technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

Similar documents
technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems Indoor Units FBQ-C7VEB

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems Indoor Units FCQ-C8VEB

TABLE OF CONTENTS ERSQ-AAY1

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

EEDEN technical data ERHQ AA. Altherma. Altherma

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

TABLE OF CONTENTS RMXS-E8V1B

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioners. Technical Data FTXS-G

Daikin air conditioners for your home, shops, restaurants and offices

EEDEN technical data ERHQ AA

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ B8W1B Split Sky Air

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

Air Conditioning Technical Data RZAG-MV1

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

TABLE OF CONTENTS ERHQ BAV3

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Concealed ceiling unit with medium ESP

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

Air Conditioning Technical Data RZASG-MV1

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

technical data air conditioning systems RZQ C7Y1B Split Sky Air

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air conditioners, heating & cooling for shops,restaurants and offices

Daikin air conditioners for your home

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioners Technical Data

Digital Inverter 4 series 8 & 10HP

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Air Conditioners. Technical Data RZQG-L

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

Air Conditioners Technical Data

Concealed ceiling units

Air conditioners, heating & cooling for the retailmarket and offices

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioners Technical Data

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

EEDEN technical data EKRTR. Altherma. Altherma

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

AIR CONDITIONERS, HEATING & COOLING for your home

Air Conditioning Technical Data AZAS-MY1

SiE Service Manual. Split System Air Conditioners SkyAir R-407C Super Inverter 70 D Series. [Applied Models] SkyAir : Inverter Heat Pump

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

DESIGN & TECHNICAL MANUAL

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioners Heating & Cooling

DESIGN & TECHNICAL MANUAL

Air Conditioner SVC MANUAL(Exploded View)

Daikin air conditioners for shops, restaurant and offices

DESIGN & TECHNICAL MANUAL

technical data Fan coil unit FWB small duct unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Heating. Technical Data EEDEN ERRQ-AY1

for small rooms in multi application

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

EDUS F4. FXMQ-PBVJU Ceiling Mounted Duct Type

Daikin air conditioners for your home

for the retail market, hotels, restaurants and offices

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

MUH-24RV - MSH-30RV -

w w w. d a i k i n. e u ATXS-E

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Transcription:

technical data FH(Y)B-FK7 Concealed Ceiling Unit air conditioning systems Split Sky ir

Split - Sky ir ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQ for its Quality Management System in accordance with the ISO001 standard. ISO001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE02-1/1 10/2002 Prepared in Belgium by Goekint Graphics

TBLE OF CONTENTS FH(Y)B-FK7 1 Features... 2 2 Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications Electrical specifications 3 Dimensional drawings... 4 Piping diagrams... 12 5 Wiring diagrams... 13 6 Sound level... 15 Sound level data Sound pressure spectrum 7 Fan characteristics... 17 8 ir flow patterns... 21 ccessories... 23 Optional accessories 10 Control systems... 25 11 Centre of gravity... 27 12 Safety device settings... 27 13 Installation... 28 For capacity tables, please refer to part II: Outdoor units Note: R-22 cooling only models, which are produced after 01/07/2002, cannot be sold inside countries that follow the European Regulation n 2037/2000 EE of 2/0/2000. Split - Sky ir Indoor Units 1

1 Features Stylish and compact + Blends unobtrusively with any interior décor + Leaves maximum floor and wall space for furniture, decoration and fittings + Fits flush into each ceiling + Extremely quiet in operation both indoors and outdoors + The position of the individual air discharge grilles can be altered, enabling a uniform temperature, even in irregularly shaped rooms: L-shaped room, U-shaped room, long room Easy to install + For equal distribution in larger rooms, up to 4 indoor units can be connected to 1 outdoor. They are operated from 1 remote control. + Up to 7 indoor units can be connected to 1 Multi outdoor unit. ll indoor units are individually controllable with remote control and do not need to be installed in the same room. Easy control at your fingertips + The wired remote control has a programmable timer + Centralised control of several units can be achieved via 3 wired controls Centralised remote control Unified ON/OFF control Schedule timer 1 1 3 8 q x 6 Optional Optional FHYB 2 steps 5 ) z ( 6 4 FHYB35-125 FHB35-60 FHYB35-71 2 Split - Sky ir Indoor Units

