BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

Similar documents
Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Seal Kits for BUDI Enclosures

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

AMP SUPERSEAL 1.5 SERIES Connectors

Specification Control Drawing for the FIST MK2 Organizer Components

A world of fiber Product overview

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

RayClic Connection System

TE Connectivity's AMP NETCONNECT Cable Management

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Gardian W51. Approvals

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Z-PACK TinMan 85 ohm Connector Overview

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Raychem Link Boxes. Cable Services Limited. Powering the UK

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Introducing Hermaphroditic Blade and Receptacle Connector

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Specification Status: Released

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

DP86 Constant Voltage with Fitting

Cable Actuated Sensor Industrial Incremental Encoder Output

Standard and Customized Hand Tool Kits

Gas Discharge Tubes. Features: Benefits: Applications:

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Universal Connectivity Platform A Modular Approach to Infrastructure Design

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Universal Connectivity Platform

Quick Reference Guide Barrier Strips

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Ribbon Breakout Kit Installation Instructions

MSP100 Pressure Transducer

Gas Discharge Tubes GTCX28-XXXM-R05 Series

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

C A Heating Cable Gland Kit

Introducing SlimSeal SSL Connector

Introducing Inverted SMT Thru Board Connector

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

PT9150 (Extended Range)

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

Gas Discharge Tubes GTCX25-XXXM-R02 Series

MSP100 Pressure Transducer

Cable Actuated Sensor Industrial User Scalable 4 20mA

86BSD Digital Output

PT9420 (Extended Range)

Pin, Spool & Strain Insulators

Stainless Steel Cable Ties

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

Specification Status: Released

PT9600. Cable Actuated Encoder Reel. General. Environmental

86BSD Digital Output

Cable Actuated Sensor Industrial User Scalable VDC Output

89BSD Digital Output

Bridge to Splice Presser 710-BSP

Energy Division. Accessories for the Installation of Low Voltage & Medium Voltage heat-shrinkable products for the Electrical Power Industry

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Raychem Heating System

NG4access ODF Platform Standard Chassis Installation Manual

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Specification Status: Released

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

C Electrical Connection Kit

Sub psi SPECIFICATIONS

86BSD Digital Output

User s Manual and Operating Instructions

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

Introducing Low Voltage DC Grid Interconnects

FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Fiber Optic Products Catalog

OPERATION MANUAL MODEL 4610 ACCELEROMETER

OPERATION MANUAL Model 8011 & mA

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

P125 High Pressure Sensor

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

MODEL 834M1 ACCELEROMETER

MODEL 4000A & 4001A ACCELEROMETER

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

LOW PRESSURE Intrinsically Safe Transducer AST44LP

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

Specification Status: Released

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

User s Manual and Operating Instructions

Transcription:

BUDI-M-SP I N S T A L L A T I O N I N S T R U C T I O N Building distributor Introduction Suitable for FTTH applications where easily pre-connectorized splittersmodules can be build in. The box is designed In such a way that it issuitable for both spliced and connectorized solutions of the riser cable. Kit content Seals Wrap around cable seals Sealblock 6 x 10 mm Cable diameter (mm) Foam (± 5 mm) 3 95 4 90 5 80 6 75 7 70 8 60 9 50 10 40 Sealblock 6 x 15 mm Box UMS profile FAS block Blind seals Accessories Cable diameter (mm) Foam (± 5 mm) 9 125 10 115 11 105 12 95 13 85 14 70 15 60 Sealblock 3 x 20 mm Cable diameter (mm) Foam (± 5 mm) 14 155 15 140 16 125 17 110 18 95 19 85 20 75 Sealblock 24 x 7 mm Cable range A 1.8 5 mm B 5 7 mm Inline seal 1 x 18 To use in ports S6-S7 only Cable range 3 18 mm Loop bracket Loop of 8 loose tubes (ø 2.4 mm). Maximum window of 2.6 m. Standard seals PG 16 PG 21 PG 29 PG 29 (PTS 24)

