Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Similar documents
TRANBERG HIGH VOLTAGE SOLUTIONS

TRANBERG HIGH VOLTAGE SOLUTIONS

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

TRANBERG HIGH VOLTAGE SOLUTIONS

Fan Heaters Type VLEx

INSTRUCTION & SERVICE MANUAL

Flameproof Manual Call Points Series MCP

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

GENERAL SPECIFICATION ELECTRICAL

Temperature Control and Monitoring. innovations in heat tracing

Inductive slot sensor

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

Sinus Jevi (Explosion-Proof) Condens Heaters

Manual Power relay SR853

Integrated Solutions Low Voltage Systems

Hazardous Area Portable Fan Heater The Bulldog

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX / IECEx)

The next generation thermometer from the global leader

DB4 Range - SPEAKERS - Up to 25 Watts

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Lamp Supply (Recommended)

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

ExPolar Heating System

SET Installation and Operating Instructions. Level switch for one sensor

Certification Supplement Manual

Explosion-proof Immersion Heater Type D-8660

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

Ex LED light fittings

Certification Supplement Manual

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

standards: standards:

Dräger Polytron 5700 IR Detection of flammable gases and vapours

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Documentation. Parallel Heating Cable. Type: ELP

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

CF1 ProVector Explosion-Proof Heaters

Dräger X-am 7000 Multi-Gas Detection

CX1 ProVector Explosion-Proof Heaters

A2S s Company Profile

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Gas cylinder scale Model GCS-1

Technical Data. Dimensions

Certification Supplement Manual

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

TYPE APPROVAL CERTIFICATE

PANELBOARD PROTECTION ON A GLOBAL SCALE

the next generation thermometer from the global leader

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Thermal Management Products & Accessories for Enclosures

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Technical Data. General specifications. Rated operating distance s n 5 mm

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Enclosure Heaters and Fan Heaters

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Explosion Proof Manual Call Points Series MCP

Operating Instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

ELECTRICAL HEATING SYSTEMS ENCLOSURES and JUNCTION BOXES CABLE GLANDS HELIDECK LIGHTING SYSTEM REFERENCES. Helideck

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Approved by: Document no.: EGT

new new Industrial plugs and sockets

Flameproof Manual Call Points Series MCP

CR 027 PTC Fan Heater W

Performance Data. curus Component Recognized; File No. E IP 20

OilSET-1000 (12 VDC)

TX6831 Data Sheet. Features. Benefits

TraceNet ECM Series Control System

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Temperature Measurement Transmitters for field mounting

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

How Limit Switches Can Stop Machines from Going Boom

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Certificate of Compliance

IECEx Certificate of Conformity

Circulation Heaters Selection Guidelines

DB1 Range - HORNS - Up to 103 db(a)

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Transcription:

Enclosure Heaters Zone 1, Zone 2 & Safe Area

CONTACT INFORMATION OFFSHORE SOLUTIONS Subject to change without prior notice TPS2121 REV. D 22.08.2017 Kjetil Tengesdal Sales Director Offshore Solutions Special fields: High Voltage, ExP and ExD T +47 48 08 30 56 E kjetil.tengesdal@stahl-tranberg.com Reidar Abrahamsen Key Account Manager Offshore Solutions Special fields: Heat Tracing, Cable Glands T +47 48 08 30 72 E reidar.abrahamsen@stahl-tranberg.com Roy Mork Sales Engineer Offshore Solutions Special fields: Ex Heater, Tube Trace T +47 48 08 30 78 E roy.mork@tranberg.com Synnøve R. Wiull Sales Support Offshore Solutions Special fields: Wholesales T +47 48 08 30 79 E synnove.wiull@tranberg.com Tor Morten Berge Sales Support Offshore Solutions Special fields: Junction Boxes Exe, Stainless Steel Cabinets T +47 48 08 30 66 E tor.berge@tranberg.com Marco Demmer Sales Engineer Offshore Solutions Special fields: 3D Designs T +47 48 08 30 60 E marco.demmer@stahl-tranberg.com Per Helgeland Marketing Manager T +47 48 08 30 82 E per.helgeland@stahl-tranberg.com

