New Versa IC Platform

Similar documents
K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Proudly assembled in U.S.A

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Proudly assembled in U.S.A

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Less Than.25% Lead Proudly Assembled in the U.S.A

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Less Than.25 Pb Proudly made in the U.S.A

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

Less Than.25% Lead Proudly Assembled in the U.S.A

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

B-40/B-41 Modulating Temperature Controller

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Advanced Heating and Hot Water Systems

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

HIGH EFFICIENCY COMMERCIAL BOILERS

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

DIVISION FINNED WATER-TUBE WATER HEATERS

Project Name: Location: Engineer: Contractor: I. GENERAL

WATER-TUBE POOL HEATERS

Hubbell NX500 High Efficiency Gas Condensing Water Heater

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

WATER-TUBE POOL HEATERS

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Proudly assembled in U.S.A

Models HD101 thru 2342B

FINNED WATER-TUBE POOL HEATERS

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

Revitalize Building Mechanical Systems (4619)

HIGH EFFICIENCY COMMERCIAL BOILERS. Thermal Efficiency RIDE THE LOCHINVAR WAVE. Registered under U.S. Patent #9,746,176

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

Service Manual Models: 1.0, 1.3, and 1.5

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

DIVISION FINNED WATER-TUBE WATER HEATERS

INSTALLATION AND OPERATION MANUAL VERSA IC. Integrated Boiler Control ULTRA HIGH EFFICIENCY

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

- Data Brochure Universal Reset Module 423

I/O ZONE 560/583 USERS GUIDE

Trinity Tft/Lx Model #s: Tft60-399/Lx Version Date:

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Installation & Operation Manual

- Essay Control Functions and Benefits

HAWK INTEGRATED BOILER CONTROL SYSTEM

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

- Data Brochure Universal Reset Module 422

Service Manual Models: Series 100 & 101

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Boiler Product Line Brochure

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 264e

Up to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY

Service Manual Models:

Service Manual. w/con X US Interface Models: WARNING

Boiler Product Line Brochure

Triton Series High Efficiency Boiler

Service Manual. w/con X US Interface Models: Series: & WARNING

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Now Available with PVC & Polypropylene Vent Configurations

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Automatic Circulating Water Heaters

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

HeatNet Manual Control Adjustment and Operation Instructions for Hydrotherm Firmware Version 2.8

Service Manual Models:

Service Manual Models:

Hydronic & HVAC Control Systems

- Data Brochure Steam Control 279

Sequence of operation

Raypak Residential Products

97% Thermal Efficiency

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER EASY HEAT, EFFORTLESS COMORT

Power Flame Incorporated

Service Manual Models:

Boiler Product Line Brochure

Sola Hydronic Control. An Eco-Friendly Solution.

Transcription:

New Versa IC Platform

Electronic Temperature Controllers Engineered for Raypak Boilers & Water Heaters Leading-Edge Controllers For over 60 years, Raypak s low-mass, high-recovery designs have set the standard for hot water space heating/supply boilers. To optimize performance and take full advantage of its boilers many benefits, Raypak developed its own specialized controllers whenever standard commercial versions were not adequate. In the 1950s, Raypak led the way in load-tracking modulation, utilizing the ModuSnap controller with its Raytherm boilers. In the early 1980s, Raypak introduced the B-6000, the first true electronic central boiler/bms system for modulating boilers. Today, Raypak s array of temperature controllers offers such state-of-the-art features as: sequence-control of up to 16 boilers; PID technology (see below); optimized approach to outdoor reset; Building Management System interfacing; modulation or stage-firing control; and other energy-saving functions. Unlike off-the-shelf controllers, Raypak s four controller models have been specially designed to maximize the performance of its leading-edge boiler systems. The Right Boiler for the Right Application Raytherm series Rugged, outdoor proven even in the toughest environments, offers exceptional value while being the simplest unit to commission and maintain. With its atmosphericburner, horizontal water-tube design and standard Category I (B-vent) venting for indoor applications, installation is familiar and trouble free. Hi Delta series Also with a horizontal water-tube design, the unit features 100% fan-assisted combustion in on-off or multistage configurations. With multiple venting options and efficiencies that range from 84% to 87%, Raypak has you covered. Full onboard diagnostics in real English. Low NOx compliant in all 50 states. MVB series A vertical-tube boiler with a modulating (4:1), fan-assisted burner offers the smallest (5.4 square feet) installed footprint of its kind and efficiencies of 84% (Cat I) or 87%(Cat IV). Full onboard diagnostics in real English, storing up to 16 reported faults. Low NOx compliant in all 50 states. Lowest required minimum inlet temp 120 F. Fits through a 30 door. XTherm and XFyre series XTherm vertical condensing boiler and XFyre modcon style boilers offer efficiencies up to 99% as well as Centrotherm Polypropylene or PVC venting options. CSA outdoor and indoor rated. True modulation 4:1 XTherm and 5:1 XFyre. Low NOx compliant in all 50 states. XFyre has built-in cascade control for up to 4 units expandable to 16/64. Full onboard diagnostics in real English Controller Applications & Boiler Compatibility At-A-Glance: Applications Using PID Technology to Maximize Performance and Efficiency Setpoint Temperature Typical Proportional (P) Curve Typical PID Curve Time Raypak controllers feature state-of-the-art PID technology, an application of Proportional, Integral and Derivative functions in varying algorithms to optimize system performance. Other controllers on the market either do not utilize PID technology or use only the Proportional (P) function (the component that controls output in proportion to how far the monitored point is from the target temperature). Raypak s controller series also makes use of the Integral (I) function which factors in the time it takes to reach the target temperature and enhances the proportional response accordingly. Add to this the Derivative (D) function which monitors how quickly the monitored point is approaching or drifting away from the target temperature. With all three functions, a properly designed PID-based control achieves set point quickly and levels off at the target temperature with minimal over- or under-shooting. The result is maximum system efficiency and performance. Boilers/Water Heaters Controller Space Heating Hot Water Supply XFyre MVB Hi Delta Raytherm XTherm VERSA IC TempTracker TempTracker Mod TempTracker Mod+Hybrid RayTemp = Available Q2, 2012 = Phased in Q3, Q4 of 2012

TempTracker Multi-Stage Controller TempTracker Mod Modulating Boiler Controller TempTracker stage-controllers are designed to sequence multiple boilers up to four total stages, whether it s one to four on/off boilers, two two-stage boilers, or one boiler with up to four stages. They are available factory-mounted or loose on Hi Delta boilers, and loose on Raytherm boilers. TempTracker Mod is a single-boiler modulating control that is integral to the MVB and XTherm, optional on Raytherm. Both controls can be used for space heating and hot water supply with eight application-specific modes to meet various applications, including outdoor reset for heating systems. The controls monitor and display inlet and outlet temperatures on all applications as well as monitor outdoor temperature when an outdoor reset mode is selected. cé~íìêéë TempTracker - 1-4 boilers/stages TempTracker Mod - 1 MVB (modulating) boiler, XTherm and Raytherm Selectable P or PID logic LCD display NEMA 1 enclosure Boiler inlet and outlet water sensors System water sensor Outdoor air sensor optional Alarm ready (pilot duty) CSA approved 24 VAC, 60 Hz, 3 VA supply power requirement Relay Ratings Stage 1: 5A @ 120 VAC Stages 2 to 4: 3A @ 120 VAC Limp-Along Feature- Ability to operate with as few as 1 of the 3 water sensors. Provides service indication when a sensor fails. BMS 0-10VDC setpoint control BMS 0-10VDC firing rate control Fully Adjustable Outdoor Reset Slope Raypak s custom software allows for complete adjustment of the outdoor reset slope start and end points. System Water Temperature ( F) 190 180 170 160 150 140 130 120 110 100 100 90 80 70 60 50 40 30 20 10 0-10 -20 Outdoor Design Temperature ( F) At right: TempTracker, Target Temperature View mìãé NURøc=båÇáåÖ=t~íÉê qéãééê~íìêé JNMøc=^áê=qÉãéÉê~íìêÉ NMRøc=pí~êíáåÖ=t~íÉê qéãééê~íìêé TMøc=^áê=qÉãéÉê~íìêÉ mìãé B=lìíéìí EcáêáåÖ=o~íÉF _ìêåéê Above: Temptracker Mod, % Output View _ìêåéê cáêáåö pí~öéë 8 programming modes for TempTracker and TempTracker Mod Adjustable outdoor reset ratio Min. system water temperature (70 F) Max. system water temperature Heating: 220 F DHW: 190 F Temperature differential (2 to 42 F) Boiler target (70 to 220 F) Outdoor cutoff (35 to 85 F) Boiler mass (low, med, high) Stage-on delay (P mode) (10 sec. to 8 min.) System pump-off delay (0 to 20 min.) Stage Control only Temperature measurement ( F or C) Boiler pump off delay (0 to 20 min.) Mod Control `ìêêéåí=q~êöéí qéãééê~íìêé Ordering Information (TempTracker) Option No. Description B-26 2-stage setpoint B-27 2-stage outdoor reset B-21 4-stage setpoint B-23 4-stage outdoor reset B-40 Raytherm Mod B-41 Raytherm Mod outdoor reset

