GE Evolve
The GE Evolve LED Medium Output Flood Light is our mid-lumen solution to efficiently illuminate building façade, flag poles, billboard signage and many more traditional flood applications. Designed to replace up to 250W PS and 2500W Metal alide flood lights, the provides significant operating cost benefits over the life of each fixture with reduced energy consumption and a long rated life that virtually eliminates ongoing maintenance expenses. Features: 70 CRI at 3000K, and 5000K L89@100K hrs per IES TM-21* Distributions: 6x5, 6x6, 7x6, 7x7, Type III, Spot 1-277 AC and 347-480 AC available DALI compatible Mounting options: Trunnion, Knuckle Slipfitter, & Knuckle Wall Mount UL/cUL listed, suitable for wet locations Complies with the material restrictions of RoS Applications: Building façade, flag poles, utility and industrial spaces, billboard signage, roadways, general site lighting, and many more traditional flood applications. NOTE: The Type III distribution is ideal for building facade and billboard signage. *S2 T3 distributions not L89 rated / Compatible with LightGrid Outdoor Wireless Control System Also available in Spot optical distribution as pictured here To learn more about GE Evolve LED Flood Lighting, go to: www.currentbyge.com 2
Typical Specifications: LED & Optical Evolve light engine consisting of reflective technology designed to optimize application efficiency. Impact resistant tempered flat glass protects the optics and minimizes dirt accumulation. Efficacy: Rated LPW 104-167 (See Table) LM-79 tests and reports in accordance with IESNA standards 70CRI at 3000K,, 5000K Distributions: 6x5, 6x6, 7x6, 7x7, Type III, Spot Electrical 1-277 AC and 347-480 AC available. System power factor is >90% and TD <%. ANSI C136.41 7-pin dimming receptacle, standard. Photo electric sensors (PE) available for all voltages and ordered seperately. Light Grid compatible Dimming: - 0-10 continuous dimming - DALI digital dimming (1-277) Surge Protection per ANSI C13615. 6k/3kA Standard 10k/5kA Optional k/10ka Optional (contact manufacturer for availability) Daintree compatible Motion Sensor (K1, S1 Mount Option) Ratings / UL cul listed, suitable for wet locations. IP66 otical enclosure per ANSI C136513 Temperature Rated C to +50 C Complies with the material restrictions of RoS Construction & Finish ousing: Die cast aluminum housing with slim design. Integral heat sink and light engine, ensuring maximum heat transfer and prolonged LED life. 3G vibration level per ANSI C136.3110. Paint: Corrosion resistant polyester powder painted, minimum 2.0 mil. thickness. Standard Colors: Dark Bronze, Black, White & Gray RAL & custom colors available Weight: 25 lbs. (11.34kg) Lumen Maintenance 01 Projected Lxx per IES TM-21 at 25 C for reference: OPTICAL CODES Mounting Option K K1=Knuckle Slipfitter for 1.9 in-2.3 in OD Tenon with wires exiting tenon. K2=Knuckle Slipfitter for 1.9 in-2.3 in OD Tenon, external 3ft #14/3 power cable Option S S1 = Knuckle Slipfitter for 1.9 in 3.0 in. OD Tenon with wires exiting tenon. S2 = Knuckle Slipfitter for 1.9 in 3.0 in. OD Tenon, with