Residential Demand Controller Program

Similar documents
Computerized Energy Management

MODEL 9308 ENERGY MANAGEMENT COMPUTER OWNER'S MANUAL

HOME ENERGY DETECTIVES

CITY OF BARTOW (COB)

What Everyone Should Know About Electricity

SMART METERS ANSWER BOOK HOW YOU WHY ONTARIO WHAT ARE GETTING SMART ABOUT CAN START TO PREPARE NOW PAGE 6 TIME-OF-USE PRICES? PAGE 4 IS INTRODUCING

CHECK OUT ENERGY SAVINGS BROUGHT TO YOU BY ENERGY TRUST OF OREGON

INTRODUCTION WHAT THE EMS-1000 IS DESIGNED TO DO HOW THE EMS-1000 OPERATES EMS CONTROL PANEL INITIAL SETUP SETUP CLOCK DIGITAL DISPLAY

H o m e G e n e r a t o r S y s t e m s

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

Byrd Barr Place PSE HELP Program:

How to save money on energy at home

You will investigate the electrical consumption in your home over the course of TWO days (48 hour period).

CUSTOMER SERVICE CODE OF PRACTICE

home energy consumption list A list of electric household appliances, and their operating cost northlandutilities.com

Home Energy Audit. Overview. Objectives. Time Requirements. Materials. Procedure CON EDISON WEB-BASED MIDDLE SCHOOL ACTIVITY

Tips To Help Conserve Electricity

Bathroom SAVING ENERGY AROUND THE. If you go on vacation, turn the temperature selector to the lowest setting.

save I have the power to A helpful guide to making your home wattsmart _RMP_wattsmart Handbook_Resize_5.5x7.75_F2.indd 1

Use numbers given in the box to complete the following sentences. In the UK, the mains electricity supply is volts.

SAVING ENERGY AROUND THE

What is solarcache touch? How does it work? What can I see on the screen?

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Your Personal Energy Audit Data Table, completed (handwritten is acceptable) A typed paragraph or two addressing each of the following topics.

Keep your electricity bill cool this summer

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

DO IT YOURSELF ENERGY AUDIT

Price increases since % 38% 53% 63% 115% Ground Beef. Electricity Eggs White Bread

Science 10-Electricity & Magnetism Activity 14 Chapter 5 Review

Outdated Publication, for historical use. CAUTION: Recommendations in this publication may be obsolete. Family Community Education.

AIR CONDITIONER ELECTRONIC CONTROL

ENERGY COSTS GUIDE FOR COMMON HOUSEHOLD APPLIANCES ENERGY SMART

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

Instructions for using the Kill a Watt device in the derivation of a personal carbon footprint.

1103 Period 12: Power

PROGRAMMABLE THERMOSTAT

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

OPERATING INSTRUCTIONS

We will help you find ways to save energy and money, while keeping your home comfortable. energy matter$

OPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A

Contents. General appliance information

Your floor to ceiling guide

Lesson #3 Your Energy Budget How much energy are you wasting?

Coloring and Activity Book

Remote Controller. <Open the front cover> <ARC452A4>

KILL A WATT EZ USER MANUAL. For more information visit our

YEARLY VIEW. 6/28/2016

SAVE 60% Or More On YOUR Home Heating Costs With Electric Thermal Storage

Section 9. Comparing Energy Consumption: More for Your Money. What Do You See? What Do You Think? Investigate. Learning Outcomes

SLIDER CASEMENT AIR CONDITIONER

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

.quak socialaction.or g.uk Upda ted Augus t 2018

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Advance Pay. energy use guide

Ways to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save

Energy Efficiency in the Home

Multiple use Digital Thermometer With 7 Day Memory

Tom O'Connor cut his electric bill 80 percent, and says you can too by Robert E. Thomas

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

On initial power up the thermostat will guide you through set up procedure for the following:

Bathroom SAVING ENERGY AROUND THE. If you go on vacation, turn the temperature selector to the lowest setting.

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Your Energy Profile Activity

EASY WAYS TO SAVE ENERGY AND MONEY

Contents. Glossary

Air Force Utility Allowance Program (UAP) Frequently Asked Questions (9-5-17)

SC Installation, Operation & Application Guide

Owner s Manual MODEL 8555

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Environmental Footprint ENERGY

DYGIZONE GJD910 Lighting Controller & Enunciator

Air conditioners are the biggest source of electric use in the summer. In many homes, it will account for more the ½ of your electric bill.

