Edition: September 2011 Order no inter. Operation Manual Neutralisation Systems GENO -Neutra NO-5 GENO -Neutra NO-12 GENO -Neutra NO-24

Similar documents
Operation Manual Neutralisation Systems GENO -Neutra N-14 GENO -Neutra N-70 GENO -Neutra N-210

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

SUN EQUINOX HEATING SYSTEMS

VETO CLEANER 500 FLUE GAS CLEANER

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and maintenance instructions

TTV 4500 / TTV 4500 HP / TTV 7000

Waste water ejection unit

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Friwa Compact. Operating instructions EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Operating instructions

INSTALLATION AND OPERATING INSTRUCTIONS

Operating Manual. VIENNA Hot Display

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Instruction manual. Water treatment Boiler system D 30 L

AUTOMATIC GRANULAR ICE FLAKER

Installation and maintenance instructions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

3-way switching valve

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Operating instructions

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

Hand Dryer Installation & User Manual

DUST EXTRACTOR MODEL No: CDE1000

AC THOR. Assembly Instructions

MODULAR AUTOMATIC GRANULAR ICE FLAKER

TDS 20 R / TDS 30 R / TDS 50 R

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

USER S MANUAL ATH WH220

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

HKF 8180 Operating instructions

GLEB Kitchen exhaust fan

Tornado Operations & Maintenance Manual

User and maintenance manual

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Test Unit GTL 100 for Fire Detectors

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Installation and Operating Instructions. Models: T4-12LOW-9IS-1

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operation Manual 322 KL

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

BarAid 400. Installation and. Starting from Serial No.:

SILENT compact /

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

AS 50 operating manual, 2013

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Glass and Dishwashers AMX / AUX Series

Operating and Maintenance Instructions

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

AUTOMATIC ICE-CUBE MAKER

Product Manual Glue Applicators MS 80 and MS 200

Moisture inside the drum is due to final testing.

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

RX550i Electric Pressure Washer

PAC 2000 E OPERATING MANUAL LOCAL AIR CONDITIONER TRT-BA-PAC2000E-TC EN

Operating Instructions. Rotating Vacuum Filter Type VRF

Light oil burners. One stage operation

Glass and Dishwashers AMX / AUX Series

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Aluminum Heating Mantles

Instruction manual ASPIMAX 16

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Operating instructions

Service: to SLK Laboratory Hot Plates glass made of ideas

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Operating instructions

Mechanical seals external, single or double, to DIN EN 12756

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

AUTOMATIC MODULAR ICE FLAKER

Procedure for the Approval of New Fire Detection and Alarm Technologies

Propane Heater REMKO PGM 30 REMKO PGM 60

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Commercial backpack vacuum cleaner

VIESMANN. Operating instructions VITODENS 111-W. for the system user

90cm Chimney Extractor

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

Transcription:

Edition: September 2011 Order no. 015 410 850-inter Operation Manual Neutralisation Systems GENO -Neutra NO-5 GENO -Neutra NO-12 GENO -Neutra NO-24

Table of contents A General... 4 1 Preface 2 Warranty 3 General safety information 4 Shipping and storage 5 Disposal of used parts and materials B Basic information... 8 1 Laws, regulations, standards 2 Gas condensing technology 3 Neutralisation 4 Obligatory neutralisation as per ATV-DVWK-A 251 C Product description... 10 1 Type designation plate 2 Designated application 3 Design 4 Function 5 Scope of supply 6 Technical specifications D Installation... 20 1 General installation instructions 2 Sanitary installation - Installation instructions 3 Start-up E Troubleshooting... 25 F and care... 27 1 Basic information 2 3 4 Spare parts list Appendix: Operation log 2

