Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Similar documents
AIR TERMINALS & DUCT HEATERS.

SECTION AIR DUCT ACCESSORIES

Chilled Water DOAS Fan Powered Terminal Units

BYPASS AIR TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

SECTION DUCTWORK

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser

photo by PFC Price Fan Column

CONDOR. Supply air ceiling QUICK FACTS

Direct Gas-Fired Make-Up Air

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Vertical Air Handler Unit

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Linear Floor Heaters

DACC Health Sciences Building Air Handler Assessment/Study

Zoning System Design Manual

Air Conditioning Clinic

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

EHH SERIES DRAW THROUGH FAN COILS CFM

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

Application Data Part Numbers: 33ZCVVTZC-01, 33ZCBC-01, 33ZCVAVTRM, 33ZCFANTRM

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

City of Duluth Festival Center 04/25

VCD,VRD,VSD 4/5 GREEN TEMPERATURE OFFSET FOR WINTER HEATING AND COOLING CHANGEOVER MECHANICAL THERMAL MECHANISM

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Modular Supply Make-Up Air Unit

VIFB Coil Technical Guide

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Indirect Gas-Fired Make-Up Air

SECTION AIR OUTLETS AND INLETS

HOTEL CHILLED BEAM IQ STAR SILENCIA

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

Heat Recovery Unit HERU. web-version

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

MB Therma-Fuser Standalone Motorized Disc VAV Diffuser

VIFB Coil Technical Guide

AcoustiFlo Fans: Retrofit Solutions and Beyond

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

15900 HVAC INSTRUMENTATION AND CONTROLS

SECTION DUCTWORK

Performance Aire offers three VAV comfort solution packages.

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

DIVISION 15 MECHANICAL

Product Data. Features/Benefits. WEATHERMASTER 36R,T Bypass Control Induction Air Terminals to cfm (1880 to 7100 Btuh)

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Actionair Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications

Computing Services Center

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS DIRECT DIGITAL CONTROLS (DDCS) AND PNEUMATICS

System architecture. Air treatment Index

ATC Heating Devices. P. 1 ATC Heating Devices

Application Data. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan-Powered Terminal Units for Variable Air Volume (VAV) Systems

FCC Fan-Coil Units High-Performance, Vertical

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

DEMAND CONTROLLED VENTILATION WITHOUT WIRES

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Twin City Fan & Blower

INSTALLATION DO S AND DON TS

CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Product Specifications. Vertical Floor Consoles By First Co.

M SERIES BLOWER MODULE 60 Hz

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

Ceiling diffusers. Type DLQL

COMcheck Software Version Mechanical Compliance Certificate

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

PCAH SERIES AIR HANDLER

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

DESIGNING MODULAR VAV SYSTEMS

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Therma-Fuser Square Thermally Powered VAV Diffuser

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

INSTALLATION & OPERATIONS MANUAL

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Grilles & Diffusers - Metal

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Life Safety Dampers Selection and Application Manual

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

VERTICAL FAN COIL UNITS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Transcription:

BYPASS TERMINAL UNITS

DVAC, One Of The Premium Workshops Specialized in Duct Fabrication has Executed Several Projects (Residential, Governmental, Commercial, Industrial & Institutional). 2

BYPASS TERMINAL UNITS 2300 Model The 2300 Model - Bypass is a Single Duc t Air Terminal Unit, Designed for Use with Popular Constant Volume Low and Medium Pressure Packaged Air Handling Systems or Roof Top Air Conditioning Units. Temperature Control is Achieved by Only Supplying Enough Conditioned Air to the Space to Meet Room Thermostat Demand. Excess Air is Diverted (Bypass) Directly to the Return Air Ceiling Plenum for Free or Ducted Return. Airflow to Each Occupied Zone Varies on Thermostat Demand, from Full Flow to Shut-of f, or to a Mechanically Set Minimum Air Volume. A Bypass Box Handles a Constant Supply of Primary Air Through its Inlet and Uses a Diverting Damper, to Bypass Part of the Supply Air Into the Plenum Return. The Damper is Directly Controlled by the Room Thermostat in the Occupied Space to Provide the Volume of Air Required to Meet the Thermal Demand. The Pressure Requirement, Through the Supply Air Path to the Conditioned Space, is Set with an Inlet Balancing Damper. Airflow FEATURES: Casing: 22 Gage Galvanized Steel L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation, with Rectangular Inlet and Outlet and Optional Connection. Blade: The Control Damper Blade is 22 Gage Galvanized Steel Which is Designed for Reliable Long Term Operation and 90º Rotation. Axles and Shaft: 10x10mm Square, plated steel. Linkage: Side Linkage Concealed in Frame for the Blade Operation. 3 2 1 Casing 2 Blade 3 Axle Seal (Gasketing) 1 3