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Energy Management Wiring Guide

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

ACTIVITY 1 IT ALL ADDS UP Part A. Discuss the sections on the sample electric bill and provide time for students to graph the

INSTRUCTION MANUAL PC255O

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

Operating Instructions Air Conditioner

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

DAY/TIME Button: Selects hour, minute and day setting.

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ABCs of Air Conditioners...8 Water Heaters Refrigerators-Freezers Lighting... 14

INSTRUCTION MANUAL PC255O

IDS816 User Manual H Issued January 2009

APPENDIX G THE LOAD ALLOCATED TO EACH LOAD CATEGORY CLOAD MODELS

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

DESIGN & TECHNICAL MANUAL

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

HEAT COOL. Meets Commercial California Title 24

Programmable Load Management Thermostat

EASY WAYS TO SAVE ENERGY AND MONEY

MY HOME. tips. made easy. energy savings. 16 everyday. energy secrets

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

Your property and you

DAY/TIME Button: Selects hour, minute and day setting.

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Transcription:

Residential Demand Controller Program Instructional manual Energy Sentry models 9312 Align mark to the right with right edge of document.

Table of Contents Introduction and overview... 1 System description... 1 Control/display unit (panel)... 1 How to operate your Demand Controller... 2 Features for Alpha, ES, and 9312 controllers... 3 Setting the demand limit... 9 Hints for maximum savings... 9 Load shedding sequence... 9 Control of clothes dryer... 10 Load control strategies... 10 Service of heating/air conditioning, and water heater...11 If you need service...11 Residential Demand Controller customer service program... 12 Charts and tables... 13 & 14 What is a kilowatt? Demand limit and usage is measured by kilowatts. One kilowatt is equal to 1,000 watts. For example, if you have 10 100-watt light bulbs on at once, your demand is 1,000 watts or 1 kilowatt. If they remain on for one hour, the energy used is one kilowatt hour. What is demand? Demand is the rate at which you use electricity during a 15-minute period. As you turn on more lights, appliances and electric heating equipment, you are increasing your individual demand or your rate of use. Most households use the most electricity from 4 p.m. to 8 p.m. This high residential demand, multiplied by all the homes in the area, is what puts the squeeze on our generators. If enough customers were to cut back on their maximum demand, it can limit the amount we have to spend to meet an area s power requirements. The savings then can be passed on to customers who reduce the maximum rate at which they used electricity. Introduction and overview Welcome to our Residential Demand Controller Program. As the owner of a home metered under the residential demand service rate, you are now one of a growing number of customers who can lower their monthly electric bills by reducing energy demand peaks. The Energy Sentry Demand Controller lets you reduce these peaks while maintaining efficient use of energy. System description Your electronic unit only controls loads connected to your Demand Controller. So, typically, it controls deferrable loads like electric heaters, heat pumps, air conditioners, electric water heaters, hot tubs and clothes dryer heating elements. These loads will vary depending on the application and should be listed in the space provided inside the door of the control/ display unit. If you don t know which loads the unit is controlling or want more information about the residential demand service rate, contact us (see the back cover for contact information). Control/display unit (panel) The control/display unit contains the Energy Sentry micro-processorbased computer that automatically controls loads connected through the relays in the Relay Unit. This unit should be in an area of your home that you can easily access. The commands to switch these loads originate here and are based on the user-set demand limit and the actual demand as measured by the current transformers. The way in which the loads are switched is based upon the load control strategies programmed into your unit according to your requirements. If your power goes out, the unit s EEPROM memory will remember the demand limit that you set and will continue to perform demand control within that limit when power is restored. Your Energy Sentry electrical Demand Controller consists of three basic components. These include the control/display unit in your home, the relay unit next to your electrical panel, and, if you have a heat pump, the remote relay box mounted on the electric furnace. This manual explains only the operation of the control/display unit. See your Energy Sentry installation manual for details on the relay unit and current transformer, as well as other information about the system. 1

