OPTICAL FIBER SOLUTIONS

Similar documents
Clearlite Photonic Fibers

PUMP AND SIGNAL COMBINERS

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Product Specification

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

OPTICAL FIBER SOLUTIONS

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

LaserPlus Model LP-OA EDFA OPERATING MANUAL

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Product Specification

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Cooled Butterfly 980nm Pump Laser Module

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Acterna MTS 5000 e Series OTDR and Loss Test modules

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

Product Specification

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

OPTICAL AMPLIFIERS SELECTION GUIDE

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

T-BERD 6000 Compact Optical Test Platform

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Packaging in Consumer Goods

Fibre Specification Standards

gray Laser Power Detectors For fast and accurate measurements

MT-RJ Optical Fiber System Field Testing

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

MTTplus Modular Test Platform

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

Field Test Procedure for Optical Fibre Link Measurements

4120 Fire Alarm Network Reference

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Return loss measurement of fiber optic components

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

MAJOR CONCERN on your GENERATORS?

Splice Trays Selection SCF Closures

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

Broadband System - H

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

Basic Professional Fiber Optic Installation

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

HELKAMA. Optical Fibre Cables

SAFE TRANSPORTATION OF LIQUID SULPHUR

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Reinforced FBG Sensors Serve Demanding Applications

Fiber Optic Cable Fence Disturbance Sensor

Four channel video link For low cost video transmission

50 W Laser Concepts for Initial LIGO

OFS IV Optical Fibre System

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Fli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution

Optical Time Domain Reflectometry (OTDR)

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

High cost performance choice

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

Health Monitoring System Using FBG-Based Sensors for a 12-Story Building with Column Dampers.

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

WELL & RESERVOIR MONITORING

Understanding total measurement uncertainty in power meters and detectors

OZ Optics Limited. Fiber Optic Attenuators. June 2018

M700-Series Multifunction OTDR

Fusion Splicing Recommendations for OFS Rollable Ribbon Using the Fitel S123 M12 Fusion Splicer

EXTENDING RAMAN INTO THE THz REGIME

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

RAMAN SPECTROSCOPY See more, faster than ever before

High cost performance choice

Chapter 1. Introduction

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

OPX-BOX. Platform Highlights. Software Support. Key Features

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

industry solutions: military

CMA4000i Optical Test System

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

Fibre Optic Sensors: basic principles and most common applications

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

MITSUBISHI ELECTRIC ANNOUNCES DEVELOPMENT OF 5.6 W 213 nm DEEP ULTRAVIOLET SOLID STATE LASER

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

May 28th, Réseau Fibré Métrologique à Vocation Européenne

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Phoenix Artificial Lift Downhole Monitoring. Improving artificial lift system performance

UV LED Curing: The Time is Now

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)


Computerised Analysis of OFM in Communication Theory

Transcription:

RightWave Erbium-Doped Optical Fiber Critical component for the amplification of optical transmission signals A Furukawa Company Broad portfolio suited to diverse needs Proven product uniformity, quality and performance Impeccable service for supply-chain agility www.ofsoptics.com OPTICAL FIBER SOLUTIONS FOR OPTICAL AMPLIFIER DESIGN Applications Amplifiers DWDM Optical Amplifiers CATV Amplifiers High-Power Optical Amplifiers Single-stage or Multi-stage Amplifiers Networks Metro and Long Haul Networks Storage Networks and Disaster Recovery Packet Optical Networks Marine Networks www.ofsoptics.com

