LG Electronics AE Company, Commercial Air Conditioning

Similar documents
LG Electronics AE Company, Commercial Air Conditioning

Eco Compact Series GAS HEAT PUMP

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Air to water Heat Pump System

Air Conditioning System

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

NATURAL HEATING MACHINE

Water cooled VRV IV W-series

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Do you want a versatile solution

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Inverter Hot Water Heat Pumps

Air to water Heat Pump System

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

LG VRF Systems. Air Conditioning Technologies

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

VRV IV heat recovery Best efficiency and comfort solution

VRV The total solution. Integrated Climate Control

Modular Air Cooled Scroll Chillers

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

SWIMMING POOL HEAT PUMPS

WHY A MHI HEAT PUMP?

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Integrated Heat Pump Water Heater

Air to Water Heat Pump Utilising Natural Refrigerant C02

Multi Inverter Air Conditioning Condensing Units - Summary

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

DAIKIN Modular Inverter Air Cooled Chiller

Single Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It

PRODUCT GUIDE

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

VRF Series. The most advanced commercial air conditioning system

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Water and ground source heat pumps 61WG kw. Heating

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Heat Pump Water Heater Commercial Leaflet 2012

Saving energy comes naturally to us.

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

recooler HP EQKR HEAT PUMP

Integrated VarIable refrigerant flow ahu/pau (r410a)

Chillers. Technical Data. EWYD-BZ 250~580 kw

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Daikin Altherma hybrid heat pump. The natural combination

50A KP 70A KP 90A KP 120A KP 150A KP 210A

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

Variable Refrigerant Flow

HITACHI PRODUCT NEWS. Summary

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Samsung Free Joint Multi Air Conditioning System

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Advance Split

PAC BT LOW TEMPERATURE HEAT PUMP

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

ELECTRICAL QUANTITY WEIGHT (LB)

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

Technology that works fast. Inverter Ducted Systems

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Technology that works fast. Inverter Ducted Systems

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

QUANTUM. Reliable solar hot water, whenever you want it

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C


AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

VRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular

Product Line Introduction. Karl Zhang Technical support engineer

Hot water supply. Indoor unit. Domestic hot water tank. Take thermal energy from atmosphere. Outdoor unit

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Vision Air Conditioning Range Condenser-less Air Conditioner

THE CHEAPEST WAY TO HEAT YOUR WATER

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Samsung Air Conditioning

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Submitted to Reference Approval Construction Unit Designation Schedule #

Samsung System Air Conditioner Eco Heating System

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

Air Conditioner SVC MANUAL(Exploded View)

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

Technology that works fast. Inverter Ducted Systems

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Transcription:

www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu, Yeouido P.O.Box 335 Seoul, 15721, Korea. Phone : +82237777586 www.lg.com www.lgeaircon.com Copyright 212 LG Electronics. All rights reserved. Distributed by LG Hydro Kit is total HVAC solution that is applied to water Heating, Domestic hot water supply as well as AirConditioning by connecting various heat pump outdoor unit.

