Underground carpark ventilation

Similar documents
INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

GreenJet Transfer Fans

GreenPark. GreenJet Throw Performance

SMOKE CONTROL - NEW DIRECTIONS

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Tunnel Axial Flow Fan

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Case Study 1 Underground Car Park

technical specification smoke venting systems

Technical Information

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Technical Assignment 3 11/15/04. Executive Summary

City of Duluth Festival Center 04/25

Systemair product news - Fans NEWS

Introduction to Fans. The Basics of Fan Principles and Terminology

Electrostatic Air Cleaners for Commercial and Industrial Applications

Car Park Ventilation 1

Colt ventilation systems for car parks, loading bays and service areas

Impact of Minimum Fan Efficiency Grade. Dr. John Cermak Executive Vice President ACME Engineering and Manufacturing Corp.

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

EHH SERIES DRAW THROUGH FAN COILS CFM

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

How to ensure Thermal Comfort in buildings with CFD

AXIAL & JET FANS FOR TUNNEL VENTILATION

AMCA Webinar High Performance Air Systems Presented by:

KOMFORT EC DB Suspended heat recovery air handling units

Myth & Reality of Basement Ventilation

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Roof top SPACE RPC 450Z R407C M011

Fan Selection. and Energy Savings

Roof top SPACE RPC 315Z R407C MA00

Design And Analysis Of Centrifugal Pump

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

UNIJET CAR PARK VENTILATION SYSTEM

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Tunnel Fire Dynamics and Evacuation Simulations

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Fans: Features and Analysis

Indirect Gas-Fired Make-Up Air

Specialized in the design and the tailor-made production of dryers, coolers and thermal processing equipment for industrial use.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

FAN WALL Technology. Product

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

KIC Air Curtains. Technical Guide

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

CONVENIENT FEATURES ...MORE PERFORMANCE LESS... SPACE ENERGY NOISE G-TEC BELT-DRIVEN ROTARY SCREW AIR STATION. 7.5 to 22 kw 8 to 13 bar

SIMPLICITY FULL MODULARITY?

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION

MacroAir AirElite HVLS Fans

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Lo-Carbon Sentinel Kinetic Horizontal

Rotary Screw Compressors ASD Series

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

USING A REAL TIME SIMULATOR IN A LARGE AND COMPLEX ROAD TUNNEL FOR TIME AND COST SAVINGS

SIMPLICITY OR FULL MODULARITY?

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Considerations in the Design of Smoke Management Systems for Atriums

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

A Novel Approach for the Thermal Management. of PC Power Supply

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Caution: The fans must not be used in bath or shower enclosures.

Mixing Technologies Solutions for Flue Gas Desulfurization

XC10 combined fire detection and extinguishing control

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Analysis of ventilation system for a microwave assisted drying unit

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

intelligent solutions

Selecting the Correct Fan

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

PFS Single stage axial fan The axial fan for modern boiler plants

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Glossary of Terms Laboratory & Fume Exhaust Fans

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

Experience In Motion. SIHI Multi Modular Multistage Pumps

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

DACC Health Sciences Building Air Handler Assessment/Study

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

TUNNEL FANS STANDARD AND HOT SMOKE

Aspirating Gas Detection CFD Modelling Predicts Application Performance

XC10 combined fire detection and extinguishing control

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Transcription:

Underground carpark ventilation High efficiency & flexible systems www.lti.com.sg