World class EDF products and services, combined with a laser like focus on customer needs from specifications to delivery, truly differentiate OFS as a trusted fiber solutions partner. Variety, Experience, Repeatability Erbium-doped fiber (EDF) continues to be a critical component for the amplification of optical transmission signals. In telecom there is a broad range of amplifier applications including EDFA, CATV and DWDM amplifiers, which can be designed for low to very high pump powers. OFS offers the broadest portfolio of EDF in the telecom industry to meet your specific requirements for C- and L-Band amplifiers as well as amplified spontaneous emission (ASE) sources. Since the very onset of EDFA technology, OFS has been investing in and employing state-of-the-art equipment to develop and manufacture its RightWave EDF products. Silica Core Silica Clad Acrylate Coating Principle of Erbium-Doped Fiber Amplifier (using RightWave Erbium-Doped Fiber) Signal-In Amplified Signal-Out Pump

RightWave Erbium-Doped Optical Fiber Critical component for the amplification of optical transmission signals Features and Benefits Some advantages of selecting OFS, an industry leader in Erbium-Doped Fiber (EDF), as your fiber solutions partner include: Broad EDF Portfolio With a strong commitment to the EDF market and its needs, OFS offers the broadest EDF portfolio in the telecom industry today. Experience and Delivery OFS holds a strong track record of continually delivering large volumes of highperformance EDF to the general market. Manufacturing Capacity Production in an ISO-certified environment helps to ensure a consistently dependable supply of EDF products. Specialty Services For more than 10 years, OFS has provided specialty fiber services globally, meeting precise customer specifications for amplifier designs, colored coatings and a variety of spool sizes. Gain Flatness OFS achieves broader and flatter gain spectra by using high aluminum levels, making fibers more suitable for DWDM and CATV applications. OASiX Modeling Software The OFS OASiX Optical Amplifier Simulation System is a sophisticated simulation software package that helps determine which OFS EDF is best for you. OASiX is provided free of charge to OFS EDF customers to model the performance of OFS EDF in accurate design simulations maximizing performance of system design. This software package, featuring an enhanced user interface, allows the simulation of a wide variety of EDFA types to predict which fiber is best for your application. ASE sources and laser designs are also incorporated in this proprietary software package. This specialized software package allows a system engineer to enter custom setup conditions, which can accurately predict EDF performance at all pump powers. OASiX also includes modeling parameters specific to the lot of EDF purchased, and it is available in a Dynamic Link Library (DLL) version to combine with other external optimization tools. OFS continues to issue new releases of OASiX to keep pace with the evolving needs of EDFA designers. Many customers see value in using OASiX for simulation as it can save them valuable measurement time, reduce fiber waste and also help optimize amplifier design. Uniformity Fiber helps ensure low variability within fiber lots and repeatable performance from lot-to-lot, simplifying EDFA design and manufacturing. Hydrogen Immunity OFS patented processes help to prevent hydrogen (H2) induced attenuation loss for enhanced performance. Low Polarization Mode Dispersion Low PMD allows the fibers to perform in high data rate applications. Quality Using ISO 9001 and TL 9000 certified manufacturing processes helps ensure that OFS EDF products meet the most stringent standards for quality, performance and reliability. High Power-Conversion Efficiency Fibers are optimized to provide maximum efficiency within various pump-power operating ranges. OFS has a corporate heritage in EDF going back to 1989. With over 20,000 kilometers shipped in the past ten years alone, OFS market-leading fibers are the desired choice for amplifier designs deployed throughout the world. High Reliability Processing for H2 immunity helps ensure highly consistent EDF products. Splicing OFS patented processes help deliver splicing improvements (parameters available upon request). OFS also offers custom splicing services for optimum results. 3