Ecofriendly, highefficiency, energy saving, recovery based heating system Control more than just the temperature with our EcoFriendly Heat Pump. The Hydro Kit LG new Hydro Kit is a highefficiency total solution for floor heating and cooling and hot water supply. This energy saving heating system takes advantage of ambient air temperatures and residual heat from other areas of the building through airtowater heat exchange to produce domestic hot water for various applications. Ideal for providing hot water supply to commercial buildings in an energyefficient way, the Hydro Kit has minimized energy costs as compared to a boiler, while achieving a considerable reduction of CO2 emissions. Heating Domestic Supply InFloor Heating with InFloor Cooling with Cold Water Cold Water Cooling LG presents a solution that will satisfy your building s water heating needs, raising temperatures without adding to the bottom line. Ecofriendly with lower CO 2 emissions Compared to fossilfuel boiler systems, the Hydro Kit emits far less CO2. Providing sustainable operation for space heating and domestic hot water using ambient air, a renewable energy source, the Hydro Kit has achieved a considerable reduction of CO2 emissions using as little as 3% of that of a gas boiler. Thanks to the refrigerant used, () that has a Zero Ozone Depleting Potential (ODP), LG contributes to ozone protection. Energy savings thanks to a highefficiency compressor Because our systems extract thermal energy from the ambient air or residual heat from cooling operations, they are far more energy efficient than comparable boiler systems. The Hydro Kit advanced heat pump technology and highefficiency compressor can optimize operations according to heating loads to increase reliability, reduce noise levels and save energy while achieving flow temperatures up to 8ºC. The heat pump works much more efficiently and conserves more energy than a traditional heating system based on fossil fuels or electricity to reduce running costs and carbon emissions. It also avoids the inconvenience of installing gas boilers and meters as well as their related maintenance costs, all while attaining a significantly higher Coefficient of Performance (COP) when compared to boiler. [A heat pump s efficiency is measured in COP (Coefficient of Performance) for heating and EER (Energy efficiency ratio) for cooling.] LG MULTI V Hydoro Kit achives COP of up to 4.2(with MULTI V Water II), meaning one unit of consumed energy yields 4 units of heated or cooled energy. Recovery heating system how to grab hot water from the air The heat pump contained in the Hydro Kit works by extracting heat from ambient air and upgrading it to heat a building or provide domestic hot water which means that heat can be recovered and reused. This ensures less energy wastage. The heat recovery aspect of the Hydro Kit goes beyond to make use of wasted heat, extracted from other areas of the building requiring cooling. This allows the heat gathered from within a building s infrastructure to be collected and stored, ready for use as hot water or heating. Taking full advantage of this, the Hydro Kit recovers and reuses the heat, which ensuresless energy wastage resulting in greater energy efficiency, reduced running costs and a reduction in carbon emissions. Tapping into renewable energy sources, that s LG smart! Hydro Kit for Multi V A complete HVAC solution Combining efficiency and total comfort, the addition of an LG Hydro Kit to an LG Multi V system provides a total heating and cooling solution for a range of applications. Providing hot water supply to these applications is adding a booster unit to the existing air conditioning systems. The easy to install compact modular structure becomes an allinone global solution for heating, cooling, ventilation and sanitary hot water. By linking the LG Hydro Kit and LG Multi V, excess heat can be successfully reused for the generation and storage of domestic hot water as well as for heating, via underfloor circuits, fan coil units and radiators. The energy savings appear any time during the year when a room needs to be cooled down. Typically, during summer, the system will use heat extracted from the indoor units to produce sanitary hot water. LG environmentally minded for a comfortable environment.

What is Hydro Kit? Hydro Kit Benefits Hydro Kit is Ecofriendly and Highefficient. This total HVAC solution is available to Airconditioning, floor heating, radiators and sanitary hot water supply. All these functions, utilizing a variety of Multi V outdoor unit, minimize energy costs and CO 2 emissions compared to boiler system. Refrigerant Cooling / Heating Provides sanitary hot water supply and floor heating efficiently through lower energy costs compared to a boiler and contribute to green energy enviornment through reduction of CO 2 emissions. Easy Installation Unnecessary to duct for emitting gas, easy to install as compact and modular structure Boiler system Hydro Kit cooling cooling Sanitary Hot water Floor Heating Supply Floor Heating Supply MULTI V Outdoor Unit Heating by Hot water Oil Tank Boiler Cooling by Cold water Ecofriendly Green Energy Solution Variety of Outdoor Combination * Only for medium temp. Ecofriendly system Green energy solution through reduction of CO 2 emmisions (%) 12 1 6 CO 2 emissions 76% A variety of heat pump includes Aircooled, Watercooled and GeoThermal source and outdoor unit can be combined according to installation condition of building or envirenment temperature. 4 2 3% Conventional System Oil Boiler Gas boiler AirCooled Heat Pump HighEfficiecy Products Provide Highefficiecy, hot water solution by connection of variable VRF. WaterCooled Heat Pump 2.2kW Aircooled COP = 3.1 Hot water supply capability of Aircooled HP 3.1kW Electric Energy 1kW WaterCooled COP = 4.2 3.2kW Hot water supply capability of Geothermal HP 4.2kW