external 3ft #14/3 power cable Option 1=Knuckle Wall Mount with wires exiting tenon. Option T T1=Trunnion, with external 3ft #14/3 power cable. Warranty System Warranty: 5 Year Standard Accessories DISTRIBUTION Top & Side isor andal Shield Wire Guard Barn Door Assembly Project name Date Type AA, BB, CC T3 & S2 L93 L87 L75 OPTICAL CODES DISTRIBUTION LXX(10K)@OURS 25,000 R 50,000 R 100,000 R LXX(10K)@OURS 25,000 R 50,000 R 100,000 R AA, BB, CC, DD 65, 66, 76, & 77 L96 L93 L89 Note: Projected Lxx based on LM80 (10,000 hour testing). DOE Lighting Facts erification Testing Tolerances apply to initial luminous flux and lumen maintenance measurements. 3
Project name Date Type Ordering Number Logic E FM1 0 1 _ PROD. ID E = Evolve FM = Flood Medium 1 = Standard GEN. OLTAGE OPTIC CODE 01 = 1st Gen 0 = 1-277* 1 = 1 2 = 8 3 = 2 4 = 277 5 = 480 D = 347 = 347-480* *Not available with fusing AA = 5,000lm BB = 10,000lm CC = 15,000lm DD =,000lm DISTRIBUTION* CRI 65 = NEMA 6x5 7 = 70 (min) 66 = NEMA 6x6 76 = NEMA 7x6 77 = NEMA 7x7 (80 Wide Flood) T3 = Type 3/ Facade/Billboard* S2 = Spot* *Not available with optical code DD CCT DIMMING CONTROLS 30 = 3000K = 50 = 5000K A = ANSI C1 36.41 7-Pin Receptacle ++ D = No Receptacle, with external dimming 18/2 3ft cable + N = No PE receptacle & non-dimmable + P = ANSI 7-pin receptacle with external dimming 18/2 3ft cable ++ +Unrestricted aiming angle ++All units with option A and P have Restricted Aiming Angle. See page 8. A = No Control D = Shorting Cap* See below ordering logic for dimming PE and standard PE control options. Light Grid also available. Must order separately. * Can only be ordered with dimming option A or P MOUNTING K1 = Knuckle Slipfitter for 1.9 in-2.3 in. OD Tenon* S1 = Knuckle Slipfitter for 1.9 in 3.0 in. OD Tenon* K2 = Knuckle Slipfitter for 1.9 in-2.3 in OD Tenon with external 3ft #14/3 power cable S2 = Knuckle Slipfitter for 1.9 in 3.0 in. OD Tenon with external 3ft #14/3 power cable 1 = Knuckle Wall Mount* T1 = Trunnion with external 3ft #14/3 power cable. *Supplied with leads FINIS GRAY = Gray BLCK = Black DKBZ = Dark Bronze WTE = White OPTIONS F = Fusing < = Daintree enabled motion sensor# L = Tool-Less Entry < R = 10k/5kA Enhanced Surge Protection T = k/10ka Surge Protection > U = DALI Dimming +# = 3-Position Terminal Block XXX = Special Options + Compatible with LightGrid 2.0 nodes. # Not available in 347-480 Only available in mount K1 or S1 < Dimming and Fusing not available with Optical Code AA for distributions "T3" and "S2" > Check manufacturer for availability < NOTE: Options F, R, T, and not available with optical code AA with voltage 347-480 and distributions 65, 66, 76, and 77. OPTICAL CODE DIST. CODE *Dimming not available TYPICAL INITIAL OPTICAL LUMENS DIST./NEMA / CLASS 3000K 5000K TYPICAL SYSTEM WATTAGE 1-277 TYPICAL SYSTEM WATTAGE 347-480 3000K 1-277 347-480 IES FILE NUMBER AA 77 7X7 4900 5000 30 32 01_AA77730_-1-277.IES 01_AA77730_-347-480.IES 01_AA777_-1-277.IES 01_AA777_-347-480.IES 01_AA77750_-1-277.IES 01_AA77750_-347-480.IES BB 77 7X7 9800 10000 64 64 01_BB77730.IES 01_BB777.IES 01_BB77750.IES