Car Park Ventilation About Us LTi Ventilatoren, we deal in indoor air quality (IAQ), an important ingredient of life from past 10 years. With the long history & experience of manufacturing of ventilation products with our colleagues having more than 30 years of experience, LTi Ventilatoren have been able to setup several production plants across the globe. Our long experience & efforts we put into our R&D, we are successfully able to develop new innovative products with higher efficiencies & low noise levels. Our name LTi, L-Long term T-Technical i-innovative, supports our concept of continuous growth with our technical innovations on our existing product range & to develop new products for ever growing markets. Our wide product range includes Axial fans, Bifurcated axial fans, belt driven axial fans, Jet fans, centrifugal fans, In-line fans, mixed flow fans, special application fans for chemical resistance & battery room applications. Our customers are in domestic sector, commercial sector, industries, power sector & infrastructure of ventilation market. LTi Ventilatoren (Asia) Pte Ltd, established to support local market by producing complete range of fans with national/international technologies to serve our customers locally & globally. Our experience in the ventilation systems give our customers confidence to have most efficient/economical solutions for their ventilation requirements. This confidence in LTi & its high quality products is backed by excellent pre/after sales services by our experienced sales & technical staff. We provide complete solutions to ventilation problems arising from air & sound. With this catalogue of fans, we provide our customers the complete overview fan range LTi can offer to the market. For further detailed discussions & information kindly feel free to contact our local sales company/distributor/dealer worldwide. Quality standards Our focus is customer satisfaction, which comes through with best quality & accurate deliveries. We believe in quality products. Our products have been tested & endorsed in Singapore by PSB (Productivity& standard board) & AMCA Singapore. All performances are in accordance to AMCA standards for air & sound. For high temperature fans we follow BS/EN standards for different temperatures & time classifications. *No liability for errors! - Subject to technical modifiocation 2

Our Projects Project Title: ITE College & HQ @ AMK Consultant: Kajima Fan supplied : Axial, Cabinet & MIL Project Title: The Estuary Contractor: Great Resources M&E Contractor Pte Ltd Fan supplied: Axial, Cabinet & CIL Project Title: Suki Sushi Contractor: Natural Cool Airconditioning & Engineering Pte Ltd Fan supplied: Axial, Cabinet, CIL & Propeller Project Title: Central Fire Station Contractor: BNF Engineering (S) Pte Ltd Fan supplied: CIL & Propeller Air Movement and Control Association International, Inc. Certifies that LTI Ventilatoren (Asia) Pte Ltd Having satisfied the membership requirements, has been granted membership in the Air Movement and Control Association International, Inc. Member Since February 2011 AMCA International President Acting Executive Director 3

Car Park Ventilation Ductless jet ventilation the basics Need Jet fans systems has been developed to ventilate underground cark parks for both CO removal during normal conditions & extracting smoke during emergency situations. These both requirements can be handled by single system more effectively & economically i.e. jet fan ductless car park ventilation systems. The complete system is consists of Jet fan, main axial fans for extract & fresh air. Normally fresh air fans are designed for the basements where there is not enough of natural cutouts e.g. ventilation shafts or ramps. In addition to fans a unique control system i.e. designed to specific project, where the signals from CO / heat/smoke sensors operate the system at different speeds according to the need of situation & save energy. To design an efficient system we need to involve with the designers quite well in advance for suggesting the openings in the basement for an efficient fresh air intake & proper CO/ smoke removal. Fans are normally designed on the basis of air exchange rates for both normal & emergency applications. The local codes or building regulations plays vital role in designing the air flows, control systems & zones in the basement. The jet fans work at different operating conditions pending on the signals from the CO sensors giving possibilities to save energy working on demand ventilation principle. Jet fans can be controlled individually or together as a group of fire zones. During fire operations complete system including main fresh air, extract air fans & jet fans run at full speed for cleaning the basement from smoke efficiently and quickly. Advantages The jet fan system has its own advantages over conventional ducted systems, As system doesn t need ducts it allows the structure to have smaller heights appx 0.5m to 0.75m lesser than normal basements. Ductless system is easy to install in shorter time compare to conventional, expensive & complex ducted systems. It means saving on installation time & cost. Jet fan systems is easy to maintain & an ideal solution for renovations for the car parks. It is possible to operate systems in parts/zones as per signals given from CO/smoke sensors. As air is free to move in specified directions given by the jet fans, air mixer is proper in all the layers & provide better air quality in the basements compare to conventional ducted system. Jet fan systems allow CO & smoke extraction removal as one system with maximum level of automation & highly efficient. CO sensors ensure that only fans in the polluted zones to run. Smoke sensors decide that system should start in full swing once signal given to the controlling device. Elimination of ducts in systems give less resistance to the main fans resulting in lesser static pressure i.e. lower motor KW of the fans. Very flexible in positioning of jet fans in the car park. Low height of the jet fans allow the cark park to be more neat & clean giving possibility to monitor the basement with help of CCTVs In case of smoke extraction, the high efficiency of the system provide the rapid & optimum smoke control e.g. smoke removal, smoke cooling & restricted smoke spread. Jet fan systems also prevents expensive structural damages in emergency fire conditions by providing proper mixing of fresh air & quick removal of smoke from the basement. This limits the heat exposure to ceilings/slabs. System requirements Jet fans system design needs jet fans based on the area of the basement. Main fresh air fans (where cut outs are not sufficient) & extracts fans for both CO & smoke removal. The capacities of the main extract fans based on the air changes. International codes refer 4-6 ACH for CO removal & 8-10 ACH for smoke extraction. Control system is the heart of the system & need to be designed carefully. The control system decides the response time for the speed of the jet fans after getting signals from CO sensors. This helps the complete system to optimize the energy at different parking loads of the day. Which means the control system will start/stop the fans individually or zone wise pending on the demand of the cark park. When connected to the fire detection or in high CO levels, the controlling device need to switch on the fans on full speed after getting the signal from heat/smoke sensor or CO sensor. In addition to switching jet fans on high speed on fire floor, the control system is also responsible to switch off fans on other levels upper or lower than the fire floors. Control system will also regulate the main supply / extract fans on demand or signal from the respective sensors in addition to jet fans, quickly & effectively. 4

