Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Similar documents
FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Performance of a MEMS Heat Exchanger for a Cryosurgical Probe

Heat Exchanger Joule-Thomson Transient Cryogenic Refrigeration. Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE

Remote Helium Cooling Loops for Laboratory Applications

Nova Movie: Absolute Zero

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

10 K Airborne Cryocooler and

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance Investigation of Joule Thomson Refrigeration System with Environment Friendly Refrigerant Mixtures

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Performance of CO2 Cycles with a Two-Stage Compressor

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Adsorption refrigeration system using waste heat

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Global Journal of Engineering Science and Research Management

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Performance of an Improved Household Refrigerator/Freezer

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

A 2 K Active Magnetic Regenerative Refrigeration System for Remote Cooling

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 = 90 F. compressor. condenser. 5 evaporator 1. evap

Development of the Micro Capillary Pumped Loop for Electronic Cooling

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Enhancement of COP in Vapour Compression Refrigeration System

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

Refrigerator and Heat Pump Objectives

Submerged Pumps and Expanders with Magnetic Coupling for Hazardous Applications

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Pocket Dilution Cooler

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Design and Fabrication of a Cool Box for Passenger Car using Automotive Air-conditioning System

Energy and Exergy Analysis of an Ejector-Absorption Refrigeration Cycle with Using NH3-H2O as the Working Fluids

Purdue e-pubs. Purdue University

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Compression of Fins pipe and simple Heat pipe Using CFD

Thermal Performance of a Loop Thermosyphon

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Chapter 11 REFRIGERATION CYCLES

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Steam Power Cycles Part II

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Modelling the Performance of a Diffusion Absorption Refrigeration System

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Design and Development of Water Cooled Condenser for Domestic Refrigerator

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

*Corresponding author;

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

An Optimized Plate Fin Type Heat Exchanger

Chapter 11 REFRIGERATION CYCLES

Chapter 9. Refrigeration and Liquefaction

An ultra-low vibration cryocooling kit based on a miniature Rotary Compressor

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Transcription:

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators Yong-Ju Hong, Seong-Je Park Korea Institute of Machinery & Materials Daejeon, 35-6, Korea Young-Don Choi Department of Mechanical Engineering, Korea University Seoul, 136-71, Korea ABSTRACT A typical Joule-Thomson (J-T) refrigerator consists of a recuperative heat exchanger, a gas expansion nozzle, a mandrel, and a compressed gas storage bottle. The thermodynamic performance of a J-T refrigerator depends highly on the hydraulic and heat transfer characteristics of the recuperative heat exchanger. The typical recuperative heat exchanger of a J-T refrigerator has a double helical tube and fin configuration, but other heat exchanger configurations may be used, including the two-flow type helical tube and fins configuration, the twostage heat exchanger configuration, a double helically wound tube circuit arranged in a spiral channel, etc. In this study, the performance of J-T refrigerators with single and two-flow type recuperative heat exchangers was investigated. The effectiveness-ntu approach was adopted to predict the thermodynamic behaviors of the heat exchangers for the J-T refrigerators. The results show the effect of the operating conditions on the performance of the heat exchanger and refrigerator for three types of heat exchangers. The influences of mass flow rate and supply pressure on the effectiveness of the heat exchanger and the refrigeration power are discussed in detail. INTRODUCTION Miniature Joule-Thomson (J-T) refrigerators have been widely used for rapid cooling of infrared detectors, probes for cryosurgery, thermal cameras, missile homing heads, and guidance systems. This wide utilization is due to their special features of simple configuration, compact structure, and rapid cool-down. Nitrogen (NBP 77.35K) and argon gas (NBP 87.3K) are typically used as the cryogen due to their availability, low cost, and their ability to achieve a relatively low cryogenic temperature. The cool-down time, temperature at the cold end, running time, and gas consumption are the important indicators of the performance of a miniature Joule-Thomson refrigerator. 455

