FREWIN STEAM SHOWER ENCLOSURE

Similar documents
ARLEY STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

Whirlpool Bathtub Model Number: MT618

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI80

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-670EX/E300-CX

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

SYSTEM BASIC WHIRLPOOLS

Spa Control System OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

TRANQUILITY ADVANCED HEATING SYSTEM

SK SERIES INSTALLATION INSTRUCTIONS 1

Owner s Manual for the Passport Series Rooms PS 44 With SaunaLogic Control

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

AQUAPEUTICS MONACO INSTALLATION MANUAL

NEOSAUNA SERENITY SAUNA INSTRUCTION MANUAL Read all instructions carefully before using this wooden sauna room SKUS: SAU-SER-4C-B, SAU-SER-4C-C

Installation and Operation Manual MG-304. Please read this manual carefully before use.

INSTALLATION AND OWNER'S MANUAL

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

ULT L IMAT A E SERIES SOLID-STA T T A E SYSTEM OPERAT A ION MANUAL 8600

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-540BX/B400-X. Important: Please record your serial number here

INFRARED SAUNA ROOM. Thank You for purchasing Our American Made Product! Proudly Made in the USA! PRECISION THERAPY 4 PERSON SAUNA USER MANUAL

ECO SPA & POOL OWNERS MANUAL & INSTALLATION GUIDE

Hallmark Rooms HM 55C and HM 66C Owner s Manual with SaunaLogic Control and Bluetooth Sound System

E2 Series Installation

6500/7500 SERIES OWNERS OPERATION GUIDE

NEPTUNE Steam Room Installation Instructions

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

Owner s Manual for the Passport Series Rooms PS 46 and PS 57 With Saunalogic Control

OWNERS OPERATION GUIDE

UNIVERSAL AIR SERIES SYSTEM OPERATION MANUAL

INSTALLATION/OPERATING INSTRUCTIONS. AQUEFIER POOL HEATERS Model TK125T

INSTALLATION AND OPERATING INSTRUCTIONS

Owner s Manual. Model PH050006

INSTALLATION AND OPERATING INSTRUCTIONS

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

4200/6200/9200 SERIES

NEXT SOLID-STATE SYSTEM. P u m p. * A u x. e f

INSTALLATION, OPERATION AND MAINTENANCE

6000 AIR SERIES SYSTEM OPERATION MANUAL A-AZ Rev.0 5/07

User manual Whirlpool

4100/6100/7100 SERIES OWNERS OPERATION GUIDE

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

POOL HEATER INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION AND OPERATING INSTRUCTIONS Page 1

SYSTEM INSTALLATION AND SERVICE AT AND 3T STEAMERS

Control Series Operation Instructions Page 1. "Digi VII"

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

Infrared Room Installation & Operation Instructions

Mini Mist Installation Instructions. Health. Relaxation. Exhilaration

4200/6200/9200 SERIES OWNERS OPERATION GUIDE

INSTALLATION AND USER MANUAL

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

Important Installation Guide & Operating Instruction

OWNER S MANUAL ONE-PERSON & TWO-PERSON SAUNAS WITH CERAMIC OR CARBON HEATERS

Destination Collection Whirlpool Bath Installation Instructions

ELLA SOAKING WALK IN BATHS OWNERS MANUAL. Representing these model numbers: L / R Elite Soaking L / R Royal Soaking

IMPORTANT INSTALLATION and OPERATING INSTRUCTIONS

Precedence Bath Whirlpools: K-1355-H1 K-1356-H1

Installation and user s manual Read carefully and keep it for later reference

INSTALLATION & INSTRUCTION MANUAL

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

AT and 3T STEAMBATH GENERATORS For Models 4kW thru 14kW With T100 Control (Includes Optional Warm Start)

Installation Manual for the Manual Control Aquassure Bathtub For Models:

INSTALLATION MANUAL FOR MODELS: SOVANNA, BREZZA, TERRACINA, VENADO

OPERATION & INSTALLATION MANUAL

ULTIMATE SERIES SOLID-STATE

DELUXE SERIES SOLID-STATE

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

Important Safety Instruction

MAJESTIC Steam Cabin Installation Instructions

Installation, Operation & Service Procedures

Bubble Massage Bath (Include Electronic Drain)

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

SCHWAN INSTALLATION GUIDE

BURWELL BIDET TOILET SEAT INSTALLATION

Installation Manual for M-G014 & M-G015

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Owner s Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

OWNER S MANUAL INSTALLATION GUIDE

Introduction. Spa Model: Power Pack Model: Serial #:

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

INSTALLER: Save these instructions. for owner. owner s + operator s. manual

COPPER FREESTANDING TUB

Personal Hydro-Massage System: 10-Jet Tower Model. Owner s Manual AB Kohler Co.