2 Specifications NOMINL CPCITY and NOMINL INPUT For indoor units only: INDOOR UNITS FHB35FK7V15 FHB45FK7V15 FHB60FK7V15 NOMINL INPUT Cooling kw - - - For combination indoor units + outdoor units: INDOOR UNITS FHB35FK7V15 FHB45FK7V15 FHB60FK7V15 OUTDOOR UNITS R35DC7V115 R45DC7V115/W115 R60F7V15/W15 NOMINL CPCITY (2) Cooling (1) kw 3.5 5.30/5.30 6.50/6.50 NOMINL INPUT Cooling kw 1.36 2.17/2.17 2.42/2.42 TECHNICL SPECIFICTIONS For indoor units only: INDOOR UNITS FHB35FK7V15 FHB45FK7V15 FHB60FK7V15 DIMENSIONS Unit H mm 300 300 300 W mm 700 700 1,000 D mm 800 800 800 Decoration panel H mm 55 55 55 W mm 880 880 1,100 D mm 500 500 500 WEIGHT Unit kg 30 31 41 Decoration panel kg 3.5 3.5 4.5 MTERIL Decoration panel Unpainted galvanised steel plate COLOUR Decoration panel White SOUND LEVEL Sound pressure (3) high db 33 33 34 low db 2 2 30 Sound power (4) db 52 53 60 FN ir flow rate high m 3 /min 11.5 14 17 low m 3 /min 10 13 Speed steps 2 steps Type Sirocco fan Qty x model 1 x D18H2H1V1 1 x D18H2H1V1 1 x 2D18H2H1V1 Qty x motor output W 1 x 65 1 x 85 1 x 110 Drive Direct drive External static pressure (5) Pa 88-4-20 88-4-20 88-4-20 HET EXCHNGER Type Cross fin coil (waffle louver fins & Hi-X tubes) Rows x stages x fin pitch mm 3 x 14 x 1.75 3 x 14 x 1.75 3 x 14 x 1.75 Face area m 2 0.132 0.132 0.221 IR FILTER Resin net (with mold resistant) TEMPERTURE CONTROL Computerised control PIPING CONNECTIONS liquid mm φ6.4 φ6.4 φ6.4 gas mm φ12.7 φ15. φ15. drain mm I.D. φ25 I.D. φ25 I.D. φ25 drain mm O.D. φ32 O.D. φ32 O.D. φ32 INSULTION MTERIL Heat insulation tape Both liquid and gas pipes 2 For outdoor units Pair application See chapter R Multi model application See chapter M 3TW22041-1 Split - Sky ir Indoor Units 3

2 Specifications NOMINL CPCITY and NOMINL INPUT For indoor units only: INDOOR UNITS FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 NOMINL INPUT Cooling kw - - - For combination indoor units + outdoor units: INDOOR UNITS FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 OUTDOOR UNITS R71B7V15/W15 R100B7V15/W15 R125B7W15 NOMINL CPCITY (2) Cooling (1) kw 7.20/7.20 10.50/10.50 12.40 NOMINL INPUT Cooling kw 3.10/2.0 3.80/3.50 4.60 2 TECHNICL SPECIFICTIONS For indoor units only: INDOOR UNITS FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 DIMENSIONS Unit H mm 300 300 300 W mm 1,000 1,400 1,400 D mm 800 800 800 Decoration panel H mm 55 55 55 W mm 1,100 1,500 1,500 D mm 500 500 500 WEIGHT Unit kg 41 51 52 Decoration panel kg 4.5 6.5 6.5 MTERIL Decoration panel Unpainted galvanised steel plate COLOUR Decoration panel White SOUND LEVEL (2) Sound pressure (3) high db 34 36 38 low db 30 31 32 Sound power (4) db 60 62 63 FN ir flow rate high m 3 /min 1 27 35 low m 3 /min 14 20 24 Speed steps 2 steps Type Sirocco fan Qty x model 1 x 2D18H2J1V1 1 x 3D18H2N1V1 1 x 3D18H2P1V1 Qty x motor output W 1 x 125 1 x 135 1 x 225 Drive Direct drive External static pressure (5) Pa 863-480.5 863-480.5 863-480.5 HET EXCHNGER Type Cross fin coil (waffle louver fins & Hi-X tubes) Rows x stages x fin pitch mm 3 x 14 x 1.75 3 x 14 x 1.75 3 x 14 x 1.75 Face area m 2 0,221 0,338 0,338 IR FILTER Resin net (with mold resistant) TEMPERTURE CONTROL Computerised control PIPING CONNECTIONS liquid mm φ.5 φ.5 φ.5 gas mm φ15. φ1.1 φ1.1 drain mm I.D. φ25 I.D. φ25 I.D. φ25 drain mm O.D. φ32 O.D. φ32 O.D. φ32 INSULTION MTERIL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter R 3TW22041-1 4 Split - Sky ir Indoor Units

2 Specifications ELECTRICL SPECIFICTIONS For indoor units only: FHB35FK7V15 FHB45FK7V15 FHB60FK7V15 CURRENT Nominal running current Max. running current See chapter R: Electrical data For combination indoor units + outdoor units: FHB35FK7V15 FHB45FK7V15 FHB60FK7V15 R35DC7V115 R45DC7V115/W115 R60F7V15/W15 CURRENT Nominal running current 6.1 10.8/4.4 10.4/5.2 Maximum running current See chapter R: Electrical data 13.5/6.7 Starting current 26 44/1 See chapter R: Electrical data For indoor units only: FHB35FK7V15 FHB45FK7V15 FHB60FK7V15 POWER SUPPLY V1 V1 V1 NOMINL DISTRIBUTION SYSTEM Phase 1 1 1 VOLTGE Frequency Hz 50 50 50 Voltage V 230 230 230 ELECTRICL SPECIFICTIONS For indoor units only: FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 CURRENT Nominal running current Max. running current See chapter R: Electrical data For combination indoor units + outdoor units: FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 R71B7V15/W15 R100B7V15/W15 R125B7W15 CURRENT Nominal running current Maximum running current See chapter R: Electrical data Starting current 2 For indoor units only: FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 POWER SUPPLY V1 V1 V1 NOMINL DISTRIBUTION Phase 1 1 1 SYSTEM VOLTGE Frequency Hz 50 50 50 Voltage V 230 230 230 NOTES 1 Nominal cooling capacities are based on: indoor temperature 27 CDB/1 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter. 4 The sound power level is an absolute value indicating the power which a sound source generates. 5 The external static pressure is changeable by programming on the remote control. This pressure means High static pressure - Standard. Split - Sky ir Indoor Units 5

