Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

Similar documents
Refrigerant & Energy Regulations Update

Refrigerant and Energy Regulations Update

Understanding Applications for Alternative Refrigerants

Understanding Applications for Alternative Refrigerants

DOE and EPA Impacts to Commercial Refrigeration

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

How to Meet 2017/2020 Energy Regulations

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Making Sense of the Latest Rulemaking on Acceptable Refrigerants. E360 Webinar

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

REFRIGERANT CHANGEOVER

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

The Case for R-290 in U.S. Commercial Foodservice

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Honeywell Refrigerant Update

SOLSTICE L40X (R-455A)

Gary Parker Refrigerants Product Manager

Top Retailer Trends for Refrigeration, Controls and Facility Optimization. E360 Webinar March 6, 2018

10/4/2013. The Changing State of Refrigerants

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Low GWP Refrigerants for Air Conditioning Applications

Chillers for High Ambient Conditions: What Technologies and Fluids?

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

R-404A Alternative with Low Compressor Discharge Temperature

4/19/2013. The Changing State of Refrigerants

R-407A R-448A R-449A

Gary Parker Refrigerants Product Manager

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

The Current Path of Refrigerants

Refrigerant changeover guidelines

New Refrigerants Designation and Safety Classifications

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

AIRAH Victoria Refrigerants Update

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Honeywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40

Low GWP alternative refrigerants to R404A

Evaluation of HCFC Alternative Refrigerants

CO 2 transcritical FTE System Full Transcritical Efficiency

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Scroll Chillers Transition from HCFC-22 to HFCs

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

investment in R&D, the commitment to - name.

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Overview of New Refrigerants and Expected Market Trends

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

BRA FACT FINDER Number 19

Making equipment decisions

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Chapter 2. Alternatives to HCFCs and their Characteristics

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Refrigerant and Energy Regulations Update

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Meeting the Challenges of the EU HFC Phase-Down

Opteon XP10. Opteon XP10 Retrofit Guidelines to Replace R-134a. Refrigerant. Introduction. Important Safety Information

HCFC to HFO Blend Retrofit Guidelines Commercial Refrigeration Systems

Brazed Plate Heat Exchanger for CO Applications

Harold Ag & Mobile Products

Refrigerants. Refrigerants with the Future in Mind

DuPont ISCEON 9 Series Refrigerants

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

The natural solution for domestic refrigeration

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Automation and Energy Efficiency of Industrial Refrigeration Systems

New Refrigerants & Selecting Capital Equipment

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

Guidance for Stationary Refrigeration & Air-Conditioning

Framtidens köldmedier

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. Refrigerant. Introduction. Important Safety Information

Retrofitting Existing Systems

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Air Conditioning Repairs: Maintenance Required

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

HCFC to HFO Blend Retrofit Guidelines Commercial Refrigeration Systems

Refrigerants & Cooling in renovation buildings

Refrigerants for residential and commercial air conditioning applications

Hall 7A. Chillventa Specialist Forums 2018 Chillventa Fachforen NürnbergMesse, Arbeitstitel, Datum 1

Update on Refrigerant Blends

Natural Refrigerants.

Refrigerants. Retrofit Guideline. Commercial Refrigeration Systems Medium Temperature R-12, R-401A & R-409A to Solstice N13 (R-450A) & Genetron 134a

HCFC to HFO Blend Retrofit Guidelines Commercial Refrigeration Systems

APPLICATION & SERVICE GUIDE

Actions to Control Emission of HFCs in Japan

Transcription:

Refrigerants Management & Retrofits Mike Saunders & Randy Tebbe Emerson Climate Technologies

Agenda Refrigerant Landscape and Proposed Regulation Review Life Cycle Climate Performance Refrigerant Phase-Down Approach Retrofit Options Retrofit Guidelines Q & A

Alternatives for Refrigeration and AC Applications Pressure or Capacity CO 2 A1 Non Flammable A2L Mildly Flammable A3 Flammable B2L Toxic, Mildly Flam. Qualitative Chart Not to Scale R-410A Like R446A, R447A R32/HFO Blends 400-675 R32 R410A R404A & R407/22 Like NH 3 R290 <150 ~300 HDR110 DR3 R444B = L20 L40, DR7 R32/HFO Blends R448A = N40 R449A = DR33 N20 < 1500 R32/HFC/HFO Blends R22 R407A R407C R407F, R452A = XP44 R404A R507A (3922) R134a Like R123-Like (V.Low Pr.) HFO 1234yf HFO 1234ze DR2, N12, ARC 1 ~600 HFC/HFO Blends R450A = N13 R513A = XP10 R134a 0 500 1,000 1,500 2,000 GWP Level

EPA s Proposed Rule on Delisting HFCs by Application

North American Proposal for HFC Phase-Down GWP Weighted Cap (% of Baseline) 120% 100% 80% A5 Countries (Asia, etc.) 60% 40% Non-A5 Countries (U.S.) 20% 0% 2005 2010 2015 2020 2025 2030 2035 2040 2045 2050 2055 Year

Only a Holistic Evaluation Process Can Minimize Unintended Consequences Toxicity, Flammability Working Pressures Physical Properties Capacity, Energy (Annual/Peak Energy) Technology Changes Total Cost of Ownership Regulatory Requirements Life Cycle Climate Performance LCCP (GWP/TEWI)

LCCP Accounts for Energy and GWP LCCP (Life Cycle Climate Performance) Direct = Global + Warming Indirect Global Warming Holistic Approach: Safety Performance Environment Economics Refrigerant Leakage Leak during life End of life recovery leak Leak during production Energy Consumption Energy used during life Source of energy Embodied energy of all material used for manufacturing of fluid

