Ultraviolet Disinfection Systems

Similar documents
Ultraviolet Disinfection Systems

Customized Drinking Water

Ultraviolet Sterilizers

Owner s Manual. Installation, Operation and Maintenance. SPV-200, SPV-410, spv-600, spv-740, spv-950

HF Series R_RevB

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

1020 Industrial Drive, Orlinda, TN fax

The reference standard in UV Proven, validated treatment solutions for disinfection and taste & odor control

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

254 Nanometer Germicidal UV Disinfection Systems

Ultraviolet Water Sterilizer Installation and Maintenance Manual

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

TROJANUVSWIFT SC. Drinking Water Treatment

Professional Amalgam Non-regulated

OWNERS MANUAL. Operation & Installation Instructions

Operation & Installation Instructions

Operation & Installation Instructions

PRO Series PRO10 PRO20 PRO30

Section 3: Ultraviolet - UV

OWNERS MANUAL. Operation & Installation Instructions.

Owner s Manual. Installation, Operation and Maintenance. SC200-DWS11, SCm200-DWS11. Manufactured in Canada by:

ADVANCE Ultraviolet (UV) Water Treatment System

Operation & Installation Instructions

Owner s Manual. Powered by. Models: NSF Standard 55 Class B Validated Models: S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, S2Q-P/12VDC, S5Q-P/12VDC

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Ultraviolet (UV) Water Treatment System

Owner's Manual. Models: 400-USUV-10, 400-USUV- 20, 400-USUV-30. Visit us online at Powered by

OWNER S MANUAL Operation & Installation Instructions

Ultraviolet (UV) Disinfection System Model RC8

Owner s Manual. Models: PUV -7 PUV -14

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

Owner s Manual. Models: Plus Models: PRO Models: Powered by H, K H+, K+ PRO10, PRO20, PRO30, PRO _RevAB

ULTRAVIOLET WATER TREATMENT

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

uv and ozone for commercial pools

WEDECO Quadron UV System

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

CHUGGER PUMP Chugger Max Models

Owner s Manual. Model: Powered by. D4, E4, F4 + Models: D4+, E4+, F4+, E4-50+, F4-50+ Validated Models: D4-V, E4-V, F4-V D4-V+, E4-V+, F4-V+

(UV) - R830F & ) INTRODUCTION

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

A measured step forward

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

ULTRA-VIOLET STERILIZATION

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

Customer Manual. MADE IN USA Effective

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

"QT" Drinking Water Systems With Quick Twist Cartridges & Membranes

instant hot water dispenser filter system système de filtre sistema de filtro owner s manual manuel d utilisateur manual del usuario

HOW YOUR UV DISINFECTION WORKS

Introducing Culligan Twin HE. The smartest way to fix hard water problems.

Installation, Operation and Maintenance Manual

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

INSTALLATION & MAINTENANCE

Model gffoz Process Ozone Sensor (In-Line)

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

Ballast MIN A

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Owner s Manual. Model: Powered by. D4 Premium, E4, F4 + Models: D4+, E4+, F4+, E4-50+, F4-50+ Validated Models: D4-V, E4-V, F4-V D4-V+, E4-V+, F4-V+

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

LS Condensate Removal Pump Installation, Operation and Service Instructions

EXCALIBUR SOFT-TEC - PRETREATMENT CHEMICAL REMOVAL SYSTEM AND WATER CONDITIONER SCALE CONTROL SYSTEMS

Installation, Operation and Maintenance Manual

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

EV Series INSTALLATION & OPERATION MANUAL

Document No E1 Revised February Atlantic Ultraviolet Corporation

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Owner s Manual. Models: Powered by PRO PRO R_RevC

Ultraviolet Air Disinfection Equipment

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

'W' HATENBOERWATER Fresh In water since l906.