2 Specifications NOMINL CPCITY, CPCITY STEPS and NOMINL INPUT For indoor units only: INDOOR UNITS FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 NOMINL INPUT Cooling kw - - - Heating kw - - - For combination indoor units + outdoor units: INDOOR UNITS FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 OUTDOOR UNITS RY35D7V1 RY45DB7V1 RY60F7V1 NOMINL CPCITY (3) Cooling (1) kw 3.80 4.45 6.15 Heating (2) kw 4.20 5.60 7.15 NOMINL INPUT Cooling kw 1.64 2.15 2.51 Heating kw 1.45 1.6 2.40 2 TECHNICL SPECIFICTIONS For indoor units only: INDOOR UNITS FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 DIMENSIONS Unit H mm 300 300 300 W mm 700 700 1,000 D mm 800 800 800 Decoration panel H mm 55 55 55 W mm 880 880 1,100 D mm 500 500 500 WEIGHT Unit kg 30 31 41 Decoration panel kg 3.5 3.5 4.5 MTERIL Decoration panel Unpainted galvanised steel plate COLOUR Decoration panel White SOUND LEVEL Sound pressure high db 33 33 34 (cooling/heating) (4) low db 2 2 30 Sound power high db 52 53 60 (cooling/heating) (5) FN ir flow rate (cooling/heating) high m 3 /min 11.5 14 17 low m 3 /min 10 13 Speed (cooling/heating) steps 2 steps Type Sirocco fan Qty x model 1 x D18H2H1V1 1 x D18H2J1V1 1 x 2D18H2H1V1 Qty x motor output W 1 x 65 1 x 85 1 x 110 Drive Direct drive External static pressure (6) Pa 88-4-20 88-4-20 88-4-20 HET EXCHNGER Type Cross fin coil (waffle louver fins & Hi-X tubes) Rows x stages x fin pitch mm 3 x 14 x 1.75 3 x 14 x 1.75 3 x 14 x 1.75 Face area m 2 0.132 0.132 0.221 IR FILTER Resin net (with mold resistant) TEMPERTURE CONTROL Computerised control PIPING CONNECTIONS liquid mm φ6.4 φ6.4 φ.5 gas mm φ12.7 φ12.7 φ15. drain mm I.D. φ25 I.D. φ25 I.D.φ25 drain mm O.D. φ32 O.D. φ32 O.D. φ32 INSULTION MTERIL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter R(E)Y 3TW22041-2 6 Split - Sky ir Indoor Units

2 Specifications NOMINL CPCITY and NOMINL INPUT For indoor units only: INDOOR UNITS FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 NOMINL INPUT Cooling kw - - - Heating kw - - - For combination indoor units + outdoor units: INDOOR UNITS FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 OUTDOOR UNITS RY71B7V1/W1 RY100B7V1/W1 RY125B7W1 NOMINL CPCITY (3) Cooling (1) kw 7.20/7.20 10.00/10.00 12.40 Heating (2) kw 8.60/8.60 11.60/11.60 15.20 NOMINL INPUT Cooling kw 3.20/3.10 4.00/3.0 4.50 Heating kw 3.150/3.10 4.30/4.10 4.80 TECHNICL SPECIFICTIONS For indoor units only: INDOOR UNITS FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 DIMENSIONS Unit H mm 300 300 300 W mm 1,000 1,400 1,400 D mm 800 800 800 Decoration panel H mm 55 55 55 W mm 1,100 1,500 1,500 D mm 500 500 500 WEIGHT Unit kg 41 51 52 Decoration panel kg 4.5 6.5 6.5 MTERIL Decoration panel Unpainted galvanised steel plate COLOUR Decoration panel White SOUND LEVEL Sound pressure high db 34/34 36/36 38/38 (cooling/heating) (4) low db 30/30 31/31 32/32 Sound power high db 60/60 62/62 63/63 (cooling/heating) (5) FN ir flow rate (cooling/heating) high m 3 /min 1/1 27/27 35/35 low m 3 /min 14/14 20/20 24/24 Speed (cooling/heating) steps 2 steps Type Sirocco fan Qty x model 1 x 2D18H2J1V1 1 x 3D18H2N1V1 1 x 3D18H2P1V1 Qty x motor output W 1 x 125 1 x 135 1 x 225 Drive Direct drive External static pressure (6-7) Pa 88-4-20 88-4 88-4 HET EXCHNGER Type Cross fin coil (waffle louver fins & Hi-X tubes) Rows x stages x fin pitch mm 3 x 14 x 1,75 3 x 14 x 1,75 3 x 14 x 1,75 Face area m 2 0.221 0.338 0.338 IR FILTER Resin net (with mold resistant) TEMPERTURE CONTROL Computerised control PIPING CONNECTIONS liquid mm φ.5 φ.5 φ.5 gas mm φ15. φ1.1 φ1.1 drain mm I.D. φ25 I.D. φ25 I.D. φ25 drain mm O.D. φ32 O.D. φ32 O.D. φ32 INSULTION MTERIL Heat insulation tape Both liquid and gas pipes 2 For outdoor units Pair application See chapter R(E)Y 3TW22041-2 Split - Sky ir Indoor Units 7

