HIGH EFFICIENCY CIRCULATOR INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL

Similar documents
Installation and operating instructions. E.2 Series high efficiency circulator

E.2 series high efficiency circulator. Installation and operating instructions

569, 570, 571, 572 Series

INTERMEDIATE GUIDE BRACKET

569, 570, 571, 572 Series

QUICK PRIME INSTALLATION AND SERVICE MANUAL

568X, 587X, 588X Series

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

SUBMERSIBLE SEWAGE PUMP. Automatic and manual models. Single phase power only 115 or 230 volt.

MN908 No. 282C Replaces 282B LB7013

MG200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential and Pressure Sewer Applications.

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

QUICK PRIME INSTALLATION AND SERVICE MANUAL

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

e Bath Fan with Light User s Guide

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

installation, operation & Maintenance manual Floor-mounted Induction units

AeroVent 3X Product Manual

Laundry Kit With flexi-neck faucet and storage cabinet

52 CEILING FAN. Owner s Manual Models #50336, 50337

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Wax Base Heater & Dispenser

Compact Equipment Warranty Policy

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

60In. Ceiling Fan. Owner s Manual

Installation Instructions / Warranty

Troubleshooting the MPH 24FP Series Pedestal Hydrant

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

operator manual Hot Food Server Model HFS This document includes:

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Pressurized Filter Up to 1250 gallons

INSTRUCTIONS FOR OPERATION AND CARE OF

e Bath Fan with Light User s Guide

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Installation and Operating Instructions

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

TOUCHDOWN 48 CEILING FAN

User s Manual and Operating Instructions

OPERATION, SERVICE & PARTS MANUAL

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

e Bath Fan with Light User s Guide

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

User s Manual and Operating Instructions

Operating Instructions & Parts Manual Models 99533, 99532

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

RK/ RK Carbon Monoxide Detector Operator s Manual

INSTRUCTION MANUAL HS-229G

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

ion Genesis Pump Controller

OWNERS INSTRUCTION MANUAL. 221 South Berry Street P.O. Box 1030 Brea, CA Brea, CA Phone: 714/ * Fax: 714/

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

The Monaco Patio. Please read and save these instructions

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

ELSTON 52 CEILING FAN

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

e Heater/Exhaust Fan/Light User s Guide

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

XT Series Thermostats

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

Horizontal Bottle Cooler Installation and Operation Manual

The Zonix OWNER S MANUAL. Ceiling Fan. Model No. FP4620** READ AND SAVE THESE INSTRUCTIONS. Net Weight 9.07 kg (20 lbs)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Instruction Manual for Meat Grinder XMCA-SS

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Industrial Vacuums, Inc

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

RK/ RK Oxygen Detector Operator s Manual

RIGA ZUHNE

20 High velocity Air

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

M Series Fan Filter Units

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

INSTALLATION AND OPERATION INSTRUCTIONS

Transcription:

1070-AP SERIES HIGH EFFICIENCY CIRCULATOR INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part # A-03-333 2012 Pentair Ltd. 11/19/12

