Technical Guide Split Air-Conditioners Equipment Residential COS Series
TECHNICAL GUIDE SPLIT AIR-CONDITIONERS EQUIPMENT Thank you for choosing our products Note: Technical information contained in this catalog may be changed or updated by the manufacturer without notice for the benefit of the excellence, service or presentation of the products. No liability is assumed for the use of this information.
SPLIT AIR-CONDITIONERS EQUIPMENT SPLIT AIR-CONDITIONERS EQUIPMENT The term split equipment refers to a divided system composed of two units: an internal unit (evaporator) and an external one (condenser), separating the refrigeration cycle in two. Copper pipes through which the refrigerant gas circulates in its different states connect both units. The different physical properties characterizing the ambient air (usually temperature, relative humidity, purity and speed) require the control and regulation of the values in order to conditioning the environments in which we live. In we provide the necessary environmental comfort throughout the year with the right air-conditioning equipment. FEATURES Among the quality aspects offered by split air-conditioning systems are: Environmental comfort in temperature, humidity and purity Quick and easy installation Easy maintenance Adaptable to different environments A compact design, increasingly more aesthetic Favorable relationship between electricity consumption and unit capacity in W, which may represent significant energy cost savings Noise reduction increases environmental comfort Comfort, smooth performance and the ease of controlling the unit remotely The unit incorporates functions such as: programming by timer, overnight stop function to optimize the well-being in accordance with the variations of the human metabolism, the graduation of the air shutter direction for an optimized air distribution in the room, and also the regulation of the desired temperature NOMENCLATURE K S AC 1 09 CO S (X) (X) = Unit : i : internal o : external (S) = Version (CO) = Model (09) = Capacity in BTU (add 3 zeros) (1) = Voltage : 1 : 115/1/60 2 : 230/1/60 (AC) = Product : Air-Conditioner (S) = AC Type : Split (K) = Manufacturer : T h a n k y o u f o r c h o o s i n g o u r p r o d u c t s Rev. 00 01-15
SPLIT AIR-CONDITIONERS EQUIPMENT WHAT OFFERS KIELMANN S RESIDENTIAL ON-OFF SPLIT AC COD-SERIES Panel Manufactured by an integrated injection molding process, the panel provides a smooth surface and clean spaces Fan Blades A larger diameter of the cross flow blades creates an air flow volume of up to 780m 3 /h (12K) generating a large air volume and reducing noise Condenser The Golden Fin model is specially tested for preventing rust and corrosion and its compact design improves heat transfer Internally grooved copper tubes Internal grooves increase the inner surface of cooper tubes, improving heat transfer with a conductivity 20% - 30% greater than that of a smooth tube Compressor A well-known branded energetically efficient compressor which uses a permanent magnet motor offering a more effective performance Motor A brushless DC motor to ensure a soft startup and a more precise speed control Chipset circuit board Advanced control system of the chipset circuit board (main chip + DSP chip) Electronic expansion valve It inteligently and accurately adjusts the refrigerant flow for a precise temperature control T h a n k y o u f o r c h o o s i n g o u r p r o d u c t s Rev. 00 01-15
