MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water Unique Solutions for All-Indoor HVAC Projects
MiniCool United CoolAir Breaks the 75 Foot Barrier The MiniCool evaporators can be split To various lengths based on factory recommendations. That s over three times longer than conventional ductless systems. Components can even be located on different levels. The condensing unit used with the MiniCool evaporators feature a centrifugal blower making it ideal for indoor APPLICATIONS Commercial Offices Conference Rooms Reception Areas Lunch Rooms Retail Space Schools Churches Restaurants Healthcare/Hospitals Residential Condominiums/Apartments Tenant Fit Out Rehab Retrofit Single, Dual or Triple Condensing Section Configurations Split ductless System 2 installation. Unlike typical ductless A/C systems that require an outside condensing section, waste heat is conveniently ducted to any outside wall. You can even specify a water-cooled condensing section to eliminate the need for ducting altogether. The combination long refrigerant run and ducting option provide unlimited flexibility.
Total Installed Cost Advantages Avoid Requirements that Lead to Extra Expense Expensive Equipment, Rigging or Permits Equipment can be shipped in sections Fits easily through standard doors, hallways, and into elevators Minimizes the need for crane rentals, rigging crews, and municipal permits Roofcurbs or Roof Penetration Eliminates expensive curb equipment cost Reduces installation labor Eliminates possible roof water damage Field Piping, Brazing, Evacuation or Charging Factory charged and utilizes Resealable Refrigerant Fittings Reduces installation labor Faster installation and commissioning Excessive Downtime when Replacing Old Systems Sectional shipments accelerate installation Can be installed off-hours and on weekends Shipment can be made to coincide with installation schedules Equipment Damage Due to Weather All equipment is installed indoors Avoids premature replacement costs due to weather wear and/or damage Eliminates downtime due to severe storms Possibility of Theft or Vandalism Eliminates expensive repairs and replacements due to theft and vandalism Enhances building security by eliminating interruption to service Eliminates extra cost for cages and special alarms Field Testing of Installed Product Minimizes field testing as units are functionally tested prior to shipment Reduces labor and speeds installation Assures trouble-free start-ups Outdoor Servicing of Product Outdoor/premium service expense in extreme weather completely eliminated Improves reliability Eliminates roof safety issues Architectural Damage to Building Eliminates expenses for code approvals Requires no rigging holes through building walls Minimizes any type of building alteration Compromise in Performance With Built-to- Order Design Units are built to exact requirements Avoids purchase of excess capacity from standard product offerings Extensive list of configurations and options Major Ductwork or Electrical Modifications Units ordered to closely match existing duct and utility locations Major installation, labor and time savings Exterior Condensing System Eliminates rooftop and pad installation space and cost Water-Cooled and Chilled Water configurations eliminate unsightly equipment outdoors Resealable Refrigerant Fittings Most models feature Resealable Refrigerant Fittings. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost advantage. 3
MiniCool Enjoy All the Benefits of a DUCTED Condensing Unit with a Choice of Ductless Evaporators Ductless Evaporators MiniWall 1 3 Ton Capacity Cooling United CoolAir Corporation is changing the way you think about ductless air conditioning systems. No longer are you restricted to short refrigeration runs and outdoor condensing units. The MiniCool is the first ductless evaporator commercial split A/C system with an indoor condensing unit that can split To various lengths based on factory recommendations. The MiniCool system consists of a single or multi-circuit, air cooled or water-cooled condensing section and a variety of fan coil options, including ductless and ducted. The condensing unit can have up to three individual refrigerant circuits, each with up to three tons of cooling, for a total of nine tons. You can vary the number of refrigeration circuits from one to three and the size of each refrigeration circuit from one to three tons. Condensing unit options include air-cooled or water-cooled allowing you to effectively cool spaces you thought were impossible! CoolSpot 1 3 Ton Capacity Cooling Electric Heat Computer Room Applications Other Available Evaporators United CoolAir offers the widest choice of fan coil options with wall and in-ceiling ductless units, as well as ceiling-mounted ducted and compact vertical floor models. All are designed for quiet operation and can use standard room thermostats for individual control. C Seires Ducted System VertiCool Freeblow System 4