SECTION 2 ITEM 1070-AP DATED NOVEMBER 2012 SUPERCEDES MAY 2010 1070-AP SERIES IMPORTANT NOTE TO INSTALLER: Read carefully before installing and operating the circulator. Please leave this manual for the owner s use. the top or side of the motor housing but NOT underneath the motor housing. The piping can be in a horizontal or vertical run. Isolation valves should be installed on the discharge and suction side of the pump to facilitate service. You are about to install a 1070-AP Series circulator a highefficiency pump from Aurora. 1070-AP Series circulators are designed for heating and cooling in hydronic, geothermal or solar systems, circulating water or ethylene or propylene glycol/water solutions. For pumping domestic (potable) water, Aurora recommends the use of circulators with bronze body construction. The 1070-AP Series circulators are extremely efficient and quiet and use a state-of-the-art permanently lubricated bearing system designed for many years of trouble-free operation. They feature a permanent-split capacitor motor with thermal protection. Installation Positions: Recommended Optional Not Recommended CALIFORNIA PROPOSITION 65 WARNING: This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. OPERATING LIMITS: Maximum operating pressure: 150 psi (1034 kpa) Maximum operating temperature: All Standard Models 230 F (110 C) Models Ending in 150 150 F (65 C) Electrical Rating: For models with 1/6 hp motors: 120V, 1 Phase, 60 Hz or 208 / 240V, 1 Phase, 60 Hz For models with 2/5 hp motors: 120V, 1 Phase, 60 Hz or 208 / 240 / 277V, 1 Phase, 60 Hz When unpacking the circulator, inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts. THIS PUMP IS FOR INDOOR USE ONLY. INSTALLATION: Before installing the circulator, proper installation practice recommends a thorough flush of the hydronic system, ensuring removal of all foreign materials prior to installing the circulator. TERMINAL BOX: If the terminal box is found to be positioned inconveniently, it can be rotated as required through 90 increments. See examples shown in Installation Positions. ELECTRICAL WIRING: The electrical wiring must be installed in strict accordance with the U.S. National Electrical Code or the Canadian Electrical Code, as well as local codes and regulations. a. Electrical installation should be conducted by a qualified electrician. b. The motors of 1070-AP Series circulators are designed for 60 Hz, 1 Phase, 120V or 240V service only. (Please refer to the rating label on the circulator s terminal box to determine the correct voltage.) c. Always make sure the electric power is disconnected and locked out before wiring the circulator. d. To wire, loosen the screw from the terminal box cover and remove the screw and cover. e. Install the appropriate size conduit end to one of the holes on either side of the terminal box. f. For 120V models: Referring to Diagram 1 on page 2, connect the hot (black, L ) and neutral (white, N ) leads of the supply wire to the black and white motor leads, respectively, inside the terminal box. Connect the ground wire to any one of the four green ground screws inside the terminal box (use a minimum 18 AWG wire size). Check that the flow direction of the water through the hydronic system matches the arrow on the circulator body. The circulator is supplied for installation with an up discharge direction. The 1070-AP Series circulators can be installed to discharge up or down, horizontally left or right, but the circulator shaft must remain in the horizontal position. It is recommended that the circulator be installed such that the terminal box is installed on 2

1070-AP SERIES SECTION 2 ITEM 1070-AP DATED NOVEMBER 2012 SUPERCEDES MAY 2010 For 208 / 240 / 277V models: Referring to Diagram 2 below, connect the black ( L1 ) and blue ( L2 ) leads of the supply wire to the black and white motor leads, respectively, inside the terminal box. Connect the ground wire to any one of the four green ground screws inside the terminal box (use a minimum 18 AWG wire size). 1070-AP Series circulators are fitted with permanently lubricated ball bearings and DO NOT require lubrication. Disconnect and lock out the power before servicing. REPLACEMENT OF PUMP FROM EXISTING INSTALLATION: Diagram 1 (120V installations) 1. If valves have been installed on the suction and discharge sides of the pump, close them before attempting to remove the circulator from the system. If no valves have been installed, it may be necessary to drain the system. 2. For safety, allow water to cool to 100 F (40 C) before draining the system. It is best to leave the drain valve open while working on the system. Typical wiring diagram for single phase, 120V, 60 Hz power source Diagram 2 (208 / 240 / 277V installations) 3. Ensure that electric power is disconnected and locked out before disconnecting the wiring to the circulator. Then, loosen the screw from the terminal box cover and remove the screw and cover. Disconnect the supply wires only to the circulator, leaving the capacitor wires connected. 4. To relieve any residual pressure which may be present in the pump body, loosen the flange bolts and gently move the pump body back and forth a bit to allow the pressurized water to escape. 5. Remove the flange bolts and nuts and then remove the circulator from the piping. 6. Install the 1070-AP Series circulator where there will be sufficient room for inspection and service. It is recommended that isolation valves be installed on both the suction and discharge sides of the circulator for future servicing (this eliminates the need for draining the system when working on the circulator, for example when replacing the mechanical seal). Typical wiring diagram for a) single phase, 240V, 60 Hz power source, and b) three phase, 208V / 277V, 60 Hz power source g. Replace the terminal box cover. The motor is thermally protected for your safety so overload protection is not necessary. All that is required is a fused plug or circuit breaker in the power line. Electrical information can be found on the nameplate of the motor. START-UP: a. Before starting up the circulator, proper installation practice recommends a thorough flush and draining of the hydronic system, ensuring removal of all foreign materials. Fill the system with clean water or glycol solution before starting. b. Air must be completely vented from the system before starting up the circulator. If the system is not completely vented of air and the circulator is allowed to run dry, the mechanical seal will be damaged. c. When the system has been completely filled and vented, only then can the pump be started. 7. Install suction and discharge flanges on the pipe ends. The use of Teflon tape sealer or a high quality thread sealant is recommended. 8. Pipe strain can be minimized by the use of pipe hangers near the pump, positioned to support the suction and discharge piping. To wire the 1070-AP Series circulator, follow steps c through g in the Electrical Wiring section above, noting that electrical supply and grounding wires must be rated for at least 194 F (90 C). PREVENTIVE MAINTENANCE INSPECTION: Although Aurora long-life circulators are designed to provide years of worry-free service, it is good maintenance practice to inspect the entire hydronic system periodically including the 1070-AP Series circulator for potential problems. If there is any evidence of leakage or damage, repair or replace the pump. INSTRUCTIONS FOR REPLACING MECHANICAL SEAL: (Start by following steps 1 and 2 of section titled REPLACEMENT OF PUMP FROM EXISTING INSTALLATION.) 3

