation... 3 Electric Connection... 3 Start... 3 aintenance... 4 Cleaning... 4 Condenser aintenance... 4 Light Replacement... 4 Power Failure... 4 oving the cooler... 4 Drip Pan... 4 Troubleshooting... 5 Refrigerant... 5 Specifications... 5 Switch Function... 6 Flammable R600a Warnings... 6 Circuit Diagram... 7 1 nnovative DisplayWorks

nstruction anual PARTS & DENTFCATON 1. Foam Cabinet 2. Evaporator 3. Return pipe 4. Evaporator Fan 5. Evaporator Safeguard 6. Evaporator Fan Safeguard 7. Evaporator Fan Cover 8. Rear Grill 9. Door Gasket 10. Glass Door 11. Top Hinge 12. Hinge Cover 13. LED Lights (4) 14. Bottom Hinge 15. Bottom Hinge Washer 16. Lock 17. Key (2) 18. Large Shelf (2) 19. Pilasters (4) 20. Shelf Clips (8) 21. Lockpin 22. agentic Switch 23. Consender Clip (4) 24. Thermostat 25. Transformer 1A 26. Transformer Box 27. Leveling Leg (4) 28. Compressor Base 29. Compressor 30. Drip Pan 31. Thermostat Box 32. Thermostat Box Cover 33. Thermostat Label 34. Switch (2) 35. Filter Drier 36. Condenser Fan 37. Condenser Fan Cover 38. Condenser Fan Cover 39. Power Cord 40. Condenser 2

G-3/GS-3 SAFETY NSTRUCTONS BEFORE USNG, PLEASE READ ALL NSTRUCTONS To reduce the risk of fire, electric shocks, or injury when using your cooler, please note the following basic precautions: Never clean appliance parts with flammable fluids. Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can cause a fire or explosion. As with all electrical appliances, please consult a licensed repair technician for any repairs. Do not block the ventilation holes located on the top of the cabinet. NSTALLATON Keep cooler in an upright position for 1-hour prior to use. This is essential for proper operation. f the cooler is transported in the horizontal position, the cooler must be returned to the upright position and not plugged in for 1 hour. Remove all the packing material before using your cooler. Clean the interior surface with a soft cloth and lukewarm water. f the cooler is transported in the horizontal position, check the drain pan and ensure that it is properly positioned above the compressor. For proper operation, place the cooler on a dry, level surface. Place the cooler at least 4 away from any walls. Otherwise, this could cause damage to the electrical cord and block the air circulation to the appliance. Do not block the air intake that ventilates the condenser unit. ELECTRC CONNECTON This model operates with an 115V/60Hz 220v-240V, power 50Hz power supply. supply. Check Check the electrical the electrical outlet outlet for proper for proper voltage. voltage. Warning: Plug unit directly into wall outlet. Do not use an extension cord or any other multiple connectors. For your safety, plug the unit into a grounded wall outlet. START Plug the cooler into the electrical outlet. For optimum performance, run cooler for 3 hours prior to use. Temperature Control: Do not adjust the temperature control. The temperature control is factory set to provide maximum performance. f really necessary, you can turn the thermostat by screw driver clockwise to have lower temperature inside the cooler LGHT CONTROL The inside light is controlled by the magnetic switch. 3 nnovative DisplayWorks

nstruction anual ANTENANCE Cleaning Before cleaning the appliance, always remember to unplug it. Unplug the cooler at the electrical outlet; never pull the service cord. Do not use sharp or pointed objects for cleaning. Clean the inside cabinet of the cooler with a clean damp cloth. Avoid damage by using non-abrasive and nonflammable cleaning products. Clean the condenser at least once a month with a vacuum cleaner or a brush to eliminate the dust accumulation. Light Replacement Unplug the cooler before removing the LED light strip. Remove the screws. Remove the light cover gently. Take out the LED light strip. Replace the used strip with new equivalent light strip. nstall the light cover and tighten the screws. Plug in the cooler. Power Failure Please minimize the frequency of opening the door during a power failure. f your cooler is unused for an extended period of time, unplug, empty, and clean your cooler and keep the door open to avoid condensation, formation of mold, or odors. oving The Cooler Empty the unit. Secure all loose parts inside the cooler. Tape the door shut. During transportation, make sure that the cooler is in an upright position. Drip pan During normal compressor cycle, water will drain into the drain pan and evaporate. To clean, gently pull the drain pan towards you and remove. Slowly reinstall it after cleaning. 4