SLT-Series Installation and maintenance instructions

Model CWA200 Owner s Manual

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

PCR UV cabinets DNA/RNA

PurTest PT Series INSTALLATION & OPERATION MANUAL

Installation and Maintenance Manual

Hydroflo INSTALLATION & OPERATION MANUAL

Owner s Manual. Healthy, clean and safe. Installation, Operation and Maintenance

Transcription:

Systems tested and certified by NSF International against NSF/ ANSI Standard 55 for disinfection performance, Class A. Distributed by: GREAT LAKES INTERNATIONAL, INC. 1905 Kearney Avenue; Racine, WI 53403 USA Ph: 262.634.23.86; 800.357.8538 Toll-Free U.S. Fax: 262.634.6259; 888.700.6114 Toll-Free U.S. Ultraviolet Disinfection Systems

Who is VIQUA - a Trojan Technologies Company VIQUA is a leading water treatment technology company focused on providing our customers residential and light commercial confidence in their water. Offering a complete solution package including UV disinfection, water filtration, softeners and ozone products. What is UV? Ultraviolet (UV) light is at the invisible, violet end of the light spectrum. The water treatment industry uses a high-powered form of UV light called UV-C or germicidal UV to disinfect water. How does UV light work? UV-C rays penetrate microorganisms and destroy their ability to reproduce, effectively rendering them harmless. It s a simple but effective process, destroying a minimum of 99.99% of harmful microorganisms, including E. coli, Cryptosporidium, and Giardia. Not only is it safe and highly effective, UV does not change the taste, color, or odor of water. It simply removes the risk of illness caused by microbial contamination, making water safe. Why not use chlorine? Chlorine changes the taste and odor of water. Chlorination may also produce harmful by-products that are linked to the incidence of cancer. Who uses UV disinfection systems? For more than 30 years, institutions, consumers and businesses have relied on VIQUA s environmentally friendly UV technology to disinfect their water supplies. Top candidates for UV disinfection systems include: Rural homes and cottages Nursing homes Hospitals Schools Hotels Restaurants Resorts and holiday camps Community water systems Ensuring the safety of your water. UV disinfection for drinking water is an acceptable alternative disinfectant under the drinking water regulations worldwide, as long as the equipment has proof of performance (third party validation). NSF is a certified testing facility that conducts UV validations under the NSF 55 Class A protocol. Sterilight SPV systems have undergone validation with NSF and hold certification to deliver an accepted dose of 40 mj/cm 2. Systems tested and certified by NSF International against NSF/ ANSI Standard 55 for disinfection performance, Class A.

Safety-Loc Lamp Connector The interlock switch easily allows users simple, safe lamp removal without the use of special tools. Ports For ease of installation [all point-of-entry systems]. Flow-Pace UV Sensor This UV sensor promises system stability and long-life reliability with low power consumption, reduced operational costs and less heat transfer into the water. Axial Flow Sterilight Platinum reactors include a patented axial flow system installed at the inlet. The axial flow directs water entering the chamber to the most intense area of UV light ensuring water confidence each and every time. Electropolished and Passivated Reactor Chamber Manufactured from 316L stainless steel.

Platinum ICE Controller > graphic interface (Smart Switch ) > universal power (100-250V) > visual elapsed time meter (counts down remaining days between lamp changes and provides for total running time of controller) > visual UV intensity output in % > constant current output > full system diagnostic check on start-up > dry contacts (for solenoid etc.) > universal IEC power input connector Sizing Your System The UV dose delivered by a given reactor is dependent on many factors, including water quality and flow rate. NSF/ANSI Standard 55 requires that the UV system deliver a minimum UV fluence of 40 mj/cm 2 at the alarm setpoint. The accompanying graph shows how the delivered fluence will be affected at varying UV transmittance levels.