Tranberg Enclosure Heaters Zone 1, Zone 2 & Safe Area Introduction Tranberg quality heater for the professional oil & gas industry. High volumes of heaters delivered to projects worldwide. Compact design - easy to install - high effect output - low maintenance. Stainless steel and acid proof, AISI 316L. 50W - 1000W. Self-limiting or thermostat, external thermostat also possible. Stable effect curve. Very good heat distribution. Purpose To be installed inside junction boxes, cabinets, panels, enclosures, skids, weather protection housings, containers, fi-fi equipment, fire hose cabinets, cabinets for life jackets and survival suits, control rooms, etc. For the purpose of: Prevent moisture/ anti-condensation. Climatic control. Frost protection. Heat up / maintain desired temperature. Heat loss calculation Tranberg can make a heat loss calculation. To calculate the heat loss there are important factors to be considered: Volume and size of enclosure. Insulation (eg. Armaflex) or not? Wind (-speed). Indoor or outdoors. Minimum ambient temperature. Heat up/ temperature maintenance. Frost protection. Series TEF 9202 series, T4, 120V/240V, 50/60 Hz. 50W - 100W. For use in enclosures IP54 or better. TEF 9207 series, T3, 240V, 50/60 Hz. 100W - 1000W. IP66. TEF 9208 series, T4, 240V, 50/60 Hz. 50W - 600W. For use in enclosures IP54 or better. TEF 9209 series, T4, 120V, 50/60 Hz. 50W - 600W. For use in enclosures IP54 or better.

Approvals ATEX (Europe) IEC Ex (worldwide) CSA (USA + Canada) EAC (Russia) Versions Composite heater -self-limiting (fig. 1). With flying lead (1 or 1,5 m cold cable) - self-limiting (fig. 2). With junction box - self-limiting (fig. 3). With junction box + integrated ambient air thermostat +5 C or +15 C (fig. 4). Fig. 4 Fig. 3 Fig. 2 Fig. 1

Tranberg Enclosure Heaters Zone 1, Zone 2 & Safe Area Installation Easy to install - see datasheet / user manual. To be installed in lower half of enclosure - recommended. Vertical / horizontal / flat. Possible positions in enclosure Installed in side wall Installed in door Installed in bottom Installed on mounting plate

A short guide for selection of heater type Heater Type TEF 9202 TEF 9207 TEF 9208 TEF 9209 Input power 120/240 VAC 240 VAC 240 VAC 120 VAC Hertz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Max. circuit breaker 16A 16A 16A 16A Temp. Class T4 T3 T4 T4 For outdoor use (IP66) No IP66 No No For use in enclosure Anti condensation Frost protection Heating For certified enclosure with IP54 or more Any enclosure For certified enclosure with IP54 or more For certified enclosure with IP54 or more Approvals: IECEx ATEX CSA EAC On request On request Available versions: Flying lead 1,5 meter Junction box Junction box and integrated thermostat Available effect 50-100W 100-1000W 50-600W 50-600W Heater Applications TEF 9202 TEF 9207 TEF 9208 TEF 9209 Junction boxes Cabinets Panels Skids Fire hose cabinets Cabinets for survival suits and life jackets Containers Control rooms Weater protection houses 120VAC for US and Canada 240VAC for Russia Installed in fire hose cabinet Installed in junction box Installed in cabinet

ENCLOSURE HEATER TEF 9207 Ex e T3 240 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS3007 REV. P 07.07.2017 Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing. With flying lead electrical connection. Delivered with power output from 100W to 500W at 0 C. TECHNICAL DATA APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. ESTIMATED POWER OUTPUT OF HEATER IN RESPECT TO AMBIENT TEMPERATURE Ex-protection ATEX & IECEx: Ex-protection CSA: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: II 2 G Ex e IIC T3 Gb AEx e II / Ex e II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60 Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Electrical connection: Connect to max. 16A circuit breaker. Earth leakage protection device or insulation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. Flying lead, 2 x 2.5mm2 + PE IP protection: IP66 According to EN 60529 Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432

TEF 9207 ENCLOSURE HEATER DESCRIPTION EL No. Part No. Enclosure heater, 100W @ 0 C 5420930 9207 0001 Enclosure heater, 200W @ 0 C 5420931 9207 0002 Enclosure heater, 300W @ 0 C 5420932 9207 0003 Enclosure heater, 500W @ 0 C 5420933 9207 0005 DIMENSIONS *Nominal output Overall dimensions Mounting dimension Weight Length flying lead A B C D E 100W 200 300 30 190 160 1,62 kg. 1 meter 200W 240 550 30 440 200 3,44 kg. 1,5 meter 300W 280 700 30 590 240 5,42 kg. 1,5 meter 500W 360 870 30 760 320 8,02 kg. 1,5 meter *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 4xØ6 mounting holes on the rear side of the heater. Hold the heater close to the installation surface, and insert the M6 screws in each of the 4 mounting holes. Use a tool to tighten the screws firmly to secure the heater.

