Typical Areas of Poor RF Coverage

Similar documents
Can You Hear Me Now?

Can You Hear Me Now?

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

Questions/Comments for Richard Roux from Webinar on 7/11/13

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Unified Fire Authority - Fire Prevention Bureau

NFPA 72 Code Changes vs 2013

Changes in NFPA

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

1301: Fire service features.

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF INSPECTION AND TESTING

Fire Alarm Inspection, Testing, Maintenance. Assuring the System s Operational Reliability

NFPA Changes

El Reno Fire Department Fire Alarm Plan Review Worksheet

NFPA Changes

Full Service Central Station Fire Alarm Listing Evaluation

ICC CODE TECHNOLOGY COMMITTEE DRAFT REVIEW OF FINDINGS ON THE NIST WORLD TRADE CENTER REPORT

FIRE ALARM SYSTEM INSPECTION

Report on First Revision June 2014 NFPA 5000

Southaven Fire Department Fire Marshal s Office 8710 Northwest Drive Southaven, Mississippi Phone: Fax:

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Fire Alarm, Water Flow Alarm & Signaling Systems

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

CHAPTER 23 FIRE SAFETY MEASURES

Report on First Revision November 2013 NFPA 731

Fire Alarm System Fundamentals

NFPA Changes

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

FIRE & LIFE SAFTEY STANDARD

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

CHAPTER 23 FIRE SAFETY MEASURES

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Are You Prepared? The impending impact of Code on Servicing Security Systems


Florida Building Code 2010

Booster Power Supply Manual

Center for Life Safety Education

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events

MXD3G User Manual Revision 0 July 29, 2013

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Chapter 4: Fire Protection Systems

MULTI-PHASED FIRE ALARM AND MASS NOTIFICATION SYSTEM UPGRADES: The Authority Having Jurisdiction (AHJ) and Proper Planning

Functional Performance Test

MODEL B2 INSTALLATION MANUAL

Agency for Health Care Administration

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

SECTION ISOLATED POWER SYSTEMS

Applying Performance-based Fire Alarm System Design Part 4

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Agency for Health Care Administration

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

SECTION FIRE ALARM SYSTEMS

The 2013 National Fire Alarm and Signaling Code

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Fire Alarm Wiring. Circuit types, styles and limitations

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

The Technical Committee on Commissioning and Integrated Testing

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

Fire Protection Coffee Break Training May 2016

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Brighton Area Fire Authority

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

Getting Started with

JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM

SECTION : FIRE ALARM & DETECTION SYSTEMS

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Touchpad Exit Controller Administration Guide

Winnipeg Fire Department Fire Prevention Branch

SYSTEM ENHANCEMENT MODULE

Architectural and Engineering Specification for a. Flash / Flare

MNEC NFPA 72 WHITE PAPER

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

January 1, 2014 Mandatory Effective Date

SP40S-D. Kingfisher Company, inc. Features: Description:

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

The New EMC Directive 2004/108/EC

Panel Remote Annunciators Installation Instructions

CERTIFICATION BULLETIN

Transcription:

1

Typical Areas of Poor RF Coverage Buildings, especially basement levels. Subways, mines. Parking Garages. Naturally Shadowed da Areas : (Canyons, behind hills, river bottoms, etc.) In Public Safety A dead Spot can be a DEAD Spot!

Radio Signal Propagation Radio signals travel from point to point in a fashion similar to light. Radio signals can penetrate t some distance through many types of non- metallic obstacles like glass, wood, bricks, trees, fog, etc. As radio signals pass through ANY obstacle, even air, they loose strength.

