HERMES Alternatives for Q Panel technical data Composition and General Features Technical variants Technical Panel one door 1250 x 1050 x 195 mm Technical panel two doors without gases 1250 x 1500 x 195 mm Main unit or PLC (programming software): information management. PC + Touch screen: allows visualization and control of parameters. Available screens: 15. CPU: Intel ATOM Dual Core. 2xRS-232, 1xRJ-45, 5xUSB 2.0, 1xAudio Port, 1xVGA Port, 1xPower Jack, 1xHDMI port, 1xDVI-D port, 1xRJ-45 (optional) Digital speakers and microphone (optional). Camera (optional). Wireless LAN 802.11 Possibility of incorporating different elements: Control individualized cards with different functions: - Batteries State Control - UPS Status - Operating Room Status Indicator Possibility of incorporating Electrical Alarm Repeater and Gas Alarm Repeater 1250 x 1700 x 195 mm Technical panel three doors without gases 1902 x 1500 x 195 mm Technical panel three doors with gases 1902 x 1700 x 195 mm Net weights Depending on the needs of the model. Frequent used functions -Perimetral Light Switch Technical panel two doors with gases Controls Electrical System Perimeter and / or endoscopy lights switches (3pcs). Dimming upgradeable. Temperature and humidity display. If information about communications protocol of general air conditioning system is available, it is possible to manage both within an interval. Display of the operating room differential pressure. Operation theatre status (occupied / free / cleaning). Stopwatch control (4 pcs. Internal and 1 external). OT lamp switch (depending on the lamp model). Rated voltage 120/230V Rated frequency Rated current 60/50Hz 10A or 16A per circuit. 20A and 25A optional Gas system Medical gases: Oxygen and protoxide Digital clock & Stopwatch with control. Analog clock with battery. Alarms Installing Telephone Handsfree, both digital and analog model. Incorporation of gas outlets in a completely separate compartment. Compressed air-nitrogen supply to air motors Electrical alarm repeater (visual and acoustic). Gases alarm repeater (visual and acoustic). UPS charging status. Batteries charging status. Alarm associated with internal stopwatch. Historical records. Vacuum 5 bar 10bar 5bar Evacuation of anesthetic gases Use Communications Manual strength < 150N IP Telephone available upon request. Ethernet connection. E-mail Alarms available. Compact and integrated Q Panel Oxygen and protoxide Compressed gases Classification Following the directive 93/42/EEC: CLASE I without gases/class II b with gases. Standard signals The operating room is the place where we find a greater number of medical equipment. The compact Q Panel is designed to centralize all the elements of an operating room. It is able to adapt all kinds of elements of other brands such as screens, electronic systems or alarm systems. It is completely integrated into the wall. Clínica Delgado, Lima Perú Central Hospital Pvt ltd, Sri Lanka Micro Filtration Techonology Madrid España Barcelona España Hospital Clínic, Barcelona España Tedisel products may be equipped with medical devices from other manufacturers. Please follow the instructions provided by the manufacturers of this equipment for proper installation. Tedisel, as medical device manufacturer, has the medical device manufacturer license P.S number 6205, granted by the Spanish Agency for Medicines and Health Products Cuban Hospital, Qatar Hospital Vall d Hebron, Compatibility with other elements Spanish English (other languages upon request) Tedisel Management System and all our products are certified with quality seal ISO 9001, ISO 13485 and CE marking granted by notified body TÜV RHEINLAND. Singapore Hospital Internacional Ruber, Available languages Tedisel complies with the provisions of Directive 93/42 / EEC (medical devices), ISO 11197 (medical supply units) and ISO 13485 (related to medical gases supply). All medical devices developed and manufactured in Tedisel, are regulated by the European Directive 93/42 / EEC. All equipment has accreditation and certification of electrical safety and electromagnetic compatibility standards ISO 11197 and EN 60601. Q Panel Surgical facility panels for Operating Theatre Management System EN ISO 13485:2012 ISO 9001:2008 www.tuv.com ID 0000025756 0197 Sant Lluc, 69-81 08918 Badalona, BARCELONA, Spain Tel. +34 93 399 20 58 Fax +34 93 398 45 47 info@tedisel.com www.tedisel.com 10-2016 globus.es National University Hospital, Clínica Fátima, Sevilla España EC Conformity quality Algunas referencias: Pte Ltd, Singapore Digital: Inputs/outputs (14pcs/10pcs). Analog: (0-10V): Inputs/outputs (2pcs/1pc). The unit can be upgraded by adding modules increasing the number of inputs and outputs.