OPTICAL FIBER SOLUTIONS FOR OPTICAL AMPLIFIER DESIGN EDF continues to be a critical component in amplifier design for metro, long-haul and marine optical networks. Overview The RightWave EDF portfolio has a broad EDF product line as each fiber type is optimized for different applications. The tables below presents an overview of our various fiber types. RightWave EDF for C-Band GP980 22904 A general purpose fiber designed for a wide range of applications, including single-stage, single-channel, narrow bandwidth and metro amplifiers, where tight lot tolerances and full blown characterization are not necessary. CATV, DWDM, Single-stage Amplifiers MP980 27299 A medium power fiber designed for many configurations of EDFAs. It can be used as a single-stage amplifier fiber at higher than 100mW pump powers. The most popular fiber type used in EDFA design, due to a well-balanced combination of broadband gain, gain flatness, bend loss and noise figure. CATV, DWDM, Single-stage Pre-amplifier and Multi-stage Amplifiers MP980-II 61376 A new high efficiency fiber designed for a wide range of pump powers up to 600mw. This fiber has a lower noise figure with better transient response time CATV, DWDM, Single-stage, Pre-amplifier and Multi-stage Amplifiers HP980X 61378 All the high power fiber characteristics with a higher cutoff wavelength resulting in higher efficiency. CATV, DWDM, Multi-stage Amplifiers HE980 61380 A high efficiency fiber designed for low to medium pump powers ranging up to 500mW, optimized for pre-amplifier stage in a multi-stage amplifier due to low noise figure with moderate gain. The high NA allows for a smaller bend radius. CATV, DWDM, Single-stage, Pre-amplifier stage and Multi-stage Amplifiers R37003X 27270 A high efficiency fiber designed for pump powers in the range 25-300mW. This product has a broad gain profile, excellent spectral reproducibility and bath-to-batch uniformity, supported by precision characterization in a real DWDM amplifier setup. The fiber is designed for improved splice performance for low splice loss. CATV, DWDM, Optical Amplifiers, Splicing applications RightWave EDF for L-Band LSL 61372 L-Band fiber designed for high efficiency, low noise figure, low non-linear effects and spectral flatness in DWDM amplifiers. DWDM, Transport LRL 61373 L-Band fiber designed for high efficiency, low noise figure, low non-linear effects and spectral flatness in DWDM amplifiers, reducing the length needed in amplifier design. Compact Amplifiers, DWDM Amplifiers LPL 76675 L-Band fiber designed for high efficiency, low noise figure, low non-linear effects and spectral flatness in DWDM amplifiers, reducing the length needed in amplifier design. Compact Amplifiers, DWDM Amplifiers R37103e 27325 A fiber designed specifically for L-band amplifiers operating in the 1565-1610 nm range. The fiber has high efficiency and low noise figure with excellent spectral uniformity, supported by precision characterization in DWDM amplifiers and incorporating the latest improvements in splice performance. CATV, DWDM 4 www.ofsoptics.com

RightWave Erbium-Doped Optical Fiber Critical component for the amplification of optical transmission signals RightWave EDF for ASE Sources and Remote Optically Pumped Amplifiers (ROPA) HG980 61379 A fiber with high NA and moderate erbium concentration for ASE source applications. ASE Sources, pumping at either 980 or 1480 nm LP980 76943 A low power fiber designed for use in marine applications, where amplifiers are remotely pumped to reduce the number of amplifiers. This may also be used in disaster recovery applications. ROPA for Marine Network Spans, Disaster Recovery, Storage Networks ASE 25 80 35644 80 µm cladding allows for very tight bend radii without compromising the device reliability. Small form factor ASE Sources, Pumping at either 980 or 1480 nm RightWave 80 µm EDF for Compact Amplifiers R37003X 80 40902 80 µm version of the fiber, reducing the length needed in amplifier design. C-Band Compact Amplifiers LSL 80 75882 80 µm version of L-Band fiber, with reduced cladding designed for high efficiency, low non-linear effects, low noise figure and spectral flatness in DWDM amplifiers as well as smaller bend radius for compact amplifier design. L-Band Compact Amplifiers LRL 80 76176 80 µm version of reduced length L-Band fiber, with reduced cladding designed for high efficiency, low noise figure, low non-linear effects and spectral flatness in DWDM amplifiers as well as smaller bend radius needed for compact amplifier design. L-Band Compact Amplifiers LPL 80 76178 80 µm version of reduced length L-Band fiber, with reduced cladding designed for high efficiency, low noise figure, low non-linear effects and spectral flatness in DWDM amplifiers as well as smaller bend radius needed for compact amplifier design. L-Band Compact Amplifiers 5