OWNER S MANUAL THREE-PERSON & FOUR-PERSON CORNER SAUNAS

Infrared sauna SUN S Pure Infra User Manual

Owners Manual. Pub. No. 601-D

Whirlpool Tub USER S MANUAL

Commercial Series Installation Instructions. Health. Relaxation. Exhilaration

MAXI-FLO STAINLESS STEEL AND TITANIUM HEAT EXCHANGER FOR SWIMMING POOLS & SPAS INSTALLATION AND MAINTENANCE MANUAL

JENTLE JET LAUNDRY SINK

ADAGIO IMPORTANT T01-E INSTALLATION INSTRUCTIONS CAST IRON WHIRLPOOL K-732T/K-732T-NR/K-732T-GR

OWNER S MANUAL FOUR-PERSON & SIX-PERSON SAUNAS

USER MANUAL

Installation Manual 2 PERSON STANDARD SAUNA 200S

Transcription:

FREWIN STEAM SHOWER ENCLOSURE INSTALLATION AND USER MANUAL CONTENTS Steam Shower Enclosure Installation...2 Technical Information...2 Plumbing Requirements...2 Assembly...3 Tools and Materials...3 Installation...3 Safety Information...12 Steam Cabin Technical Specifications...13 User Manual...13 LCD Display...13 Control Panel...13 Steam Generator Cleaning...18 Troubleshooting...19 1

STEAM SHOWER ENCLOSURE INSTALLATION Before you begin, read the following installation and care instructions. Observe all local plumbing, building, and electrical codes. Unpack and inspect the product for any shipping damages. If you find damages, do not install. Contact Customer Service at 1.866.855.2284. If you need assistance or have questions while installing your shower enclosure, contact Customer Service. We recommend that all plumbing and electrical rough-in work be completed by a professional prior to shower enclosure assembly. Signature Hardware accepts no liability for any damage to the enclosure, walls, floor, or for personal injury during installation. TECHNICAL INFORMATION 220 volt, 20 amp GFCI breaker Line 1, line 2 and ground (1 dedicated line for steam) The size of breakers and wire gages is determined by local, state, and national codes as interpreted by the installing electrician. PLUMBING REQUIREMENTS This unit is equipped with hot and cold braided water supplies with ½" NPT pipe threads. Install hot and cold shut off valves with ½" male NPT pipe threads to connect to water supplies. Tighten all connections prior to installation. We recommend preparing the drain location with the shower enclosure base on site. A drain pipe 2" in diameter is required, hose can stretch 6". 2

ASSEMBLY TOOLS AND MATERIALS: Level Screwdriver Silicone Sealant Caulking Gun Adjustable Wrench Drill Set Square Rubber Mallet INSTALLATION 1. Set the shower tray in place. Place a level on the tray and adjust the tray legs as necessary until completely straight. Each leg should be touching the floor. Adjustable Foot 2. Install the door frame by connecting the wall posts and top rail to the shower tray with the ST5 x 50 mm, and ST4 x 50 mm tapping screws. ST4 x 50 mm Tapping Screw ST4 x 50 mm Tapping Screw 3

3. Install the technical panel and control system. Attach the panel to the shower tray with the ST5 x 25 mm tapping screws. 4. Attach the right wall panel to the shower tray with the ST5 x 25 mm tapping screws. 4

5. Attach the left wall panel to the shower tray with the ST5 x 25 mm tapping screws. 6. Attach the back rest to the wall panel with the ST4 x 35 mm tapping screws. 5

7. Attach the fixed glass panel to the door frame. Attach the metal blocks to each side with the ST4 x 20 mm tapping screws. ST4 x 20 mm Tapping Screw 8. Attach the top cover to the shower frame with the assembly hardware. 8A. Acrylic Cover 6