EC Declaration of Conformity This is to certify that the system designated below meets the safety and health requirements of the applicable European guidelines in terms of its design, construction and execution. If the system is modified in a way not approved by us, this certificate is void. Manufacturer: Responsible for documentation: System designation: System type: Grünbeck Wasseraufbereitung GmbH Industriestraße 1 89420 Hoechstaedt/Germany Markus Pöpperl Neutralisation system System number: 410 230, 410 240, 410 250 Applicable EC guidelines: Applied harmonised standards, in particular: Applied national standard and technical specifications, in particular: EC Guideline EMC (2004/108/EC) EC Low Voltage Directive (2006/95/EC) RoHS (2002/95/EC) DIN EN 61000-6-2, DIN EN 61000-6-3 DIN EN 60335-1, 60335-2-102, DIN EN 62233 1st Ordinance to the Device and Product Safety Act (Ordinance on the Marketing of Electrical Operating Materials to be used within specific voltage limits 1. GPSGV). ATV- DVWK-A 251 (08/03); DVGW-VP 114; E DIN 4716-2 (04/03); E DIN 4716-1 (11/98) Date / Manufacturer signature: 07/03/2011 i. V. Markus Pöpperl Dipl.-Ing. (FH) Function of signatory: Head of Design Department for Serial Products 3

A General 1 Preface Thank you for opting for a Grünbeck product. Backed by decades of experience in the area of water treatment, we provide solutions for all kind of processes. All Grünbeck systems and devices are made of high-quality materials. This ensures reliable operation over many years, provided you treat your water treatment systems with the required care. This operation manual assists you with important information. Therefore, please read the complete manual before installing, operating or maintaining your system. Customer satisfaction is our prime objective and providing customers with qualified advice is crucial. If you have any questions concerning this device, possible extensions or general water and waste water treatment, our field staff, as well as the experts at our headquarters in Hoechstaedt, are available to help you. Advice and assistance For advice and assistance please contact your local representative (refer to www.gruenbeck.com). or get in touch with our service centre which can be reached during office hours: Phone: +49-9074/41-333 Fax: +49-9074/41-120 Email: service@gruenbeck.de We can connect you with the appropriate expert more quickly if you provide the required system data. In order to have the required data handy at all times, please copy it from the type designation plate to the overview in chapter C-1. 2 Warranty All devices and systems supplied by Grünbeck Wasseraufbereitung GmbH are manufactured according to the most recent technical standards and subjected to a comprehensive quality assurance system. All warranty claims are subject to our General Terms and Conditions. 4

3 General safety information 3.1 Symbols and notes Important information in this operation manual is characterised by symbols. Please pay particular attention to this information to ensure the hazard-free, safe and efficient handling of the system. Danger! Failure to adhere to this information will cause serious or lifethreatening injuries, extreme damage to property or inadmissible contamination of the drinking water. Warning! Failure to adhere to this information may cause injuries, damage to property or contamination of the drinking water. Attention! Failure to adhere to this information may result in damage to the system or other objects. Note: This symbol characterises information and tips to make your work easier. Tasks with this symbol may only be performed by qualified electrical experts according to the VDE guidelines or according to the guidelines of a similar local institution. Tasks with this symbol may only be performed by approved installation companies with appropriately trained experts or by Grünbeck s technical service/authorised service company. 3.2 Operating personnel Only persons who have read and understood this operation manual are permitted to work with the system. The safety guidelines are to be strictly adhered to. 3.3 Designated application The system may only be used for the purpose outlined in the product description (chapter C). The present operation manual, the applicable local guidelines as well as the guidelines on accident prevention and occupational safety must be adhered to. In addition, appropriate application also implies that the system may only be operated when it is in proper working order. Any malfunctions must be repaired at once. 5

3.4 Indication of specific dangers 4 Shipping and storage Danger! Due to electrical energy! Do not touch electrical parts with wet hands! Pull out power plugs and disconnect the power supply to external system parts (e.g. voltage-free outputs) before working on electrical system parts! Have qualified experts replace damaged cables immediately. Warning! Health risk due to acidic condensed water and alkaline neutralisation granulate! Avoid direct contact by means of corresponding protective measures such as protective gloves and goggles. First aid provisions in case of contact with the eyes: In case of contact with the eyes, rinse thoroughly with water and seek medical advice if irritation persists. Hygienic provisions: Do not eat, drink or smoke while working! The current safety data sheet on neutralisation granulate must be observed. You may order said safety data sheet from Grünbeck Wasseraufbereitung GmbH. Please indicate the corresponding product designation and order number (refer to consumables chapter C-5). Attention! Condensed water or neutralisation granulate may damage surfaces when covering them. Attention! The system may be damaged by high temperatures. In order to avoid damage of this kind: Do not install or store the system next to objects which radiate a lot of heat. The system may only be transported and stored in its original packing. Ensure that it is handled with care and placed down with the right side up (as indicated on the packing). The neutralisations granulate GENO -Neutralit Hz is not considered to be a hazardous material in the sense of the Ordinance on Hazardous Substances. Please observe the current safety data sheet. The activated carbon is not considered to be a hazardous material in the context of the Ordinance on Hazardous Substances. Please observe the current safety data sheet. 6