Press to Scroll Through Information Screens Appuyer pour faire défiler les écrans d information Electronic ICE Controller / Contrôleur Électronique ICE Input Voltage 100 250V~ 50/60Hz / Tension d'alimentation 100 250 V~ 50/60 Hz Max. Input Current 1.3A, Operates one, Sterilume 15W 100W, High Output UV Lamp Maxi. d alimentation 1,3 A, Pour une lampe UV Sterilume 15 W 100 W, flux élevé intensité For Indoor Use Only / Pour utilisation à l'intérieur seulement Case Must Be Grounded / Le boîtier doit être relié à la terre For Use In Permanently Connected Equipment Only / Pour utilisation seulement dans un équipement connecté en permanence Disconnect Power Before Servicing / Débrancher l alimentation électrique avant d exécuter les travaux. Danger - High voltage electrical shock hazard DO NOT OPEN / Tension électrique élevée risque de choc électrique NE PAS OUVRIR Caution - See owner s manual before installation / Attention - Voir le manuel de l utilisateur avant d installer Patent Pending Brevet demandé 510275 00 2:00 PM TIME OF DAY Typical Point-of-entry Illustration Water Quality Guidelines Iron: < 0.3 ppm (0.3 mg/l) Hardness: < 7 gpg (120 mg/l) Turbidity: < 1 NTU Manganese: < 0.05 ppm (0.05 mg/l) Tannins: <0.1 ppm (0.1 mg/l) UV Transmittance: > 75% Lamps Sterilume HO lamps utilize low pressure high output technology in order to deliver superior performance. All SPV lamps include the following: > Proprietary lamp coating > Consistent UV output > Superior cold water start conditions > One year warranty VIQUA - a Trojan Technologies company offers a wide range of certifications, both electrical and microbiological, throughout the Sterilight product line. VIQUA cannot warranty any system or system components if non-genuine parts are used, specifically lamps. Getting genuine ensures maintenance of your system warranty, electrical certification and NSF 55 validation. Ensure the performance, safety and

General Chamber Material Electropolished & Passivated UV Intensity Monitor Flow Pacing Sensor Elapsed Time Meter Countdown Total Hours Controls Flow Restrictor Dry Contacts Lamp Replacement Reminder Diagnostic Check Operating Parameters Maximum Operating Pressure Minimum Operating Pressure Pressure Drop at Rated Flow Ambient Water Temperature Maximum Ambient Temperature Installation 316L SS 8.62 bar (125 psi) 1 bar (14.5 psi) 0.3 bar (4 psi) at 50% rated flow* 2-40 C (36-104 F) 50 C (122 F) Horizontal or Vertical 1 Rated flow at dose of 40 mj/cm 2 SPV-200 spv-410 spv-600 spv-740 spv-950 9.9 lpm (2.6 gpm) (0.5 m 3/ /hr) 22.6 lpm (5.9 gpm) (1.3 m 3/ /hr) 32.7 lpm (8.6 gpm) (1.9 m 3/ /hr) 42.9 lpm (11.2 gpm) (2.5 m 3/ /hr) 56.6 lpm (14.9 gpm) (3.4 m 3/ /hr) Electrical Voltage 100-250V/50-60 Hz Power Consumption 35 W 52 W 73 W 88 W 110 W Lamp Watts 30 W 45 W 65 W 80 W 100 W Dimensions Reactor Controller Shipping Weight Inlet/Outlet Port Size 45 cm x 9 cm (18 x 3.5 ) 5.4 kg (12 lbs) 1/2 MNPT 67 cm x 9 cm (26 x 3.5 ) 6.8 kg (15 lbs) 86 cm x 9 cm (34 x 3.5 ) 8.2 kg (18 lbs) 1 Flow rates stated as determined by NSF/ANSI Standard 55 testing. Warranty 100 cm x 9 cm (39 x 3.5 ) 8.6 kg (19 lbs) 121 cm x 9 cm (48 x 3.5 ) 9.5 kg (21 lbs) The Sterilight Platinum Series systems come with a seven year warranty against manufacturer s defects on the stainless steel reactor chamber; a one year warranty on lamps, sleeves, and UV intensity monitors; and a five year pro-rated warranty on all other components. NSF/ANSI Certification Standard 55 Class A Other Certifications * pressure drop due to flow restrictor Systems tested and certified by NSF International against NSF/ANSI Standard 55 for disinfection performance, Class A.