Memorandum CITY OF DALLAS

Similar documents
Emergency Management. questions. need

Memorandum CITY OF DALLAS

Memorandum CITY OF DALLAS

Memorandum CITY OF DALLAS DATE: August 8, 2014 To: Honorable Members of the Public Safety Committee: Sheffie Kadane (Chair), Adam Medrano (Vice Chair)

Honorable Members of the Public Safety and Criminal Justice Committee Fire Watch Procedures

WOOSTER SAFETY CENTER

Memorandum CITY OF DALLAS. Riverfront Boulevard Design From Continental Avenue to Cadiz Street

SAN JOSE FIRE FIGHTERS

Q:%4~ Memorandum CITY OF DALLAS

Memorandum CITY OF DALLAS

Honorable Members of the Mobility Solutions, Infrastructure and Sustainability Committee

New High School Concept

FIRE STATION BUILDING COMMITTEE

Community Response Buchanan Elementary. December 13, 2016

PLAN REVIEW SUBMITTAL GUIDE

Master Facility Planning Update School Board Meeting May 26, 2016

REQUEST FOR COUNCIL ACTION 6A AGENDA ITEM ORIGINATING DEPT. AGENDA ITEM CITY ADMINISTRATOR APPROVAL

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED

Master Project List Report

Community Development and Recreation Committee

EXISTING FACILITY ASSESSMENT City of Summit Fire Headquarters

Nanuet Fire District Proposed Firehouse Project. Presented to the Nanuet Civic Association March 3, 2011

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Report To: Fire Commissioners From: Chief Sitar CC: Fire Station Committee Date: September 29, 2014 Re: Fire Station Needs

History of the Bowen Island Fire Hall Project

BURTON STATION STRATEGIC GROWTH AREA PLAN UPDATE JANUARY 25, 2018 PUBLIC MEETING

Clarendon Park Framework Plan. Chicago Park District Department of Planning & Development June 7, 2008

Waukee. City of. The Key to Good Living

MEASURE A. Completed Bond Projects

5.8 PUBLIC SERVICES FIRE PROTECTION AND EMERGENCY SERVICES

Facility Improvements


Fire Chief: Jeff L. Hogan

Mission. Vision. To set the standard for excellence and innovation in public safety. Department Description

C)49~ Memorandum CITY OF DALLAS

Public Services Department

DEPARTMENT OF PUBLIC SAFETY INTEROFFICE MEMORANDUM

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

Figure Example of out door dining in the public right-of-way.

POSITIONING BROKEN ARROW FOR THE FUTURE Your City, Your Vision TOWN HALL FORUM August 11, 2015

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

Massachusetts School Building Authority

REPORT CARD TO THE COMMUNITY MAY 15, 2018

ALABAMA. Downloaded

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

Honorable Members of the Mobility Solutions, Infrastructure and Sustainability Committee

VDOT Tunnel Facilities Action Plan

Baker County Volunteer Fire Department Fire Protection Assessment Update

This Review Is Divided Into Two Phases:

Rockwell/Johnson School Renovations Project. Existing Conditions September, 2016

TABLE OF CONTENTS. Part I Administrative

Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code

PLANNING COMMISSION. Agenda Item # 3.

Mechanical System Description

FRUCHTMAN & ASSOCIATES

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

SIOUX FALLS FIRE RESCUE STRATEGIC PLAN

What does it take to maintain a campus? What are the costs? UNIVERSITY OF ALASKA FAIRBANKS

WE DESIGN FOR YOU OVER 30 YEARS OF HISTORY AND EXPERIENCE BRW ARCHITECTS FIRE

PROCTOR TERRACE ELEMENTARY SCHOOL

Maintenance Road Show

LOS ANGELES MISSION COLLEGE MASTER PLAN Master Plan DESIGN & DEVELOPMENT PRINCIPLES

UAA School of Engineering Parking Garage Master Plan Amendment. 1. Purpose

Cherry Hill Public Schools BUILDING A SOLID FUTURE

Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS

Allston Brighton Boston College Task Force Meeting. Brighton Marine Health Center March 27, 2013

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Sedona Fire District Fire Station Assessments

SUBJECT: PREDEVELOPMENT PLAN REVIEW OF PROJECT LOCATED AT 2632 EAST WASHINGTON BOULEVARD ('ST. LUKE MEDICAL CENTER')

Sagebrush Elementary School East Temple Place Aurora, Colorado 80015

2013 Compliance Report RCW 52.33

South Lyon Fire Department 2012 Annual Report

This regulation outlines procedures to be followed for fire drills and all school event decorations.