8B. Wooden Cover 9. Connect the flexible water feed tubs and electrical wiring to the corresponding outlets.. 7

10. To install the sliding shower door, wedge the upper wheel into the upper track. Remove the cap from the lower wheel and loosen the set screw. Wedge the lower wheel into the lower track. Tighten the set screw and replace the cap. Adjust the wheels as necessary so that the door can open and close smoothly. 11. Attach the hand spray slide bar to the shower panel. 8

12. Attach the shower basket to the wall panel with the ST4 x 30 mm tappling screws. 13. Install the shower seat and grid. 9

14. Install the door handle. 15. Install the seal and magnetic strips according to the drawing specifications to prevent leakage. 10

16. Run a bead of silicone sealant around the glass at the base of the shower encloser. Allow sealant to dry for at least 24 hours before using your new steam shower 17. Install any decorative trim pieces. 11

18. Connect the water supply and electricity. Push the shower into place if necessary. Use a screwdriver and rubber mallet to push the seal strips inside the door frame flush against the wall. 19. Use a small screwdriver to adjust the door wheels to make sure that the gap between the door and seal strips is as narrow as possible and the door is sliding smoothly. 12

SAFETY INFORMATION When using this unit, basic safety precautions should always be followed. Children under the age of 16 should not be permitted to use the steam shower enclosure. Use this unit only for its intended purposes as described in this manual. Do not use any additional attachments not recommended by the manufacturer. Never drop or insert objects into openings in the steam shower enclosure. The unit must be connected to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). The appropriate GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the Test button. The GFCI should power off. Push the Reset button to restore the power. If the GFCI fails to operate in this matter, it is defective. If the GFCI fails to provide power to the shower enclosure and a ground current is flowing the user could potentially incur an electric shock. Do not use the shower enclosure and repairs performed by a qualified electrician before using. A green-colored terminal (or wire connector marked G, GR, or Ground ) is provided within the front column. To reduce the risk of electric shock, connect this terminal or connector to the grounding terminal of your electric service or supply panel with a connector equivalent in size to the circuit of the conductors supplying this equipment. To reduce the risk of injury: The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving. The steam head is hot. Do not touch the steam head and avoid the steam near the steam head. Prolonged use of the steam system can raise internal body temperature and impair your body's ability to regulate temperature (hyperthermia). Limit steam use to 10 15 minutes at a time until you are certain of your body s reaction. Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy. Pregnant or possibly pregnant women should consult a physician regarding correct exposure. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory problems, or diabetes should consult a physician before using the steam system. If using medication, consult a physician before using the steam system as some medication may induce drowsiness or affect heart rate, blood pressure and circulation. Hyperthermia warning: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6 F. The symptoms of hyperthermia include dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include: Failure to perceive heat Failure to recognize the need to exit the steam shower Unawareness of impending risk Fetal damage in pregnant women Physical inability to exit the steam shower Unconsciousness WARNING The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia 13

STEAM CABIN TECHNICAL SPECIFICATIONS Rated Power: 3.0 KW Rated Voltage: AC240V Rated Electric Current: 16A Frequency: 60 Hz Power Supply Location: Wall Water Supply: ½" NPT pipe thread, hot/cold water Water Supply Location: Wall Diameter of Drainage Pipe: 1-½" flex pipe Length of Drainage Pipe: 39" USER MANUAL LCD Display 1. Fahrenheit 2. Celsius 3. Temperature 4. Temperature Indicator 5. Timer Setting 6. FM Radio Function 7. FM Radio Volume 8. FM Radio Channel 9. Chromatherapy ON/OFF 10. Fan ON/OFF 11. Steam ON/OFF 12. Power ON Indicator 13. FM Radio Channel 14. MP3 ON/OFF 14

CONTROL PANEL Steam Cabin Control Panel Power ON/OFF Steam Temperature Setting Steam Timer Setting Fan ON/OFF Chromatherapy Steam ON/OFF MP3 Radio Volume/Channel Radio Settings + Adjustment - Adjustment Steam Cabin Control Parts 1. Steam Temperature Sensor 2. LCD Display 3. Control Panel 4. Water Diverter 5. Water Volume Adjustment 6. Water Temperature Adjustment 7. Back Massage Jet 8. Steam Outlet 9. Hand Shower Set 10. Steam Generator Cleaning Liquid Jet 15

