Gas Temperature Measurements with High Temporal Resolution

Similar documents
Advanced Monitoring and Characterisation of Combustion Flames

µm All temperatures See surfaces through hot flue gas at 3.9 µm and better image quality than VIS 8 14 µm Best at low temperatures

An FT-NIR Primer. NR800-A-006

Time-resolved infrared imaging and spectroscopy for engine diagnostics

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Optical methods for monitoring gas turbine emissions

Mark Farries. Gooch & Housego

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

SPECTRAL INSTRUMENTATION

Mid-IR spectroscopy for flame and surface characterization. En Urga Inc

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Fundamentals of Far-infrared

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Current Research Topics in Optical Sensors and Laser Diagnostics

Band Selection & Algorithm Development for Remote Sensing of Wildland Fires

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

RAMAN SPECTROSCOPY See more, faster than ever before

Development and demonstration of a diode laser sensor for a scramjet combustor

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

APPLICATION NOTE. 1. Introduction Application Considerations

LASER SAFETY BARRIER

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

Chemical Processes in the Combustion

(4)... (1) Suggest one feature of the black fuel effect lumps which make them efficient at transferring energy....

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

Wildland fire phenomenology experiments:

Public Comment No. 3-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

Inspection Detail. General Questions for Laser Labs

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

CCTV, HOW DOES IT WORK?

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

The FEL Facility Optical Diagnostics and FEL Characterization

Emission Monitoring System

DEVELOPMENT AND FUNCTIONALITY OF SORTING SYSTEM THE POLYMARK INDUSTRIAL SCALE

Innovative Technology for Traditional and Challenging Applications

Variable Temperature Options for Optical Experiments

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Technical specifications of FT-IR Spectrometer

Pyroelectric Infrared Sensor PIR

Laser Safety Part III Administration

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

THERMAL PROCESSING THEORY

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Laser Safety Part III Administration

Imaging detection of CO 2 using a bispectral type-ii superlattice infrared camera

Measurement of Light. Photosensors

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

REVIEW ON CONDENSER AIR LEAK TEST

Technology to Application

NEED FOR LASER SAFETY

Hands-On Laser Beam Path Alignment Practical. Environment, Safety, Health & Quality Office SERF E141 Last updated: 12/28/2017

LEARNING SPECIAL HAZARD DETECTION TYPES

Rice University Laser Safety Manual

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Smart Fire Prevention

We offer ceramic radiant heaters and infra-red radiant tubes.

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

UWB Stepped-FM Sensor for Home Security

Rutgers Environmental Health and Safety (REHS)

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

Heath Consultants Overview of Infrared Optical and Laser Leak Detection Technologies in the Natural Gas Industry.

Talentum - Why use our Flame Detectors?

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

2018 New Infrared Technologies, S.L.

Industrial Fire Detection

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Atomic Absorption Spectrometer

ACTIVITIES OF THE MEASURING GROUP

Industrial fire alarm systems

Model S FT-IR SPECTROMETER

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

D-VTA 100-XX BROCHURE

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

FIRE IR SENSOR Flame Detection

Laser Diagnostics and Optical Measurement Techniques

New Technologies for Germination Testing

DUQUESNE UNIVERSITY. Laser Safety Program

Control Considerations for Safe Laser Alignment

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

Conspec - Why use our Flame Detectors

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Safety Engineering. Fire Protection Systems and Life Safety Systems

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Spectrum Detector, Inc.

Transcription:

THE GERG ACADEMIC NETWORK EVENT 2010 3 & 4 June 2010 Brussels Gas Temperature Measurements with High Temporal Resolution Supervisor: PhD Student: Dr. Alexander Fateev Vadim Evseev DENMARK

Introduction The temperature of the flue gas is an important parameter of combustion e.g. inside a boiler of a power plant cylinder of an internal-combustion engine etc. High spatial and temporal resolution is essential for accurate modeling of the process The analysis helps in further development of the models optimization of boiler/engine design etc.

Introduction Investigations under convenient laboratory conditions are not sufficient to verify the models for industrial combustors Lab Laser techniques offer great opportunities for combustion research but involve complicated and expensive set-up are demanding to alignment require more man-hours The aim of this work is to achieve high enough temporal resolution for flue gas temperature measurement to be able to apply commercially the technique on industrial scale Industry

Outline Existing methods Contact Non-contact The new system Non-contact Optics + Grating spectrometer + IR Camera Application on the industrial boiler Measurement of the flue gas temperature with high temporal resolution Future of the system Multichannel spectrometer 2D Tomography of a flame

Thermocouples Any junction of dissimilar metals will produce an electric potential related to temperature. Voltage A metal Another metal t ºC inexpensive can measure a wide range of temperatures very simple setup reliable results A thermocouple measures its own temperature. It gives somewhat integrated temperature of what it is in contact with. Response time: 15 60 s.