456 J-T AND SORPTION CRYOCOOLER DEVELOPMENTS Figure 1. Schematic diagram of a Joule-Thomson refrigerator A typical Joule-Thomson refrigerator consists of a recuperative heat exchanger, a gas expansion nozzle, a mandrel, and a compressed gas storage bottle as shown in Figure 1. The cooling power of the J-T refrigerator is generated by the isenthalpic expansion of the high pressure gas through a throttling process. The J-T cooling effect can be amplified by using the expanded gas to cool the incoming gas within a recuperative heat exchanger. The thermodynamic performance of a J-T refrigerator depends highly on the hydraulic and heat transfer characteristics of the recuperative heat exchanger. The typical recuperative heat exchanger of a J-T refrigerator has a double helical tube and fin configuration, but other heat exchanger configurations may be used, including the two-flow type helical tube and fins configuration, the two-stage heat exchanger configuration, a double helically wound tube circuit arranged in a spiral channel, etc. 1 Ng et al. 2 and Xue et al. 3 have conducted steady state simulations of the Hampson-type heat exchanger with argon gas. The performance of the Hampson-type heat exchanger was evaluated for its effectiveness, flow, and heat conduction losses, as well as its liquefied yield fraction. Chua et al. 4 developed an analytical model of the Hampson-type cryocooler with argon gas, and the steady state governing equations were solved numerically. Hong et al. 5 adopted the effectiveness-ntu approach to predict the thermodynamic behavior of the heat exchanger of a J-T refrigerator for different pressures and mass flow rates of nitrogen and argon gas. In this study, the performance of J-T refrigerators with single and two-flow type recuperative heat exchangers was investigated. The effectiveness-ntu approach was adopted to predict the thermodynamic behavior of the heat exchangers. RECUPERATIVE HEAT EXCHANGER Finned tube heat exchangers have been the most common way of constructing J-T refrigerators. The heat exchanger is formed by wrapping the finned tube around an inner sheath tube (mandrel). A polyester thread is co-wound above the finned tube to provide spacing and to direct flow to the finned tube. The number of wraps determines the overall length of the heat exchanger. The configuration of the external finned side primarily determines the effectiveness of the counter-flow heat exchanger. The pressure drop across the length of the expanded gas side affects the temperature at the nozzle. Increasing the pressure drop increases the saturation pressure and the temperature of the nitrogen gas. The heat exchanger should be designed to minimize the pressure drop of the expanded gas, thus insuring a refrigeration temperature of 8 K or less. Considerations that influence the pressure drop of the low pressure gas are the flow area, the mass flow rate, thermodynamic properties of the working fluid, and the overall length of the heat exchanger. 6

EFFECT OF HX CONFIGURATION ON J-T PERFORMANCE 457 (a) Type (I) (b) Type (II) (c) Type (III) Figure 2. Configuration of heat exchangers. A heat exchanger can be built with two passages for the high pressure gas and a common passage for low pressure gas. Several layers of tubes may be used to provide multiple parallel paths for the high pressure gas, thereby reducing the pressure drop. In this study, the performance of J-T refrigerators with single and two-flow type recuperative heat exchangers was investigated. Configurations of the heat exchanger are shown in Figure 2. Type (I) has a conventional double helical tube and fin configuration. Types (II) and (III) have two passages for the high pressure gas, and the surface area of the finned tubes is double that of the type (I) with the same number of wraps. The overall length of the heat exchanger of the type (III) is double that of the type (I) and (II) with the same number of wraps. The geometric dimensions of the recuperative heat exchangers are listed in Table 1. The analysis was carried out for nitrogen gas with an inlet pressure of 1 ~ 5 MPa and at 295 K. Table 1. Dimensions of a recuperative heat exchanger Parameters Inner diameter of tube Outer diameter of tube Pitch of tube Fin (height/thickness) Pitch of fin Value.3 mm.5 mm 1.1 mm.2 /.8 mm.3 mm

458 J-T AND SORPTION CRYOCOOLER DEVELOPMENTS 4. 12 Refrigeration (W) 3.5 N increases 3. 2.5 2. 1.5 1..5. 1 15 2 25 3 35 4 45 5 (a) mass flow rate :.14 g/s Refrigeration (W) N increases 1 8 6 4 2 Figure 3. Refrigeration of the type (I) N=17 1 15 2 25 3 35 4 45 5 (b) mass flow rate :.625 g/s 5 8 4 3 2 1 N increases 7 6 5 4 3 2 1 N increases 1 15 2 25 3 35 4 45 5 (a) mass flow rate :.14 g/s 1 15 2 25 3 35 4 45 5 (b) mass flow rate :.625 g/s Figure 4. Pressure drop of the low pressure gas for the type (I) RESULTS AND DISCUSSION Liquefied yield is an important parameter in the evaluation of the performance of a J-T refrigerator, as it affects the effectiveness of the heat exchanger. Effectiveness of the heat exchanger depends on the mass flow rate, heat transfer area, heat transfer characteristics, and thermodynamic properties of the gas. Typically, increases of the mass flow results in the decreases of the effectiveness of the heat exchanger. Figure 3 present the effect of the number of wraps (N) and pressure of the gas on the refrigeration. With an increase in the number of wraps, the overall length of the heat exchanger increases and the refrigeration increases. The refrigeration increases as the supply pressure of the gas increases up to 4 MPa. The refrigerator with the larger mass flow rate has the higher refrigeration. But the minimum number of wraps to get the refrigeration increases as the mass flow rate increases. The refrigeration is not linearly proportional to the mass flow rate due to changes in the effectiveness of the heat exchanger. The performance of a J-T refrigerator depends on the pressure drop of the gas. In the passage for the high pressure gas, a relatively small pressure drop occurs, and the effects of the pressure drop on the performance are small. Figure 4 shows the effects of the number of wraps and pressure of the supply gas on the pressure drop of the low-pressure gas.