SECTION 2 ITEM 1070-AP DATED NOVEMBER 2012 SUPERCEDES MAY 2010 1070-AP SERIES REPLACEMENT PARTS LIST FOR 1070-AP SERIES CIRCULATORS: Body: Body: Flange Body Impeller Mechanical Motor Motor Motor Model Cast Iron Bronze Hardware Gasket Seal Assembly Assembly Housing Kit 120V 240V Cap Screw (1) (1) (2) (3) (4) (5) (6) (6) (7) 1070-AP7 880200-033 1070-AP8 880200-111 880200-141 810120-244 880200-031 1070-AP9 880200-071 880200-030 880200-082 880200-182 911117-236 1070-AP10 880200-029 880200-011 880200-041 810120-204 1070-AP11 880200-028 1070-AP12-150 880210-182 880210-282 880210-111 880210-141 810120-244 880210-071 880210-035 1070-AP12 880210-082 880210-382 911117-152 1070-AP13 880200-011 880200-041 810120-204 880200-071 880200-034 880200-082 880200-182 911117-236 1070-AP14-150 880210-182 880210-282 880210-111 880210-141 880210-071 880210-035 1070-AP14 810120-244 880210-082 880210-382 911117-152 1070-AP15 880210-411 880210-441 880210-037 880210-182 880210-282 1070-AP16 880200-211 880200-241 810120-212 880200-032 880200-082 880210-182 911117-236 880200-277 1070-AP17 880210-411 880210-441 810120-244 880210-038 1070-AP19 880210-030 1070-AP21 880210-039 1070-AP22 880210-211 880210-241 810120-204 880210-029 1070-AP23 880210-028 880200-071 1070-AP24 880210-032 1070-AP28 880210-131 880210-311 880210-341 810120-208 1070-AP29 880210-132 880210-182 880210-282 911117-152 1070-AP30 880210-011 80210-041 810120-212 880210-036 1070-AP303 880210-311 880210-341 810120-208 880210-036 1070-AP33 880210-011 80210-041 810120-212 1070-AP333 880210-311 880210-341 810120-208 880210-033 4