2 Specifications ELECTRICL SPECIFICTIONS For indoor units only: FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 CURRENT Nominal running current cooling heating Starting current cooling heating See chapter R(E)Y: Electrical data For combination indoor units + outdoor units: FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 RY35D7V1 RY45DB7V1 RY60F7V1 CURRENT Nominal running current cooling 6.8 8. 10. heating 6.3 8.1 10.7 Maximum running current cooling 8.8 11.5 13.5 heating 8.8 11.5 13.5 Starting current cooling 35 3 53 heating 35 3 53 2 For indoor units only: FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 POWER SUPPLY V1 V1 V1 NOMINL DISTRIBUTION Phase 1 1 1 SYSTEM VOLTGE Frequency Hz 50 50 50 Voltage V 230 230 230 ELECTRICL SPECIFICTIONS For indoor units only: FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 CURRENT Nominal running current cooling heating Max. running current cooling heating See chapter R(E)Y: Electrical data For combination indoor units + outdoor units: FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 RY71B7V1/W1 RY100B7V1/W1 RY125B7W1 CURRENT Nominal running current cooling heating Maximum running current cooling heating See chapter R(E)Y: Electrical data Starting current cooling heating For indoor units only: FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 POWER SUPPLY V1 V1 V1 NOMINL DISTRIBUTION Phase 1 1 1 SYSTEM VOLTGE Frequency Hz 50 50 50 Voltage V 230 230 230 NOTES 1 Nominal cooling capacities are based on: indoor temperature 27 CDB/1 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20 CDB* outdoor temperature: 7 CDB/6 CWB * refrigerant piping length: 7.5m * level difference: 0m 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure values are mentioned for a unit installed with rear suction. 5 The sound power level is an absolute value indicating the power which a sound source generates. For measuring conditions: please refer to item 6 of this chapter. 6 The external static pressure is changeable by programming on the remote control. This pressure means High static pressure - Standard - Low static pressure. 7 The external static pressure is changeable by programming on the remote control. This pressure means High static pressure - Standard. 8 Split - Sky ir Indoor Units

3 Dimensional drawings FH(Y)B35-45FK7 750 (Suspension position) view B view 55 (ir suction panel center) 160 P.C.D. Fresh air intake position Suspension bolt (Knock out hole) 350 or more (Installation space) 300 mm or more (Service space) (On circumference) C view Notes: 1. Refer to dimensional drawing for installing optional accessories when installing optional accessories. 2. The required ceiling depth varies according to configuration of the specific system. 3. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the filter installation method drawing) 1 Liquid pipe connection J Flare connection 2 Gas pipe connectionj B Flare connection 3 Drain pipe connection VP25 (O.D.J32, I.D.J25) VP25 (I.D. J 32, I.D. J 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole (I.D. J 32, I.D. J 25) 7 ir filter 8 ir suction side ir discharge side 10 Name plate Model B FHB35FK7 6.35 12.70 FHYB35FK7 6.35 12.70 FHB45FK7 6.35 15.0 FHYB45FK7 6.35 12.70 3TW22224-1B 3 FH(Y)B35-45FK7 With canvas 750 (Suspension position) view Suspension bolt 55 (ir suction panel center) (Knock out hole) Fresh air intake position 465 mm or more 630 (Suspension position) (Installation space) (On circumference) 300 mm or more (Service space) view C view B 55 (ir suction panel center) 500 760 (Ceiling opening) 350 or more (Installation space) Notes: 1. Refer to dimensional drawing for installing optional accessories when installing optional accessories. 2. Optional decoration panel: BYBS45DJW1 (light ivory white 10Y/0.5). 3. The required ceiling depth varies according to configuration of the specific system view C 1 Liquid pipe connection J Flare connection 2 Gas pipe connectionj B Flare connection 3 Drain pipe connection VP25 (I.D. J 32, I.D. J 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (O.D.J32, I.D.J25) 7 ir filter 8 ir suction side ir discharge side 10 Name plate Model B FHB35FK7 6.35 12.70 FHYB35FK7 6.35 12.70 FHB45FK7 6.35 15.0 FHYB45FK7 6.35 12.70 3TW22224-2B Split - Sky ir Indoor Units