G-3/GS-3 TROUBLESHOOTNG f your cooler is not working properly: Check the electrical outlet for power, and that the plug is properly inserted. Check to see if the circuit breaker is tripped or the fuse is blown. Check the condenser for proper cleaning. f your cooler is making noise: Check that the cooler is level and on a flat surface. f the compressor turns on and off frequently: The room temperature is higher than normal. The door is not closed completely. The door gasket is not sealed well. There is insufficient clearance around the cooler. The temperature is not set properly. The cycling frequency will reduce when all of the cans reach the set temperature. The following is not a malfunction: t is normal to hear gurgling sounds caused by the flow of refrigerant during each cooling cycle. REFRGERANT The G-3/GS-3 cooler utilizes R600a refrigerant. SPECFCATONS odel: Power Supply (V/Hz): Dimension (W x D x H): Box Dimension (W x D x H): aximum Load Per Shelf: NSF-7 Standard: G-3/GS-3 Countertop Cooler 220v-240V, 50Hz 18.5 x 21 x 35.25 20.25 x 22.25 x 36.5 34 lbs This equipment is intended for the storage and display of non-potentially hazardous bottled or canned products only. 5 nnovative DisplayWorks

nstruction anual SWTCH FUNCTON For models GS-3-N23EB, GS-3-023EB, GS-3-A23EB, GS-3-223EB Switch Status nterior LED Switch Door LED Remark / ON ON nterior ON and Door logo ON / O ON OFF nterior ON and Door logo OFF O / OFF ON nterior OFF and Door logo ON, interior LED turns ON when door opens O / O OFF OFF nterior OFF and Door logo OFF, interior LED turns ON when door opens Special Note: The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Children being supervised not to play with the appliance. 1. During user repair) Details concerning precautions during user maintenance (instructions shall include information pertaining to the handling, servicing and disposal). 2. Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance. 3. WARNNG Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in. 4. WARNNG Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. 5. WARNNG Do not damage the refrigerant circuit. 6. WARNNG Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer. 7. These appliances use flammable insulation blowing gas, please dispose the appliances according to the local regulation 8. Climate Class: 4 ( temperature 30%, Humidity 55%). 9. f the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 10. Caution: Risk of fire / flammable materials. 11. 6

G-3/GS-3 CRCUT DAGRA For models GS-3-021N7 t SAT T1 T2 XP L N 1 S o L 2 E CO L1 L2 T3 G XP-Plug CO-Compressor G-Startup L 1 L 2 - LED Lamp SAT-Temperature control T 1-nner fan Adaptor L-agnetism switch T 2-LED Lamp Adaptor S-nner LED Switch T 3-otor fan Adaptor 1 - nner fan 2 - otor fan E-Outstanding safeguard CRCUT DAGRA For models GS-3-N21N7 t SAT T1 T2 XP L N 1 S 2 o L S 1 2 E CO L1 L2 L 3 T3 G XP-Plug CO-Compressor G-Startup E-Outstanding safeguard L 1 L 2 L 3 -LED Lamp SAT - Temperature control T 1 - nner fan Adaptor L - agnetism switch T 2 - LED Lamp Adaptor S1 - Door LED Switch T 3- otor fan Adaptor S 2 - nner LED Switch 1 - nner fan 2 - otor fan CRCUT DAGRA For models GS-3-221N7 XP L N T1 1 T2 S 2 o L S 1 2 t SAT E CO L1 L2 L 3 T3 G XP-Plug CO-Compressor G-Startup E-Outstanding safeguard L 1 L 2 L 3 -LED Lamp SAT -Temperature control T1 - nner fan Adaptor L - agnetism switch T2 - LED Lamp Adaptor S1 - Door LED Switch T3 - otor fan Adaptor S2 - nner LED Switch 1 - nner fan 2 - otor fan 7 nnovative DisplayWorks

nnovative DisplayWorks, nc. To locate the distributor in your area go to: http://www.idw.global/contact/#distributors