Maximum value feature All of the model 9312 units are automatically installed with the maximum value feature included. The maximum value feature gives you three times the on-peak limit for greater flexibility of electrical usage during off-peak hours. Features for the 9312 controller: Each indicator and key serves a specific purpose in providing you with the necessary information and control to minimize peak energy usage. Each of these indicators and keys has been numbered and are described on the following pages. Use as much electricity as you want in off-peak. You still pay the lower total usage rate, with no penalty for a higher demand. Your savings can be substantial. If you have any questions about the maximum value feature, give us a call. MODE KW DEMAND/TIME 1 2 AM 3 PM 4 REDUCE LOAD CIRCUIT ON 1 2 3 4 5 6 7 8 5 How to operate your Demand Controller Power available When the LED numbers in the circuit on area are lit, there is power available to that assigned load. Each number represents a relay that controls one or more assigned loads. When the number is not lit, power is unavailable. The installer should record the circuit assignment numbers on the inside of the control panel door at the time of installation. You should also record the loads controlled in the back of the installation manual you received from the electrician during installation. Each number represents a relay that can switch up to two circuits at a time. Your Demand Controller will control up to 16 points in the circuit on area. If the display LEDs are not lit, check the appropriate 15-amp breaker in the main circuit panel to see if it is on. If power is on and the LEDs are still not lit, call us for service. 1 2 DECREASE 6 13 INCREASE 7 TO SET DEMAND LIMIT, DISPLAY BRIGHTNESS, OR ALARM VOLUME CIRCUIT ASSIGNMENT 14 DEMAND DISPLAY ALARM INST RESET 8 9 10 DISPLAY 11 AVG PEAK 12 LIMIT BRIGHT VOLUME LIMIT CLOCK PEAK Mode: This indicator displays which mode the Demand Controller is currently in. It will be in one of these modes: instantaneous demand (Id), average demand (Ad), peak demand (Pd), demand limit (dl), or clock (CL). kw Demand/Time: This indicator displays total household demand, which includes controlled and uncontrolled loads. KW Demand/ Time may be displayed as instantaneous, average, peak, or current time depending upon the desired display mode. Demand limit is also shown. Instantaneous kw Demand (id): When this mode is selected, the kw Demand/Time display will indicate instantaneous demand showing changes in demand of controlled and uncontrolled loads as they occur. This is useful to let you know how much energy is required to operate various loads. Your actual demand may be compared to the typical residential appliance ratings given in Table 2. 2 Average kw Demand (Ad): In this mode, the kw Demand/Time display will indicate your average demand during a running 15-minute interval selected in the system programming mode. This is similar to the average demand interval used by your utility meter and is about equal to the demand level your meter is presently recording. The (Ad) will be lit when in this mode. 3

3 4 5 6 Peak kw Demand (Pd): In this mode, the kw Demand/Time display will indicate the highest actual average peak demand since reset. This indicator allows you to monitor your daily or weekly peaks to understand how and when these peaks occur. In this way, you can modify your energy-use patterns if you want to. Note that if this indicator is reset only when the utility meter is reset, your peak values should be about the same as the reading on the meter. A difference between the utility meter peak and peak kw demand may occur, however, due to different average demand intervals, varying line voltages, power outages, measurement accuracy and other factors. The utility meter will be the indication used in determining your electric bill demand charge. The peak light will be on when in the peak kw demand mode. Demand Limit (dl): In this mode, the kw Demand/Time display will show your current home demand limit set point. You can adjust this function using the demand limit key and the decrease/increase keys. During Off Peak, the dl mode will read the calculated Off Peak demand limit, which for Black Hills Energy is 3 times the demand limit. You may have to adjust the demand limit because of the weather or your lifestyle. Clock (CL): In this mode, the kw Demand/Time display will show the current time. If you believe the time is not correct, please give us a call. A.M. P.M.: LED will only be present when the Demand Controller is in the clock mode. Reduce Load: The Reduce Load indicator will come on and the alarm will sound when all controlled loads have been turned off but actual demand is still above the limit. When this occurs, you may reduce uncontrolled demand, increase the limit or turn the alarm off. By turning the alarm off, you may exceed the demand setting on your controller. Circuits On: These indicators, when lit, tell you which control circuits are on. A Circuits On indication does not necessarily mean that the controlled load is on but rather the load is free to go on if the thermostat calls for it. Decrease Key: This key operates in conjunction with the Demand Limit key (8), Display Bright key (9), and the Alarm Volume key (10) and is 7 8 9 10 11 12 13 14 used to decrease the functions controlled by these keys. Increase Key: This key operates in conjunction with the Demand Limit key (8), Display Bright key (9), and the Alarm Volume key (10) and is used to increase the functions controlled by these keys. Demand Limit Key: This key is used to set the demand limit and is used in conjunction with the Decrease key (6) or Increase key (7) and allows you to adjust the demand limit up or down to the level that best suits your particular energy requirements. Display Brightness Key: This key is used to adjust the display brightness and is used in conjunction with the Decrease key (6) or Increase key (7) to set the display brightness for the best visibility under existing lighting conditions. Alarm Volume Key: This key is used to control the alarm volume in conjunction with the Decrease key (6) or Increase key (7) and allows you to adjust alarm volume to meet various sound conditions. Display Key: This key allows you to change the mode display to instantaneous, average, peak demand limit, demand limit or clock modes. Reset Peak Key: This key allows you to reset the highest average peak demand since reset as described above. Once this peak is reset, the highest actual peak demand from the time of reset will be recorded for display. Control Panel Instruction: These instructions, printed on the front panel of the control panel, let you make all appropriate control settings. Circuit Assignments: This space is used to record the loads controlled by the 9312. You should record the loads controlled in the back of your installation manual that you received from the electrician. 4 5