ENCLOSURE HEATER TEF 9207 Ex e T3 240 VAC, WITH JUNCTION BOX ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS3008 REV. Q 07.07.2017 Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with power output from 100W to 600W at 0 C. TECHNICAL DATA Sandwich model Ex-protection ATEX and IECEx: Ex-protection CSA: Optional ambient temp. : II 2 G Ex e IIC T3 Gb AEx e II / Ex e II -50 C to +50 C APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. ESTIMATED POWER OUTPUT OF HEATER IN RESPECT TO AMBIENT TEMPERATURE Max. withstand ambient temp.: Nominal voltage: +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. 6mm 2 : 2 + 2 pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs IP protection: IP66 According to EN 60529 Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432

TEF 9207 ENCLOSURE HEATER W/JUNCTION BOX DESCRIPTION El No. Part No. Enclosure heater with junction box, 100W @ 0 C 5420934 9207 1001 Enclosure heater with junction box, 200W @ 0 C 5420935 9207 1002 Enclosure heater with junction box, 300W @ 0 C 5420936 9207 1003 Enclosure heater with junction box, 400W @ 0 C (Sandwich) 5420946 9207 3004 Enclosure heater with junction box, 500W @ 0 C 5420937 9207 1005 Enclosure heater with junction box, 600W @ 0 C (Sandwich) 5420947 9207 3006 Enclosure heater with junction box, 1000W @ 0 C (Sandwich) 5420948 9207 3010 DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W 200 430 30 80 190 160 2,92 kg. 200W 240 684 30 80 440 200 4,74 kg. 300W 280 834 30 80 590 240 6,72 kg. 400W 303 684 80 80 440 276 6,44 kg. 500W 360 1004 30 80 760 320 9,32 kg. 600W 343 834 80 80 590 316 11,76 kg. 1000W 424 1004 80 80 760 397 18,50 kg. *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A108158 4xØ6 mounting holes on the rear side of the heater. Use a tool to tighten the screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. For the sandwich model, insert the M6 screws and a washer in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

ENCLOSURE HEATER TEF 9207 Ex e, T3 240 VAC, WITH JUNCTION BOX AND THERMOSTAT ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS3009 REV. S 07.07.2017 Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with ambient air thermostat, +5 C or +15 C and power output from 100W to 600W at 0 C ambient, still air. TECHNICAL DATA Sandwich model Ex-protection ATEX & IECEx: Ex-protection CSA: Operational ambient temp.: Max. withstand ambient temp.: II 2 G Ex e mb IIC T3 Gb AEx e mb II / Ex e mb II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Ambient air thermostat, integrated in heater junction box. Low maintenance. ESTIMATED POWER OUTPUT OF HEATER IN RESPECT TO AMBIENT TEMPERATURE Nominal voltage: 240V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. 6mm 2 : 2 + 2 pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) Thermostat: 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs 1 pc. ambient air sensing thermostat Switching temp.: +5 C or +15 C Hysteresis: +5 C / -5 C IP protection: IP66 According to EN 60529 Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432

