OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Similar documents
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

Heat Recovery Ventilation

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

INSTALLATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

General safety precautions English

General safety precautions English

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

SYSTEM Inverter Air Conditioners

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Ventilation. Technical Data. Heat Reclaim Ventilation EEDEN HRV design guide

OPERATION MANUAL. Wireless Remote Controller Kit

Installation/Instruction Manual

15,000 BTU Portable Air Conditioner

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

SYSTEM Inverter Air Conditioners

General safety precautions English

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Wireless Remote Controller Kit

USER S MANUAL HSC-14/18/24/24A

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

NEXXOS INVERTER USER MANUAL

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

WIRED REMOTE CONTROLLER

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

General safety precautions English

General safety precautions English

53 KNL / 53 QNL OWNER S MANUAL

Bosch Split-Type Ductless Air Conditioner / Heat Pump

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXAQ15PAV1 FXAQ20PAV1 FXAQ25PAV1 FXAQ32PAV1 FXAQ40PAV1 FXAQ50PAV1 FXAQ63PAV1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

SYSTEM Inverter Air Conditioners

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

AIRREX DEHUMIDIFIER ADH-100 USER S MANUAL

General safety precautions English

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

KSD-35 DR11 KUE-35 DVN11

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

Using the Remote Control Unit

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.

IMPORTANT INSTRUCTIONS READ & SAVE

Installation Instructions

Owner s Manual CS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Owner s Manual Super-Slim Four-Way Cassette

Si Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1

Inverter Split-type Room Air Conditioner

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

IMPORTANT INSTRUCTIONS READ & SAVE

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

HEAT & COOL MODEL (REVERSE CYCLE)

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

JT-SB116JH-G-NA JT-SB116JH-W-NA

WIRED REMOTE CONTROLLER

CDKD25CVM CDKD35CVM Operation Manual

Wireless Remote Controller Kit

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

USER MANUAL. Fan coil units FWC06B7TV1B FWC07B7TV1B FWC08B7TV1B FWC09B7TV1B FWC06B7FV1B FWC07B7FV1B FWC08B7FV1B FWC09B7FV1B. Cover Cover.

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Manual for Ceiling Patio Heater

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Gallery Electric Fireplaces

MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN ROOM AIR CONDITIONER. Operation Manual

WIRED REMOTE CONTROLLER

Owner s Manual. Indoor Unit MMK-AP0074MH-E MMK-AP0094MH-E MMK-AP0124MH-E AIR CONDITIONER (MULTI TYPE) Model name: High-Wall Type.

INSTALLATION MANUAL. Model UAT150CGXY1 UAT180CGXY1 UAT240CGXY1 UAT300CGXY1 UAT150CGXY19 UAT180CGXY19 UAT240CGXY19 UAT300CGXY19.

AE2400 Elite Series Ceramic Tower. Instruction Manual

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Operating Instructions

IMPORTANT INSTRUCTIONS READ & SAVE

Owner s Manual. For wireless remote controller. Indoor Unit

KTIR AIR CONDITIONER SERIES OWNER S MANUAL

Installation and operation manual

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

Electric Hand dryer. Installation and operating manual

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

Owner's Manual TABLE OF CONTENTS

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OPERATION MANUAL. VRV Classic System air conditioner RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OPERATION MANUAL. Split system air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB

OPERATION MANUAL. Split system air conditioners FDYP125B8V1 FDYP200B8V1 FDYP250B8V1 FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B

Transcription:

OPERATION MANUAL (Ceiling mounted duct type) VAM50FC VAM500FC VAM650FC VAM800FC VAM000FC VAM500FC VAM000FC