Township of North Kawartha. Report to Council Emergency Services Department

Request Modification of Conditions (Conditional Use Permit for a Church approved by City Council in 1989 & modified in 1990, 2010, and 2014)

DESIGN REVIEW COMMITTEE AGENDA ITEM

TOWN OF JUPITER. Honorable Mayor and Members of Town Council Andrew D. Lukasik, Town Manager

1. Accident Prevention

Standard Features List

CHELAN COUNTY FIRE DISTRICT 5

A Strategic Plan By Steamboat Springs Fire Rescue September 2018

New Jersey Fire Department Overcomes Site Issues, Contaminated Soil, and High Water Table to Build New Fire Headquarters Station

ScratchLotteryTickets.wmv. Yuba City - City Council March 1, 2016 Presentation

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

RED BOOK CONTRACTOR S. Fire Department Access and Design Engineering Information

REPORT TO COUNCIL City of Sacramento

Public Safety Capital Reinvestment 5 Year Plan - $150 million Detail November 8, 2016 VEHICLES

Campus Middle School 4785 South Dayton Street Greenwood Village, Colorado 80111

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

Summary. Introduction

PAOLI FIRE COMPANY. Volunteer Fire and Emergency Ser vice Since Paoli Fire Company Volunteers Save Lives, Property, and Tax Dollars

Operations Maintenance and Evaluations

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

AGENDA. 1. Call to Order. 2. Approval of Minutes. 3. Approval of Invoices and Commitments. 4. Review Updated Site Analysis and Permitting

Mary Bradford, Director of Parks Mike Riley, Deputy Director of Parks John E. Hench, Ph.D., Chief, Park Planning & Stewardship Division

Leadership This is currently a multi-disciplinary effort, led by the following students:

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

CITY OF OWENSBORO OWENSBORO FIRE DEPARTMENT DEPLOYMENT ANALYSIS

Stafford County Strategic Plans

Transcription:

Memorandum CITY OF DALLAS DATE: October 7, 2016 TO: SUBJECT: Honorable Members of the Public Safety Committee: Adam Medrano (Chair), B. Adam McGough (Vice Chair), Sandy Greyson, Tiffinni A. Young, Jennifer S. Gates, Philip T. Kingston Dallas Fire-Rescue Department Recommended Projects for the 2017 Bond Program On Monday, October 10, 2016, you will be briefed on the Dallas Fire-Rescue Department s Recommended Projects for the 2017 Bond Program by Assistant Director Zaida Basora of the Equipment & Building Services Department and Interim Assistant Chief Robert S. Valles of the Dallas Fire-Rescue Department. The briefing materials are attached for your review. Please contact me if you have any questions or need additional information. Eric D. Campbell Assistant City Manager [Attachment] cc: Honorable Mayor and Members of the City Council AC. Gonzalez, City Manager Larry Casto, City Attorney Craig D. Kinton, City Auditor Rosa A. Rios, City Secretary Daniel F. Soils, Administrative Judge Ryan S. Evans, First Assistant City Manager Jill A. Jordan, P.E., Assistant City Manager Mark McDaniel, Assistant City Manager Joey Zapata, Assistant City Manager M. Elizabeth Reich, Chief Financial Officer Sane Syed, Public Information Officer Elsa Cantu. Assistant to the City 1anager Mayor & Council Dallas, The City That Works: Diverse, Vibrant and Progressive

Dallas Fire-Rescue Department Recommended Projects for the 2017 Bond Program Public Safety Committee October 10, 2016

Purpose Review the Fire-Rescue Department s recommended projects for the 2017 Bond Program Discuss issues relating to new and replacement fire stations Present priority ranking list of facilities 2

Fire Stations Currently the City of Dallas has 58 fire stations and owns the following sites for future stations: Jim Miller Rd. and Loop 12 7800 W. Camp Wisdom 4300 Mountain Creek Pkwy. 6700 W. Kiest Blvd. Joseph Hardin and Exchange Note: Future stations at these sites are not funded 3

Background Four new stations, one expansion and fourteen replacement stations funded since 1991: 4 Station Address District Open Replacement Station #23 1660 Corinth St. 4 1991 New Station #29 9830 Shadow Way 10 1993 Replacement Station #26 3303 Sheldon 1 1994 New Station #30 11381 Zodiac 6 1997 Replacement Station #25 2112 56 th St. 8 2002 Replacement Station #34 1234 Carbona 5 2002 Replacement Station #39 2850 Ruidosa 9 2003 Replacement Station #38 2839 Wilhurt 4 2007 New Station #40 Kirnwood and Hampton 8 2007 Replacement Station #35 3800 Walnut Hill 13 2008 Replacement Station #33 754 W. Illinois 3 2008 Replacement Station #42 3333 W. Mockingbird Ln. 14 2008 Expansion Station #10 4451 Frankford Road 12 2010 New Station #50 841 S. Walton Walker Blvd. 6 2012 Replacement Station #37 6780 Greenville Avenue 9 2013 Replacement Station #32 4262 N. Jim Miller Rd. 4 2014 Replacement Station #27 8401 Douglas Avenue 13 2015 Replacement Station #44 Fitzhugh and Lagow 7 2016 Replacement Station #6 2301 Pennsylvania Avenue 7 2016