MiniCool Select the Air Handler Best Suited for Your Application MiniWall The MiniWall evaporator adapts to any room configuration using minimal wall space. The soft tones and nicely styled exterior of the MiniWall blends naturally with any decor, and the unit has adjustable louvers for precise airflow. A standard wall thermostat controls temperature along with a unit-mounted fan speed adjustment C-Series Evaporator The versatile C-Series air handler is designed for applications requiring a ducted supply air. This compact unit installs quickly in above-ceiling locations, with easily removable panels for component accessibility. The C-Series evaporator includes a corrosion-free stainless steel drain pan, oversized coil for low-pressure operation and adjustable static pressure. CoolSpot The ceiling-mounted Coo/Spot air handler provides both cooling and a heating/cooling option replacing a standard T-bar framework acoustical tile. The return grill includes an integral filter and three-directional supply air grill for even air distribution. The CoolSpot has a direct drive, double inlet blower, and both the sight glass and fan speed switch are room-side accessible. OPTIONS Internal Hot Gas Bypass Electric Heat (CoolSpot and C-Series) Low Ambient Dampers Scroll Compressors Flooded Condenser Remote Humidification Kit Oil Separator Compressor Short Cycle Timer Quench Valve Suction Line Accumulator Outdoor Modification Kit Liquid Receiver 5
MiniCool MiniWall Ductless Air Conditioning System Wall-Mounted Fan Coil Unit 1 3 Tons split-able To various lengths based on factory recommendations. Used with Air or Water-Cooled Indoor Condensing Unit, MiniWall High Wall fan coils provide installation flexibility and offer an effective zone cooling system where ducted systems are impractical or too costly to install. The fan coils install easily on most interior walls. Matched to United CoolAir s single or multi-split indoor condensing unit. The MiniWall high-wall fan coil is ideal for commercial offices, conference rooms, retail shops, churches, restaurants, renovations, additions and motels. Mini- Wall fan coils are available for cooling-only operation and are a major component to the MiniCool commercial air conditioning system. *Equivalent feet, contact factory Also available for outdoor applications FEATURES Ultra-quiet operation Thermal expansion valve Cooling-only operation Attractive durable design Hand-held control (standard) Wall-mount control (optional) Permanent cleanable filters Mounting plate provided for easy installation to most indoor walls Units are available with 208/230-1-60 power supply Low Ambient To Power supply Condensate Drain Line Unit Disconnect 4" 4" 4" Clearance Required for Indoor Units 4" Control Wiring (Optional) MiniCool Indoor Condensing Unit* (Air-or Water-Cooled) From One to Three Individual Refrigerant Circuits 28" Minimum Clearance to Floor or Furniture Required for Evaporator Units 28" Split-able up to 200 Feet * Can also be modified for outdoor use 6
MiniCool Basic Model Designation EXAMPLE: ED a 2 b G c 1 d AS e T f A g MiniWall High Fan Coil Unit (DX) a. ED High Wall Fan Coil Section (Cooling Only) (DX) b. 1, 1.5, 2, 2.5, 3 Normal Cooling Capacity c. G Common to all d. 1 Voltage 1 208-230V, 1 PH e. AS Single Circuit f. T Traditional Cabinet g. A R-410a Refrigerant EXAMPLE: EDCW a 2 b G c 1 d AS e T f MiniWall High Fan Coil Unit (Chilled Water) a. EDCW High Wall Fan Coil Section (Cooling Only) (Chilled Water) b. 0.75, 1, 1.5, 2, 3 Normal Cooling Capacity c. G Common to all d. 1 Voltage 1 208-230V, 1 PH e. AS Single Circuit f. T Traditional Cabinet 7
Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons Authorized Distributor: C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order Alpha Aire 100 500 CFM OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice. 50.1-SB (1017)