Contact Methods Suction pyrometers thermocouple as a temperature sensor radiation shield to avoid radiation from walls cooling water to avoid radiation from the shield itself suction of the gas to enhance the contact with the thermocouple Boiler wall Insertion Probe Flame Water Cooling Water Cooling Suction of gas Voltage Radiation shield Thermocouple Response time: 15 60 s Unable to resolve fast temperature fluctuations A risk of catching a particle (like small piece of coal or wood) Resulting in false temperature reading

Spectroscopy I 0 λ Sample gas at T [K] I λ Absorptivity: How much of incident energy is absorbed at a certain wavelength λ? α ( T) = λ I 0 λ I 0 λ I λ However each sample also emits radiation by means of thermal radiation: R ( T) λ spectral radiance [ W / (m 2 sr m) ] How does the sample having temperature T emits radiation at a certain wavelength λ? Sample gas R λ (T) Kirchhoff established: The relation is a universal function of λ and T independent of a particular sample Rλ( T) univ = Rλ ( T) α ( T) Planck derived that function: at T [K] Temperature can be calculated from measured R univ λ ( T) λ c 1 = πλ 5 c2 / λt e ( 1) spectral absorptivity spectral radiance

Non-Contact Methods Insertion Probe + Spectrometer: Easy to apply on industrial scale when compared to laser-based techniques Boiler wall Insertion Probe Flame Water Cooling Water Cooling Optical Fibre Ceramic Protection Tube Field Of View Spectrometer Spectral Radiance of the Gas Calculations t, C Temporal resolution is determined by the spectrometer Fourier Transform Infra Red (FTIR) spectrometer: 2 Hz Still not enough to resolve fast temperature variations

IR Emission Spectrum 25 20 CO 2 Blackbody A typical IR emission spectrum of exhaust gas 15 Intensity 10 5 0 H 2 O CO Greybody (particles) C x H y CO 2 H 2 O H 2 O 2000 2500 3000 3500 4000 4500 5000 5500 Wavenumber, cm -1

A New System IR Camera Grating Spectrometer Optical Fibre Source IR Image IR Spectrum 512 pixels Exposure time: down to 7 µs 640 pixels

Industrial Boiler The boiler of a biomass-coal power station Thermal picture of the 40 MW flame

Temperature Variations: A Straw Region Near the Burner Outlet Gas Temperature [ C ] Particles Temporal resolution: 1 khz Time [ms]

Temperature Variations: A Straw Region Near the Burner Zoom In: 1kHz is enough to resolve temperature variations in the flame Gas Temperature [ C ] Particles Temporal resolution: 1 khz Time [ms]

Temperature Variations: Above the Straw Region Here gas temperature is higher than that of particles. Most of heat is already released at this point, and hence gas is hotter than particles Gas Temperature [ C ] Particles Temporal resolution: 1 khz Time [ms]

Temperature Variations: Above the Straw Region Zoom In: Particles do not undergo as huge temperature variations as gases do Gas Temperature [ C ] Particles Temporal resolution: 1 khz Time [ms]

Multichannel IR Spectrometer A multichannel assembly allows to perform spectral measurements simultaneously from several line of sights IR Camera Optical fibre Grating Spectrometer IR Image Slit 12 mm 0.55 mm Simultaneous spectral measurements

2D Tomography of hot gases On-line 2D visualisation Distribution in a section of Temperatur e Concentration 2D Tomography of hot gas in an exhaust pipe shows distribution of temperature or gas concentrations in a pipe cross section

The Flat Flame Burner To develop tomography tools we need a burner producing a stable, flat flame with known temperature profile

The experimental setup An optical setup with CaF 2 lenses is used instead of optical fibers to improve the performance of the spectral measurements Optical Setup Blackbody IR Camera Grating Spectrometer Grating Spectrometer Optical Setup IR Camera

Conclusions Temperature and concentrations of combustion gases can be measured from their emission spectra e.g. spectrum of hot CO 2 can be used for the measurements of flue gas temperature Grating spectrometer + IR Camera is a smart solution to provide spectral measurements with high temporal resolution possibility of commercial applications on an industrial scale This system provides high flexibility and is promising in further developments simultaneous spectral measurements at several lines of sight 2D Tomography of hot gases and flames