Background (continued) 5 Bond Program History - New and Replacement Fire Station Construction Funding 2006 Bond Program: 5 replacement, 1 expansion, 1 new 2003 Bond Program: 4 replacement, 1 new 1998 Bond Program: 1 replacement 1995 Bond Program: 1 replacement 1985 Bond Program: 1 replacement, 3 new 1982 Bond Program: 1 replacement, 3 new 1978 Bond Program: 1 renovation, 1 replacement, 1 new 1975 Bond Program: 4 new 1972 Bond Program: 2 replacements, 2 new 1967 Bond Program: 4 replacements, 1 new

Background (continued) Original Fire-Rescue Department Master Plan for New and Replacement Fire Stations created in 1973 Periodically updated based on service needs for new and replacement fire stations EBS and Fire-Rescue Department staff reviewed facilities existing building and site conditions 2017 Needs Inventory totals - $220 million (excl. MM) 19 replacement stations - $175 million 4 new fire stations - $35 million 5000 Dolphin Rd. Campus- $10 million Major maintenance not included- pending FCA 6

Typical Fire Station Building Program Current Fire Station Building Program for new and replacement facilities: Approximately 12,000 square feet 3 full apparatus bays 1 half bay Accommodation of current equipment size and weight On-site apparatus turnaround for backing equipment into bays Parking spaces for 22 vehicles Decontamination room, equipment clean room, vented equipment storage room, areas for administration, physical training, study, laundry, and gender separated shower, restrooms, and dormitory Lobby with accessible public restroom 7

Typical Fire Station Building Program (continued) Standardized facility provides flexibility in coverage and equipment assignment Functional and support spaces and equipment Gender separation in bath / dorm areas Safety of fire fighter personnel Addresses ADA (Americans with Disabilities Act) Assumes site of 1.5 to 2 acres min. Adequate size for safe maneuvering of fire apparatus 8

Evaluation Criteria for New Stations Criteria for New Stations Master Plan needs - service demand drivers Service Response Time Total call volume Population density Building trends and development growth patterns Hazards 9

Evaluation of Existing Stations Existing Stations evaluated for the following: Building performance and life cycle Structural conditions Building envelope and roof Building systems (mechanical, electrical, and plumbing) condition Functional layout - how well the layout facilitates: Service operations Equipment care and storage Livability Location Opportunities for expansion Service response time Ingress and egress 10

Summary of Conditions at Existing Stations There are 58 fire stations across the city 23 Fire Stations included in the Needs Inventory 4 are new stations 19 stations are over 50 years old Most existing fire stations are insufficient in the following respects: Site Considerations Limited opportunity for expansion due to size of existing site Availability of additional adjacent land Short apparatus approaches limit equipment maneuvering and often result in safety risk Limited parking for public and staff 11

Summary of Conditions at Existing Stations (continued) Building Considerations Inadequate bay space, size, configuration, and building foundations do not accommodate state-of-the-art fire fighting and EMS equipment Foundation damage due to settlement (cracking and shifting) Cracked load-bearing and masonry exterior walls Poor roof condition Lack of building insulation Lack of fire-fighting gear storage room, decontamination room, and clean room for fire fighting equipment Poor layout and circulation - inadequate watch office area Inadequate areas for administration, physical training, study, shower, toilet, laundry, kitchen, dining and dormitory No public lobby or restrooms 12

Summary of Conditions at Existing Stations (continued) Building Systems Considerations Not energy efficient Inadequate HVAC systems Air infiltration through windows Poor ventilation in bays and dormitory Plumbing problems with sewage backflow Inadequate kitchen range hoods without built-in fire protection No fire protection systems (sprinklers or alarms) Require extensive Code compliance updates 13

Summary of Conditions at Existing Stations (continued) Many existing stations do not meet National Fire Protection Association (NFPA) recommended standards for equipment and operating conditions: Gender separation restrooms, showers, dorms Decontamination room for equipment Ventilated gear storage 14