3 Dimensional drawings FH(Y)B60-71FK7 750 (Suspension position) view B view Suspension bolt (Knock out hole) 350 or more (Installation space) 630 (Suspension position) 55 (ir suction panel center) Fresh air intake position 500 mm or more (Service space) (On circumference) C view 3 Notes: 1. Refer to dimensional drawing for installing optional accessories when installing optional accessories. 2. The required ceiling depth varies according to configuration of the specific system. 3. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the filter installation method drawing) 1 Liquid pipe connection J Flare connection 2 Gas pipe connectionj B Flare connection 3 Drain pipe connection VP25 (I.D. J 32, I.D. J 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole (I.D. J 32, I.D. J 25) 7 ir filter 8 ir suction side ir discharge side 10 Name plate Model B FHB60 6.35 15.0 FHYB60.52 15.0 FHYB71.52 15.0 3TW22244-1B FH(Y)B60-71FK7 With canvas 630 (Suspension position) 1050 (Suspension position) view Suspension bolt 55 (ir suction panel center) (Knock out hole) Fresh air intake position 465 mm or more (Installation space) (On circumference) 300 mm or more (Service space) With canvas 55 (ir suction panel center) B view 1060 (Ceiling opening) Notes: 1. Refer to dimensional drawing for installing optional accessories when installing optional accessories. 2. Optional decoration panel: BYBS71DJW1 (light ivory white 10Y/0.5) 3. The required ceiling depth varies according to configuration of the specific system. (Ceiling opening) With flange 1 Liquid pipe connection J Flare connection 2 Gas pipe connectionj B Flare connection 3 Drain pipe connection VP25 (I.D. J 32, I.D. J 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole (VP25, I.D. J 32, I.D. J 25) 7 ir filter 8 ir suction side ir discharge side 10 Name plate 350 or more (Installation space) Model B FHYB71.52 15.0 3TW22244-2B 10 Split - Sky ir Indoor Units

3 Dimensional drawings FHYB100-125FK7 1450 (Suspension position) view B view Suspension bolt (Knock out hole) 350 or more (Installation space) 630 (Suspension position) 55 (ir suction panel center) Fresh air intake position 500 mm or more (Service space) (On circumference) C view Notes: 1. Refer to dimensional drawing for installing optional accessories when installing optional accessories. 2. The required ceiling depth varies according to configuration of the specific system. 3. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the filter installation method drawing) 1 Liquid pipe connection J Flare connection 2 Gas pipe connectionj B Flare connection 3 Drain pipe connection VP25 (I.D. J 32, I.D. J 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole (I.D. J 32, I.D. J 25) 7 ir filter 8 ir suction side ir discharge side 10 Name plate Model B FHYB100.52 1.10 FHYB125.52 1.10 3TW22254-1B 3 FHYB100-125FK7 With canvas 630 (Suspension position) 1450 (Suspension position) view Suspension bolt 55 (ir suction panel center) (Knock out hole) Fresh air intake position 465 mm or more (Installation space) (On circumference) 300 mm or more (Service space) view C view B 55 (ir suction panel center) 500 1460 (Ceiling opening) 350 or more (Installation space) Notes: 1. Refer to dimensional drawing for installing optional accessories when installing optional accessories. 2. Optional decoration panel: BYBS45DJW1 (light ivory white 10Y/0.5). 3. The required ceiling depth varies according to configuration of the specific system view C 1 Liquid pipe connection J Flare connection 2 Gas pipe connectionj B Flare connection 3 Drain pipe connection VP25 (I.D. J 32, I.D. J 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (O.D.J32, I.D.J25) 7 ir filter 8 ir suction side ir discharge side 10 Name plate Model B FHYB100.52 1.10 FHYB125.52 1.10 3TW22254-2B Split - Sky ir Indoor Units 11

4 Piping diagrams FH(Y)B-FK7 Cooling Heating Refrigerant flow Refrigerant pipe connection port diameters Heat exchanger Model Gas Liquid FH(Y)B35FK, FHYB4FK J12.70 J6.35 FHB45FK, FHB60FK J15.0 J6.35 FHYB60FK, FHYB71FK J15.0 J.52 FHYB100FK, FHYB125FK J1.10 J.52 Liquid pipe connection port Filter Gas pipe connection port 4 O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW20435-1G 12 Split - Sky ir Indoor Units