1070-AP SERIES SECTION 2 ITEM 1070-AP DATED NOVEMBER 2012 SUPERCEDES MAY 2010 1. Turn off the pump leaving it installed in the line. 2. Ensure electrical power is disconnected and locked out. 3. Close the water supply at the points closest to the pump s inlet and outlet. 4. Bleed the water pressure from the pump. 5. Place a pan under the pump to collect the drain water. 6. While holding the motor body, unfasten the four bolts that attach the motor to the pump casing (volute). Start with the two bottom bolts first and remove them, then slowly loosen the top two bolts. Allow the water to drain from the bottom of the pump. When the water has finished draining, remove the two top bolts. Remove the motor straight out from the volute, being careful of its attached impeller. The motor is heavy; do not drop it! 7. Locate the snap bushing in the center of the back of the motor housing and pry it out with a screwdriver. Insert a straight-blade screwdriver into the snap bushing hole and into the slot in the end of the motor shaft to lock the rotor. 8. While holding the rotor (step 7), unscrew the plastic impeller off the motor shaft by hand turning it clockwise (i.e. opposite to most bolts and nuts!). Place the motor on its back, with its shaft up. 9. Remove the rotary part of the mechanical seal by gently pulling it off the shaft. If too tight use two small flat bladed screwdrivers. Gently pry it off the shaft by placing the flat side of the blades onto opposite sides of the mechanical seal. 10. Remove the stationary part of the seal by gently prying it off the steel faceplate. 11. Remove any corrosion present on the stainless steel motor shaft with a nonmetallic brush or scrub pad. Do not use a wire brush or steel wool. 12. Install the new stationary part of the seal into the faceplate: first, the rubber cup by firmly pressing it down until it bottoms, then the ceramic disk. The disk face with a circular groove should be put against the rubber cup (the visible disk face should be smooth). Press the disk firmly down until it too bottoms into the rubber cup. The ceramic disk should be clean. If needed, wipe it with alcohol and a soft cloth. 13. Install the new rotating part of the seal by gently pushing it, by hand, onto the shaft (graphite ring first) until its steel cap stops on the shaft. Check that: a. The height of the steel cap over the ceramic disk is between 0.33" and 0.35" (8.4 mm and 8.9 mm). If it is more than 0.35" (8.9 mm), then try pushing it farther down, carefully, but harder. b. The graphite disk is pressed against the ceramic disk (by a spring inside it). If either (a) or (b) is not happening, then contact Aurora Pump: phone (630) 859-7000 or e-mail ap_applications@pentair.com. 14. "Lock" again the motor rotor and shaft as per step 7 above, in order to perform the next step. 15. Fasten the plastic impeller onto the shaft, turning it by hand counterclockwise until it stops (when it touches the seal's steel cap). Do not tighten it excessively. 16. Ensure the gasket is properly seated in the pump casing (volute) gasket groove. Holding the motor body, insert the impeller straight into the volute. Verify the gasket was not dislodged during insertion and is still seated properly. Hold the motor body steady while fastening the four bolts that attach the motor to the pump casing (volute). Tighten evenly and diagonally. There should be a small, even gap of about 0.02" (0.5 mm) all around between the motor flange and the pump casing (volute). 17. Follow the START-UP instructions and check for leaks. 5