TempTracker Mod+ Hybrid Multi-Boiler Modulating Controller The TempTracker MOD+ Hybrid is available as a loose option and controls up to four MVB, XTherm, XFyre and Raytherm boilers for precise load tracking of space heating and hot water supply systems. Expand the control to 16 boilers by adding up to two six-boiler expansion modules. TempTracker Mod+ monitors and displays supply water temperatures on all applications including outdoor temperature when outdoor reset mode is selected. As an added feature, this model offers PID logic as well as automatic or manually selectable lead-lag boiler operation. During boiler servicing or in the event of a controller problem, a manual override feature can be activated to bypass programmed operation. lìíçççê=qéãééê~íìêé póëíéã=qéãééê~íìêé cé~íìêéë 1-4 boilers, expandable to 16 with optional expansion modules Selectable P or PID logic LCD display NEMA 1 enclosure System water and outdoor air sensors 365-day time clock Auto/manual lead-lag and enable/disable functions Manual override DHW override Lockable enclosure UL and cul approved 120 VAC, 60 Hz, 12 VA supply power requirement Relay ratings - 1A inductive; 6A @ 120 VAC 15A total for all circuits Remote Setpoint (4-20 ma) Raypak has highly customized the TempTracker Mod+Hybrid to maximize the overall system efficiency when used with our boilers and water heaters. Hybrid control function for multi boiler installations using condensing and non-condensing boilers. At right: TempTracker Mod+ Hybrid, Standard View _çáäéê cáêáåö=o~íé ié~ç=_çáäéê EfåÇáÅ~íÉÇ=Äó= é~êéåíüéëáëf Selectable modulating outputs (4-20 ma, or 0-10 VDC) Adjustable outdoor reset ratio (1:4 to 4:1) Min. system water temperature (70 to 180 F) Max. system water temperature (90 to 240 F) Automatic/manual lead-lag (1 to 1440 hrs.) Initial setpoint (70 to 240 F) Outdoor cutoff (20 to 100 F) Morning boost (30 min.) Night setback (0 to 75 F) DHW override (with or without priority) System sensor gain (-5 to +5 F) Outdoor sensor offset adjustment (-5 to +5 F) Boiler gain (-10 to +10 F) Boiler-on delay (0 to 60 min) System pump-off delay (0 to 360 min) Standby boiler delay (1 to 60 min) Temperature measurement ( F or C) BACnet MSTP - on/off (9600, 19200, 38400 baud rate) Hybrid system using 2-MVB s and 1-XTherm Ordering Information Option No. Description B-36 4 boilers B-37 10 boilers B-38 16 boilers B-39 Remote setpoint module B-62 BACnet MSTP module