LEED Building Construction Leadership in Energy and Environmental Design U.S. Green Building Council (USGBC) Glass: PPG Solarban >45 db attenuation ti EMI/RF (walls): TruProtect 40 to 60dB db attenuation More attenuation of RF signals in green buildings. Bad or Good? 5

THE COVERAGE PROBLEM GOOD COVERAGE POOR COVERAGE

THE COVERAGE SOLUTION

DONOR SITE

Jurisdictions with Local Signal Booster Codes - City of Burbank - City of Folsom - City of Roseville CA - City of Ontario - City of Scottsdale AZ - City of Tempe AZ - City of Ft. Lauderdale FL - Grapevine TX - Hampshire (Illinois) FPD - City of Sparks NV - City of Broomfield CO - City of Boston MA - City of West Hartford CT - City of Irvine CA - City/County of Sacramento - City of Tempe AZ - City of Riverside CA - Sarpy County NE - City of Sparks NV - City of Glendale CA - Mercer Island WA - City of San Jose CA - Muskego WI - Richmond VA and more.

National Code Development Why FIRE codes? The fire code process was driven by firefighters. The fire code process is a nationally recognized code source. These codes are PUBLIC SAFETY codes which include Fire, Police and EMS

NFPA72 2010 Emergency Communications Systems (ECS) Chapter 24 and Annex A

NFPA 72 2010 Code Copyright Notice This material is reproduced with permission from NFPA72, National Fire Alarm and Signaling Code, copyright 2010, National Fire Protection Association NFPA 72 is a registered trademark of the National Fire Protection Association. This is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. The information used in this presentation may not be copied or distributed without written approval. Complete codes may be purchased from NFPA.

NFPA72-2010: 24.5.2.1.1 Non-Interference. No amplification system capable of operating on frequencies or causing interference on frequencies assigned to the jurisdiction by the FCC shall be installed without prior coordination and approval of the authority having jurisdiction. The building manager/owner shall suspend and correct other equipment installations that degrade the performance of the public safety radio system or public safety radio enhancement system.

NFPA72-2010: 24.5.2.1.2 Approval and Permit. Plans shall be submitted for approval prior to installation. At the conclusion of successful acceptance testing, a renewable permit shall be issued for the public safety radio enhancement system where required by the AHJ.

NFPA72-2010: 24.5.2.2.1 & 24.5.2.2.2 24.5.2.2.1 Critical Areas. Critical areas, such as the emergency command center(s), the fire pump room(s), exit stairs, exit passageways, elevator lobbies, standpipe cabinets, sprinkler sectional valve locations, and other areas deemed critical by the AHJ, shall be provided with 99 percent floor area radio coverage. 24.5.2.2.2 General Building Areas. General building areas shall be provided with 90 percent floor area radio coverage.

NFPA72-2010: 24.5.2.2.3 Amplification Components. Buildings and structures that cannot support the required level of radio coverage shall be equipped with a radiating cable system or a distributed antenna system (DAS) with FCC-certified signal boosters, or both, or with a system that is otherwise approved, in order to achieve the required adequate radio coverage. Note: ALL buildings, old and new!

NFPA72-2010: 25.5.2.3 to 25.5.2.3.2 24.5.2.3 Signal Strength. 24.5.2.3.1 Inbound. A minimum inbound signal strength of 95 dbm, or other signal strength as required by the AHJ, shall be provided throughout the coverage area. 24.5.2.3.2 Outbound. A minimum outbound signal strength of 95 dbm at the donor site, or other signal strength as required by the AHJ, shall be provided from the coverage area.

NFPA72-2010: 24.5.2.3.3 24.5.2.3.3 Isolation. If a donor antenna exists, isolation shall be maintained between the donor antenna and all inside antennas and shall be a minimum of 15 db above the signal booster gain under all operating conditions

NFPA72-2010: 24.5.2.4 & 24.5.2.4.1 24.5.2.4 System Radio Frequencies. The public safety radio enhancement system shall be capable of transmitting all public safety radio frequencies assigned to the jurisdiction and be capable of using any modulation technology. 24.5.2.4.1 List of Assigned Frequencies. The AHJ shall maintain a list of all inbound/outbound frequency pairs for distribution to system designers

NFPA72-2010: 24.5.2.4.2 Frequency Changes. Systems shall be capable of upgrade, to allow for instances where the jurisdiction changes or adds system frequencies, in order to maintain radio system coverage as originally designed.