EFFECT OF HX CONFIGURATION ON J-T PERFORMANCE 459 The results show that the pressure drop increases as the number of wraps increases. The refrigerator with the larger mass flow rate has the higher pressure drop. The supply pressure of the gas does not affect the pressure drop. In the case of a low pressure gas supply, a large pressure drop can occur due to a change of the physical properties of the gas. Figure 5 shows the effects of the mass flow rate on the pressure drop of the low pressure gas and the temperature of the gas after the J-T expansion for a gas that is supplied at a fixed pressure of 4 MPa and 295 K. As shown, the heat exchanger pressure drop increases as the mass flow rate of the gas increases, and also increases as the number of the heat exchanger wraps is increased. The J-T cooling temperature, shown on the right of Fig. 5, increases in proportion to the mass flow rate and the pressure drop. Note that the refrigerator with the smaller number of wraps of the heat exchanger tends to reach a lower temperature. However, with an increase in the mass flow rate, such a refrigerator may not reach a temperature of 8 K or less. When our type (I) J-T had just 12 wraps, a sudden change of the temperature occurred due to a decrease of the effectiveness of the heat exchanger at a higher mass flow. Figure 6 shows the pressure-enthalpy diagram for the refrigerator for different numbers of wraps of the finned tube. It is obvious that the pressure drop of the high pressure gas is small. With an increase in the number of wraps, the entering temperature of the high pressure gas decreases due to an increase in the effectiveness of the heat exchanger, but the J-T exit temperature of the low pressure gas increases. The liquefied yield increases as the number of wraps increases. 7 6 5 4 3 2 N=18 Temperature (K) 15 14 13 12 11 1 9 82 81 8 79 N=18 1 78..1.2.3.4.5.6.7.8 77..1.2.3.4.5.6.7 Figure 5. Pressure drop and temperature of the type (I) 5 4 3 2 (4MPa,295K) 1 1 8K 1K 12K 16K A B C 14K 18K.15.1-15 -1-5 5 1 15 2 25 3 Enthalpy (kj/kg) Figure 6. P-h diagram of the type (I) with the mass flow rate of.313 g/s. (Number of wraps A : 12, B : 18, C: 24)

46 J-T AND SORPTION CRYOCOOLER DEVELOPMENTS 6 12 5 4 3 2 II 1 8 6 4 II 1 I 2 I..1.2.3.4.5.6.7..1.2.3.4.5.6.7 Temperature (K) 85 84 83 82 81 8 79 78 (a) high pressure side (b) low pressure side Figure 7. Pressure drop of the heat exchanger (number of wraps : 18) 77..1.2.3.4.5.6.7 II I Q ref /Q ideal 1..9.8.7.6.5.4.3.2.1 I...1.2.3.4.5.6.7 (a) temperature (b) relative refrigeration Figure 8. Performance of the refrigerator (number of wraps : 18) II For the case A with 12 wraps, the temperature of the exhaust gas from the passage of the high pressure gas is 18 K, the gas is not liquefied at the exit of the J-T nozzle. It is obvious that there is a criteria for the effectiveness of the heat exchanger that is required to insure liquefaction of the gas. Figure 7 show pressure drops of the high pressure and low pressure side for the type (I), (II) and (III) heat exchangers when the supply pressure of the gas is 4 MPa and the heat exchanger has 18 wraps of the finned tube. For the high pressure side, types (II) and (III) have a smaller pressure drop than that of type (I); this is because type (II) and (III) have two passages for high pressure gas, and the mass flow rate of the gas per passage is half of that of type (I). For the low pressure side, the type (III) has a larger pressure drop than type (I), and type (II) has a smaller pressure drop than type (I). The pressure drop depends on the overall length of the heat exchanger and the flow area. The overall length of the heat exchanger of type (III) is double that of the types (I) and (II). Type (II) has twice the flow area on the low pressure side as compared to types (I) and (III). Figure 8 shows the effects of the configuration of the heat exchanger on the gas temperature after the J-T expansion and the relative amount of refrigeration. The results show that the refrigerator with type (II) heat exchanger has the lowest temperature with the same mass flow rate, but type (III) exceeds a temperature of 8 K when a small mass flow rate is used.