THIS PAGE INTENTIONALLY LEFT BLANK

THIS PAGE INTENTIONALLY LEFT BLANK

WARRANTY Seller warrants equipment (and its component parts) of its own manufacture against defects in materials and workmanship under normal use and service for one (1) year from the date of installation or start-up, or for eighteen (18) months after the date of shipment, whichever occurs first. Seller does not warrant accessories or components that are not manufactured by Seller; however, to the extent possible, Seller agrees to assign to Buyer its rights under the original manufacturer's warranty, without recourse to Seller. Buyer must give Seller notice in writing of any alleged defect covered by this warranty (together with all identifying details, including the serial number, the type of equipment, and the date of purchase) within thirty (30) days of the discovery of such defect during the warranty period. No claim made more than 30 days after the expiration of the warranty period shall be valid. Guarantees of performance and warranties are based on the use of original equipment manufactured (OEM) replacement parts. Seller assumes no responsibility or liability if alterations, non-authorized design modifications and/or non-oem replacement parts are incorporated If requested by Seller, any equipment (or its component parts) must be promptly returned to Seller prior to any attempted repair, or sent to an authorized service station designated by Seller, and Buyer shall prepay all shipping expenses. Seller shall not be liable for any loss or damage to goods in transit, nor will any warranty claim be valid unless the returned goods are received intact and undamaged as a result of shipment. Repaired or replaced material returned to customer will be shipped F.O.B., Seller's factory. Seller will not give Buyer credit for parts or equipment returned to Seller, and will not accept delivery of any such parts or equipment, unless Buyer has obtained Seller's approval in writing. The warranty extends to repaired or replaced parts of Seller's manufacture for ninety (90) days or for the remainder of the original warranty period applicable to the equipment or parts being repaired or replaced, whichever is greater. This warranty applies to the repaired or replaced part and is not extended to the product or any other component of the product being repaired. Repair parts of its own manufacture sold after the original warranty period are warranted for a period of one (1) year from shipment against defects in materials and workmanship under normal use and service. This warranty applies to the replacement part only and is not extended to the product or any other component of the product being repaired. Seller may substitute new equipment or improve part(s) of any equipment judged defective without further liability. All repairs or services performed by Seller, which are not covered by this warranty, will be charged in accordance with Seller's standard prices then in effect. THIS WARRANTY IS THE SOLE WARRANTY OF SELLER AND SELLER HEREBY EXPRESSLY DISCLAIMS AND BUYER WAIVES ALL OTHER WARRANTIES EXPRESSED, IMPLIED IN LAW OR IMPLIED IN FACT, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Seller's sole obligation under this warranty shall be, at its option, to repair or replace any equipment (or its component parts) which has a defect covered by this warranty, or to refund the purchase price of such equipment or part. Under the terms of this warranty, Seller shall not be liable for (a) consequential, collateral, special or liquidated losses or damages; (b) equipment conditions caused by normal wear and tear, abnormal conditions of use, accident, neglect, or misuse of said equipment; (c) the expense of, and loss or damage caused by, repairs or alterations made by anyone other than the Seller; (d) damage caused by abrasive materials, chemicals, scale deposits, corrosion, lightning, improper voltage, mishandling, or other similar conditions; (e) any loss, damage, or expense relating to or resulting from installation, removal or reinstallation of equipment; (f) any labor costs or charges incurred in repairing or replacing defective equipment or parts, including the cost of reinstalling parts that are repaired or replaced by Seller; (g) any expense of shipment of equipment or repaired or replacement parts; or (h) any other loss, damage or expense of any nature. The above warranty shall not apply to any equipment which may be separately covered by any alternate or special warranties. PERFORMANCE: In the absence of Certified Pump Performance Tests, equipment performance is not warranted or guaranteed. Performance curves and other information submitted to Buyer are approximate and no warranty or guarantee shall be deemed to arise as a result of such submittal. All testing shall be done in accordance with Seller's standard policy under Hydraulic Institute procedures. LIABILITY LIMITATIONS: Under no circumstances shall the Seller have any liability under the Order or otherwise for liquidated damages or for collateral, consequential or special damages or for loss of profits, or for actual losses or for loss of production or progress of construction, regardless of the cause of such damages or losses. In any event, Seller's aggregate total liability under the Order or otherwise shall not exceed the contract price. ACTS OF GOD: Seller shall in no event be liable for delays in delivery of the equipment or other failures to perform caused by fires, acts of God, strikes, labor difficulties, acts of governmental or military authorities, delays in transportation or procuring materials, or causes of any kind beyond Seller's control. COMPLIANCE WITH LAW: Seller agrees to comply with all United States laws and regulations applicable to the manufacturing of the subject equipment. Such compliance shall include: The Fair Labor Standards Acts of 1938, as amended; Equal Employment Opportunity clauses of Executive Order 11246, as amended; Occupational Safety and Health Act of 1970 and the standards promulgated thereunder, if applicable. Since compliance with the various Federal, State, and Local laws and regulations concerning occupational health and safety, pollution or local codes are affected by the use, installation and operation of the equipment and other matters over which Seller has no control, Seller assumes no responsibility for compliance with those laws and regulations, whether by way of indemnity, warranty, or otherwise. It is incumbent upon the Buyer to specify equipment which complies with local codes and ordinances. 800 Airport Road North Aurora, Illinois 60542 630-859-7000 www.aurorapump.com