TEF 9207 ENCLOSURE HEATER W/ JUNCTION BOX AND THERMOSTAT DESCRIPTION DIMENSIONS EL No. *Part No. +5 C(+5/-5 C) EL No. *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F *Part No. +15 C(+5/-5 C) Enclosure heater with junction box and thermostat, 100W @ 0 C 5420938 92072401 5420942 92072601 Enclosure heater with junction box and thermostat, 200W @ 0 C 5420939 92072402 5420943 92072602 Enclosure heater with junction box and thermostat, 300W @ 0 C 5420940 92072403 5420944 92072603 Enclosure heater with junction box and thermostat, 500W @ 0 C 5420941 92072405 5420945 92072605 Enclosure heater with junction box and thermostat, 400W @ 0 C (Sandwich) 5420949 92074404 5420952 92074604 Enclosure heater with junction box and thermostat, 600W @ 0 C (Sandwich) 5420950 92074406 5420953 92074606 Enclosure heater with junction box and thermostat, 1000W @ 0 C (Sandwich) 5420951 92074410 5420954 92074610 *Note: Ambient Air Thermostat : +5 C : Switches heater ON at approx. +3 C ambient temperature, and OFF at approx. 11 C ambient temperature Ambient Air Thermostat : +15 C : Switches heater ON at approx. +10 C ambient temperature, and OFF at approx. 20 C ambient temperature 100W 233 430 30 80 190 160 2,92 kg. 200W 245 684 30 80 440 200 4,74 kg. 300W 280 834 30 80 590 240 6,72 kg. 400W 303 684 80 80 440 276 6,44 kg. 500W 360 1004 30 80 760 320 9,32 kg. 600W 343 834 80 80 590 316 11,76 kg. 1000W 424 1004 80 80 760 397 18,50 kg. *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A108158 * INTERNAL CABLES FROM HEATER PLATE (INSTALLED AT TRANBERG FACTORY) Standard model: 4xØ6 mounting holes on the rear side of the heater. Standard model: Use a tool to tighten the 4xM6 screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. Sandwich model: Insert 4xM6 screws and washers in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

ENCLOSURE HEATER TEF 9208 Ex e T4 240 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5003 REV. E 07.07.2017 Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing. With flying lead electrical connection. Delivered with power output from 50W to 300W at 0 C. TECHNICAL DATA APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Ex-protection ATEX & IECEx: Ex-protection CSA: Ex-protection EAC: Operational ambient temp.: Max. withstand ambient temp.: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e II / Ex e II 1Ex e IIC T4 Gb X or 1Ex e mb IIC T4 Gb X -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. Nominal voltage: 240V 50/60 Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X Electrical connection: IP protection: Flying lead, 2 x 2.5mm2 + PE For use in enclosures with IP54 or higher. ATEX certificate No.: Nemko 11ATEX1098X Output accuracy: Approx. ±10% CSA Certificate: 1370701 CSA Master contract: 216432 EAC certificate: No TC: RU C-NO.MШ06.B.00091 Серия RU No 0007345

TEF 9208 ENCLOSURE HEATER DESCRIPTION Part No. Enclosure heater, 50W @ 0 C 9208 0000 Enclosure heater, 100W @ 0 C 9208 0001 Enclosure heater, 175W @ 0 C 9208 0002 Enclosure heater, 300W @ 0 C 9208 0003 DIMENSIONS *Nominal output Overall dimensions Mounting dimension Weight Length flying lead A B C D E 50W 200 300 30 190 160 2 kg. 1 meter 100W 240 550 30 440 200 3 kg. 1 meter 175W 280 700 30 590 240 5 kg. 1,5 meter 300W 360 870 30 760 320 8 kg. 1,5 meter *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 4xØ6 mounting holes on the rear side of the heater. Hold the heater close to the installation surface, and insert the M6 screws in each of the 4 mounting holes. Use a tool to tighten the screws firmly to secure the heater.

ENCLOSURE HEATER TEF 9208 Ex e T4, 240 VAC, WITH JUNCTION BOX ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5004 REV. E 07.07.2017 Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with power output from 100W to 600W at 0 C. Sandwich model TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Ex-protection EAC: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e II / Ex e II 1Ex e IIC T4 Gb X or 1Ex e mb IIC T4 Gb X APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432 EAC certificate: No TC: RU C-NO.MШ06.B.00091 Серия RU No 0007345 Optional ambient temp. : Max. withstand ambient temp.: Nominal voltage: -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. 4mm 2 : 2 + 2 pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) IP protection: 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs Output accuracy: Approx. ±10% For use in enclosures with IP54 or higher.