CC 77 7X7 14700 15000 96 96 01_CC77730.IES 01_CC777.IES 01_CC77750.IES DD 77 7X7 0 900 146 146 01_DD77730.IES 01_DD777 IES 01_DD77750.IES AA 76 7X6 4700 4800 30 32 01_AA76730_-1-277.IES 01_AA76730_-347-480.IES 01_AA767_-1-277.IES 01_AA767_-347-480.IES 01_AA76750_-1-277.IES 01_AA76750_-347-480.IES BB 76 7X6 9500 9700 64 64 01_BB76730.IES 01_BB767.IES 01_BB76750.IES CC 76 7X6 14300 1 96 96 01_CC76730.IES 01_CC767.IES 01_CC76750.IES DD 76 7X6 19900 0 146 146 01_DD76730.IES 01_DD767.IES 01_DD76750.IES AA 66 6X6 4700 4800 30 32 01_AA66730_-1-277.IES 01_AA66730_-347-480.IES 01_AA667_-1-277.IES 01_AA667_-347-480.IES 01_AA66750_-1-277.IES 01_AA66750_-347-480.IES BB 66 6X6 90 90 64 64 01_BB66730.IES 01_BB667.IES 01_BB66750.IES CC 66 6X6 140 14500 96 96 01_CC66730.IES 01_CC667.IES 01_CC66750.IES DD 66 6X6 19700 0 146 146 01_DD66730.IES 01_DD667.IES 01_DD66750.IES AA 65 6X5 40 4500 30 32 01_AA65730_-1-277.IES 01_AA65730_-347-480.IES 01_AA657_-1-277.IES 01_AA657_-347-480.IES 01_AA65750_-1-277.IES 01_AA65750_-347-480.IES BB 65 6X5 8900 9100 64 64 01_BB65730.IES 01_BB657.IES 01_BB65750.IES CC 65 6X5 130 13700 96 96 01_CC65730.IES 01_CC657.IES 01_CC65750.IES DD 65 6X5 18700 19100 146 146 01_DD65730.IES 01_DD657.IES 01_DD65750.IES AA* T3 Type 3 60 60 50 50 01_AAT3730.IES 01_AAT37.IES 01_AAT3750.IES BB T3 Type 3 100 10500 88 88 01_BBT3730.IES 01_BBT37.IES 01_BBT3750.IES CC T3 Type 3 14700 15000 141 141 01_CCT3730.IES 01_CCT37.IES 01_CCT3750.IES AA* S2 Spot 7100 7300 50 50 01_AAS2730.IES 01_AAS27.IES 01_AAS2750.IES BB S2 Spot 11300 110 88 88 01_BBS2730.IES 01_BBS27.IES 01_BBS2750.IES CC S2 Spot 16300 16700 141 141 01_CCS2730.IES 01_CCS27.IES 01_CCS2750.IES 5000K 4
Photometrics: Evolve LED Flood Light () NEMA 6x5 14493 10870 7246 1449.3 19,100 Lumens 01_DD657_- 3623 ertical Angles 7246.498 Grid Distance in Units of Mounting eight at 35 Tilt is 45. Initial Footcandle alues at Grade ertical angle of Max Cd. at -2 orizontal angle of Max Cd. at 2 orizontal Angles NEMA 6x6 10903 8177 5451 10909 5451.452,0 Lumens 01_DD667_- 2726 ertical Angles Grid Distance in Units of Mounting eight at 35 Tilt is 45. Initial Footcandle alues at Grade ertical angle of Max Cd. at -5 orizontal angle of Max Cd. at 2 orizontal Angles NEMA 7x6 10128 7596 5064 1012.846 506429,0 Lumens 01_DD767_- 2532 ertical Angles Grid Distance in Units of Mounting eight at 35 Tilt is 45. Initial Footcandle alues at Grade ertical angle of Max Cd. at -2 orizontal angle of Max Cd. at 2 orizontal Angles 5
Photometrics: Evolve LED Flood Light () NEMA 7x7 9199 6899 4599 4599.413 919.8826,900 Lumens 01_DD777_- 2300 ertical Angles Grid Distance in Units of Mounting eight at 35 Tilt is 45. Initial Footcandle alues at Grade ertical angle of Max Cd. at -7 orizontal angle of Max Cd. at 5 orizontal Angles TYPE lll FACADE/BILLBOARD 117 86 54 53.745 11.749 2802 15,000 Lumens 01_CCT37_- ertical Angles Grid Distance in Units of Mounting eight at 35 Tilt is 25. Initial Footcandle alues at Grade ertical angle of Max Cd. at 47 orizontal angle of Max Cd. at 15 orizontal Angles SPOT 24666 18499 12333 246686 16,700 Lumens 01_CCS27_- 6166 ertical Angles 0 12332.93 Grid Distance in Units of Mounting eight at 35 Tilt is 45. Initial Footcandle alues at Grade ertical angle of Max Cd. at -5 orizontal angle of Max Cd. at 0 orizontal Angles 6
