QAW70. Room Unit. Building Technologies. for use with heating controllers

Similar documents
QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Room Unit. Building Technologies SYNERGYR

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

RVP310. Heating Controller. Building Technologies HVAC Products

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

RVL479. Heating Controller. for use with a partner unit

RVL481. Heating Controller. including d.h.w. heating

District heating controller

Room Temperature Controllers

Use. For 2-pipe fan coils

PRELIMINARY EDITION

RVL470. Heating Controller. Use. Functions. Series B

District heating controller

RVL480. Heating Controller

Self-learning Room Temperature Controller

Use. Functions. Key function. Other functions

Self-learning Room Temperature Controller

Room Temperature Controller

District Heating Controller

Semi flush-mount room thermostats

Digital Room Thermostat for Heating Applications with 7-Day Time Program

REA22 Room Temperature Controller

Room thermostat with 24-hour time switch and large LCD

RAB21 RAB21.1. For two-pipe fan coils

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

Frost Protection Thermostat

Self-learning Room Temperature Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

G a

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

Room thermostat with Auto Timer, Option External Input

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

Room Temperature Sensors

Room thermostat with Auto Timer, Option External Input

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Room thermostat with Auto Timer, independent DHW

Wall-mounted room thermostat with LCD

Room Temperature Controller

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Room thermostats with LCD RDD100..

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Heating and D.h.w. Controller RVL482 Basic Documentation

Operating Instructions

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room Temperature Controller

Room thermostat with Auto Timer, Option External Input

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

No. Icon Name Function

COMFORT IP: Room Control Unit Radio with Display

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Room Temperature Sensors

Room thermostat with independent DHW control

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

for relative humidity and temperature with calibration certificates

Room thermostat with Auto Timer, Option External Input

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Flush-mounted room thermostat

Flush-mounted room thermostats

Electronic timeswitch

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

Control solutions Biofloor

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Central apartment unit

RVL47. Heating Controller. Installations Instructions. Installation

Frost Units for air temperature monitoring

1592P01. for liquids in piping DN

Duct Temperature Sensors

Wireless room thermostat with LCD

ECL Comfort V a.c. and 24 V a.c.

Room Unit for Boiler Control QAA User manual. Building Technologies. With OpenTherm Interface

Heating Controller. Synco 700

Room Temperature Controller with LCD

Smart Thermostat RDS110

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Semi flush-mount communicating room thermostats

Immersion Temperature Controller

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Heating Controller. Building Technologies HVAC Products. Synco 700

Room thermostats with LCD for wall mounting

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Preliminary Release. Room Temperature

Boiler Sequence Controller

Indoor Air Quality Controller

Room Air Quality Sensors

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Operating Instructions

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Application description

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Transcription:

1 637 Room Unit for use with heating controllers QAW70 Digital, multi-functional room unit for the convenient operation of heating controllers from the living room A setpoint knob and an economy button allow straightforward adjustment of the room temperature setpoint The unit features a 7-day heating program, adjustable temperature setpoints, operating mode selection and an info button Use Depending on the type of heating controller used, the QAW70 is specifically suited for Single-family homes Holiday houses Functions Ergonomic and function-specific assignment of operation to 3 operating levels Info button for fast retrieval of important information Buttons for direct selection of operating mode Occupancy button for influencing the heating system temporarily or continuously Setting knob for straightforward readjustment of the room temperature setpoint Entry of room temperature and dhw temperature setpoints Heating program with 3 heating periods per day; each day can be individually selected Holiday function Resetting the parameters to their default values CE2N1637E 2014-07-30 Building Technologies

PPS interface for the heating controller (with selectable device address) Protection of setting values against tampering (operating lock) Connection facility for an external switch (telephone switch) Connection facility for an external room temperature sensor Selectable display format for the setpoint (absolute / relative) Ordering When ordering, please give type reference QAW70 and the language code letter (-A or -B) for the Operating Instructions in the requested language: -A for English, French, Italian, German (eg QAW70-A for English) -B for Dutch, Swedish, Greek, Polish (eg QAW70-B for Dutch) If an external room temperature sensor is required, it must be ordered as a separate item Equipment combinations Suitable heating controllers The QAW70 is suited for use with all types of heating controllers from SBT HVAC Products featuring a PPS interface External sensor Room temperature sensor: QAW44 Mechanical design The room unit consists of base and operating section The base can be mounted and wired before the operating section is fitted Casing and base are made of plastic The major plastic components bear the material references to facilitate environmentalfriendly disposal Operating elements 1 2 3 AUTO 4 5 6 7 8 9 C 2273Z01 1 Display 2 Display occupancy button 3 Info button 4 Operating mode button automatic mode 5 Operating mode button manual operation 6 Operating mode button standby 7 Cover 8 Temperature setting knob 9 Occupancy button 2/6