5 Disposal of used parts and materials Used parts and materials are to be disposed of or made available for recycling purposes according to the applicable local guidelines. If a material is subject to specific regulations, adhere to the instructions indicated on the packing and in the safety data sheets. If in doubt, contact your local waste disposal authority or the manufacturer for more information. The used activated carbon filling of the condensate inlet filter should be disposed of under waste code number 190904 through a local waste management company. Neutralisation granulate (waste code number 01 01 02) as delivered may be disposed of with the domestic waste after prior consultation with the responsible waste management company and the authorities and taking into consideration the applicable regulations. When cleaning the system, hydroxide sludge may be generated which has to be collected separately and disposed of in a suitable, separate container at the local point of acceptance. In the declaration, it may be classified as "metal-containing hydroxide sludge (waste code number 100121). The respective latest version of the TA- Abfall (Technical Regulation on Waste) must be observed. 7

B Basic information 1 Laws, regulations, standards This operation manual takes into consideration the current regulations and stipulates information that you will need for the safe operation of your water treatment system. Apart from the public rules and regulations, the following supporting regulations apply for the treatment of condensed water originating from condensing boilers and its discharge into the public sewage system. Worksheet ATV-DVWK-A 251 Condensate from condensing boilers (ATV-DVWK Body of Rules Registered German Association for Water Management, Waste Water and Waste). E DIN 4716-1 "Neutralisation systems Part 1: Oil-firing systems and their flue gas systems." E DIN 4716-2 "Neutralisation systems Part 2: "Gas firing systems and their flue gas systems." DVGW-VP 114 "Neutralisation systems for gas firing systems; requirements and testing." 2 Gas condensing technology In case of gas condensing boilers, the residual heat still contained in the flue gas is made use of by means of heat exchangers in order to achieve an optimum efficiency. Due to the low temperature of the exhaust, the water contained condenses. In order to comply with the applicable regulations, however, this kind of condensed water must in general be treated prior to being discharged into the public sewage system. 3 Neutralisation According to the worksheet ATV-DVWK-A 251, the term "neutralisation" in context with the treatment of condensed water originating from condensing boilers is defined as follows: Increase of the ph value of the acidic condensed water to a value of more than 6.5. 8

4 Obligatory neutralisation as per ATV-DVWK-A 251 Excerpt derived from chapter 4.1.3 of the current August 2003 edition Nominal heat output Neutralisation for firing systems and motors without catalytic converter is required for Gas Heating oil DIN 51603-1, low on sulphur Heating oil DIN 51603-1 < 25 kw no 1), 2) no 1), 2) yes 25 up to 200 no 1), 2),3) no 1), 2),3) yes kw > 200 kw Yes yes yes However, a neutralisation is nevertheless required 1) if the domestic waste water is discharged into small sewage plants, 2) in case of buildings and lots whose drainpipes do not meet the material requirements stipulated in paragraph 5.3, 3) in case of buildings which do not meet the requirements for sufficient blending as per paragraph 4.1.1. 9

C Product description 1 Type designation plate The type designation plate is located at the housing of the neutralisation system. In order to speed up the processing of your inquiries or orders, please specify the data shown on the type designation plate when contacting Grünbeck. Please copy the indicated information to the table below in order to have it readily available whenever necessary. Neutralisation Systems Serial number: / Order no. (NO-5) 410 230 Order no. (NO-12) 410 240 Order no. (NO-24) 410 250 2 Designated application GENO -Neutra NO-5, NO-12 and NO-24 systems are designed for the neutralisation (increase of the ph-value to more than 6.5) of condensed water originating from oil- and gas-fired heat generators (condensing boilers) and/or exhaust systems made of stainless steel, plastic, glass, graphite and ceramics according to ATV-DVWK-A 251, DIN 4716-1, DVGW-VP114 and DIN 4716-2 up to the specified capacity. Concentrations of manganese, aluminium and zinc contained in the condensate may clog the neutralisation granulate and therefore considerably affect the function of the neutralisation system. If need be, the applicability should be checked by means of tests and if necessary, regular cleaning of the system with replacement of the granulate must be arranged for. Condensed water may also contain impurities, combustion residues and also unburnt hydrocarbons or oil, amongst other things, when operating the system with oil. These are retained by the condensate inlet filter integrated into the system inlet. We recommend with a gas condensing boiler operated in gas / oil switching mode or with increased dirt content (e.g. the dirt ingress above the chimney) that you install an additional condensate pre-filter in the inlet hose to the neutralisation system. 10