I NSULATION: Insulation Clean Linear is Produced from Strong Resilient Glass Fibers Firmly Bounded Together with Thermosetting Resin Which Provides Efficient Sound Insulation. Thermal Performance KCL 8 kg/m 3 Thermal Conductivity W/m.K 0.03 0.031 0.032 0.036 0.038 0.02 Mean Temperature C 0 10 25 50 75 100 Tested in accordance with ASTM C518 Acoustical Performance KCL 8kg/m3 Thickness 25 mm Absorption Coefficient At One Third Octave Band Center Frequencies (Hz) 125 250 500 1000 2000 000 NRS 0.22 0.52 0.73 0.98 1.02 1 0.8 Tested in accordance with ASTM C23 Physical Performance Properties Operation Temperature Limits Water Vapor Absorption Fungi Resistance Bacteria Resistance Air Velocity Rating Air Erosing Rating Performance Maximum 230 C Not Greater than 1% by Volume Does not Breed or Promote Growth 25.m/s Nil at 63.5 m/s Test Method ASTM C 11 ASTM C 110 ASTM C 1071 UL 181 UL 181

ACTUATOR: Pneumatic Actuator A Bypass Terminal Unit DVAC Handles a Constant Supply of Primary Air Through its Inlet. The Unit By-passes Primary Air to The Ceiling Plenum to Meet the Needs of The Conditioned Space. Primary Air diverted Into the Ceiling Plenum- by means of Modulating Control Signal From Electronic Actuator (Belimo Electronic Actuator)- Returns to the Central Air Handler. Electronic Actuator An electric signal from a Proportional Room Controller thermostat is transmitted to the actuator. The Electronic Actuator activates the Proportional Stage of the Bypass VAV Plate Position, by Increasing Primary Airflow or Reducing Primary Airflow, Subject to Temperature Set-point in Room Controller Thermostat. Besides Wiring of the Power Supply, you Must Connect the Appropriate Wires to the Thermostat (See Wiring Diagram Figure). Important: Do not Back-drive Actuator with Setscrew, Damage May Occurs. Rotate Actuators to Minimum Position Using the Manual Declutch. Accurately Set Minimum Flow by Backing-off Setscrew as Required Using Airflow Measurement. Using Locknut, Secures Against Actuator Housing to Lock Setscrew in Place. 5

SELECTION Side View Dimension Model 2300 Bypass Inlet Airflow Outlet Airflow 25 Depth 25 Front View Top View Height W+30mm Width BYPASS TERMINAL UNITS MODEL 2300 Dimensional Data 30 Standard 200mm Item Code Flow Rate Duct Connection (mm) Max. CFM Max. L/S Width (mm) Height (mm) Depth (mm) Inlet Outlet VAV-BTU2035 00 189 00 00 00 350X200 350X200 VAV-BTU205 700 330 500 00 00 50X200 50X200 VAV-BTU2055 1100 519 600 00 00 550X200 550X200 VAV-BTU2550 1600 755 550 500 500 500X250 500X250 VAV-BTU2565 2100 991 700 500 500 650X250 650X250 VAV-BTU2575 2800 1322 800 500 500 750X250 750X250 VAV-BTU2585 3500 1652 900 500 500 850X250 850X250 VAV-BTU25105 5000 2360 1100 500 500 1050X250 1050X250 VAV-BTU35105 7000 3303 1100 600 500 1050X350 1050X350 6

Remarks: DOHA - QATAR - PHONE: +97-500118 - +97-500119 - FAX: +97-500117 7

Small Industries Zone - Pink Area Zone 81 - Street 13 - Bldg. 57 Tel: +97 5 00 118-5 00 119 Fax: +97 5 00 117 P.O. Box: 55619 - Doha, State Of Qatar Email: info@dvac-duct.com Website: www.dvac-duct.com