TEF 9208 ENCLOSURE HEATER W/JUNCTION BOX DESCRIPTION Part No. Enclosure heater with junction box, 100W @ 0 C 9208 1001 Enclosure heater with junction box, 175W @ 0 C 9208 1002 Enclosure heater with junction box, 300W @ 0 C 9208 1003 Enclosure heater with junction box, 600W @ 0 C (Sandwich) 9208 3006 DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W 240 684 30 80 440 200 4,92 kg. 175W 280 834 30 80 590 240 6,74 kg. 300W 360 1004 30 80 760 320 9,72 kg. 600W 424 1004 80 80 760 397 18,76 kg. *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A108158 4xØ6 mounting holes on the rear side of the heater. Use a tool to tighten the screws firmly to secure the heater. For the sandwich model, insert the M6 screws and a washer in the mounting brackets as shown. Use a wrench for tightening the screws firmly. Note! Never install the heater with junction box facing upwards.

ENCLOSURE HEATER TEF 9208 Ex e, T4 240 VAC, WITH JUNCTION BOX AND THERMOSTAT ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5005 REV. G 07.07.2017 Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with ambient air thermostat, +5 C or +15 C and power output from 100W to 600W at 0 C ambient, still air. Sandwich model APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Ex-protection EAC: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e II / Ex e II 1Ex e IIC T4 Gb X or 1Ex e mb IIC T4 Gb X -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60Hz FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Ambient air thermostat, integrated in heater junction box. Low maintenance. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432 EAC certificate: No TC: RU C-NO.MШ06.B.00091 Серия RU No 0007345 Material: AISI 316L / EN 1.4404 Electrical protection: Terminals in junction box: Cable glands: Thermostat: IP protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. 4mm 2 : 2 + 2 pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs 1 pc. TEF E204/622 M25/D2/9mm (Ø11,0-15,0mm),1 pc. TEF 7302 M25 breather/drain plug & TEF 650 M20/M25 stopping plugs Output accuracy: Approx. ±10% 1 pc. ambient air sensing thermostat. Switching temp.: +5 C or +15 C. Hysteresis: +5 C / -5 C For use in enclosures with IP54 or higher.

TEF 9208 ENCLOSURE HEATER W/ JUNCTION BOX AND THERMOSTAT DESCRIPTION *Part No. +5 C(+5/-5 C) *Part No. +15 C(+5/-5 C) Enclosure heater with junction box and thermostat, 100W @ 0 C 92082401 92082601 Enclosure heater with junction box and thermostat, 175W @ 0 C 92082402 92082602 Enclosure heater with junction box and thermostat, 300W @ 0 C 92082403 92082603 Enclosure heater with junction box and thermostat, 600W @ 0 C (Sandwich) 92084406 92084606 *Note: Ambient Air Thermostat : +5 C : Switches heater ON at approx. +3 C ambient temperature, and OFF at approx. 11 C ambient temperature Ambient Air Thermostat : +15 C : Switches heater ON at approx. +10 C ambient temperature, and OFF at approx. 20 C ambient temperature DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W 245 684 30 80 440 200 4,92 kg. 175W 280 834 30 80 590 240 6,74 kg. 300W 360 1004 30 80 760 320 9,72 kg. 600W 424 1004 80 80 760 397 18,76 kg. *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A108158 * INTERNAL CABLES FROM HEATER PLATE (INSTALLED AT TRANBERG FACTORY) Standard model: 4xØ6 mounting holes on the rear side of the heater. Standard model: Use a tool to tighten the 4xM6 screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. Sandwich model: Insert 4xM6 screws and washers in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

ENCLOSURE HEATER TEF 9209 Ex e T4 120 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5065 REV. D 07.07.2017 Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing. With flying lead electrical connection. Delivered with power output from 50W to 300W at 0 C. TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e mb II / Ex e mb II APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 120V 50/60 Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. Electrical protection: Electrical connection: IP protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. Flying lead, 2 x 2.5mm2 + PE For use in enclosures with IP54 or higher. Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432

TEF 9209 ENCLOSURE HEATER DESCRIPTION Part No. Enclosure heater, 50W @ 0 C 9209 5000 Enclosure heater, 100W @ 0 C 9209 5001 Enclosure heater, 175W @ 0 C 9209 5002 Enclosure heater, 300W @ 0 C 9209 5003 DIMENSIONS *Nominal output Overall dimensions Mounting dimension Weight Length flying lead A B C D E 50W 200 300 30 190 160 2 kg. 1 meter 100W 240 550 30 440 200 3 kg. 1 meter 175W 280 700 30 590 240 5 kg. 1,5 meter 300W 360 870 30 760 320 8 kg. 1,5 meter *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 4xØ6 mounting holes on the rear side of the heater. Hold the heater close to the installation surface, and insert the M6 screws in each of the 4 mounting holes. Use a tool to tighten the screws firmly to secure the heater.