5 Wiring diagrams FHB35-60FK7 Outdoor Indoor Note 3 Notes 1. When using the central remote control, see manual for connection to the unit. 2. The infrared remote controller model varies according to the combination system. refer to technical materials and catalogues, etc. before connecting. 3. Ground the shield of the remote control cord to the indoor unit. Wired remote control Terminals for operation indicator g Field wiring D Terminal a : Connector c : Wire clamp b : Protective earth (screw) Colours BLK: Black / WHT: White / RED: Red / BLU: Blue / GRY: Grey / ORG: Orange Details of wired remote control (optional accessory) Fan operation compressor operation dapter for wiring Switch box 33H Float switch 1P Printed circuit board 2P Printed circuit board (transformer 220-240V/16V) C1R Capacitor (fan) F1T Thermal fuse (152 C) (M1F embedded) F1U Fuse (250V, 5) H1P Light emitting diode (service monitor green) M1F Motor M1P Motor R1T R2T RyC RyF1-4 RyP SS1 X1M X2M RC Thermistor (air) Thermistor (coil) Magnetic relay (outdoor unit compressor) Magnetic relay (fan) Magnetic relay (drain pump) Selector switch (emergency) Terminal strip Terminal strip Signal receiver circuit Wired remote control BS1 On/Off button BS2 Timer mode start/stop button BS3,BS8 Programming time button BS4,BS Temperature setting button BS6 Operation mode selector button BS7 Timer on/off button BS11 Fan speed control button BS12 Inspection/test button BS14 H1P LCD SS1 Filter sign reset button Light emitting diode (service monitor red) Liquid crystal display (LCD) Selector switch (main/sub) dapter for wiring RyC,RyF Magnetic relay Connector for optional parts X30 Connector (interface adapter for sky air series) X33 Connector (adapter for wiring) X35 Connector (group control adapter) 2TW22046-1C 5 FHYB35-71FK7 Outdoor Indoor Note 3 Notes 1. When using the central remote control, see manual for connection to the unit. 2. The infrared remote controller model varies according to the combination system. refer to technical materials and catalogues, etc. before connecting. 3. Ground the shield of the remote control cord to the indoor unit. Wired remote control Terminals for operation indicator g Field wiring D Terminal a : Connector c : Wire clamp b : Protective earth (screw) Colours BLK: Black / WHT: White / RED: Red / BLU: Blue / GRY: Grey / ORG: Orange Details of wired remote control (optional accessory) Fan operation compressor operation dapter for wiring Switch box 33H Float switch 1P Printed circuit board 2P Printed circuit board (transformer 220-240V/16V) C1R Capacitor (fan) F1T Thermal fuse (152 C) (M1F embedded) H1P, H2P Light emitting diode (service monitor green) M1F Motor M1P Motor R1T R2T RyF1-4 RyP SS1 X1M X2M RC TC Thermistor (air) Thermistor (coil) Magnetic relay (fan) Magnetic relay (drain pump) Selector switch (emergency) Terminal strip Terminal strip Signal receiver circuit Signal transmission circuit Wired remote control BS1 On/Off button BS2 Timer mode start/stop button BS3,BS8 Programming time button BS4,BS Temperature setting button BS6 Operation mode selector button BS7 Timer on/off button BS11 Fan speed control button BS12 Inspection/test button BS14 H1P LCD SS1 Filter sign reset button Light emitting diode (service monitor red) Liquid crystal display (LCD) Selector switch (main/sub) dapter for wiring RyC,RyF Magnetic relay Connector for optional parts X30 Connector (interface adapter for sky air series) X33 Connector (adapter for wiring) X35 Connector (group control adapter) 2TW22076-1B Split - Sky ir Indoor Units 13

5 Wiring diagrams FHYB100-125FK7 Outdoor Indoor Note 3 Notes 1. When using the central remote control, see manual for connection to the unit. 2. The infrared remote controller model varies according to the combination system. refer to technical materials and catalogues, etc. before connecting. 3. Ground the shield of the remote control cord to the indoor unit. Wired remote control Terminals for operation indicator g Field wiring D Terminal a : Connector c : Wire clamp b : Protective earth (screw) Colours BLK: Black / WHT: White / RED: Red / BLU: Blue / GRY: Grey / ORG: Orange Details of wired remote control (optional accessory) Fan operation compressor operation dapter for wiring Switch box 5 33H Float switch 1P Printed circuit board 2P Printed circuit board (transformer 220-240V/16V) C1R Capacitor (fan) F1T Thermal fuse (152 C) (M1F embedded) H1P, H2P Light emitting diode (service monitor green) M1F Motor M1P Motor R1T R2T RyF1-4 RyP SS1 X1M X2M RC TC Thermistor (air) Thermistor (coil) Magnetic relay (fan) Magnetic relay (drain pump) Selector switch (emergency) Terminal strip Terminal strip Signal receiver circuit Signal transmission circuit Wired remote control BS1 On/Off button BS2 Timer mode start/stop button BS3,BS8 Programming time button BS4,BS Temperature setting button BS6 Operation mode selector button BS7 Timer on/off button BS11 Fan speed control button BS12 Inspection/test button BS14 H1P LCD SS1 Filter sign reset button Light emitting diode (service monitor red) Liquid crystal display (LCD) Selector switch (main/sub) dapter for wiring RyC,RyF Magnetic relay Connector for optional parts X30 Connector (interface adapter for sky air series) X33 Connector (adapter for wiring) X35 Connector (group control adapter) 2TW2206-1B 14 Split - Sky ir Indoor Units

6 Sound level 6-1 Sound level data Cooling only Sound pressure level 230V Model 50Hz Measuring location Sound power level (H) H L FHB35FK7V15 33 2 52 FHB45FK7V15 33 2 Suction Unit discharge 53 FHB60FK7V15 34 30 60 FHYB71FK7V1 34 30 Microphone 60 FHYB100FK7V1 36 31 62 FHYB125FK7V1 38 32 63 Heat pump Sound pressure level 230V Model 50Hz Measuring location Sound power level (H) H (cooling/heating) L (cooling/heating) FHYB35FK7V1 33 / 33 2 / 2 52 / 52 Suction Unit discharge FHYB45FK7V1 33 / 33 2 / 2 53 / 53 FHYB60FK7V1 34 / 34 30 / 30 60 / 60 FHYB71FK7V1 34 / 34 30 / 30 Microphone 60 / 60 FHYB100FK7V1 36 / 36 31 / 31 62 / 62 FHYB125FK7V1 38 / 38 32 / 32 63 / 63 6 6-1 Split - Sky ir Indoor Units 15

6 Sound level 6-2 Sound pressure spectrum FH(Y)B35-45FK7 FH(Y)B60-71FK7 Sound pressure level (db) Sound pressure level (db) 3TW22047-1 Octave band center frequency (Hz) 3TW22067-1 Octave band center frequency (Hz) 6 6-2 Sound pressure level (db) FHYB100FK7 Sound pressure level (db) FHYB125FK7 3TW22107-1 Octave band center frequency (Hz) 3TW22127-1 Octave band center frequency (Hz) NOTES 1 Data is valid at free field condition 2 Operation sound levels are valid at nominal operation condition 230V 3 db = -weighted sound pressure level (-scale according to IEC) 4 Reference acoustic pressure 0dB = 20µPa Legend High speed Low speed 16 Split - Sky ir Indoor Units