CONTROL PANEL Power ON/OFF Push any button to light the display (Image 1). Push the Power button to turn the system on (Image 2) and off. When the power is turned off, the display and background light shuts off immediately while the drain valve for the steam generator remains running for one minute. Image 1 Steam Temperature Setting The default steam temperature setting is 113 degrees. To adjust the temperature, push the Steam Temperature Setting button (Image 3) until the desired temperature is reached. When the cabin temperature reaches 4 degrees above the set temperature, the steam generator automatically shuts off. When the cabin temperature reaches 4 degrees below the set temperature the steam generator automatically turns on. Image 2 Steam Timer Setting The default steam timer setting is 45 minutes. To adjust the timer setting, push the Steam Timer Setting button (Image 4) until the desired time is reached. The system automatically shuts off at the end of the specified time. Image 3 Image 4 16

CONTROL PANEL Chromatherapy The Chromatherapy button controls the color of the chromatherapy lights. The chromatherapy symbol on the LCD display flashes when the chromatherapy lights are turned on (Image 5). Press the Chromatherapy button to adjust the turn the lights on and off and to adjust the lights as desired. Image 5 Fan ON/OFF Image 6 The Fan button turns the ventilation fan on and off. When the fan is running, the fan symbol on the LCD display flashes. Hold the Fan button in for 3 seconds to switch the display from Celsius to Fahrenheit (Image 7-8). Image 7 Steam ON/OFF Push the Steam ON/OFF button to turn the steam function on (Image 9). When the steam function is on the steam ON/OFF symbol flashes. The steam function is automatically turned off when the cabin temperature reaches 4 degrees higher than the set temperature and on when the temperature drops to 4 degrees below the set temperature. Image 8 Image 9 17

CONTROL PANEL MP3 Press the MP3 button to select the MP3 function. Adjust the channel to match the channel set on the MP3 emitter. Hold the MP3 button in for 3 seconds to set the channel and volume. Image 10 FM Radio ON/OFF Push the FM Radio ON/OFF button to turn the radio function on. When the radio is on the FM Radio ON/OFF symbol flashes. The channel will default to that last selected. Image 11 Volume/Channel Push the Volume/Channel button with the radio on (Image 12) to adjust the volume. Push the buttons to make adjustments as necessary. To change the channel, press the button twice when the radio is on (Image 13). Push the buttons to scan. Image 12 Image 13 18

CONTROL PANEL Radio Settings Selecting and saving preset radio stations: Turn the radio on. Push the Radio Settings button twice to display the preset numbers 1-8 (Image 14). Scan to the desired station and hold the Radio Settings button until the appropriate preset number is displayed. Finding a preset station: Image 14 Turn the radio on. Push the Radio Settings button to scan through the preset stations. STEAM GENERATOR CLEANING To clean the steam generator, remove the cover from the cleaning liquid inlet. Input 1L of mild detergent. Turn the steam function on to fill the generator with water. Before steam is released, turn the steam function off. Do not shut off the control system, the system will drain the dirty water automatically after 60 minutes. Repeat these steps to clean the steam generator every 3 months. 19

TROUBLESHOOTING If the touch panel is not functioning properly: Check the connection from the control panel to the power box. If the control panel and power box are properly connected and problems persist it may be necessary to replace the panel or box. If the steam function is ON but no steam is being released into the cabin: Check to ensure the water supply valve has not been shut off. Turn the water supply valve on if necessary. Remove the scale on the water level sensor and clean with warm water and a mild detergent. Replace the scale if it appears to be broken. Make sure that the temperature setting is not lower than the room temperature. Reset the temperature if necessary. Replace the thermal switch inside the heater. If all parts appear to be clean and in working order and problems persist it may be necessary to replace the heater. If water does not stop being added to the steam generator: Replace the water inlet valve. Remove the scale on the water level sensor and clean with warm water and a mild detergent. If problems persist it may be necessary to replace the scale. If the unit will not turn ON: Replace the heater or thermal switch. If water is leaking from the valve: Replace the valve seal. If the water flow volume is low: Impurities in the water supply can clog the filter resulting in low water flow. To remove clogs, remove the filter and rise with warm water. 20