ENCLOSURE HEATER TEF 9209 Ex e T4, 120 VAC, WITH JUNCTION BOX ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5066 REV. D 07.07.2017 Standard model Sandwich model APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with power output from 100W to 600W at 0 C. TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Optional ambient temp. : Max. withstand ambient temp.: Nominal voltage: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e mb II / Ex e mb II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 120V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. 4mm 2 : 2 + 2 pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) IP protection: 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs Output accuracy: Approx. ±10% For use in enclosures with IP54 or higher. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432

TEF 9209 ENCLOSURE HEATER W/JUNCTION BOX DESCRIPTION Part No. Enclosure heater with junction box, 100W @ 0 C 9209 6001 Enclosure heater with junction box, 175W @ 0 C 9209 6002 Enclosure heater with junction box, 300W @ 0 C 9209 6003 Enclosure heater with junction box, 600W @ 0 C (Sandwich) 9209 8006 DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W 240 684 30 80 440 200 4,92 kg. 175W 280 834 30 80 590 240 6,74 kg. 300W 360 1004 30 80 760 320 9,72 kg. 600W 424 1004 80 80 760 397 18,76 kg. *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A108158 4xØ6 mounting holes on the rear side of the heater. Use a tool to tighten the screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. For the sandwich model, insert the M6 screws and a washer in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

ENCLOSURE HEATER TEF 9209 Ex e, T4 120 VAC, WITH JUNCTION BOX AND THERMOSTAT ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5067 REV. D 07.07.2017 Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with ambient air thermostat, +5 C or +15 C*(see page 2) and power output from 100W to 600W at 0 C ambient, still air. Sandwich model TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e mb II / Ex e mb II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 120V 50/60Hz APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Inrush Current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN 1.4404 Electrical protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Ambient air thermostat, integrated in heater junction box. Low maintenance. Terminals in junction box: Cable glands: Thermostat: IP protection: 6mm 2 : 2 + 2 pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs 1 pc. TEF E204/622 M25/D2/9mm (Ø11,0-15,0mm),1 pc. TEF 7302 M25 breather/drain plug & TEF 650 M20/M25 stopping plugs 1 pc. ambient air sensing thermostat. Switching temp.: +5 C or +15 C. Hysteresis: +5 C / -5 C For use in enclosures with IP54 or higher. Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM 11.0005X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: 1370701 CSA Master contract: 216432

TEF 9209 ENCLOSURE HEATER W/ JUNCTION BOX AND THERMOSTAT DESCRIPTION *Part No. +5 C(+5/-5 C) *Part No. +15 C(+5/-5 C) Enclosure heater with junction box and thermostat, 100W @ 0 C 92097401 92097601 Enclosure heater with junction box and thermostat, 175W @ 0 C 92097402 92097602 Enclosure heater with junction box and thermostat, 300W @ 0 C 92097403 92097603 Enclosure heater with junction box and thermostat, 600W @ 0 C (Sandwich) 92099406 92099606 *Note: Ambient Air Thermostat : +5 C : Switches heater ON at approx. +3 C ambient temperature, and OFF at approx. 11 C ambient temperature Ambient Air Thermostat : +15 C : Switches heater ON at approx. +10 C ambient temperature, and OFF at approx. 20 C ambient temperature DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W 245 684 80 80 440 200 4,92 kg. 175W 280 834 80 80 590 240 6,74 kg. 300W 360 1004 80 80 760 320 9,72 kg. 600W 424 1004 80 80 760 397 18,76 kg. *Note: Nominal at still air @0 C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A108158 * INTERNAL CABLES FROM HEATER PLATE (INSTALLED AT TRANBERG FACTORY) Standard model: 4xØ6 mounting holes on the rear side of the heater. Standard model: Use a tool to tighten the 4xM6 screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. Sandwich model: Insert 4xM6 screws and washers in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