OPTICAL FIBER SOLUTIONS FOR OPTICAL AMPLIFIER DESIGN RightWave Polarization Maintaining EDF EDF07 PM 31946 A PM-fiber with absorption of 7 db/m at 1530 nm. The polarization maintaining properties are achieved by using a stress rods design. Fiber Lasers, PM-Amplifiers EDF25 PM 27242 A PM-fiber with absorption of 25 db/m at 1530 nm. The polarization maintaining properties are induced by its elliptical core design. Fiber Lasers, PM-Amplifiers EDF50 PM 27281 A PM-fiber with absorption of 50 db/m at 1530 nm. The fiber has an elliptical core design with high erbium concentration making it attractive for very short fiber use in the laser cavity. Fiber Lasers, PM-Amplifiers RightWave Highly Doped Erbium EDF, Ytterbium and Thulium Doped EDF EDF80 27308 A fiber with absorption of 80 db/m at 1530 nm. Fiber Lasers EDF150 27307 A fiber with absorption of 150 db/m at 1530 nm. Fiber Lasers EDF150 LD 27326 A low dispersion fiber with absorption of 150 db/m at 1530 nm. Fiber Lasers YbDF320 PM EC 40906 A Ytterbium doped polarization maintaining fiber. The fiber birefringence is due to its elliptical core design. The absorption is 320 db/m at 977 nm, whereas the cladding of the fiber is photosensitive. Fiber Lasers YbDF350 40908 A Ytterbium doped fiber with an absorption of 350 db/m at 977 nm. The cladding of the fiber is photosensitive. Fiber Lasers TmDF200 40910 A Thulium doped fiber with an absorption of 200 db/m at 790 nm. The cladding of the fiber is photosensitive. Fiber Lasers Quality products, customer part codes, flexible capacity production, consistency and service agility are just some attributes that make OFS the no-risk choice for amplifier manufacturers. 6 www.ofsoptics.com