CFD Simulation Computational fluid dynamics (CFD) can simultaneously predict airflow, heat transfer and contaminant transport in and around buildings. A CFD model is built upon fundamental physical equations of fluid flow and energy transfer. The technique is capable of providing time dependent and as well as steady state solutions to the coupled differential equations that govern fluid flows. The jet fan ventilation system is adapted for the basement ventilation in normal operating conditions as well emergency operating conditions. The objective of the CFD is to design of ventilation system for the basement car parking area using jet fans. The specific aim is to find the optimal locations, number & configuration of the jet fans required for the ventilation of the car parking lot, for the given positions of inlets and exhaust, and given configuration of the exhaust fans, such that it meets requirements of CO exposure limit set by health and safety regulations. The acceptance criteria within the Building Regulations adopt the Health and Safety Executive, EH40/2000 Occupational Exposure Limits 2000. The main criterion is for car parks the carbon monoxide levels are to remain below a designated peak value. The input to the project shall be the data and information provided by the client in form of 2-D Layout drawing of Basement and check list duly filled in the format given by the supplier. The mathematical modeling for the analysis involves a few simplifying assumptions and care shall be taken to be sufficiently conservative with the assumptions to meet the safety requirements. The Positioning of the JET Fans shall be based on CFD analysis to transport fresh air from supply points to the all the place through jet fan and hence forth to the Extract fan which will extract the air out of the Basement. Processes involved in CFD When applying a CFD package to undertake a flow and thermal analysis, there are number of steps that involved for completing the CFD process. Defining the geometry and domain Selecting physical sub-models Specifying boundary conditions at the frontiers of the domains including walls, inlets, openings, supply fans, exhaust fans, jet fans, and fire location and burning material properties. Discretizing the mathematical equations, which includes creating a mesh (which sub-divides the space into small volumes), setting time steps (which divides the time into discrete steps) and selecting numerical sub-models Monitoring the iterative solution process Analyzing the solution obtained Uncertainties that may arise at each of these steps are highlighted Visualize the obtained solution Control system Designing of a control systems is an important aspect of the system which needs to be done at the initial design stage itself. Determining the type/ quantity of sensors and deciding the zones and configuring them right is an integral part of the control system design. We, at Sevcon-Lti, design much complex control system in a way that is easy to control and operate. Intelligent controls & monitoring The system can be controlled and monitored in a more intelligent way by using smart controllers and sensors. With the latest innovative technology the Sensors are connected through a digital bus to the controllers that helps saving in wiring and offers a dedicated multifunctional approach to regulating and controlling ventilation equipment. Utilizing reliable electrochemical sensor technology, a number of digital BUS CO Detectors may be zoned to measure CO and control ventilation. In this way, energy costs can be streamlined while operating effective air quality control. Please be in touch with Sevcon-Lti team for details. 5