NFPA72-2010: 24.5.2.5.1 Component Approval. Components utilized in the installation of the public safety radio enhancement system, such as repeaters, transmitters, receivers, signal boosters, cabling, and fiber-distributed antenna systems, shall be approved and shall be compatible with the public safety radio system.

NFPA72-2010: 24.5.2.5.2 & 24.5.3.5.3 Component Enclosures. All repeater, transmitter, receiver, and signal booster components shall be contained in a NEMA 4- or 4X- type enclosure(s). 245253ExternalFilters 24.5.2.5.3 Filters. Permanent external filters and attachments shall not be permitted

NFPA72-2010: 24.5.2.5.4 24.5.2.5.4 Signal Booster Components. If used, signal boosters shall meet the following requirements, as well as any other requirements determined by the authority having jurisdiction: (1) Signal boosters shall have FCC certification prior to installation. ti (2) All signal boosters shall be compatible with both analog and digital communications simultaneously at the time of installation.

NFPA72-2010: 24.5.2.5.4, continued The AHJ shall provide the maximum acceptable propagation delay standard. Most used value: 25 microseconds or less.

NFPA72-2010: 24.5.2.6.1 Fire Alarm System. (partial) (2) System and signal booster supervisory signals shall include the following: (a) Antenna malfunction (b) Signal booster failure (3) Power supply supervisory signals shall include the following for each signal booster: (a) Loss of normal ac power (b) Failure of battery charger (c) Low-battery capacity, alarming at 70 percent of battery capacity

NFPA72-2010: 24.5.2.6.2 Dedicated (alarm) Panel. A dedicated monitoring panel shall be provided within the emergency command center to annunciate the status of all signal booster locations. The monitoring panel shall provide visual and labeled indication of the following for each signal booster: (1) Normal ac power (2) Signal booster trouble (3) Loss of normal ac power (4) Failure of battery charger (5) Low-battery capacity

NFPA72-2010: 24.5.2.7 Technical Criteria. The authority having jurisdiction shall maintain a document of technical information specific to its requirements. This document shall contain, as a minimum, the following: (1) Frequencies required (2) Location and effective radiated power (ERP) of radio sites used by the public safety radio enhancement system (3) Maximum propagation delay (in μs) (4) List of specifically approved system components (5) Other supporting technical information necessary to direct system design

NFPA72-2010: Referenced Requirements 10.4 Personnel Qualifications. 10.4.1 System Designer. 10.4.1.1 Fire alarm system and emergency communications system plans and specifications shall be developed in accordance with this Code by persons who are experienced in the proper design, application, installation, and testing of the systems.

NFPA72-2010: Referenced Requirements 10.4.1.2 State or local licensure regulations shall be followed to determine qualified personnel. Depending on state or local licensure regulations, qualified personnel shall include, but not be limited to, one or more of the following: (1) Personnel who are registered, licensed, or certified by a state or local authority (2) Personnel who are certified by a nationally recognized certification organization acceptable to the AHJ (3) Personnel who are factory trained and certified for fire alarm system design and emergency communications system design of the specific type and dbrand of system and who are acceptable to the AHJ

NFPA72-2010: Referenced Requirements 10.4.2 System Installer. 10.4.2.1 Fire alarm systems and emergency communications systems installation personnel shall be qualified or shall be supervised by persons who are qualified in the installation, inspection, and testing of the systems. 10.4.2.2 State or local licensure regulations shall be followed to determine qualified personnel. Depending on state or local licensure regulations, qualified personnel shall include, but not be limited to, one or more of the following:

NFPA72-2010: Referenced Requirements (1) Personnel who are registered, licensed, or certified by a state t or local l authority (2) Personnel who are certified by a nationally recognized certification organization acceptable to the AHJ (3) Personnel who are factory trained and certified for fire alarm system installation and emergency communications system installation of the specific type and brand of system and who are acceptable to the AHJ