VERSA IC Integrated Control Platform Raypak s all new VERSA IC combines modulating temperature control, safety limits, and ignition programming into one user friendly Integrated Control Platform. It is CSA certified for each of these functions. The same control includes diagnostics to monitor boiler and system faults, provide local alarm, and transmit both to a BMS System via a built in Modbus port. Large (3.5 ) LCD Display, Freeze Protection, and 0-10 VDC Remote Set Point are just a few of many VERSA IC standard features. upgrades. Each VERSA IC has cascade capability for up to 4 boilers, with 16/64 optional. Inlet and outlet sensors are factory installed in each boiler. Remote sensors shipped loose. Controller monitors blower speed and can drive external motorized auxiliaries such as extractors and louvers. Relay for DHW Indirect and remote alarm are provided. VERSA IC is now standard on all models of Raypak XFyre Boilers. It will be phased in to all other types of Raypak Boilers during 2012. Easy front access, facilitates set up and trouble shooting. All low voltage wiring is plug in. Flash memory for future pí~åç~êç=cé~íìêéë 3.5 LCD Display Touch Pad Interface CSA Certified for multiple function 4 boilers/stages, expandable to 16/64 Modulating Selectable P or PID Logic Inlet Sensor Outlet Sensor Individual Boiler Delta T Monitor Remote Set Point, 0 10 VDC Lead / Lag Function Manual Override Full Diagnostics 16 safety/ignition points Two way BMS Communication Modbus Port included Flash Memory for Upgrades Relay Ratings, 5A @ 250 VAC CSA Approved DHW Indirect Sensor Adjustable Outdoor Reset Ratio Parameters Min. System Water Temperature Max. System Water Temperature Lead Lag Rotation Control Band Differential (2 to 10 F ) Setpoint (50 to190 F ) Outdoor Cutoff (35 F to 85 F) Adjustable PID Boiler DHW and System Pump Post Purge (0 to 10 min.) léíáçåë Outdoor Reset Sensor Alarm Bell

RayTemp Demand-Based DHW Controller RayTemp is a demand-based stage set point reset controller for use with single or multiple Raytherm, Hi Delta and MVB hot water supply systems and is available factory-mounted and -wired in Hi Delta units or loose for remote-mounting in single or multiple Hi Delta, MVB or Raytherm systems. RayTemp adjusts water temperature based on system demand to minimize energy consumption during off-peak times. It monitors daily and weekly hot water usage, modifying supply water temperature based upon the most recent history. As a result, unnecessary standby losses, the biggest contributor to energy waste, are eliminated. RayTemp also provides data logging capability for viewing and the ability to download up to 12 months of performance history. Consult your local utility for possible rebates applicable to demand-based controllers, such as RayTemp. All RayTemp models are eligible for the maximum California Energy Rebates. cé~íìêéë 2 or 4 heaters/stages PID logic LCD display NEMA 1 enclosure Tank and building return sensors Demand profile memory Data logging and downloads Password protection Lockable enclosure Supply power requirements Heater-mounted: 24 VAC, 50/60 Hz, 0.8 A Wall-mounted: 120 VAC, 50/60 Hz, 0.17 A Relay ratings - 1.5A @ 24 VAC Up to 4 stages of control Lead/Lag Morning boost and night setback 7-day learning cycle Ordering Information Option No. Description B-24 2-stages B-25 4-stages léíáçåë Modem for remote monitoring and fault notification 4-Stage model only (B-25) Raypak, Inc. 2151 Eastman Avenue Oxnard, CA 93030 (805) 278-5300 phone (805) 872-9725 fax www.raypak.com Cat. No. 5100.22G Effective 01-01-13 Replaces: 11-01-11