8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6

7 A A B B 5 6 5 6 7

VAM50F VAM800F VAM500F VAM500F VAM000F VAM000F VAM650F Contents Page Safety cautions... Names of parts... Operation... Maintenance... Trouble and countermeasure... 5 Disposal requirements... 6 Thank you for purchasing this Daikin HRV. The original instructions are written in English. All other languages are translations of the original instructions. HRV Heat Reclaim Ventilation Before using the DAIKIN HRV, be sure to read this operation manual thoroughly. If you have any problems or there is a malfunction, please refer to this operation manual. Please keep this manual for your future reference whenever you do not understand how to use it when something is wrong with the unit during the operation. Safety cautions Read the following cautions carefully and use your equipment properly. Meaning of warning and caution symbols: NOTE WARNING CAUTION Failure to follow these instructions properly may result in personal injury or loss of life. Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. These instructions will ensure proper use of the equipment. Be sure to follow these important safety cautions. Keep these warning sheets handy so that you can refer to them if needed. Also, if this equipment is transferred to a new user, make sure to hand over this user s manual to the new user. WARNING + ELECTRIC SHOCK Before servicing the unit always shut off power, otherwise electric shock may occur. Never inspect or service the unit by yourself. Ask a qualified service person to perform this work. Always use the air filter. If the air filter is not used, heat exchange elements will be clogged, possibly causing poor performance and subsequent failure. Do not change operations suddenly. It can result not only in malfunction but also failure of switches or relays in the body. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Do not use an HRV or an air suction/discharge grille in the following places: - Places such as machinery plants and chemical plants where gas, which contains noxius gas or corrosive components of materials such as acid, alkali, organic solvent and paint, is generated. - Places where combustible gas leakage is likely. Such gas can cause fire. - Places such as bathrooms subjected to moisture. Electric leak or electric shock and other failure can be caused. - Places subjected to high temperature or direct flame. Avoid a place where the temperature near the HRV unit and the air suction/discharge air grille exceeds 50 C. If the unit is used at high temperature, deformed air filter and heat exchange element or burned motor result. Unit ambient temperature conditions should be between -5 C and 50 C (80% relative humidity or less) - Places subjected to much carbon black. Carbon black attaches to air filter and heat exchange element, disabling them. VAM50~000FC P595-05.08

Names of parts Refer to figure (models VAM50~000F) and figure (models VAM500~000F) Ceiling hook Duct connection flange Exhaust fan Air filter (Long life filter) 5 Damper 6 Switch box 7 Maintenance cover 8 Heat exchange elements 9 Name plate 0 Air supply fan Remote controller (Option parts) Damper motor EA (Exhaust air) (Exhaust air to outdoor) OA (Outdoor air) (Fresh air from outdoor) 5 Maintenance space for the air filters, the heat exchange elements and Switch box 6 RA (Return air) (Exhaust air from room) 7 SA (Supply air) (Feed air to room) Operation method The remote controller for air conditioner turns the air conditioner and HRV unit on and off. If only the HRV unit is used without operating the air conditioner, set the unit in the VENTILATION mode. (Refer to the section "Operating the HRV unit using the remote controller of the VRVsystem air conditioner" on page ) Combination Operation method The ON/OFF and timer operation can not be performed using the HRV remote controllers. (The indication of centralized control appears on the display.) Other operations can be performed using the HRV remote controllers. Starting and stopping operations of the indoor unit and the HRV unit can be performed using the indoor remote controllers. (Refer to the section "Operation with the remote control exclusively for Air conditioning operation HRV units (BRC0B6)" on page ) Centralized system Centralized controller HRV unit Operation Explanation for systems This product is operated differently depending on the system configuration. For the operation of the remote controller for indoor unit and of the centralized controller, refer to the instruction manual provided with each unit. Operation for each system Indoor unit Remote controller for HRV unit (BRC0B6) Independent system HRV unit Operation method The remote controller turns the HRV unit on and off (refer to the section "Operation with the remote control exclusively for Air conditioning operation HRV units (BRC0B6)" on page ). Combined operation system with VRV systems and Sky-air series Combination Remote controller for HRV unit (BRC0B6) Remote controller for indoor unit Operation method When the HRV remote controllers is not connected, the Centralized controller controls the operation of the HRV unit. (Refer to the section "Independent operation of the HRV unit using the centralized controller (DCS0C5)" on page ) When the HRV remote controllers is connected, operation can be started and stopped using the centralized controller or the indoor and the HRV remote controllers. During the indication of centralized control appears on the display, the ON/OFF and timer operation may not be possible with the HRV remote controllers. Other operations can be performed using the HRV remote controllers. (Refer to the next sections) Indoor unit HRV unit Remote controller for indoor unit VAM50~000FC P595-05.08