7 Fan characteristics Cooling only FHB35FK7 FHB45FK7 High (high ESP) High (high ESP) External static pressure low High (standard ESP) High (low ESP) Decoration panel External static pressure High (standard ESP) High (low ESP) low B B Internal static pressure ir flow (m 3 /min) Suction panel Long-life filter Internal static pressure ir flow (m 3 /min) Suction panel Long-life filter 7 FHB60FK7 FHYB71FK7 High (high ESP) External static pressure low High (high ESP) High (standard ESP) High (low ESP) B External static pressure low High (low ESP) High (standard ESP) B Internal static pressure Suction panel Long-life filter Internal static pressure Suction panel Long-life filter ir flow (m 3 /min) ir flow (m 3 /min) NOTES 1. The remote control can be used to switch between high and low 2. The air flow is set to standard before leaving the factory. It is possible to switch between standard EPS an high EPS by programming on the remote control. 3. The internal static pressure indicates the characteristics of the fan when a suction panel (optional accessory) and a canvas for the suction panel (optional accessory) are incorporated into the main unit (with a long-life filter). = Upper limit of external static pressure (high ESP) B = Lower limit of external static pressure (high ESP) Split - Sky ir Indoor Units 17

7 Fan characteristics FHYB100FK7 FHYB125FK7 High (high ESP) High (high ESP) High (standard ESP) External static pressure low B External static pressure low B High (standard ESP) Suction panel Long-life filter Suction panel Long-life filter Internal static pressure Internal static pressure 7 ir flow (m 3 /min) ir flow (m 3 /min) = Upper limit of external static pressure (high ESP) B = Lower limit of external static pressure (high ESP) 18 Split - Sky ir Indoor Units

7 Fan characteristics Heat pump FHYB35FK7 FHYB45FK7 (Pa) High (high ESP) High (high ESP) External static pressure low High (standard ESP) High (low ESP) External static pressure High (standard ESP) High (low ESP) low B B Internal static pressure ir flow (m 3 /min) Suction panel Long-life filter Internal static pressure ir flow (m 3 /min) Suction panel Long-life filter 7 FHYB60FK7 FHYB71FK7 (Pa) High (standard ESP) High (high ESP) External static pressure low B High (standard ESP) High (low ESP) External static pressure low High (high ESP) High (low ESP) B Internal static pressure Suction panel Long-life filter Internal static pressure Suction panel Long-life filter ir flow (m 3 /min) ir flow (m 3 /min) NOTES 1. The remote control can be used to switch between high and low 2. The air flow is set to standard before leaving the factory It is possible to switch between standard EPS an high EPS by programming on the remote control 3. The internal static pressure indicates the characteristics of the fan when a suction panel (optional accessory) and a canvas for the suction panel (optional accessory) are incorporated into the main unit (with a long-life filter). = Upper limit of external static pressure (high ESP) B = Lower limit of external static pressure (high ESP) Split - Sky ir Indoor Units 1

7 Fan characteristics FHYB100FK7 FHYB125FK7 High (high ESP) High (high ESP) High (standard ESP) External static pressure low B External static pressure low High (standard ESP) B Internal static pressure Suction panel Long-life filter Internal static pressure Suction panel Long-life filter 7 ir flow (m 3 /min) ir flow (m 3 /min) = Upper limit of external static pressure (high ESP) B = Lower limit of external static pressure (high ESP) 20 Split - Sky ir Indoor Units

8 ir flow patterns FHYB71FK7V1 m 3 /min when using discharge unit (KDGS0D) ir velocity FHYB71FK7V1 m 3 /min when using discharge unit (KDGS0D) Temperature distribution 8 FHYB125FK7V1 m 3 /min discharge unit (KDGS0D) ir velocity Split - Sky ir Indoor Units 21

8 ir flow patterns FHYB125FK7V1 m 3 /min when using discharge unit (KDGS0D) Temperature distribution 8 22 Split - Sky ir Indoor Units

ccessories -1 Standard accessories Check if the following accessories are included with your unit. lso used as packing material Metal clamp 1 pc. Paper pattern for installation 1 pc. Drain hose 1 pc. Insulation for fitting 1 of each For gas pipe For liquid pipe Washer for hanging bracket 8 pcs. FH(Y)B35-45: 8 pcs. FHYBP35-45: 8 pcs. FH(Y)B60: 12 pcs. FHYB71: 12 pcs. FHYBP60-71: 12 pcs. FHYB(P)100-125: 16 pcs. Other: installation manual, operation manual Screws for duct flanges Screws for fixing panels are attached to the air inlet panel. Screws for fixing the paper pattern for installation 6 pcs. -1 Split - Sky ir Indoor Units 23

