MICRO SWITCH V15W Series Watertight Miniature Switches

Similar documents
MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

V-Basic Standard V15 Series

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

MICRO SWITCH Basic Switches Line Guide

MICRO SWITCH GLL Series

MICRO SWITCH GSX Series

MICRO SWITCH Basic Switches Line Guide

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

General Purpose Industrial VRS Magnetic Speed Sensors

High Temperature Industrial VRS Magnetic Speed Sensors

HIH-5030/5031 Series Low Voltage Humidity Sensors

HIH-4000 Series Humidity Sensors

MICRO SWITCH NT Series

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

MICRO SWITCH NT Series

MICRO SWITCH BAF/DTF Series

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

FSS-SMT Series. Low Profile Force Sensor

Micropower Omnipolar Digital Hall-Effect Sensor ICs


HIH-4602-L Series Humidity Sensors

HOA6480 Series Barcode Sensor Infrared Products

MICRO SWITCH E6/V6 Series

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Wireless Panel-Mount Monitor

MICRO SWITCH BX/BX2 Series

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Installation Instructions for the 600 Series Optical Encoders

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

HFX Fiber Optic Component 50 Mbps, 650 nm LED

FEATURES AND BENEFITS

MICRO SWITCH Limit Switches Line Guide

Installation Instructions for the

Potential Applications

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

MICRO SWITCH. Pushbutton Switches Line Guide FEATURES MICRO SWITCH. PUSHBUTTON SWITCHES PB Series. Features: Compact size Up to four

Linear Current Sensors

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

HIH-4602 A & C Series.

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Intrinsically Safe Transmitters, Option Code 2n

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Airflow Sensors Line Guide

Honeywell Pressure Switches Line Guide

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MICRO SWITCH Sealed and High Accuracy Switch Line Guide

Airflow Sensors Line Guide

MICRO SWITCH Limit Switches Line Guide

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Installation Instructions for the

HIH-4030/31 Series Humidity Sensors

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Guide to Hazardous Location Approvals:

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

HIH-4010/4020/4021 Series Humidity Sensors

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Interactive Catalog Replaces Catalog Pages

TruStability Board Mount Pressure Sensors

Fiber Optics and Liquid Level Sensors Line Guide

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Wireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series)

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

MICRO SWITCH Safety Limit Switches for Hazardous Locations GSX Series Issue 3. Datasheet

Quadrature Speed and Direction Sensors

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

LCZ Series Hall-effect Zero Speed Sensors

Force Sensors Line Guide

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

WARNING MISUSE OF DOCUMENTATION

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

Transportation Applications

Transcription:

MICRO SWITCH V15W Series Watertight Miniature Switches Basic Switches DESCRIPTION The MICRO SWITCH V15W is a standard-sized basic switch designed for harsh-duty, wash down areas. Rugged yet precise, the Series gives highly accurate machine control for turning circuits on and off. The V15W can be used in a wide range of challenging environments, including food packaging plants, forklifts, ATVs, golf carts, lawn mowers, garbage trucks, salt trucks, commercial buses, and wheelchair lifts for conversion vans. Choose the V15W when the application needs accurate repeatability in a compact, lightweight and long-lasting basic switch. This switch signifies an expansion of the proven and reliable, MICRO SWITCH V15 Standard snap-action switch series. By utilizing an epoxy resin, the V15W Series switches deliver high sealing capability with an IP67 rating (pre-leaded only). They may also be used in dusty places or in washdown applications. FEATURES AND BENEFITS Degree of protection: IP67 (except terminal parts) to operate under difficult environmental conditions Wide current range: 0.1 A, 5 A, 10 A SPDT, SPNO, and SPNC options For engineering design flexibility, the V15W Series features a variety of straight, roller, simulated roller, and special actuators to choose from Pre-leaded wires for easy installation Special terminations available upon request Gold contacts available Wide temperature range Metric or USA mounting holes Long mechanical/electrical service life Global approvals: UL, cul, ENEC, and CQC for reliable and consistent performance within a range of conditions RoHS compliant APPLICATIONS Industrial o Appliances o Communication equipment o Computers o Electric tools o Electromechanical timers o HVAC wall controls o Instrumentation o Mechanical cam assemblies (timers) o Office equipment o Valves o Vending machines Transportation o Automotive, truck, and boat wire harnesses o Lock modules for tail-gate/trunk o Sub-assemblies for convertible roofs o Tank and hood latch detection Medical o Chair lifts o Foot pedal controls o Medical and hospital beds

MICRO SWITCH V15W Series Watertight Miniature Switches SPECIFICATIONS Characteristic Electrical rating Circuitry Operating force Temperature rating Operating speed Operating frequency Insulation resistance Contact resistance Contacts Terminals Wiring Wire sizes Electrical life Mechanical life Weight Approvals Case material Plunger seal External lever Mounting holes Parameter 0.1 A, 5 A, 10 A SPDT, SPNC, SPNO 15 g, 25 g, 50 g, 100 g, 200 g -40 C to 85 C [-40 F to 185 F] 0,1 mm to 1 m/s (at plunger) 200 operations/minute max. (mechanical) 30 operations/minute max. (electrical) 100 MOhm min. at 500 Vdc 100 mohm max. 300 mohm max. for lead wire models Silver nickel, gold-plated option 4,8 mm x 0.8 mm or 4,8 mm x 0.5 mm 300 mm long wire W1 24 AWG; W2 20 AWG; W3 16 AWG W1 (0.1 A): 50000 cycles ENEC, 10000 cycles UL W2 (5 A): 50000 cycles ENEC, 10000 cycles UL W3 (10 A): 20000 cycles ENEC, 10000 cycles UL 1 million cycles 8 g (terminal versions); 18 g (pre-wired versions) UL, cul, ENEC, CQC PBT Silicone rubber Stainless steel Metric or USA 2 www.honeywell.com/sensing