This is because experience has shown that with a condensing boiler operated in gas / oil switching mode, deposits may detach from pipes and other components when switching over to gas and be flushed into the neutralisation system as a result of the higher specific condensed water volume with gas (0.14 l/kwh with gas, 0.08 l/kwh with oil). The system may only be operated if all components are installed properly. Safety devices must NEVER be removed, bridged or otherwise tampered with. Designated application of the system also implies that the information contained in this operation manual and all safety guidelines applying at the installation site be observed. Furthermore, the maintenance and inspection intervals have to be observed. 11

3 Design The neutralisation system consists of a neutralisation tank with hose connections for inlet and outlet. In the neutralisation tank, a sedimentation zone for impurities, a zone for activated carbon filling and neutralisation granulate filling with an aeration device and a collection zone for condensed water are aligned in direction of the flow. An overflow orifice is mounted above the outlet piece so that the condensate may exit the system at a predefined place in case the condensate outlet is clogged. The neutralisation system can be equipped with an optional overflow warning switch - refer to accessories. The aeration pump is fixed to the outside of the neutralisation tank with a band clamp and connected to the outlet system with a hose and non-return valve. A siphon with a trap seal depth of 46 mm is integrated into the inlet connection for the NO-5 system. The NO-24 consists of two NO-12 systems switched in series that are connected with a hose section. 12

1 Tank 2 Plugs 3 Nuts 4 Seals 5 Angle-type hose connection 6 Lid 7 Outlet system for NO-5 8 Non-return valve 9 Aeration pump 10 Band clamp 11 Clamping pin Fig. C-1: Position drawing NO-5 13

1 Tank 2 Outlet system for NO-12 3 Lid 4 Y-piece 5 Non-return valve 6 Aeration pump 7 Band clamp 8 Clamping pin Fig. C-2: Position drawing NO-12 14

1 2 x compact system NO-12 2 Hose clamp 3 Connecting hose Fig. C-3: Position drawing NO-24 4 Function The condensed water flows into the sedimentation zone of the neutralisation system. The condensed water is then distributed via the integrated filter plates and flows through the activated carbon and neutralisation granulate filling. The granulate is thus solubilised and the condensed water neutralised. The aeration device reduces iron deposits in the process. Afterwards, the condensed water flows to the drain. The quantity of neutralisation granulate included in the scope of supply corresponds to the initial filling required at maximum capacity. The ph value of the discharged water may be checked by means of the ph indicator strip included in the scope of supply. Neutralisation granulate should be refilled before the ph value falls below 6.5. 15

5 Scope of supply Standard equipment 1 Neutralisation System GENO -Neutra NO-5, N-12 or N-24 The NO-24 consists of two NO-12 systems. 1 Plastic bag containing: 1 Connecting hose (for NO-24) 5 m hose DN 20 1 Pack of ph indicator strips 3 Hose clamps (for NO-12 and NO-5) 5 Hose clamps (for NO-24) Activated carbon filling (filled into system for NO-5) Neutralisation granulate GENO -Neutralit Hz 3 kg for NO-5 (filled into system) 8 kg for NO-12 16 kg for NO-24 1 Operation manual 1 List of authorised service companies Complete and packed in cardboard box 16

Accessories Overflow warning switch Voltage-free level switch (changeover contact) with attached flat pin bushing for electrical connection as well as fastening material for installation in the lid of the neutralisation system. Alarm delay KZL 71 Alarm delay relay in the on-wall housing, e. g. to realise a parallel or delayed switchoff of the heating boiler after an alarm has occurred. Only applicable in combination with the optional accessory "overflow warning switch" of the neutralisation system. Spiral hose DN 20, 5 m Waste water lifting system AH-300 Oil binder mats (20 pcs) Order no. 410 680 410 285 410 764e 420 150 410 585 Consumables set for NO-5 set for NO-12 set for NO-24 GENO -Neutralit Hz - 8 kg ph indicator strips - 3 pieces 410 805 410 806 410 807 410 011 170 173 17