System operation Please carefully read the following instructions concerning system operation, as they will enable you to maximize efficient energy use and minimize your electric bill. Step 1: Turning the unit on: The installing electrician should already have turned on your Demand Controller. If not, there should be a breaker in your electrical load center labeled Demand Controller or something similar. If this breaker is off, turn it on. If you can t find a breaker labeled Demand Controller, give us a call. Step 2: Setting your demand limit: Please refer to the Control/Display Unit pictured on page 3 for this and all succeeding steps. To set demand limit: 1. Press and hold the demand limit key (8). 2. Simultaneously press the decrease key (6) or increase key (7) until you reach the desired demand limit. The numbers in the kw Demand/Time display (2) will count down or up. 3. Release keys at the desired setting. Because of the way you are billed under the demand rate, you can adjust the kw demand limit on your Demand Controller to the changing seasons or when conditions warrant. For best results, you should set the lowest practical demand limit within the suggested range for your home, lifestyle or process. Typical demand limit ranges for an average all-electric home are listed on page 12 - Table 1. Step 3: Monitoring your actual demand: To select instantaneous, average, peak demand limit or clock readout of actual kw demand: 1. Press display key (11) once for each display change desired. 2. The instantaneous (Id), average (Ad), peak demand limit (Pd) or, clock (CL) indicating light will come on, and the mode display (2) will indicate the reading selected. 3. The kw demand/time display will show current value. Step 4: Reset Peak: This step is optional depending on the time interval that you want to record of your highest average peak. To reset peak: 1. Place mode display on the peak mode (Pd) (step 3). 2. Press and release peak reset key (12). A zero will be displayed in kw demand/time display (2). This value will increase to your maximum average peak demand starting from the time of reset. 6 7

Step 5: Adjusting Display Brightness: You can vary display brightness according to existing lighting conditions as follows: 1. Press and hold display bright key (9). 2. Simultaneously press decrease key (6) or increase key (7) until you reach the desired intensity. 3. Release keys at the desired display intensity. Step 6: Adjusting alarm volume: You can vary the alarm volume depending on your desired alarm level as follows: 1. Press and hold alarm volume key (10). 2. Simultaneously press decrease key (6) or increase key (7). The alarm will come on and beep about six times at each level. 3. Release keys at the desired volume. Note: If you want to turn off the alarm, hold the alarm volume and decrease keys down until the alarm stops. Step 7: If the alarm sounds: The alarm sounds and the reduce load indication (4) will come on when the 9312 has done all it can do to reduce your electrical demand but actual demand is still greater than the demand limit. In this situation, your demand limit may be unrealistically low for the level of comfort or appliance use you want. Loads with minimum on times (such as heat pump or air conditioning compressor) may cause the alarm to temporarily sound until the particular on time has elapsed. To silence the alarm, turn off some unnecessary appliance or load or, if necessary, increase the kw demand limit one number at a time until the alarm stops. If you choose to turn off an uncontrolled load, you may monitor your actual demand in the instantaneous mode to see the effect of each load on overall demand (see page 14 - Table 2). If the alarm sounds too often, or if heating or cooling levels are inadequate, you may have to increase your demand limit or change your load control strategy. Increase the kw demand limit by one and note whether that change solves the problem before increasing the limit further. It may take as long as an hour for the new level to be reached. Setting the demand limit There are no fixed demand settings that will be suitable for everyone. Your demand level to satisfy comfort, economy and convenience can vary. To find the best demand setting for you, we recommend that you start with the lowest kw that you think you will need during the present billing period. The unit has a demand limit setting range of 2 to 30 kw. If you need more energy to maintain comfort, just increase the kw but not more than one or two kw at a time. If, after a few hours, this is not enough, increase it by one or two more kw again until you are comfortable. It is important to remember that once the meter demand reading increases, its peak demand will not come down until the meter is reset to zero each month. Table 1 on page 12 shows typical residential kw values by month and gives you some guidelines for setting your demand limit by seasons. Hints for maximum savings When you want to decrease your settings (for example from 10 in February for heating to 8 in March for less heating), change it five days before we read your meter. When you want to increase your settings (for example, from 6 in May to 7 in June for air conditioning), change it after we read your meter. We read your meter on various days of the month, depending on the billing interval you happen to be on. You can check past bills to determine this date or give us a call. To help you set your demand limit based on appliance load, see Page 14 Table 2: Typical Residential Appliance Ratings or give us a call. You can increase your unit s effectiveness thus increasing your savings by avoiding turning on two or more major appliances at the same time. For example, don t use your electric range while other appliances are operating. Load shedding sequence When your power consumption average starts to approach the demand setting, the controller sheds the first load. If necessary, it will also shed additional loads to keep the average demand below the demand setting. The 8 9