Centralized Control and Display in the Operating Theatre Q Panel in detail Digital control panel Hermes is a digital control panel, managed by a PLC and comprised by PC and touchscreen. It integrates all the control elements, signals and alarms of the operating theatre and offers numerous services, specially aimed at the maintenance personnel. Maintenance The technical panel can be accessed in two ways: from the interior or exterior of the operating theatre. Interior access: it will be inspected by means of hinged doors; in the case it is done from outside of the operating theatre Exterior access: Panel with a single hinge door, located in the rear section, accessible from the septic hall. Visualization and monitoring screen Flexible Available sizes: 42 ~ 48 Customizable, depending on the needs of the operating theatre area. Hygienic Its inert and non-porous material makes it ideal to maintain the required asepsis in the operating theatre. Design New design based on smooth surfaces flush with all elements or integrated within the panel. Panel materials The panel is made of Solid Surface or phenolic resin combined with crystals for medical use, which vary depending on type and size of its functionality Design adaptable to the functional and the dimensions of the operating room. Material characteristics: Non-porous, indicated for strict asepsis environments such as operating theatres. Inert, in the case of fire, the gases of its combustion are not toxic. QP It is completely waterproof it is ideal for use in Hospitals, operating theatre/surgery areas The crystals are: Antireflective Medical grade. Innovative Image Management System Integrated elements Easy and intuitive touchscreen control. Stopwatch & Digital Clock. Robust retransmission and image recording. Electrical outlets with cover Capacitive Push buttons integrated. Sound amplification system Patch panel integrated, with video, audio and data sockets Medical keyboard. Vitrified, being opaque and transparent Surface according to the areas that require or display. The combination of Solid Surface and tinted glass, give the Panel an innovative aesthetic with a smooth finish for easy cleaning.
HERMES Alternatives for Q Panel technical data Composition and General Features Technical variants Technical Panel one door 1250 x 1050 x 195 mm Technical panel two doors without gases 1250 x 1500 x 195 mm Main unit or PLC (programming software): information management. PC + Touch screen: allows visualization and control of parameters. Available screens: 15. CPU: Intel ATOM Dual Core. 2xRS-232, 1xRJ-45, 5xUSB 2.0, 1xAudio Port, 1xVGA Port, 1xPower Jack, 1xHDMI port, 1xDVI-D port, 1xRJ-45 (optional) Digital speakers and microphone (optional). Camera (optional). Wireless LAN 802.11 Possibility of incorporating different elements: Control individualized cards with different functions: - Batteries State Control - UPS Status - Operating Room Status Indicator Possibility of incorporating Electrical Alarm Repeater and Gas Alarm Repeater 1250 x 1700 x 195 mm Technical panel three doors without gases 1902 x 1500 x 195 mm Technical panel three doors with gases 1902 x 1700 x 195 mm Net weights Depending on the needs of the model. Frequent used functions -Perimetral Light Switch Technical panel two doors with gases Controls Electrical System Perimeter and / or endoscopy lights switches (3pcs). Dimming upgradeable. Temperature and humidity display. If information about communications protocol of general air conditioning system is available, it is possible to manage both within an interval. Display of the operating room differential pressure. Operation theatre status (occupied / free / cleaning). Stopwatch control (4 pcs. Internal and 1 external). OT lamp switch (depending on the lamp model). Rated voltage 120/230V Rated frequency Rated current 60/50Hz 10A or 16A per circuit. 20A and 25A optional Gas system Medical gases: Oxygen and protoxide Digital clock & Stopwatch with control. Analog clock with battery. Alarms Installing Telephone Handsfree, both digital and analog model. Incorporation of gas outlets in a completely separate compartment. Compressed air-nitrogen supply to air motors Electrical alarm repeater (visual and acoustic). Gases alarm repeater (visual and acoustic). UPS charging status. Batteries charging status. Alarm associated with internal stopwatch. Historical records. Vacuum 5 bar 10bar 5bar Evacuation of anesthetic gases Use Communications Manual strength < 150N IP Telephone available upon request. Ethernet connection. E-mail Alarms available. Compact and integrated Q Panel Oxygen and protoxide Compressed gases Classification Following the directive 93/42/EEC: CLASE I without gases/class II b with gases. Standard signals The operating room is the place where we find a greater number of medical equipment. The compact Q Panel is designed to centralize all the elements of an operating room. It is able to adapt all kinds of elements of other brands such as screens, electronic systems or alarm systems. It is completely integrated into the wall. Clínica Delgado, Lima Perú Central Hospital Pvt ltd, Sri Lanka Micro Filtration Techonology Madrid España Barcelona España Hospital Clínic, Barcelona España Tedisel products may be equipped with medical devices from other manufacturers. Please follow the instructions provided by the manufacturers of this equipment for proper installation. Tedisel, as medical device manufacturer, has the medical device manufacturer license P.S number 6205, granted by the Spanish Agency for Medicines and Health Products Cuban Hospital, Qatar Hospital Vall d Hebron, Compatibility with other elements Spanish English (other languages upon request) Tedisel Management System and all our products are certified with quality seal ISO 9001, ISO 13485 and CE marking granted by notified body TÜV RHEINLAND. Singapore Hospital Internacional Ruber, Available languages Tedisel complies with the provisions of Directive 93/42 / EEC (medical devices), ISO 11197 (medical supply units) and ISO 13485 (related to medical gases supply). All medical devices developed and manufactured in Tedisel, are regulated by the European Directive 93/42 / EEC. All equipment has accreditation and certification of electrical safety and electromagnetic compatibility standards ISO 11197 and EN 60601. Q Panel Surgical facility panels for Operating Theatre Management System EN ISO 13485:2012 ISO 9001:2008 www.tuv.com ID 0000025756 0197 Sant Lluc, 69-81 08918 Badalona, BARCELONA, Spain Tel. +34 93 399 20 58 Fax +34 93 398 45 47 info@tedisel.com www.tedisel.com 10-2016 globus.es National University Hospital, Clínica Fátima, Sevilla España EC Conformity quality Algunas referencias: Pte Ltd, Singapore Digital: Inputs/outputs (14pcs/10pcs). Analog: (0-10V): Inputs/outputs (2pcs/1pc). The unit can be upgraded by adding modules increasing the number of inputs and outputs.