Three System Architectures Offer Lowest LCCP* Choices in Supermarket Applications

Sample Refrigerant Phase-Down Analysis (Using Minimum LCCP Systems) 100-Store Chain Builds Two New Stores/Year Baseline: 80% R404A and 20% R22 in Centralized Systems System Architectures and Refrigerants Changes Retrofits: Four Refrigerant Retrofits/Year to R407A for Five Years (Eliminate R22) Then Four Retrofits to N40/Year for 20 Years (Reduce R404A) Remodels: Two Remodels/Year to Secondary N40 New Construction: Two Stores/Year to N40 Secondary or CO 2 Booster

LCCP and Weighted GWP

Weighted GWP Refrigerant Purchase Significant decrease in GWP weighted refrigerant purchase possible

Other Methods to Reduce Weighted GWP Refrigerant Purchase Reduce Leak Rates Convert Out of R404A Sooner Change to Architectures That Use Less Refrigerant or Natural Refrigerants Increase Use of Refrigerants Like R717, R744, R290 Monitor and Manage Refrigerant Use

Refrigerants Retrofit Options & Best Practices

Current Retrofit Options R12 R134a* R401A, R401B, R409A R502 R404A*, R507* R402A, R408A R22 R404A*, R407A/C/F R422A/D*, R438A, R427A, R507* *EPA proposed to delist in certain applications

Copeland-Approved Refrigerants and Lubricants / Bulletin 93-11

Med. Pres. Low Pres. Mid-Point Theoretical Refrigerant Comparison (0SC, 20F Compressor SH, 10 Evaporator SH) HFC HCFC

Theoretical Refrigerant Comparison Medium Pressure, Low Temp, -25/105/20SH/0SC/10ESH Medium Pressure, Medium Temp, 20/120/20SH/0SC/10ESH Low Pressure, Low Temp, -25/105/20SH/0SC/10ESH Low Pressure, Medium Temp, 20/120/20SH/0SC/10ESH

Guidelines for Refrigerant Conversions Guidelines available online at www.emersonclimate.com under the Online Product Information link

Refrigerants and Lubricants Frequently Asked Questions (FAQ) The Frequently Asked Questions bulletin is available at the Online Product Information (OPI) site under section 28 of the Application Engineering Bulletins.

Why Retrofit Refrigerants? Facilitates Compliance With Environmental Regulations Potential to Upgrade Compressor Technologies = Increased Efficiencies Enables Accelerated Transition Away From Ozone-depleting Refrigerants Provides Opportunity to Promote Environmental Leadership Provides Potential for Improved Compressor Reliability and Lifespan Avoid Premature Obsolescence of Equipment Avoids Costly Equipment Replacement / Improve Life Cycle Cost of Equipment Enables Continued Use of Existing Equipment With Minimal Downtime for Retrofit

Considerations Prior to Retrofit Are the Current Compressors and System Components Compatible With the New Refrigerants and Oils? Will Additional Cooling be Required? Will the System Require a Flush to Remove Excess Amounts of Mineral Oils When Converting to POE Oil? Are the Compressor Capacities With the New Refrigerant Similar to the Existing Refrigerant? Will the Sizing of the Thermal Expansion Valves Need to be Addressed or will the Valves Need to be Adjusted to Maintain Proper Super Heat? Remember, Many of the New Refrigerants Are Blends and May Have a Glide up to 8 F. Filter Driers Will Need to be Changed, and Ensure That the Drier Type and Design Are Compatible With the New Refrigerant and Oils. Will Seals and Gaskets Need to be Replaced. Pressure Switches and Controls Should be Verified and Adjusted for the New Refrigerant. Is there an Opportunity to Upgrade System Performance? Digital or Modulated Compressors, Floating Head Pressures Down, Reduce Number of Compressors on Rack? How Will You Manage System Downtime?

Eight Easy Steps for Refrigerant Retrofit *Always Follow Recommended Safety Guidelines and Procedures* 1) Establish a Performance Baseline With the Existing Refrigerant in the System. 2) Leak Check and Repair All Leaks Prior to Changing Refrigerants. 3) Remove Mineral Oil From Compressors (if applicable), and Recharge With the Appropriate Oil. Will the System Require a Flush to Remove Residual Oils? 4) Remove Existing Refrigerant / Weigh the Refrigerant Recovered From the System. 5) Change Filter Driers and Other Components, as Required. Verify Pressure Settings on Controls and Safeties. 6) Evacuate System Down to 250 Microns; Verify System Is Leak-Free. 7) Charge System With New Refrigerant Into the High Side of the System to About 80% of the Volume of the Refrigerant Initially Removed. Remember That With Blended Refrigerants, Only Charge in the Liquid State. 8) Start the System, Adjust Charge, Verify Super Heat Settings, Optimize System Operation. Label System With New Refrigerant and Oil Combination.

Med. Pres. Low Pres. Mid-Point Theoretical Refrigerant Comparison (0SC, 20F Compressor SH, 10 Evaporator SH) HFC HCFC

Future Retrofit and Alternative Options R134a R450A, R513A *HFO1234yf, *HFO1234ze Others? R404A R407A/C/F, R448A, R449A *R290, *R744 (CO 2 ), HFO Blends? R410A *R32 *HFO Blends??? *R290 and R744 (CO 2 ) are not applicable for retrofit, and many of the blends are considered mildly flammable.

Thank You! Questions? DISCLAIMER Although all statements and information contained herein are believed to be accurate and reliable, they are presented without guarantee or warranty of any kind, expressed or implied. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and the user assumes all risks and liability for use of the information and results obtained. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. The user should not assume that all toxicity data and safety measures are indicated herein or that other measures may not be required.