Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

Similar documents
ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

GAS DETECTOR TUBE SYSTEM. The Gastec Detector Tube System represents cutting edge technology and is used in a wide variety of fields.

GAS DETECTOR TUBE SYSTEM

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Dräger Pac 7000 Single-Gas Detection Device

Xgard. Fixed detectors For flammable, toxic or oxygen gases

SP-220. Features. Combustible handheld gas leakage detector

TM-802 Formaldehyde Meter User s Manual

OLC(T) 100 FIXED GAS DETECTOR

MICROpeL 75 Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

3M Oldham OLCT 100. Description. Fixed Gas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

PROTÉGÉ ZM SINGLE GAS MONITOR

Dräger Pac 8000 Single-Gas Detection Device

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Sieger Apex. Flexibility that meets your requirements

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

THE MARINE SUPPLY COMPANY WITH A 4 HOUR RESPONSE GUARANTEE

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Dräger Pac 5500 Single-Gas Detection Device

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

AMMONIA DETECTION BY LASER THE NEXT GENERATION OF AMMONIA DETECTION

Low mg/m

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

APPLICATION DATA SHEET

Understanding the practicalities of using gas detectors in confined spaces

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

MERIDIAN UNIVERSAL GAS DETECTOR

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger Pac 8500 Single-Gas Detection Device

Vacuum and Compressor Systems for the Chemical Process Industry

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

G-TECTA TM. Portable Gas Detection Instruments

Dräger Pac 6000 Single-Gas Detection Device

ALTAIR 5X Multigas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Setting the alarms in electrochemical sensor equipped toxic gas instruments

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Properly calibrating catalytic bead sensors: A practical guide

43 May cause sensitisation by skin contact. 67 Vapours may cause drowsiness and dizziness.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

ALTAIR 5X Multigas Detector Product Specification

IRceL CH4 Methane (CH 4

Dräger Pac 3500 Single-Gas Detection Device

Dräger X-pid 9000 / 9500 Multi-Gas Detection

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Monitores Personales. Personal Monitor

ASSEMBLY & OPERATING INSTRUCTIONS

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

SC-01 Operator s Manual

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

GS100M Gas Detection Controller

FACT SHEET Program: Lab Fire Safety

Monitoring for Toxic VOCs in Oil Industry Applications

99 Washington Street Melrose, MA Phone Toll Free Visit us at

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Operation Manual R205BV, R209BV

MSA XCell Sensors. Because every life has a purpose

Frequently Asked Questions

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

LABORATORY SAFETY SERIES: Flammables & Explosives

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

Electron Microscopy Sciences

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1

Open Liquid Calibration Baths

Portable Gas Detection Practice

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Structural Fires: Selected Guidance from NYS Department of Health

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

The Cameron Clean Room

P R O D U C T D ATA S H E E T

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Corporate Profile Arjay Engineering Ltd.

What are the four things that must be present at the same time to produce fire?

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Material Safety Data Sheet

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Selecting Gas Detectors for Confined Space Entries

Transcription:

Whilst gas detector tubes are one of the most straight forward forms of gas detection, we often find ourselves answering your questions. So we thought that it would help if we published these questions that will also help others. Gas detector tubes are easy to use, are low cost, and the method is intrinsically safe, allowing it to be deployed in all industries. Because detector tubes don t require calibration, users see the benefits of this technology over electronic gas detectors due to their ease of use. Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time. Gas detector tubes are perfect for any newcomers to gas detection or for those who are looking for a cost effective solution to gas detection where they don't know what hazardous substances are present. What is the purpose of gas detector tubes? The gas detector tube system is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The majority of activities that the detector tube system is used for is to carry out spot sampling e.g. to check the level of hazardous gas within a container that has been unloaded from a ship or for determining the level of hazardous gases present on-site. It is not advised to use detector tubes for personal safety as they don t provide an alarm or warning system. What are gas detector tubes? Gas detection or gas detector tubes as they re known are glass tubes that are filled with chemical reagent that absorbs and reacts with the target gas or vapour being measured as part of a gas detection programme. A colorimetric stain (a colour change) is created. For most detector tubes, the concentration is read directly from the measurement scale on each tube. The detector tube system is comprised of a handheld air sampling pump and detector tubes. How do detector tube system technologies vary? Gastec and Drager tubes use the same colorimetric technology where the chemical reagent in the gas tube reacts to the gas sample as it is drawn through the tube. The main difference between Gastec and Drager is the gas sampling pump technique. Gastec utilises an effective piston style pump that requires minimal effort which pulls air through the detector tube. The gas detector tube fits in one end of the Gastec pump. At the other end of the Gastec pump there is a small handle that comfortably fits between your middle and index finger. This is pulled up to draw the sample and clicks once the sample is complete. Drager utilises a bellow style pump (shaped similar to a stapler). When the bellows are released, the air is drawn and the gas sample to be measured is sucked through the detector tube in use.