Operation with the remote control exclusively for Air conditioning operation HRV units (BRC0B6) For non-independent systems, starting/stopping operation and timer operation may not be possible. Use the air conditioner remote control or the Centralized controller in such cases. 6 0 HRV TEST BRC0B6: Remote controller for HRV hr hr 5 7 FRESH UP ( ) BRC0B6. Operation lamp This pilot lamp (red) lights up while the unit is in operation.. Operation/Stop button When pushed once, the unit starts operating. When pushed again, the unit stops.. Air flow rate changeover button Air flow rate can be changed over to Low mode or High mode, FRESH UP Low FRESH UP mode, FRESH UP High FRESH UP mode. For FRESH UP operation When this indication does not show: The volume of outdoor air supplied into the room and that of the room air exhausted outdoors is equivalent. For FRESH UP operation If it is set to Fresh up air supply : The volume of outdoor air supplied into the room is larger than that of room air exhausted outdoors. (This operation prevents the odor and moisture from kitchens and toilets from flowing into the rooms.) This is the factory setting. If it is set to Fresh up air exhaust : The volume FRESH UP of room air exhausted outdoors is larger than that of outdoor air supplied into the room. FRESH UP (This operation prevents the hospital odor and floating bacteria from flowing out to the corridors.) To change the setting, refer to chapter Local settings in the installation manual. A 8 9. Ventilation mode changeover button A ( Automatic mode. The temperature sensor of the unit automatically changes the ventilation of the unit in Bypass mode and Heat Exchange mode. Heat Exchange mode. In this mode, the air passes through the heat exchanger element to effect Total Heat Exchanging ventilation. Bypass mode. In this mode, the air does not pass through the heat exchange element but by passes it to effect Bypass ventilation. ( 5. Indication of operation control method: When the operation of HRVs are linked with the air conditioners, this indication may be shown. While the indication is shown, the ON/OFF of HRVs cannot be operated by the HRV remote controller. 6. Indication of operation standby: It indicates the precooling/preheating operation. This unit is at stop and will start operation after the precooling/preheating operation is over. Precooling/preheating operation means the operation of HRVs is delayed during the startup operation of linked air conditioners, for example before the office hours. During this period the cooling or heating load is reduced to bring the room temperature to the set temperature in a short time. 7. Indication of centralized control: When a remote controller for air conditioners or devices for centralized control are connected to the HRVs, this indication may show. When this indication appears on the display, the ON/OFF and timer operation may not be possible with the HRV remote controllers. 8. Indication of air filter cleaning When the indication appears on the display, clean the filter. 9. Filter signal reset button 0. Inspection button This button is to be used only for service. It is not to be used normally. How to operate with timer. Schedule timer button /. This button enables or disables the schedule timer.. Push the time adjust button to set the time.. Push the programming button / Then, the reservation is finished. ( A ( VAM50~000FC P595-05.08

Operating the HRV unit using the remote controller of the VRV-system air conditioner Please read the manual supplied with the remote controller for more detailed instructions (optional controllers: BRCD5 or BRCE5). 5 6 7 Every time the operation mode selector is pressed, the operation mode display changes as shown below. Example When air conditioner and HRV unit are not connected by duct When air conditioner and HRV unit are connected by duct /Cooling Ventilation /Cooling Ventilation 5 /Fan Ventilation /Ventilation /Fan Ventilation 6 0 9 7 When the FILTER indication appears on the display, clean the filter of the HRV unit. (Refer to the section "Maintenance" on page ) For adjusting the installation settings, contact your installer. BRCD5: Remote controller for VRV Operation lamp Operation/stop button Fan speed icon Air filter cleaning time icon 5 Element cleaning time icon 6 Air conditioner fan speed button 7 Air filter cleaning time icon reset button 8 Air conditioner operation mode 9 Inspection button 0 Air flow rate changeover button See "How to operate with timer" on page Ventilation mode button 5 Operation mode display 6 Defrost/hotstart mode icon 7 Indication of centralized control When the VRV-system air conditioner is connected with the HRV unit with a direct duct, the remote controller of the air conditioner cannot be used to select the VENTILATION mode. To use the HRV unit without operating the air conditioner, set the air conditioner in the FAN VENTILATION mode and select the low fan speed. 8 Independent operation of the HRV unit using the centralized controller (DCS0C5) After selecting the zone where only the HRV operation is desired, press the operation mode selector and select VENTILATION. The HRV unit can then be operated independently from the air conditioner. When the FILTER indication appears on the display, clean the filter of the HRV unit. (Refer to the section "Maintenance" on page ) Maintenance (for a qualified service person only) WARNING Be sure to turn off the OPERATION switch and disconnect the power. Only a qualified service person is allowed to perform maintenance. During operation, never check or clean the HRV. It may cause electrical shock and it is very dangerous to touch the rotating part. Maintenance for the air filter Cleaning frequency At least once every two years (for general office use) (clean more frequently if necessary.) Go into the ceiling through the inspection hole, remove binding metal of maintenance cover and take it off. (Refer to figure (A = Models VAM50~000F, B = Models VAM500~000F)) Maintenance cover Binding metal Hanging metal VAM50~000FC P595-05.08