NFPA72-2010: Referenced Requirements 10.4.3 Inspection, Testing, and Maintenance Personnel 10.4.3.1 Service personnel shall be qualified and experienced in the inspection, testing, and maintenance of systems addressed within the scope of this Code. Qualified personnel shall include, but not be limited to, one or more of the following: (1) Personnel who are factory trained and certified for the specific type and brand of system being serviced (2) Personnel who are certified by a nationally recognized certification organization acceptable to the AHJ

NFPA72-2010: Referenced Requirements (3) Personnel who are registered, licensed, or certified by a state or local authority to perform service on systems addressed within the scope of this Code (4) Personnel who are employed and qualified by an organization listed by a nationally recognized testing laboratory for the servicing of systems within the scope of this Code

NFPA72-2010: Referenced Requirements 10.5.6 Secondary Power Supply. 10.5.6.1 Secondary Power Supply for Protected Premises, Fire Alarm Systems and Emergency Communications Systems.

NFPA72-2010: Referenced Requirements 10.5.6.3.1 The secondary power supply shall have sufficient capacity to operate the system under quiescent load (system operating in a non-alarm condition) for a minimum of 24 hours and, at the end of that period, shall be capable of operating all alarm notification appliances used for evacuation or to direct aid to the location of an emergency for 5 minutes, unless otherwise permitted or required by the following:.

NFPA72-2010: Annex A Explanatory Material Annex A is not a part of the requirements of this NFPA document but is included for informational purposes only. This annex contains explanatory material, numbered to correspond with the applicable text paragraphs

NFPA72-2010: A.14.4.12.1.3 Testing procedures typically are done on a grid system. A grid is overlaid onto a floor area to provide 20 grid cells. Grid cells are provided with definite minimum and maximum dimensions. For most buildings, using a minimum grid dimensionof20ft(61m)andamaximum of ft (6.1 m) a maximum grid dimension of 80 ft (24.4 m) will suffice to encompass the entire floor area.

20 GRID SQUARES

NFPA72-2010: Signal strength measurements should be taken at the center of each grid and should be performed using standardized parameters as specified in A.14.4.12.1.4. Signal strength typically is recorded on the delivered audio quality (DAQ) scale.

NFPA72-2010: Not more than two nonadjacent grid cells should be allowed to fail the test. In the event that three of the areas fail the test, or if two adjacent areas fail the test, in order to be more statistically accurate, the testing grid resolution should be doubled. This would require decreasing the size to one-half the dimension used in the failed test to a minimum m of 10 ft (3.0 m) and a maximum of 40 ft (12.2 m). Further, to cover the same floor area, the number of grids is quadrupled to 80. Not more than eight nonadjacent or five adjacent grid cells should then be allowed to fail the test.

What To Check: Coverage MUST talk inside this zone. And without relocating, MUST measure a -95 dbm or greater signal level. l A record of the exact test location and measurements should be retained. ONE OF 20+ TEST AREAS A Spectrum analyzer Is recommended d for these tests.

NFPA72-2010: A.14.4.12.1.6 Typically, annual tests require several items to be checked. Annual tests should include all procedures encompassed in 14.4.12.1.1 through 14.4.12.1.4. Signal boosters should be tested to ensure that t the gain is the same as it was upon initial iti installation and acceptance. Backup batteries and power supplies should be tested under load for a period of 1 hour to verify that they will properly operate during an actual power outage. Other active components are typically checked to determine that they are operating within the manufacturer s specifications for the intended purpose.

Reconciling Code Differences There can be differences between various codes, but none that can t be resolved at the local level. It may be simply choosing the code that had the best fit. I recommend you use the strictest codes when they address the same item, for example, if you use -95 dbm signal levels you automatically comply with both national codes.

Reconciling Code Differences Remember; The local authority can modify, add and delete the national codes; that s what makes a local code local. l

Additional Resources - National Fire Protection Agency (NFPA) www.nfpa.org - FCC : www.fcc.gov - International Code Committee (ICC) www.iccsafe.org - Comtronics: www.radioshop.com -National Public Safety Telecommunications Council www.npstc.org - Jack Daniel Company web site: www.rfsolutions.com