ENCLOSURE HEATER TEF 9202 COMPOSITE Ex e T4 120/240 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5559 REV. C 07.07.2017 Globally approved Ex e, self regulating enclosure heater. Made of light weight composite material. TECHNICAL DATA Composite APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Temperature maintenance. Anti-condensation. FEATURES AND BENEFITS Ex-protection ATEX & IECEx: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: Material: Electrical protection: IP protection: Flying lead: II 2 G Ex e IIC T4 Gb -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is de-energized) 120V/240V 50/60Hz Composite material Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN60079-7 Annex D. For use in enclosures with IP54 or higher. 1,5m, 2x2,5mm 2 + PE Light weight composite structure. Compact. Easy to install. Can be supplied with DIN rail module. Self regulating heating element. Prevents overheating. Low maintenance. Corrosion proof. Fire resistant retardant UL 94, Classification V-0. Low inrush current. APPROVALS AND CERTIFICATES IECEx PRE 17.0016X Presafe 17ATEX9667X

TEF 9202 ENCLOSURE HEATER W/ FLYING LEAD DESCRIPTION Part No. Enclosure Heater Ex 240V-50W T4 Composite with flying lead @ 0 C 9202010 Enclosure Heater Ex 240V-100W T4 Composite with flying lead @ 0 C 9202011 Enclosure Heater Ex 120V-50W T4 Composite with flying lead @ 0 C 9202050 Enclosure Heater Ex 120V-100W T4 Composite with flying lead @ 0 C 9202051 Optional DIN rail bracket 50520075 DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E 50W 180 300 30 140 201 0,56 kg. 100W 180 300 30 140 201 0,76 kg. *Note: Nominal at still air @ 0 C 000A110768 Optional DIN rail module, can be placed in both horizontal and vertical position.

TRANBERG AS COMPANY DETAILS Subject to change without prior notice TPS2082 REV. B 30.06.2017 Products designed and manufactured in close cooperation with demanding customers have enabled Tranberg to supply the oil and gas industry with high quality electro mechanical products with low life time cost and high functionality. OFFSHORE SOLUTIONS When reliability matters. No matter it it`s within arctic or tropical conditions. Tranberg Offshore Solutions are performing under harsh and hazardous environment. Furthermore Tranberg is the exclusive distributor for Thermon - the world s leading manufacturer of heating cables - in Norway. Primarily active within the offshore and petrochemical industry. We can supply complete solutions from individual components to complete heat tracing systems for the following applications: Winterization of pipe systems, instruments, tanks and vessels Temperature maintenance of pipes, tanks and vessels Anti-icing/de-icing of helideck, safety and emergency areas Electrical process heating Products are developed and testet together with offshore vessel ship owners for world wide operations in both arctic and tropic environments. If the product are good enough for them, they are good enough for you. MARINE SOLUTIONS When durability matters. Tranberg Marine Solutions are the No. 1 Supplier for Offshore Vessels Tranberg supplies products within the following areas for ships: Marine Lighting Helideck Lighting Audible and Visual Signals Electrical De-Ice/ Anti-Ice Installation Equipment Helideck equipment manufactured by Tranberg is delivered to offshore installations, oil tankers, ships, hotels and hospitals all over the world. Helideck equipment from Tranberg is used for operation on elevated and non-elevated helidecks. HELIDECK SOLUTIONS When safety matters. Tranberg Helideck Solutions is the market leader for operation on elevated and non-elevated helidecks. All helideck lighting products from Tranberg: Compact and rugged construction Integrated terminal box LED lights with very long operating life ( up to 50.00 hours ) All products complies with : ICAO latest standards Resistance to vibration Quick opening for installation Products certified for use in Zone 1, Zone 2 and Safe Area, IECEx

TGP5708 REV. B 22.08.2017 (PUBLIKASJON 620 AXAPTA) References Edvard Grieg Aasta Hansteen Ivar Aasen Mariner Gina Krogh projects Johan Sverdrup project Goliat project.. Martin Linge Johan Castberg Yamal project: 15000 (!) heaters R.Stahl Tranberg AS Main office Strandsvingen 6 N-4032 Stavanger, Norway T (47)51 57 89 00 F (47)51 57 89 50 Oslo office Luhrtoppen 2 N-1470 Lørenskog, Norway T (47)24 08 44 10