ccessories -2 Optional accessories Options Nr Item FH(Y)B35,45 FH(Y)B60,71 FHYB100,125 1 Panel related Decoration panel BYBS45DJW18 BYBS71DJW18 BYBS125DJW18 Service access panel KTBJ25K56W KTBJ25K80W KTBJ25K160W High-efficiency filter 65% (colorimetric method) *1 KFJ252L56 KFJ252L80 KFJ252L160 2 Filter related High-efficiency filter 0% (colorimetric method) *1 KFJ253L56 KFJ253L80 KFJ253L160 Filter chamber for bottom suction KJ25L56D KJ25L80D KJ25L160D 3 ir inlet and air discharge outlet related Filter chamber for rear suction KJ25L56B KJ25L80B KJ25L160B ir suction canvas KSJ25K56 KSJ25K80 KSJ25K160 Blind board/screening door KBBJ25K56 KBBJ25K80 KBBJ25K160 ir discharge adapter for round duct KDJ25K56 KDJ25K71 KDJ25K140 Operation control -2 Nr Item Type FH(Y)B35,45 FH(Y)B60,71 FHYB100,125 1 Remote control Wired type BRC1C517 2 Set back time clock BRC1551 3 Central remote control DCS30251 4 unified ON/OFF control DCS30151 5 Schedule timer DST30151 6 dapter for wiring (interlock for fresh air intake fan) KRP1B54 7 Wiring adaptor for electrical appendices KRP451 8 Interface adapter for Sky ir series DT10252 3TW2204-6B *1 If installing a high efficiency filter on the unit, an assembly chamber for either bottom or rear suction is required. 24 Split - Sky ir Indoor Units

10 Control systems 10-1 Wired remote control Fig. 1 BRC1C517 BRC1C517 10 10-1 Fig. 2 5 x 10 (Round end slit) 6.5 x (Round end slit) Cover closed 5 x 7 (Round end slit) HoleJ5 Cover open 3TW23651-1 Split - Sky ir Indoor Units 25

10 Control systems 10-1 Wired remote control Name and function of each switch and display on the remote control 1 ON/OFF BUTTON Press the button and the system will start. Press the button again and the system will stop. 13 DISPLY (DEFROST) 14 TIMER MODE STRT/STOP BUTTON 10 10-1 2 3 4 5 6 OPERTION LMP (RED) The lamp lights up during operation. DISPLY h (UNDER CENTRLISED CONTROL) When this display shows, the system is UNDER CENTRLISED CONTROL. (This is not a standard specification). DISPLY (CHNGEOVER UNDER CONTROL) This display shows when the outdoor unit is individual operation system. DISPLY,,,, (VENTILTION / IR CLENING) This display shows that the total heat exchange unit and the air cleaning unit are in operation. These are optional accessories. DISPLY I, u w (OPERTION MODE) This display shows the current OPERTION MODE. For cooling only type,, (uto) and w (Heating) are not installed. 15 TIMER ON/OFF BUTTON INSPECTION/TEST OPERTION BUTTON 16 This button is used only by qualified service persons for maintenance purposes. PROGRMMING TIME BUTTON 17 Use this button for programming STRT and/or STOP time. TEMPERTURE SETTING BUTTON 18 Use this button for SETTING TEMPERTURE. 1 FILTER SIGN RESET BUTTON FN SPEED CONTROL BUTTON 20 Press this button to select the fan speed, HIGH or LOW, of your choice. OPERTION MODE SELECTOR BUTTON 21 Press this button to select OPERTION MODE. 7 DISPLY b (INSPECTION/TEST OPERTION) When the INSPECTION/TEST OPERTION BUTTON is pressed, the display shows the system mode is in. 22 IR FLOW DIRECTION DJUST BUTTON 23 NOT PPLICBLE 8 DISPLY I (PROGRMMED TIME) This display shows PROGRMMED TIME of the system start or stop. DISPLY O (SET TEMPERTURE) This display shows the set temperature. 10 DISPLY BC (FN SPEED) The display shows the set fan speed. 11 DISPLY a (IR FLOW FLP) 12 DISPLY (TIME TO CLEN IR FILTER) NOTE + For the sake of explanation, all indications are shown on the display contrary to actual running situations. 26 Split - Sky ir Indoor Units

11 Centre of gravity Model B FH(Y)B35,45 700 300 FH(Y)B60,71 1,000 460 FHYB71 1,000 460 FHYB100,125 1,400 640 4TW2016-2D 11 12 Safety device settings FHYB-FK FHB-FK Model Safety devices 35 45 60 71 100 125 3TW2100-2B Fuse Fan motor thermal fuse ( C) 152±2 152±2 152±2 152±2 152±2 152±2 Fan motor thermal protector ( C) Fuse Fan motor thermal fuse ( C) 152±2 152±2 152±2 152±2 152±2 152±2 Fan motor thermal protector ( C) Split - Sky ir Indoor Units 27

13 Installation 45 (or less) 13 Installation without duct Installation with duct Number Description 1 False ceiling 2 Ceiling opening 3 Service access panel (optional) 4 ir filter 5 ir inlet duct 6 Duct service opening NOTES 1 When installing the unit with rear suction, a service opening is necessary for the maintenance of the air filters. 2 When installing the unit with a suction duct, a service opening must be provided in the duct. 3 n optional service access panel is available: Model FH(Y)B35,45 FH(Y)B60,71 FH(Y)B100,125 Service access panel KTBJ25K56W KTBJ25K80W KTBJ25K160W 3TW22044-3 28 Split - Sky ir Indoor Units