controller sheds loads according to the priority strategy you selected. So, it uses the fixed priority strategy, the rotating strategy or a combination. The load shedding priority you select is based on the type of heating and cooling equipment and the design of your house. If you want, your dealer or an electrician can easily change the priorities. See the installation manual for an explanation about how to select the load control strategy, or give us a call. Control of clothes dryer The clothes dryer is usually one of the last circuits the load controller sheds. When the controller sheds the dryer, the dryer motor continues to tumble clothes, but the heating element is cut off. This may result in your clothes being slightly damp at the end of the drying period and may require longer drying times. If your dryer has a dampness control, we recommend that you use it. NOTE: If you can t restart your dryer each time the Demand Controller sheds, give us a call. The dryer may require a specific rewiring change to operate correctly. We ll help you to make sure that the rewiring is done properly. CAUTION: If you purchase a new dryer or if you move into a home with a Demand Controller already installed, your dryer may not work properly. Since dryers are not all wired the same, the dryer wires in the circuit breaker panel, may have to be reversed. like to change your load control strategy, refer to your installation manual, or give us a call. Service of heating/air conditioning and water heater When technicians service any electrical equipment controlled by the controller, make sure to tell them that you have a Demand Controller. You should also warn them not to disconnect the controller wiring or leave its power supply (circuit breaker) off. Otherwise, they may unknowingly disable your controller, which could result in a high electric bill. Incorrect rewiring of your controller s remote air conditioner or heat pump relays could damage your controller or air conditioner. The Energy Sentry Demand Controller simply acts as another switch on the water heater, dryer or heating/cooling equipment. It cannot cause damage or premature failure of the equipment it is connected to when installed and set correctly. Nor can it cause a higher electric bill than you would have had without a controller. When the power to the control unit is off at the breaker panel, power will be available to all controlled loads. Without power, the control unit cannot control your demand. The power must be restored to the controller. Contact us to check your meter to assure your demand did not exceed the set point while the control unit was off. 10 Load control strategies Your Demand Controller is the most versatile electric Demand Controller available on the market today. It offers a virtually unlimited number of load control strategies, allowing the controller to adapt to load requirements and your lifestyle. These strategies include the fixed priority strategy, the rotating strategy, and a wide range of combination strategies. In addition to these strategies, all circuits may be assigned minimum on and off times variable up to 15 minutes. This is designed specifically for heat pump and air conditioning compressors requiring time-delay protection. Even though this feature is available on all circuits, we recommend programming minimum on-off times for heat pumps and A/C units only. CHANGING LOAD CONTROL STRATEGIES: When your control unit was installed, the strategy most appropriate to your home s requirements was selected. If your home s requirements have since changed, or if you would If you need service Your Energy Sentry Demand Controller has been carefully assembled and tested at the factory. Only components with a high degree of reliability and long life have been used in its manufacture. In the event that a failure does occur, your control unit has been designed so household appliances will continue to function. The only difference during a failure of your Demand Controller is that there will be no demand control, and high demand peaks can occur. If a malfunction should occur, you may turn off the unit at the breaker labeled Demand Controller, in the load center (breaker panel). You may control your demand manually, if desired, to avoid unnecessary demand peaks as follows: 1. Heat or cool only those rooms that are occupied by keeping the thermostat set only while you are in each room. 2. When cooking meals, all heating or cooling zones should be turned off. 11