SPLIT AIR-CONDITIONERS EQUIPMENT SPECIFICATIONS Voltage: 115/1/60 or 230/1/60 Refrigerant R-22 World known compressor Very quiet tangential fan Aluminum foil with hydrophilic film Anticorrosive treatment Self-monitoring and self-diagnosis LED display/digital temperature display COMFORT Independently working dehumidifier, removing humidity in the area to be air-conditioned Turbo cooling function maximizes the airconditioning of the desired area Smart defrosting which makes the unit enter the defrost mode as fast as required, intelligently adjusting the heating time, thereby improving efficiency Air supply Air-Swing 360: the tridimensional design optimizes the conditioning of the ambient Cold shock protection: by gradually adjusting the emission of cold air during the regular operation, increasing the sensation of comfort EASY HANDLING Front panel easy to remove for cleaning Easy disassembly of the high efficiency filter for regular cleaning Timer for ON and OFF programming Auto-detection of erroneous operations by the unit HEALTH Automatic evaporator cleaning: when the evaporator requires being cleaned, the condensate flow increases, removing dust from the evaporator ENERGY SAVING Internally grooved cooper tubes increase the inner surface within the tubes, significantly improving thermal conductivity (20-30% compared to smooth tubes) Sleep mode: The equipment will automatically maintain a constant room temperature graduating (by increasing or decreasing) the operation, and it will turn off the unit after 5 hours of operation in order to save energy and maintain the comfort T h a n k y o u f o r c h o o s i n g o u r p r o d u c t s Rev. 00 01-15
SPLIT AIR-CONDITIONERS EQUIPMENT Compatibility Mode Model KSAC-109COS KSAC-112COS KSAC-209COS KSAC-212COS KSAC-218COS KSAC-224COS BTU 9,000 12,000 9,000 12,000 18,000 24,000 Rated Volt and Frequency V / Ph / Hz 115/1/60 115/1/60 220/1/60 220/1/60 220/1/60 220/1/60 Cooling Capacity W 2,500 3,200 2,500 3,200 5,100 6,100 Cooling Cooling Power Input W 920 1,220 940 1,190 1,980 2,360 Cooling Current Input A 8.40 11.00 4.50 5.70 9.47 11.30 EER w/w 2.72 2.66 2.62 2.69 2.58 2.58 Heating Capacity W Heating Heating Power Input Heating Current Input W A COP w/w Maximum Input Consumption W 1,200 1,500 1,250 1,500 2,400 3,100 Maximum Current 13.00 13.60 6.30 7.70 11.50 14.80 Model EH130M1C-1DZDU1 EH170M1B-1DZ1 44R212AE-FJS PH170G1C-3DZDU1 PH260M2AS-3KUU1 PH330G2C-3MUU1 Type Rotativo Rotativo Rotativo Rotativo Rotativo Rotativo Compressor Brand GMCC GMCC RECHI GMCC GMCC GMCC Capacity W 2,675 3,500 2,630 3,440 5,300 7,040 Power Input W 855 1,120 870 1,075 1,856 2,215 Model YDK-14-4D1 YDK-14-4D1 YDK-14-4C YDK-14-4C YDK-23-4D6 YDK-27-4D6 Fan Motor Power Input W 40 40 40 40 49 54 Capacity uf 2.5 2.5 1.2 1.2 1.2 1.8 Indoor Fan Speed RPM r/min 1,020/950/850 1,100/950/850 1,020/950/850 1,100/950/850 1,250/1,150/1,050 1,300/1,150/1,000 Indoor Indoor Fan Diameter Length mm φ97x583 φ97x583 φ97x583 φ97x583 φ98 707 φ102x707 Indoor Air Circulation m 3 /h 450/370/350 500/420/350 450/370/350 500/420/350 800/650/550 900/800/660 Indoor Noise Level db db(a) 31-39 32-40 31-39 29-40 37-44 42-46 Dimensions (L W H) mm 745 250 195 745 250 195 745 250 195 745 250 195 900 292 215 900 292 215 Packaging (L W H) mm 835 330 278 835 330 278 835 330 278 835 330 278 983 377 300 1,105 377 300 Net / Gross Weight 9/11 9/11 9/11 9/11 13/15 14/17,5 Model YDK-30-6B YDK-35-6H D YDK-30-6A YDK-35-6C H YDK-35-6C H YDK-40-6C 1 Fan Motor Power Input W 81 80 83 72 78 115 Capacity uf 6 8 2 2 2 3 Outdoor Fan Speed RPM r/min 890 910 890 900 900 870 Outdoor Outdoor Fan Diameter Length mm φ384 136 φ408 134 φ384 136 φ408 134 Φ408 134 Φ415 Outdoor Noise Level db db(a) 51 54 51 54 54 54 Dimensions (L W H) mm 700 225 500 715 235 540 700 225 500 715 235 540 795 255 540 850 295 605 Packaging (L W H) mm 825 320 550 851 335 600 825 320 550 851 345 600 920 335 595 995 415 690 Net / Gross Weight Kg 25/29 28/33 25/29 28/33 32/36 36/41 Refrigerant Type / Weight g R22/460g R22/540g R22/600 R22/500 R22/870 R22/1,150 Design Pressure (Hi / Low) Mpa 2,45/0,70 2,45/0,70 2,45/0,70 2,45/0,70 2,70/0,70 2,70/0,70 Refrigerant Piping / Connection Wiring Liquid Side/ Gas Side / Length mm φ6+φ9,52 3,500 φ6,0+φ12,7 3,500 φ6+φ9,52 3,500 φ6,0+φ12,7 3,500 φ6,0+φ12,7 4,000 φ9,52+φ15,88 5,000 Maximum Refrigerant Pipe Length / Maximum Difference in Level m 15/5 15/5 15/5 15/5 15/5 15/5 Applicable Area m 3 14 18 14 18 28 35 T h a n k y o u f o r c h o o s i n g o u r p r o d u c t s Rev. 00 01-15
Notes: SPLIT AIR-CONDITIONERS EQUIPMENT
TECHNICAL GUIDE