Display 10 1 2 3 2312Z01 9 0 4 8 12 16 20 24 C 8 7 6 5 4 1 Digits, clock 2 Heating program 3 Units ( C) 4 Display occupancy button 5 Outside temperature 6 Room temperature 7 Holiday function 8 Operating mode 9 Line number 10 Dhw temperature Technical design Operating levels Info button Operating modes Occupancy button Automatic mode Manual operation Setpoint readjustment Setpoints The QAW70 features ergonomic and function-specific assignment of operation to 3 operating levels Operation by the end-user: Unit cover closed Operation via info button, operating mode buttons, occupancy button and setting knob for setpoint readjustments Programming by the end-user: Unit cover open Programming via the 4 programming buttons on operating lines 1 17 Service level: Unit cover open This level can only be accessed by pressing a certain combination of buttons Parameterization / programming is made possible via 4 programming buttons on operating lines 51 58 Using the info button, the end-user can retrieve the following key data: Weekday and time of day Outside temperature Time of day and room temperature The value selected last is maintained on the display Three buttons are used to select the 3 available operating modes: Automatic mode (change between the nominal room temperature and the reduced temperature according to the time switch settings) Manual operation (nominal room temperature or reduced room temperature continuously) Standby (frost / holiday temperature) The occupancy button is used to switch from the nominal room temperature to the reduced room temperature, and vice versa The action depends on the selected operating mode Changeover is only temporary; after the next switching point of the heating program, the controller will resume operation according to the settings made Changeover is on a continuous basis until the button is pressed again The temperature setting knob can be used to readjust the nominal room temperature setpoint by ±3 K If required, the setting knob s readjustment range can be mechanically limited The following setpoints can be entered on the unit: Nominal setpoint of the room temperature Reduced setpoint of the room temperature Setpoint of the dhw temperature 3/6

Heating program Holiday function Default values PPS interface Operating lock External sensor External switch Display of setpoint The heating program is provided by a 7-day time switch Each day may have a maximum of 3 heating periods whereby each weekday can be individually programmed The heating program of the current weekday appears on the display in graphic form When the holiday period starts, the duration in days can be entered During the holiday period, the room temperature is maintained at the standby level, ensuring protection against frost If active, the holiday function is shown on the display The temperature setpoints, the heating program and the holiday function can be reset to their default values at any time For heating controllers that operate 2 room units via their PPS interface, the device address can be set on the QAW70 On the service level, an operating lock can be activated When activated, it is no longer possible to change operating lines The QAW70 can also be used with an external temperature sensor The authority of that sensor can be set to between 0 and 100 % The use of an external switch allows changeover of the operating mode by some other device (eg a telephone switch) On the QAW70, it is possible to select whether the reduced room temperature or the frost / holiday mode temperature shall be maintained when the switch has closed its contact With analog heating controllers only frost / holiday mode temperature is possible The operating action of the switch can also be selected It is possible to select whether display of the setpoint shall be absolute or relative Notes Engineering All connection terminals carry extra low voltage The local regulations for electrical installations must be complied with Sensor cables should not be run parallel to mains cables The room unit should be installed in the main living room If the control system uses room temperature influence, the room unit should be installed in a room that is representative of the entire house (reference room) If that room is equipped with thermostatic radiator valves, they must be set to their fully open position The mounting location should be such that the room unit can sense the room temperature as accurately as possible This means that it should not be exposed to direct solar radiation or to other heat or refrigeration sources The room unit should be fitted about 15 m above the floor The room unit can be fitted on most commercially available recessed conduit boxes or directly on the wall Commissioning Every unit is supplied with mounting and commissioning instructions 4/6

Disposal The devices are considered electronics devices for disposal in term of European Directive 2012/19/EU and may not be disposed of as domestic waste Dispose of the device via the channels provided for this purpose Comply with all local and currently applicable laws and regulations Technical data Operating voltage Perm ambient temperature Transport and storage Operation Degree of protection (when mounted on a closed wall) DC 10 15 V 25 +65 C 0 35 C Protection class III according to EN 60730-1 Protection degree of housing IP 30 according to EN 60529 Overvoltage protection: max permissible voltage Terminals D1/D2 24 V Terminals D3/D4 (sensor / switch) 13 +5 V Room temperature sensor Time constant 10 min Coupling to the wall 50 % Measurement range 0 32 C Perm cable lengths to the heating controller (PPS interface) Copper cable 025 mm 2 max 25 m Copper cable from 05 mm 2 max 50 m Perm cable lengths to the external switch or sensor Copper cable 06 mm dia max 20 m Copper cable from 10 mm 2 max 50 m Directives and Standards Produkt Standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residental,commerce,lightindustrial and industrial environments EU Conformity (CE) CE1T1637xx *) Environmental compatibility The product environmental declaration CE1E1637en *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) Reserve of clock min 12 h Weight (net) 022 kg Color of front RAL 9010 (pure-white) *) The documents can be downloaded from http://siemenscom/bt/download 5/6

40,5 143 1637M01 Connection diagrams With an external QAW44 sensor With an external switch (remote telephone switch) QAW44 M MD A6 M MD A6 N1 S1 1637Z04 6 5 4 3 2 1 D4 D3 D2 D1 QAW70 QAW70 D1 D4 Terminals of QAW70 N1 Controller S1 External switch Dimensions 30 30 30 28 4,2 1637M02 30 28 97 34 41 28 28 12 80 5 Dimensions in mm 6/6 ã2014 Siemens Switzerland Ltd Subject to change