Basic Switches Figure 1. V15W Product Nomenclature MICRO SWITCH V15W Series Standard Listings Part Number V15W11-EZ200-W3 V15W11-WZ200-W3 V15W11-DZ200-AW1 V15W11-DZ200A06-AW1 V15W11-DZ200A02-AW1 V15W11-DZ200A06-W2 V15W11-DZ200A02-W2 V15W11-WZ200A02-W2 V15W11-WZ200A06-AW1 V15W11-DZ200A05-AW1 V15W11-DZ200A04-W2 V15W11-WZ200A02-AW1 Description Switch, 4,8 mm x 0.5 mm terminals, SPDT, 200 g operating force, pin plunger, ENEC/CQC: 10(2) A 125/250 Vac; 0.5 A 125 Vdc, 0.25 A 250 Vdc, 40T85 2E4; UL/cUL: 10.1 A 1/10 HP 125/250 Vac; 0.5 A 125 Vdc, 0.25 A 250 Vdc (10K cycles) Switch, 300 mm long wires, SPDT, 200 g operating force, pin plunger, ENEC/CQC: 10(2) A 125/250 Vac; 0.5 A 125 Vdc, 0.25 A 250 Vdc, 40T85 2E4; UL/cUL: 10.1 A 1/10 HP 125/250 Vac; 0.5 A 125 Vdc, 0.25 A 250 Vdc (10K cycles) force, pin plunger, gold-plated contacts, ENEC/CQC: 0.1 A 125/250 Vac, 0.1 A 48 Vdc, 40T85 5E4; UL/cUL: 0.1 A 125/250 Vac; 0.1 A 48 Vdc (10K cycles) force, lever pivot far from plunger, long-roller lever, gold-plated contacts, ENEC/CQC: 0.1 A 125/250 Vac; 0.1 A 48 Vdc, 40T85 5E4; UL/cUL: 0.1 A 125/250 Vac; 0.1 A 48 Vdc (10K cycles) force, lever pivot far from plunger, standard straight lever, ENEC/CQC: 0.1 A 125/250 Vac; 0.1 A 48 Vdc, 40T85 5E4; UL/cUL: 0.1 A 125/250 Vac; 0.1 A 48 Vdc (10K cycles) force, lever pivot far from plunger, long-roller lever, ENEC/CQC: 5 A 125/250 Vac; 5 A 30 Vdc, 40T85 5E4; UL/cUL: 5 A 125/250 Vac; 5 A 30 Vdc (10K cycles) force, lever pivot far from plunger, standard straight lever, ENEC/CQC: 5 A 125/250 Vac; 5 A 30 Vdc, 40T85 5E4; UL/cUL: 5 A 125/250 Vac; 5 A 30 Vdc (10K cycles) Switch, 300 mm long wires, SPDT, 200 g operating force, lever pivot far from plunger, standard straight lever, ENEC/CQC: 5 A 125/250 Vac; 5 A 30 Vdc, 40T85 5E4; UL/cUL: 5 A 125/250 Vac; 5 A 30 Vdc (10K cycles) Switch, 300 mm long wires, SPDT, 200 g operating force, lever pivot far from plunger, long-roller lever, gold-plated contacts, ENEC/CQC: 0.1 A 125/250 Vac; 0.1 A 48 Vdc, 40T85 5E4; UL/cUL: 0.1 A 125/250 Vac; 0.1 A 48 Vdc (10K cycles) force, lever pivot far from plunger, roller lever, gold-plated contacts, ENEC/CQC: 0.1 A 125/250 Vac; 0.1 A 48 Vdc, 40T85 5E4; UL/cUL: 0.1 A 125/250 Vac; 0.1 A 48 Vdc (10K cycles) force, lever pivot far from plunger, simulated roller lever, ENEC/CQC: 5 A 125/250 Vac; 5 A 30 Vdc, 40T85 5E4; UL/cUL: 5 A 125/250 Vac; 5 A 30 Vdc (10K cycles) Switch, 300 mm long wires, SPDT, 200 g operating force, lever pivot far from plunger, standard straight lever, gold-plated contacts, ENEC/CQC: 0.1 A 125/250 Vac; 0.1 A 48 Vdc, 40T85 5E4; UL/cUL: 0.1 A 125/250 Vac; 0.1 A 48 Vdc (10K cycles) Honeywell Sensing and Control 3

MICRO SWITCH V15W Series Watertight Miniature Switches Figure 2. Switch Package Dimensions [mm] Figure 3. Other Switch Terminal Options 4 www.honeywell.com/sensing

Basic Switches Figure 4. Switch Lever Options 01 Short Straight Lever 02 Standard Straight Lever 03 Long Straight Lever 04 Simulated Roller Lever 05 Roller Lever 06 Long Roller Lever Figure 5. Switch Operating Characteristics Honeywell Sensing and Control 5

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com/sensing 004965-1-EN IL50 GLO Printed in USA September 2011 Copyright 2011 Honeywell International Inc. All rights reserved.