Economics High Temperature of Hydro Kit High economic efficiency through lower energy costs compared to hot water system of boiler High Temperature of Hydro Kit Concept High Economical Efficiency through Energy Saving Possible to install with equivalent level of an initial cost as the boiler system and minimize energy costs by lowpriced operating costs. Dual inverter cascade cycle technical Max 55% capacity improvement bettter than medium temperature of Hydro Kit Max 2% heating operating cost reduction better than medium temperature of Hydro Kit 25, 2, 15, 1, 5, Initial Costs 9% 95% O il B o il e r 25, 2, 15, 1, 5, Annual Operating Cost 171% 229% O il B o il e r 1 st Proposal Multi V Hydro Kit (Air Conditioning + Hot water supply + Floor Heating) 2 nd Proposal Multi V Airconditioning + Gas Boiler (Hot water supply + Floor Heating) 3 rd Proposal Multi V Airconditioning + Oil Boiler (Hot water supply + Floor Heating) High volume of Domestic hot water Compared to lower temperature, storing high temperature water in a sanitary tank increases a lot the quantity of mixed water available for the user. Cascade to R134a inverter compressor technology 5, 4, 3, 2, 1, LCC 1 2 3 4 5 6 7 8 9 1 (Year) *Condition of analysis : Except for common items includes Sanitary tank, floor heating coil expense *Economic efficiecy is changeable according to design concept, detailed specificaiton of system O i l B o i l e r Analysis Conditions Building Type : Dormitory, flats Cooling / Floor Heating / Sanitary Hot water for 1 years Cooling : Multi V Indoor unit Floor Heating : Hydro kit (1ea) Sanitary Hot water : Hydro kit (2ea), sanitary Hot water tanks Electricity cost : Average cost in EU Gas cost : Average cost in EU Oil cost : Average cost in EU High Temperature of Hydro Kit Cycle Diagram AIR Leaving water temperature up to 8ºC Outdoor Unit High Temperature Hydro Kit Heating by AirRefrigerant Refrigerant Refrigerant Refrigerant Water Energy Saving through Heat Recovery 5ºC 8ºC Energy costs can be saved by using wasted heat source from indoor to outdoor at cooling. High Temperature Technical Pressure Water Refrigerant Cooling Two Stage HR Unit Heat Absorption R134A Single Stage AIR Enthalpy Heat Emission Indoor Cooling Sanitary Tank

Application Quality Control & Specification Various Application Applicable to a variety of facilities includes hospitals, residences and resorts that need water heating and Domestic hot water supply. LG provides a perfect management from design to service & maintenance. Quality Control Design Installation Commissioning Office University / School Hospital / Clinic Design Specification Support *Air conditioning *Ventilation *Controller Training *LG provide training for installers *Systemized trainning regarding theory and practice SVC& 유지보수 SVC & Maintenance Start Run Commissioning Support *Design *Installation Shopping Mall / Restaurant Hotel / Resort Factory Facilities Service Training *SVC/ maintenance Check Installation Conditions and Products Check Operating Conditions and Capability *LGMV Program Hotel Constant cooling & heating are possible at the same time during summer time provide hot water for bathroom using waste heat energy from indoor cooling by indoor unit. Specification Type Hydro Kit () Hydro Kit () Model ARNH1GK2A2 ARNH8GK3A2 Office In the office while cooling HR unit makes sanitary tank to be warmed using waste energy, hot water can be supplied at all times. Power Supply Ø / V / Hz Capacity (Rated) Cooling kw Capacity (Rated) Heating kw Input (Rated) Cooling kw heating kw Casing Dimensions Body w x H x D mm inch Net Weight Body kg (lbs) Heat Exchanger Refrigerant to Water Type R rated Water Flow L/min H head Loss kpa R refrigerant to Refrigerant Type Compressor Type Piping Connections Water Side inlet inch O outlet inch R refrigerant Side Liquid mm(inch) G gas mm(inch) Drain Piping Connection inch Sound Press Level Cooling db(a) H heating db(a) Power Supply Cable N no. x mm 2 Communication cable no. x mm 2 Refrigerant Refrigerant to Refrigerant Refrigerant name Control R refrigerant to Water Refrigerant name Precharged Amount kg (lbs) Control 1 / 2224 / 5 29. 32..1.1 Painted Steel Plate 52 x 631 x 33 215/32 x 2427/32 x 13 35. (77.2) 46. 25. Ø 9.52(3/8) Ø 22.2(7/8) 26 26 3C x CV2.5 2C x CVVSB 1.~1.5 EEV 1 / 2224 / 5 25. 5. Painted Steel Plate 52 x 1,8 x 33 215/32 x 4217/32 x 13 94. (27.2) 36. 2. Twin Rotary Inverter Ø 9.52(3/8) Ø 19.5(3/4) 43 3C x CV4. 2C x CVVSB 1.~1.5 Electronic Expansion Valve R134a 3. (6.6) EEV *Notes Capacities are based on the following conditions: 1. Cooling Temperature : Indoor 27 C(8.6 F) DB / 19 C(66.2 F) WB, Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB, Water Inlet 23 C(73.4 F) / Outlet 18 C(64.4 F) 2. Heating Temperature : Indoor 2 C(68 F) DB / 15 C(59 F) WB, Outdoor 7 C(44.6 F) DB / 6 C(42.8 F) WB, * Water Inlet 3 C(86 F) / Outlet 35 C(95 F), ** Water Inlet 55 C(131 F) / Outlet 65 C(149 F) 3. Piping Length : Interconnected Pipe Length = 7.5m 4. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. * **