Centralized Control and Display in the Operating Theatre Q Panel in detail Digital control panel Hermes is a digital control panel, managed by a PLC and comprised by PC and touchscreen. It integrates all the control elements, signals and alarms of the operating theatre and offers numerous services, specially aimed at the maintenance personnel. Maintenance The technical panel can be accessed in two ways: from the interior or exterior of the operating theatre. Interior access: it will be inspected by means of hinged doors; in the case it is done from outside of the operating theatre Exterior access: Panel with a single hinge door, located in the rear section, accessible from the septic hall. Visualization and monitoring screen Flexible Available sizes: 42 ~ 48 Customizable, depending on the needs of the operating theatre area. Hygienic Its inert and non-porous material makes it ideal to maintain the required asepsis in the operating theatre. Design New design based on smooth surfaces flush with all elements or integrated within the panel. Panel materials The panel is made of Solid Surface or phenolic resin combined with crystals for medical use, which vary depending on type and size of its functionality Design adaptable to the functional and the dimensions of the operating room. Material characteristics: Non-porous, indicated for strict asepsis environments such as operating theatres. Inert, in the case of fire, the gases of its combustion are not toxic. QP It is completely waterproof it is ideal for use in Hospitals, operating theatre/surgery areas The crystals are: Antireflective Medical grade. Innovative Image Management System Integrated elements Easy and intuitive touchscreen control. Stopwatch & Digital Clock. Robust retransmission and image recording. Electrical outlets with cover Capacitive Push buttons integrated. Sound amplification system Patch panel integrated, with video, audio and data sockets Medical keyboard. Vitrified, being opaque and transparent Surface according to the areas that require or display. The combination of Solid Surface and tinted glass, give the Panel an innovative aesthetic with a smooth finish for easy cleaning.
Centralized Control and Display in the Operating Theatre Q Panel in detail Digital control panel Hermes is a digital control panel, managed by a PLC and comprised by PC and touchscreen. It integrates all the control elements, signals and alarms of the operating theatre and offers numerous services, specially aimed at the maintenance personnel. Maintenance The technical panel can be accessed in two ways: from the interior or exterior of the operating theatre. Interior access: it will be inspected by means of hinged doors; in the case it is done from outside of the operating theatre Exterior access: Panel with a single hinge door, located in the rear section, accessible from the septic hall. Visualization and monitoring screen Flexible Available sizes: 42 ~ 48 Customizable, depending on the needs of the operating theatre area. Hygienic Its inert and non-porous material makes it ideal to maintain the required asepsis in the operating theatre. Design New design based on smooth surfaces flush with all elements or integrated within the panel. Panel materials The panel is made of Solid Surface or phenolic resin combined with crystals for medical use, which vary depending on type and size of its functionality Design adaptable to the functional and the dimensions of the operating room. Material characteristics: Non-porous, indicated for strict asepsis environments such as operating theatres. Inert, in the case of fire, the gases of its combustion are not toxic. QP It is completely waterproof it is ideal for use in Hospitals, operating theatre/surgery areas The crystals are: Antireflective Medical grade. Innovative Image Management System Integrated elements Easy and intuitive touchscreen control. Stopwatch & Digital Clock. Robust retransmission and image recording. Electrical outlets with cover Capacitive Push buttons integrated. Sound amplification system Patch panel integrated, with video, audio and data sockets Medical keyboard. Vitrified, being opaque and transparent Surface according to the areas that require or display. The combination of Solid Surface and tinted glass, give the Panel an innovative aesthetic with a smooth finish for easy cleaning.