Renovation Analysis - Fire Stations Recommended For Replacement None of the fire stations recommended for replacement meet the Building Program or NFPA standards Potential renovation/expansion would require: Substantial renovation effort to meet the design criteria Additional land area, as most existing sites are too small Replacement of all building systems except structure and exterior walls Phased renovation or temporary facilities to maintain current coverage Estimated renovation cost approx. 85% of estimated average replacement cost Replacement is the most cost effective solution Average estimated cost would be $8.5 million 15

Summary of Recommendation Needs Inventory Replacement of 19 Fire Stations $175 million 4 New Fire Stations $35 million 5000 Dolphin Renovation and Burn Building Replacement Total $10 million $220 million 16

Fire Rescue Department s Recommended Priorities Project District 2017 Bond Cost 1. New Station at Jim Miller and Loop 12 4 8.7 M 2. Dolphin Rd. Burn Building Replacement 7/Citywide 2 M 3. Dolphin Rd. Fire Administration Renovation 7 8 M 4. Station 46 Replacement (331 E. Camp Wisdom) 5 8.5 M 5. Station 31 Replacement (9365 Garland Rd.) 9 9.8 M 6. Station 36 Replacement (3241 N. Hampton Rd.) 3 8.9 M 7. Station 4 Replacement (816 Akard St.) 2 10.8 M 8. Station 43 Replacement (2844 LombardyM 6 9.6 M 9. Station 41 Replacement (5920 Royal Ln.) 13 11.3 M 10. Major Maintenance multiple facilities Citywide 5 M Total: $82.6M Bond Program Amount Top ten priorities for DFR 2006 Bond Program included $56.7 M for Fire Rescue facilities 17

1. Jim Miller & Loop 12 $8.7 M Growing neighborhood development Cost estimate includes: Building design, construction - $8.7 million Engine and Rescue - $1 million Station to be designed to meet current station program standards Necessary to meet response time goals Annual staffing / operating cost - $2.5 million 18

2. & 3. 5000 Dolphin Rd. $10 M Renovations Burn Building and Drill Tower Replacement Replace 3-story open drill tower and one story burn building with updated structures Administration Building Renovation Renovation of office and classroom space Existing burn building 19 Proposed examples of burn building and 4-story drill tower

4. Replace Station #46 $8.5 M 331 E. Camp Wisdom 55 years old 2 full bays (undersized), lacks 2 half bays Existing site location limits expansion Insufficient parking Inadequate to current station program needs Site provides insufficient apparatus approach and maneuvering into bays Inadequate areas for gear storage, physical training, study, showers, etc. 20

5. Replace Station #31 $9.8 M 9365 Garland Rd. 69 years old 2 full bays (undersized), lacks 2 half bays Water damage from second floor plumbing problems Insufficient sanitary sewer due to addition of toilet fixtures Existing site location prohibits expansion Insufficient parking (17 spaces) Inadequate to current station program needs Site provides insufficient apparatus approach and maneuvering into bays Heavy traffic at current site sometimes delays response time; difficult ingress and egress Inadequate areas for gear storage, physical training, study, showers, etc. 21

6. Replace Station #36 $8.9 M 3241 N. Hampton Rd. 62 years old 2 full bays (undersized), 1 half bay, lacks 1 half bay Foundation settlement, cracked masonry load bearing walls Existing corner site location prohibits expansion Insufficient parking (15 spaces) Inadequate to current station program needs Site provides insufficient apparatus approach and maneuvering into bays Inadequate areas for gear storage, physical training, study, showers, etc. 22

7. Replace Station #4 $10.8 M 816 S. Akard 65 years old 4 full bays - ladder truck, engine, booster and battalion chief Foundation settlement, cracked masonry load bearing walls Insufficient parking (11 spaces) Inadequate to current station program needs Site provides insufficient apparatus approach and maneuvering into bays Heavy traffic at current site sometimes delays response time Inadequate areas for gear storage, physical training, study, showers, etc. 23

8. Replace Station #43 $9.6 M 2844 Lombardy 58 years old 2 full bays (undersized), 1 half bay, lacks 1 half bay Foundation settlement, concrete spalling at perimeter walls Roof leakage Existing site location prohibits expansion Insufficient parking (11 spaces) Inadequate to current station program needs Inadequate areas for gear storage, physical training, study, showers, etc. 24

9. Replace Station #41 $11.3 M 5920 Royal Lane 57 years old 2 full bays (undersized), 1 half bay, lacks 1 half bay Existing site location prohibits expansion Insufficient sewer, requires cleanout each month Insufficient parking (20 spaces) Inadequate to current station program needs Site provides insufficient apparatus approach and maneuvering into bays Heavy traffic at current site sometimes delays response time Inadequate areas for gear storage, physical training, study, showers, etc. 25