Car Park Ventilation CFD simulations CFD Simulation Section velocity vectors We assist our customers in proper design of basement ventilation system using jet fan systems with the help of CFD (Computational fluid dynamics). CFD analysis reports are provided on request to find the optimal locations, numbers, size & configuration of the jet fans required for the ventilation of the car parking lot, for the given positions of inlets and exhaust, and given configuration of the exhaust fans, such that it meets requirements of CO exposure limit set by health and safety regulations. Mean age of air 6 Influence of drop beams

JAF Series -Jet Fan Dual use: For daily ventilation and smoke extraction in case of fire F300 (300 C/120 min.). Aerodynamical impellers for maximum thrust and with low sound level. Motors IP54, insulation class H (smoke extract); motors IP55, insulation class F (CO-exhaust). Casing manufactured from galvanized steel. Removable fan module also after installation for easy maintenance. Certified to BS 7346: Part 2/EN 12101-3 Technical data: Jet fan JAF Thrust Air volume Motor rated power Motor rated current Speed Sound level 1m, from center of casing 400V/50Hz/3~ N m³/h kw A rpm LpA db kg Weight Temperature JAF 315-2 31 5400 0.75 1.7 2845 64 60 55 C JAF 315-2/4 31/9 5400/2700 0.8/0.16 1.9/0.4 2730/1375 64/47 60 55 C JAF 355-2 51 7200 1.5 3.2 2840 66 70 55 C JAF 355-2/4 51/11 7200/3600 1.7/0.37 3.5/0.8 2870/1435 66/50 75 55 C JAF 400-2 81 10400 2.2 4.4 2840 70 85 55 C JAF 400-2/4 81/17 10400/5200 2.4/0.48 4.9/1.4 2900/1450 70/54 110 55 C JAF 315-2(T) 31 5400 0.75 1.7 2845 64 60 300 C/2h JAF 315-2/4(T) 31/9 5400/2700 0.8/0.16 1.9/0.4 2730/1375 64/47 60 300 C/2h JAF 355-2(T) 51 7200 1.5 3.2 2840 66 70 300 C/2h JAF 355-2/4(T) 51/11 7200/3600 1.7/0.37 3.5/0.8 2870/1435 66/50 75 300 C/2h JAF 400-2(T) 81 10400 2.2 4.4 2840 70 85 300 C/2h JAF 400-2/4(T) 81/17 10400/5200 2.4/0.48 4.9/1.4 2900/1450 70/54 110 300 C/2h Dimensions: Size Da H E C F L M 315 419 430 265 235 315 1660 355 355 459 497 305 255 355 1820 355 400 504 558 350 280 400 2000 400 All dimensions in mm. 7

Car Park Ventilation CJF Series- Jet Fan Technical data: For normal ventilation and smoke extraction in case of fire F300 (300 C/120 min.). Aerodynamical centrifugal impeller for maximum thrust and with low sound level. For normal ventilation motors are IP55, insulation class F, For smoke extraction motors are IP54, insulation class H. Suitable for low ceiling heights. Galvanized steel casing. Deflectors for adjusting flow. Certified in accordance to BS 7346:Part 2. Centrifugal Jet Fan CJF Thrust Air volume Motor rated power Motor rated current Speed Sound level 1m, from center of casing 400V/50Hz/3~ N m³/h kw A rpm LpA db kg Weight Temperature CJF 50-4/8 54/12 5900/2900 1.39/0.37 3.2/1.36 1450/725 74/58 86 55 C /300 C/2h CJF 100-4/8 90/21 11500/5750 2.2/0.55 4.4/1.3 1440/720 69/55 145 55 C /300 C/2h Dimensions: Model A B C D E F CJF 50-4/8 1250 775 271 70 836 930 CJF 100-4/8 1700 1150 340 70 1206 1300 8