HERMES Alternatives for Q Panel technical data Composition and General Features Technical variants Technical Panel one door 1250 x 1050 x 195 mm Technical panel two doors without gases 1250 x 1500 x 195 mm Main unit or PLC (programming software): information management. PC + Touch screen: allows visualization and control of parameters. Available screens: 15. CPU: Intel ATOM Dual Core. 2xRS-232, 1xRJ-45, 5xUSB 2.0, 1xAudio Port, 1xVGA Port, 1xPower Jack, 1xHDMI port, 1xDVI-D port, 1xRJ-45 (optional) Digital speakers and microphone (optional). Camera (optional). Wireless LAN 802.11 Possibility of incorporating different elements: Control individualized cards with different functions: - Batteries State Control - UPS Status - Operating Room Status Indicator Possibility of incorporating Electrical Alarm Repeater and Gas Alarm Repeater 1250 x 1700 x 195 mm Technical panel three doors without gases 1902 x 1500 x 195 mm Technical panel three doors with gases 1902 x 1700 x 195 mm Net weights Depending on the needs of the model. Frequent used functions -Perimetral Light Switch Technical panel two doors with gases Controls Electrical System Perimeter and / or endoscopy lights switches (3pcs). Dimming upgradeable. Temperature and humidity display. If information about communications protocol of general air conditioning system is available, it is possible to manage both within an interval. Display of the operating room differential pressure. Operation theatre status (occupied / free / cleaning). Stopwatch control (4 pcs. Internal and 1 external). OT lamp switch (depending on the lamp model). Rated voltage 120/230V Rated frequency Rated current 60/50Hz 10A or 16A per circuit. 20A and 25A optional Gas system Medical gases: Oxygen and protoxide Digital clock & Stopwatch with control. Analog clock with battery. Alarms Installing Telephone Handsfree, both digital and analog model. Incorporation of gas outlets in a completely separate compartment. Compressed air-nitrogen supply to air motors Electrical alarm repeater (visual and acoustic). Gases alarm repeater (visual and acoustic). UPS charging status. Batteries charging status. Alarm associated with internal stopwatch. Historical records. Vacuum 5 bar 10bar 5bar Evacuation of anesthetic gases Use Communications Manual strength < 150N IP Telephone available upon request. Ethernet connection. E-mail Alarms available. Compact and integrated Q Panel Oxygen and protoxide Compressed gases Classification Following the directive 93/42/EEC: CLASE I without gases/class II b with gases. Standard signals The operating room is the place where we find a greater number of medical equipment. The compact Q Panel is designed to centralize all the elements of an operating room. It is able to adapt all kinds of elements of other brands such as screens, electronic systems or alarm systems. It is completely integrated into the wall. Clínica Delgado, Lima Perú Central Hospital Pvt ltd, Sri Lanka Micro Filtration Techonology Madrid España Barcelona España Hospital Clínic, Barcelona España Tedisel products may be equipped with medical devices from other manufacturers. Please follow the instructions provided by the manufacturers of this equipment for proper installation. Tedisel, as medical device manufacturer, has the medical device manufacturer license P.S number 6205, granted by the Spanish Agency for Medicines and Health Products Cuban Hospital, Qatar Hospital Vall d Hebron, Compatibility with other elements Spanish English (other languages upon request) Tedisel Management System and all our products are certified with quality seal ISO 9001, ISO 13485 and CE marking granted by notified body TÜV RHEINLAND. Singapore Hospital Internacional Ruber, Available languages Tedisel complies with the provisions of Directive 93/42 / EEC (medical devices), ISO 11197 (medical supply units) and ISO 13485 (related to medical gases supply). All medical devices developed and manufactured in Tedisel, are regulated by the European Directive 93/42 / EEC. All equipment has accreditation and certification of electrical safety and electromagnetic compatibility standards ISO 11197 and EN 60601. Q Panel Surgical facility panels for Operating Theatre Management System EN ISO 13485:2012 ISO 9001:2008 www.tuv.com ID 0000025756 0197 Sant Lluc, 69-81 08918 Badalona, BARCELONA, Spain Tel. +34 93 399 20 58 Fax +34 93 398 45 47 info@tedisel.com www.tedisel.com 10-2016 globus.es National University Hospital, Clínica Fátima, Sevilla España EC Conformity quality Algunas referencias: Pte Ltd, Singapore Digital: Inputs/outputs (14pcs/10pcs). Analog: (0-10V): Inputs/outputs (2pcs/1pc). The unit can be upgraded by adding modules increasing the number of inputs and outputs.