How is gas detected using the gas detector tube system? The detector tubes are generally supplied in packs of ten, and are sealed at both ends. In operation, the tips are broken off using a tube tip breaker, a neat function often within the hand pump or otherwise sold as a separate item. Gas detector tubes are used with a handheld air sampling pump. Depending on the manufacturer, the pump utilises either a bellows or piston design. The pump connects to one end of the detector tube and the user draws a sample of 50ml or 100ml of ambient air. As the gas sample works its way up the tube towards the sampling pump, it reacts with the chemical reagent within the tube. The colour stain produced is proportional in length to the concentration. By using a calibration scale printed on the tube, the concentration may be read immediately, without the need for laboratory analysis. The point where this reaction stops is easily read off against markings on the gas detector tube. What range do the detector tubes measure at? For many gases and vapours, there are several concentration ranges available (ppm, %, Mg/m3, mg/l) giving you the flexibility to measure both low and high concentrations without sacrificing precision. Which gases do detector tubes detect? Gas detector tubes are available to measure more than 500 different kinds of gases and vapours including the following: Acetaldehyde Acetic Acid Acetone Ammonia Benzene Bromine Carbon Dioxide Fluorine Formaldehyde Hydrogen Hydrogen Chloride Hydrogen Cyanide Hydrogen Sulphide MEK-Methyl Ethyl Ketone Mercaptans Nitrogen Dioxides Oxygen Phosphine Styrene Sulphuric Acid Toluene Xylene

What do the most popular detector tubes test for? Hydrogen Sulphide and Carbon Monoxide are our most popular detector tube types. There are 7 variations of Hydrogen Sulphide detector tubes within the standard tubes classification. The main difference being the range at which they detect. All standard detector tubes are priced at the same price no matter the detection range. There are 8 different Carbon Monoxide detector tube range types. Do detector tubes offer STEL and TWA readings? Short Term Exposure Limit (STEL) STEL detector tubes accurately measure gas concentration for occupational hygiene and compliance with laws and guideline standards. The short term tubes account for the lion share of available tubes (standard tubes). Time-Weighted Average (TWA) TWA tubes provide gas samples for up to eight hours. The direct-reading, length-of-stain tube shows immediate results and is often worn in a lapel for the duration of the shift/working day. TWA tubes eliminate laboratory turnaround time and allow you to correct worker exposure problems faster. Do short term gas detector tubes comply with standards? Yes, European Standard EN1231 specifies performance requirements and test methods under prescribed laboratory conditions for length-of-stain detector tubes and their associated pump (detector tube measurement system) used for short term measurements of the concentration of specified chemical agents in workplace air. What are the benefits of gas detector tubes? Detector tubes are most effective for accurate on-the-spot measurements Relatively inexpensive Intrinsically safe method, allowing them to be deployed in all applications where some gas detectors cannot How much does the gas detector tube system cost? Following the initial one-off outlay of purchasing an air sampling pump for about 200, the only ongoing cost is for gas tubes. The gas detector tubes are low cost with a pack of 10 tubes costing in the region of around 30. Look out for suppliers that offer detection tubes at one consistent price which makes it easier for procurement processes. Contact a1-cbiss for latest prices and availability.

Where are detector tubes used? The gas detector tubes are used by a number of different job roles for various gas detecting activities. Hazardous Materials Response Clean-up of Spills Wastewater Treatment Plants Refineries Leak Detection Marine and Shipping Pharmaceutical Chemical & Fertilizer Fumigation Food & Beverage Industry Power & Steel Plants Municipal Corporations Oil & Gas Product FAQ s Do I need to perform a pump leak test before using the pump and how do I do this? It is very important to always do a leak test every time you are using an air sampling pump to ensure that you get accurate readings. You can do this, by confirming that the inlet clamping nut is firmly tightened. After confirming that the pump handle is fully in (therefore, the guide line on the pump shaft is not seen), insert a fresh unbroken detector tube into the rubber inlet of the pump. Align the guide mark (red line) on the back plate and the guide mark ( 100) on the handle. Pull out the handle fully along the red guide line on the pump shaft to the lock position, and wait 1 minute. Unlock the handle by turning it more than 1/4 turns and guide it back gradually. Confirm the handle returns to the initial position and the guide line on the pump shaft is not seen. When the handle is unlocked, be sure to guide it back gradually by applying a little resistance. Otherwise, the handle will spring back due to the vacuum in the pump cylinder and possibly damage internal parts. What to do when my tube shows a blurry result after doing a test? Sometimes you are encountered with a blurry discolouration of the chemical reagent in the tube. In this case, always take the average between the two points where it ended. Is it possible to mix the use of gas detection tubes from different brands of air sampling pump? Whilst it is not recommended, it is possible.

How do I store and dispose of the tubes? To maintain the high quality of Gastec detector tubes, it is necessary to store them in a cool (0 to 10ºC), dark place out of direct exposure to sunlight as this may cause some chemicals to degrade. Never store the tubes in temperatures above normal room temperature. Always keep them in a safe place out of the reach of children. As detector tubes contain sensitive reagents that are ready to react, and some reagents might be corrosive, care should be taken for their storage and disposal. Used or date expired tubes (break off ends of out of date tubes if required) should be immersed in a large quantity of water (as a rough guide no more than 20 tubes per 5 litres of water) and left for several hours, preferably overnight. The tubes can then be disposed of with other broken glass. The water can be flushed down the drains as the amount of reagents is so minimal that this procedure poses no threat to personnel or the environment. What should I do when a tube breaks and my hands touched the chemical powder reagent inside the tube? Always immediately wash your hands, and never rub your eyes or touch your mouth before doing this. Can I still use the tubes when their expiry date has been expired? No, to avoid the risk of getting unreliable measurements, we definitely discourage the use of expired tubes. What is the shelf life of the Gastec detector tubes? Detector tubes have up to a 3 year shelf life (depending on the reagent if kept refrigerated). The use by date is printed clearly on the front of the packet of the detector tubes. Please inform us at point of purchase if you require a long shelf life. a1-cbiss employ a stock rotation policy of first in, first out. What is included with the purchase of a Gastec detector tube system? The Gastec pump kit includes: Protective carry case, Gastec pump, instruction manual and replacement filters Detector tubes packs include: Instruction sheet, numbered stickers. Pack details display: Batch number, number of tubes included and valid until date Do you have a question about gas detector tubes? Contact a1-cbiss to see how we can help

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.