3. Avoid using appliances simultaneously. 4. You may monitor your highest demand peak on the utility meter to determine the effectiveness of manual control. 5. Make sure nothing else is connected to the Demand Controller circuit breaker, e.g. chest freezer, refrigerator, etc. Residential Demand Controller customer service program Although you own and operate the Demand Controller equipment, we offer a variety of Residential Demand Controller service programs to assist with instruction and maintenance of the unit: Instructional assistance: If you need additional information about your demand control equipment or instructional information, we ll send you information, at no cost. If you need further assistance give us a call. Service checks: We offer a free service check if you are not sure the unit is operating properly. One of our service technicians will test the unit to make sure that the equipment is working correctly and review with you any equipment malfunctions or operation procedures. Before you call, we recommend that you refer to your instruction manual. Standard warranty/repair: We will provide a warranty for the demand control equipment up to three years after the installation date. We ll order and replace any parts that are under warranty at no cost to you. Please allow at least two weeks for ordering parts. If you are not sure if your unit is under warranty, give us a call. Non-warranty repairs: Repairs that are not under the standard manufacturer s warranty guidelines are subject to a service labor charge, including parts. These service repair charges will vary based on the parts and labor to repair the equipment. Standard cost for service charge is on a perhour basis. Give us a call for details. Extended warranty: We also offer an extended warranty on demand control equipment. We recommend you opt for the extended warranty as a way to avoid costly repair bills. Call us for details. 12 13

Charts and tables What is a kilowatt? Demand limit and usage is measured by kilowatts. One kilowatt is equal to 1,000 watts. For example, if you have 10 100-watt light bulbs on at once, your demand is 1,000 watts or 1 kilowatt. If they remain on for one hour, the energy used is one kilowatt hour. TABLE 1: TYPICAL KW VALUES BY MONTH* Month January Winter (heating) area 7-10 kw February 7-10 March 6-9 April 5-7 May 5-6 June 5-6 July 5-6 August 5-6 September 5-7 October 6-8 November 7-9 December 7-10 *Settings will vary with lifestyle, home construction and climate. TABLE 2: TYPICAL RESIDENTIAL APPLIANCE RATINGS Stove 1.5 2.0 kw Room A/C 0.9 kw Self clean 5.0 kw Vacuum 0.7 kw Refrigerator 1.5 2.0 kw Blender 0.3 kw Dryer 4.5 6.0 kw Mixer 0.15 kw Freezer 1.5 2.0 kw Television 0.12 0.2 kw Water heater 3.0 6.0 kw Central A/C 3.0 8.0 kw Lighting 0.0 1.4 kw Hair dryer 1.0 kw Dishwasher 1.2 kw Toaster 1.1 kw Waffle iron 1.2 kw CHART A: BASEBOARD HEATED HOME Load control strategy: Combination fixed/rotate Priority Shed sequence Load Demand 1 (highest) Last Dryer (heating elements only) 5.5 kw 2 Second Water heater 4.5 kw 3 (lowest) First* Living room heat 3.5 kw 3 (lowest) First* Basement heat 4.0 kw 3 (lowest) First* Entry heat 1.5 kw 3 (lowest) First* Bedroom heat 2.0 kw 3 (lowest) First* Bedroom heat 2.0 kw 3 (lowest) First* Family room heat 3.0 kw *Note: Shedding sequence of rotating loads begins with the load that has been restored the longest. When all No. 3 priority loads are all shed, the No. 2 priority load is shed next, No. 1 priority load is shed last, if necessary. CHART B: TYPICAL HEAT PUMP/AIR CONDITIONER HOME Load control strategy: Fixed priority Priority Shed sequence Load Demand 1 (highest) Last Dryer (heating elements only) 5.5 kw 2 Seventh Compressor #1 3.0 7.0 kw 3 Sixth Compressor #2 3.0 7.0 kw 4 Fifth Water heater 4.5 kw 5 Fourth Strip heat #1 Electric furnace 6 Third Strip heat #2 Electric furnace 7 Second Strip heat #3 Electric furnace 8 (lowest) First Strip heat #4 Electric furnace 5.0 kw 5.0 kw 5.0 kw 5.0 kw 14 15

2016 2261_16 605-721-2687 www.blackhillsenergy.com/demand