JVF Series -Jet fan Nozzle type fan for normal ventilation for car parks. 220 V/50 hz Single phase, normal temperature. Simple wiring, easy installation, maintenance free. Low Power consumption, ultra thin, low noise level. Simply suspended from the ceiling with hanger bolts. Lubrication free motor bearings require no maintenance. Technical data : Models No Item Unit JVF-350AX JVF-450AX JVF-550AX JVF-650AX 1 Nozzle EA One nozzle One nozzle One nozzle One nozzle 2 Nozzle Dia mm 180 250 250 300 3 Air Flow CMH 1,500 2,300 2,500 3,500/6,800 4 Phase Ph 1 1 1 1/3 5 Voltage Volt 220 220 220 220/380 6 Cycle Hz 50 50 50 50 7 Revolution RPM 2,850 2,850 2,850 2,850 8 Ampere Amp 0.8 2.0 2.5 2.8 9 Power consumption Watt 175 350 500 1,200 10 Sourd Level db(a) 55 61 63 60/67 11 Weight KG 16 25 28 35 Dimensions: H d Model L d D A B C E F H JVF-350AX 1060 180 280 285 130 320 190 250 600 JVF-450AX 1220 250 360 320 210 330 240 320 750 JVF-550AX 1320 250 360 370 210 330 240 320 750 JVF-650AX 1560 300 440 500 190 310 320 380 800 9

Car Park Ventilation System Operation: The Jet fan system shall consist of jet fans at strategic locations based on CFD analysis, CO sensors and control & power panel. The control panel shall provide power to Jet fans & CO sensors and shall switch on & off the jet fans based on demand. CO sensors shall be placed at different locations in basement and also the Jet fans will be located at strategic locations. Set of jet fans shall run based on Start/stop command from control panel based on signal from CO Sensors. The CO level will be sensed by the CO sensors and the signal will be relayed to control panel. Control panel shall decide to run set of jet fans based on signal provided by CO sensors. In case of fire: Co Sensors operation shall be bypassed. The signal from fire alarm panel shall be sent to jet fan panel. Jet fan panel shall start jet fans in higher speed. The Main extract fans to achieve required Air change shall also receive a signal from fire arm panel/detection system & run them in case of fire. Main Incomer 3 phase output to jet fans Control Panel Input from Multiple CO sensors Input from fire detection system 10

Input required for conducting the CFD Analysis Project Name & Location: Customer: Basement Level: Basement Area (Sq Mt): Basement Height (Mt): No. of Cars: Jet Fans details Jet Fan Model: Air Volume ( CFM): Thrust ( N): Single speed or Dual Speed: Unidirectional or bi directional: To be used for Smoke extract / CO extract: Supply & Exhaust fan details Parameter Supply Air Exhaust Air Total Air Qty (CFM) Type of fan ( axial/centrifugal) Air Qty (CFM) per fan Qty of Fans Location (s) of fans (s) in Drawing Corresponding File name & format If Natural, provide Size (Mt.) and Location of the opening in Drawing Provide relevant floor plans of the car park: Provide relevant sectional drawings plans of the car park: Normal Mode Fire Mode Normal Mode Fire Mode We hereby confirm that details provided above are correct and final for proceeding with the CFD. Date: Name & Signature of the Sender: Name of the Organisation: 11

LTi Ventilatoren (Asia) P/L 19, Jln Mesin. Singapore 368818 Tel. : +65 65646678 Fax : +65 65646166 mail : sale@lti.com.sg *subject to technical modification