RightWave Erbium-Doped Optical Fiber Critical component for the amplification of optical transmission signals RightWave Erbium-Doped Fibers Fiber Peak Absorption Numerical Aperture Mode Field Diameter Cutoff Wavelength Cladding/Coating Diameter Part Number C-Band GP980 @ 1530 nm; 13 ± 1.5 db/m 0.24 ± 0.02 @ 1550 nm; 5.5 ± 0.7 µm 920 nm 125/245 µm 22904 MP980 @ 1530 nm; 6.5 ± 1.0 db/m 0.21 ± 0.02 @ 1550 nm; 6.2 ± 0.7 µm 910 nm 125/245 µm 27299 MP980-II @ 1530 nm; 7.5 ± 1.0 db/m 0.22 ± 0.02 @ 1550 nm; 5.5 ± 0.7 µm 1170 nm 125/245 µm 61376 HP980X @ 1530 nm; 7.0 ± 1.0 db/m 0.18 ± 0.02 @ 1550 nm; 6.8 ± 0.7 µm 1040 nm 125/245 µm 61378 HE980 @ 1530 nm; 4.0 ± 1.0 db/m 0.26 ± 0.02 @ 1550 nm, 5.1 ± 0.7 µm 910 nm 125/245 µm 61380 R37003X @ 1530 nm; 7.0 ± 1.0 db/m 0.26 ± 0.02 @ 1550 nm; 5.3 ± 0.7 µm 920 nm 125/245 µm 27270 L-Band LSL @ 1530 nm; 17.0 ± 2.0 db/m 0.26 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 1230 nm 125/245 µm 61372 LRL @ 1530 nm; 30.0 ± 3.0 db/m 0.26 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 1230 nm 125/245 µm 61373 LPL @ 1530 nm; 37 ± 3.0 db/m 0.26 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 1230 nm 125/245 µm 76675 R37103e @ 1530 nm; 18.0 ± 2.0 db/m 0.25 ± 0.02 @ 1550 nm; 5.3 ± 0.7 µm 940 nm 125/245 µm 27325 ASE Sources and Remote Optically Pumped Amplifiers HG980 @ 1530 nm; 17.0 ± 2.0 db/m 0.26 ± 0.02 @ 1550 nm; 5.1 ± 0.7 µm 920 nm 125/245 µm 61379 LP980 @ 1530 nm; 5.5 ± 1.0 db/m 0.32 ± 0.02 @ 1550 nm; 4.3 ± 0.7 µm 940 nm 125/245 µm 76943 ASE 25 80 @ 1530 nm; 25 ± 3 db/km 0.31 ± 0.02 @ 1550 nm, 4.3 ± 0.7 µm 930 nm 80/165 µm 35644 80 µm EDF for Compact Amplifiers R37003X 80 @ 1530 nm; 9.0 ± 2.0 db/m 0.27 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 920 nm 80/165 µm 40902 LSL 80 @ 1530 nm; 17.0 ± 2.0 db/m 0.26 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 1230 nm 80/165 µm 75882 LRL 80 @ 1530 nm; 30.0 ± 3.0 db/m 0.26 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 1230 nm 80/165 µm 76176 LPL 80 @ 1530 nm; 37 ± 3.0 db/m 0.26 ± 0.02 @ 1550 nm; 4.9 ± 0.7 µm 1230 nm 80/165 µm 76178 Polarization-Maintaining EDF EDF07 PM SR @ 1530 nm; 7 db/m 0.21 ± 0.02 @ 1550 nm; 5.5 ± 0.7 µm 920 nm 125/245 µm 31946 EDF25 PM EC @ 1530 nm; 25 db/m 0.27 ± 0.02 @ 1550 nm; 5.2 ± 0.7 µm 1150 nm 125/245 µm 27242 EDF50 PM EC @ 1530 nm; 50 db/m 0.27 ± 0.02 @ 1550 nm; 5.4 ± 0.7 µm 1260 nm 125/245 µm 27281 Highly Doped EDF EDF 80 @ 1530 nm; 80 db/m 0.28 ± 0.02 @ 1550 nm; 4.3 ± 0.7 µm 950 nm 125/245 µm 27308 EDF150 @ 1530 nm; 150 db/m 0.28 ± 0.02 @ 1550 nm; 4.3 ± 0.7 µm 925 nm 125/245 µm 27307 EDF150 LD @ 1530 nm; 150 db/m 0.22 ± 0.02 @ 1550 nm; 5.6 ± 0.7 µm 930 nm 125/245 µm 27326 Ytterbium and Thulium Doped EDF YbDF350 @ 977 nm; 350 db/m @ 915 nm; 110 db/m 0.23 ± 0.02 @ 1000 nm; 3.6 µm 890 nm 125/245 µm 40908 YbDF320 PM EC @ 977 nm; 320 db/m @ 915 nm; 100 db/m 0.23 ± 0.02 @ 1000 nm; 3.6 µm 1000 nm 125/245 µm 40906 TmDF200 @ 790 nm; 200 db/m 0.26 ± 0.02 @ 1700 nm; 5.0 µm 1350 nm 125/245 µm 40910 7

For additional information please contact your sales representative. You can also visit our website at www.ofsoptics.com or call 1-888-FIBER-HELP (1-888-342-3743) from inside the USA or 1-770-798-5555 from outside the USA. EMEA Specific: +49 (0) 228 7489 201 OASiX and RightWave are registered trademarks of OFS Fitel, LLC. OFS reserves the right to make changes to the prices and product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any OFS warranties or specifications relating to any of its products or services. Copyright 2018 OFS Fitel, LLC. All rights reserved. OFS Marketing Communications 01/18