EFFECT OF HX CONFIGURATION ON J-T PERFORMANCE 461 5 4 3 2 1 I II (4MPa,295K) 1 8K 1K 12K 16K 14K 18K.15.1-15 -1-5 5 1 15 2 25 3 Enthalpy (kj/kg) Figure 9. P-h diagram for the J-T refrigerator (mass flow rate :.625 g/s, number of wraps : 18) A J-T refrigerator with an ideal heat exchanger of 1% effectiveness generates the maximum amount of refrigeration. The maximum refrigeration reaches 26 W when the mass flow rate exceeds.6 g/s. The configuration of the heat exchanger affects the effectiveness. The relative refrigeration decreases as the mass flow rate increases as shown in Figure 8. Type (I) has a rapid decrease of relative refrigeration, while types (II) and (III) have small decreases of relative refrigeration when the mass flow increases. When a refrigerator has a large mass flow rate of gas, type (III) has the highest refrigeration. Figure 9 shows the pressure-enthalpy diagram for the different configurations of the heat exchangers. Types (II) and (III) have similar temperatures for the exhaust of the high pressure gas. It is obvious that the type (I) has small effectiveness of the heat exchanger, and type (II) and (III) have similar effectiveness of the heat exchanger. The large pressure drop of the type (III) results in the high temperature of the gas after expansion. Finally, a refrigerator has a higher refrigeration when the overall length of the heat exchanger increases and the mass flow rate increases. In the case when two passages for the high pressure gas were employed for the J-T heat exchanger, higher refrigeration could be achieved than with a single passage for the high pressure gas. For rapid cooling, two passages for the high pressure gas is a very helpful design attribute for a J-T refrigerator. The refrigerator with heat exchanger of type (II) has the lowest temperature and highest refrigeration when a high mass flow rate of gas is utilized. SUMMARY In the present study, the effectiveness-ntu approach was adopted to predict the thermodynamic behavior of heat exchangers for J-T refrigerators using nitrogen gas, and the performance of J-T refrigerators with single and two-flow type recuperative heat exchangers was investigated. The results show the effects of the number of wraps of the finned tube, the mass flow rate, and the supply pressure of the gas on the performance of the refrigerators. The refrigerator has higher refrigeration when the overall length of the heat exchanger increases and the mass flow rate increases. But, with an increase in the mass flow rate and the number of wraps, the refrigerator could not reach a temperature of 8 K or less. For cases where two passages for the high pressure gas were employed for the J-T heat exchanger, higher refrigeration could be achieved than with a single passage for the high pressure gas. For rapid cooling, two passages for the high pressure gas is a very helpful design attribute.

462 J-T AND SORPTION CRYOCOOLER DEVELOPMENTS ACKNOWLEDGMENT This work is supported by the Korea Institute of Machinery & Materials and The Ministry of Knowledge Economy. REFERENCES 1. Guichard, J., Cottereau, A., Chazot, D., Cryogenic characterization of low cost Joule-Thomson coolers, Proceedings of SPIE, vol. 413 (2), pp. 496-56. 2. Ng, K. C., Xue, H., Wang, J. B., Experimental and numerical study on a miniature Joule-Thomson cooler for steady-state characteristics, Int. J. of Heat and Mass Transfer, vol. 45 (22), pp. 69-618. 3. Xue, H., Ng, K. C., Wang, J. B., Performance evaluation of the recuperative heat exchanger in a miniature Joule-Thomson cooler, Applied Thermal Engineering, vol. 21 (21), pp. 1829-1844. 4. Chua, H. T., Wang, X., Teo, H. Y., A Numerical study of the Hampson-type miniature Joule- Thomson cryocooler, Int. J. of Heat and Mass Transfer, vol. 49 (26), pp. 582-593. 5. Hong, Y. J., Park, S. J. and Choi, Y.D., A Numerical Study on the performance of the Miniature Joule Thomson Refrigerator, Cryocoolers 15, edited by S. D. Miller and R. G. Ross, Jr., ICC Press, Boulder CO (28), pp. 379-386. 6. Prentice, J. W., Walker, G., Zylstra, S. G., Advancements in Clog Resistant and Demand Flow Joule-Thomson Cryostats, Advances in Cryogenic Engineering, Vol. 37, Part B, edited by R. W. Fast, Plenum Press, New York (1992), pp. 963-972.