GE Evolve Product Dimensions: Evolve LED Flood Light () 547in [130.74mm] TRUNNION MOUNT 547in [130.74mm] R1098in [R259.02mm] R1098in 15.7in [R259.02mm] [3999mm] o.875in [ o223mm] 1875in [471.80mm] 15.7in [3999mm] 843in [9.38mm] 1875in [471.80mm] 1700in [434.34mm] 2.000in [50.80mm] 1700in [434.34mm] o31in [ o13.49mm] 1.875in [47.63mm] o31in [ o13.49mm] 3.750in [955mm] 843in [9.38mm] 2.000in [50.80mm] FRONT IEW KNUCKLE SLIPFITTER MOUNT o.875in [ o223mm] 1.875in [47.63mm] 3.750in [955mm] SIDE IEW 16.369in [415.76mm] 16.369in [415.76mm] R1737in [R437.81mm] 15.7in R1737in [3999mm] [R437.81mm] 23.980in [90mm] 15.7in [3999mm] 23.980in [90mm] Wiring Access FRONT IEW 6.771in [171.99mm] 6.771in [171.99mm] Wiring Access Slipfitter Mount with Sensor Slipfitter Mount with Sensor SIDE IEW KNUCKLE WALL MOUNT R1737in [R437.81mm] Bolt Pattern 1946in [486.32mm] 15.7in [3999mm] o31in o13.49mm] o.438in [ o113mm] 2.876in [73.05mm] 4.376in [1115mm] Wiring Access FRONT IEW 1.938in [491mm] SIDE IEW 7
Product Dimensions: Evolve LED Flood Light () - PE Aiming Restrictions Trunnion Mount Knuckle Slipfitter Mount Knuckle Wall Mount Aiming from -30 to + Off orizon Allow clearance for PE or controls MAX Off orizon Aiming from -30 to + Off orizon DATA Approximate Weight: 25 lbs. (11.34 kg) Effective Projected Area: - 0 aim (vertical glass) 1.96 sq. ft. - 45 aim 12 sq. ft. - Side profile (all aims) 0.73 sq. ft. - 90 (downward) aim 0.79 sq. ft. - Accessories Top And Side isor Ordering Logic: TSGRAY-EFM TSBLCK-EFM TSDKBZ-EFM TSWTE-EFM andal Shield Ordering Logic: AN-EFM Wire Guard Ordering Logic: WG-EFM Barn Doors Ordering Logic: BDAGRAY-EFM BDABLCK-EFM BDADKBZ-EFM BDAWTE-EFM 8
Accessories Evolve LED Flood Light () PE Accessories (to be ordered separately) SAP Number Part Number Description 93029237 PED-M-LED-7 ANSI C136.41 Dimming PE, 1-277 93029238 PED-347-LED-7 ANSI C136.41 Dimming PE, 347 93029239 PED-480-LED-7 ANSI C136.41 Dimming PE, 480 SAP Number Part Number Description 28299 PEC0TL STANDARD 1-277 28294 PEC5TL STANDARD 480 80436 PECDTL STANDARD 347 73251 SCCL-PECTL Shorting cap -Motion Sensing Option Intended for applications, between 15-30 ft. mounting height. (47-94m). For mounting heights exceeding 30 ft., remote mounted sensors are recommended. Provides a coverage area radius for walking motion of 15 ft. (47m). Provides 300 of coverage (~ is blocked by the knuckle). Standard factory settings: 10% output when unoccupied, 100% output occupied. Knuckle mounted PE Sensor. 10 minute post-occupancy time delay, 5 minute dimming ramp-down. Fixture power increase of 1W expected with sensor use. Slipfitter Mount with Sensor Note: Standard options may be reprogrammed in the field. Reprogramming instructions included in product shipment. Sensor Pattern Sensing Pattern 30 ft. Mounting eight All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. 18 GE. www.currentbyge.com OLP3134 (Rev 01/11/18) 9