1 Preparation of the box S6 S7 1.3 Use a hacksaw to reach the onion rings, which can be openedwith a plier to open the in-line ports (S4/S5). 1.1 Different wrap-around ports are available (including brackets).use two guiding pins to open the ports and to secure the bottom partto the box. Cut out the plastic part if you want to install a cable. 1.4 Install the wrap-around rubber seal into the port. 1.2 Install the cable bracket depending the cable seal. 2

2 Looped cable 2.2 Store the looped tubes into the loop bracket. 2.1 Install the looped cable into the ports. Tie wraps/ hose clamps Hook and loop fastener 2.3 Route the loose tube towards the FAS block. Foam 3

3 Drop cables Hook and loop fastener Hook and loop fastener Foam 3.2 Install the cable into the port and secure with hook and loop fastener tape ontothe bracket and seal with foam (see length page 1). 3.3 Route the fibers or tubes towards the FAS block. 4 Fiber routing 3.1 Install the drop cables into the ports. S1 S2 4 4.1 Secure the wraparound groove plate on the UMS by puttingthe plate with the long protrusions in the S1 UMS-profile and slidingthe plate in the S2 UMS-profile until it snaps. (Do not leave gapsbetween groove plates).

4.2 To remove push the two snapfits at S2 UMS-profile and slidethe wraparound plate towards S1 UMS-profile. 4.4 To remove the tray put the fiber guiding pin between lip onwraparound groove plate and tray and move lateral towards S1. 4.5 Position the wedge carefully such that the groove is stillaccessible for the fibers and be careful not to push the wedge againstfibers. To remove the wedge,use two hands to pull on both ends (nearthe groove plate). Route the fiber in the grooves of the wraparoundgroove plates to the entrance of the identified tray. Fiber must berouted in the groove below the hinge of the tray! 4.3 Place a tray in the wraparound groove plate; do this by pushingthe lip on the groove plate (lowest possible position) slightly down withthe tray and move the tray lateral into the hinge-cavities of the grooveplate. To snap the High Capacity Single Element tray (HCSE) in the W/asingle fiber groove plate leave always one hinge facility open betweenfasblock or previous tray and the HCSE-tray. 4.6 Pull gently on the fibers in the tray and make sure that the fibersare well contained in the routing block and wraparound groove plate. 5

4.7 Store the fibers temporarily on a tray (picture shows the caseof a loopback). 5.3 ANT in SC tray. 4.8 Storing dark fibers can be done in different ways. 1) Organise dark fibers into the different trays, following instructionsas described. 2) Organise dark fibers together into the first available tray (i.e. with amax. of 24cut or 12 loops primary coated fibers in one SE-tray). 5 Trays 5.4 RECORDsplice in SC tray. 5.1 SMOUV in SC tray. 5.5 RECORDsplice in SE tray. 5.2 ANT in SE tray. 5.6 RECORDsplice/ANT in SC tray. 6

5.7 Ribbon 4/8 tray. 5.8 Ribbon 12 tray. 5.9 Use a permanent marker to write on the tray. 7

6 Closing the box 6.2 Close the box. 6.1 Close all the ports. Tyco Electronics Raychem bvba Diestsesteenweg 692 B-3010 Kessel-Lo, Belgium Tel.: 32-16-351 011 Fax: 32-16-351 697 www.telecomnetworks.com www.te.com SMOUV, RECORDsplice, TE (logo) and TE Connectivity are trademarks of the TE Connectivity group of companies and its licensors. While TE Connectivity and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of theinformation contained in this catalog, TE Connectivity cannot assure that this information is error free. For this reason, TE Connectivitydoes not make any representation or offer any guarantee that such information is accurate, correct, reliable or current. TE Connectivityreserves the right to make any adjustments to the information at any time. TE Connectivity expressly disclaims any implied warrantyregarding the information contained herein, including, but not limited to, the implied warranties of merchantability or fitness for aparticular purpose. TE Connectivity only obligations are those stated in TE Connectivity Standard Terms and Conditions of Sale. TEConnectivity will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with,including, but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgment to evaluate thesuitability of a product for a certain purpose and test each product for its intended application. TC984/IP/2 03/13