Take out the heat exchange elements from the unit body. (Refer to figure (A = Models VAM50~000F, B = Models VAM500~000F)) Heat exchange element Handle Rail Filter To clean the air filter, lightly pat it with hand or remove dust with a vacuum cleaner. If excessively dirty, wash it in water. (Refer to figure 5) If the air filter is washed, remove water completely and allow to dry for 0 to 0 minutes in the shade. When dried completely, install the air filter back in place. (Refer to figure 6) 5 Install the maintenance cover securely in place. Maximum allowed torque on the screws is,7 Nm. CAUTION Do not wash the air filter in hot water. Do not dry the air filter over a fire. Do not subject the air filter to direct sunlight. Do not use organic solvent such as gasoline and thinner on the air filter. Be sure to install the air filter after servicing. (Missing air filter causes clogged heat exchange element.) Replacement air filters are available. Maintenance for the heat exchange element Cleaning frequency At least once every two years (for general office use) (clean the element more frequently if necessary.) Use a vacuum cleaner to remove dust and foreign objects on the surface of the heat exchange element. (Refer to figure 7) - Use the vacuum cleaner equipped with a brush on the tip of the suction nozzle. - Lightly contact the brush on the surface of the heat exchanging element when cleaning. (Do not crush the heat exchange element while cleaning.) Install the air filter securely in place. Put the heat exchange element on the rail and insert it securely in place. Install the maintenance cover securely in place. CAUTION Never wash the heat exchanger element with water. Trouble and countermeasure If your unit does not operate properly, check the following items Conditions Causes Corrective actions The unit does not operate at all. Check if there is a power failure. After power has been restored, start operation again. Check if the fuse has blown or breaker has worked. Change the fuse or set the breaker. Amount of discharged air is small and the discharging sound is high. Amount of discharged air is large and so is the sound. Check if the indication of operation control method on remote controller (BRC0B6) is shown. Check if the indication of operation stand by on remote controller (BRC0B6) is shown. Check if the air filter and heat exchange element are clogged. Check if the air filter and heat exchange element are installed. This is normal. Operate the unit using the air conditioner remote control or centralized controller. (Refer to "Operation" on page ) It indicates the precooling/preheating operation. This unit is at stop and will start operation after the precooling/preheating operation is over. (Refer to "Operation" on page ) Refer to "Maintenance" on page. Refer to "Maintenance" on page. If the following occurs, consult the dealer where the unit was purchased List of malfunction codes of remote controller of the HRV-system air conditioner Operation lamp Inspection indicator Unit No. Malfunction code Description On Off Blinking 6 Indoor air thermistor malfunction On Off Blinking 65 Outdoor air thermistor malfunction On Off Blinking 6A Damper-related malfunction Blinking Blinking Blinking 6A Damper-related malfunction + thermistor Blinking Blinking Blinking A6 Locked rotor Blinking Blinking Blinking C Fan communication error Blinking Blinking Blinking U5 Transmission error between the unit and remote controller Off Blinking Off U5 Printed circuit board error or setting error of remote controller Off Blinking Off U8 Transmission error between main remote controller and sub remote controller Off Blinking Blinking UA Wrong remote controller installed On Off On UC Repeated central address Blinking Blinking Blinking UE Transmission error between the unit and centralized controller In case of malfunction with the code in white letters on black background, the unit still operates. However, be sure to have it inspected and repaired as soon as possible. 5 VAM50~000FC P595-05.08

Disposal requirements Dismantling of the unit must be done in accordance with relevant local and national legislation. VAM50~000FC P595-05.08 6

Copyright 05 Daikin P595-05.08