6 Technical specifications All system data is summarised in the table C-1. The data given refers to standard neutralisation systems. Possible deviations in case of special versions are listed separately, if applicable. Table C-1: Technical specifications/dimensions GENO -Neutra NO-5 NO-12 NO-24 Connection data Power supply 230 V / 50 Hz Power input [W] 5 5 10 Protection/protection class IP X4/II Voltage-free fault contact (optional overflow warning switch) Changeover contact, switching capacity 250 V / 6 A (Ohmic load) electrical connectionflat pin bushings 6.3 x 0.8 mm Nominal diameter of inlet/outlet hose [DN] 20 Min. drain connection [DN] 40 Performance data Combustible/process (generation of condensate) Oil/gas condensing technology Max. neutralisation capacity, at 0.08 l/kwh this corresponds to a max. boiler capacity of [l/h] [kw] 4.4 55 12.8 160 25.6 320 Filling volumes and consumption data Neutralisation granulate GENO -Neutralit Hz (8 kg, order no. 410 011) Filling volume neutralisation granulate [kg] 3 8 16 Service life in case of standard condensate acc. to DIN 4716-1, ph 2 Neutralisable condensate volume This corresponds to the full load operating hours of boiler [m³] [bvh] 12 months 2.9 650 12 months 8.3 650 12 months 16.6 650 Service life in case of standard condensate, however at a ph of at least 2.5 Neutralisable condensate volume This corresponds to the full load operating hours of boiler [m³] [bvh] 12 months 6.6 1500 12 months 19.2 1500 12 months 38.4 1500 Dimensions and weights Condensate backwater height in standard operation [mm] 120 A Total height [mm] 165 B Height inlet connection [mm] 110 C Height outlet connection [mm] 110 D Length without hose connections [mm] 410 458 458 E Length with hose connections [mm] 435 469 469 F Width [mm] 268 230 460 G Overflow height (lower edge of orifice) [mm] 140 H Length with connecting hose, approx. [mm] - - 600 Operating weight, approx. [kg] 12 16 32 Shipping weight [kg] 7.5 14 28 Ambient data Condensate temperature [ C] 5-60 Ambient temperature [ C] 5-40 Test certificate/certification mark DVGW registration number DG-4585CM0232 Order no. 410 230 410 240 410 250 18

NO-5 NO-12 NO-24 Fig. C-4: Dimensional drawing 19

D Installation 1 General installation instructions Note: When installing systems with optional accessories, also observe the operation manuals that have been supplied with the optional accessories. Attention! If no floor drain is available at the installation site, an alarm device must be installed. In case of a system failure, the alarm device must visibly indicate the alarm and, if necessary by switching the heat generator, prevent the system from overflowing and consequently prevent consequential damage. For an overflow warning switch, please refer to accessories. The technical specifications of the system and the regulations for discharge to the public sewage system according to ATV- DVWK - worksheet A 251, as well as the local and general regulations must be observed. The installation site must be frost-proof and ensure the system's protection from chemicals, dyes, solvents, high radiation temperatures, dust and from direct sunlight. The installation site must provide adequate space, be level, horizontal and load-bearing and easily accessible for inspection and maintenance work. The neutralisation system is fitted with a power cable that is approx. 2 metres long (2 power cables for the NO-24) with a flat Euro plug. One or two 230 v / 50 Hz socket(s) is/are required for the electrical connection. This power connection must conduct a continuous current or be connected in parallel to the burner of the condensing boiler. Other operating modes may considerably affect the function of the neutralisation system. The required connections must be provided prior to the installation. 20

2 Sanitary installation - Installation instructions Installation and start-up may only be performed by an approved installation company with appropriately trained personnel. However, you may also assign Grünbeck's technical service/authorised service company. Take into consideration that in standard operation the condensed water is accumulated to a level of approx. the height of the outlet connection. If the condensed water shall completely drain from the heat generator or the flue gas system, the installation areas respectively the outlets for the condensed water must be provided for accordingly. A drain connection (min. DN 40) must be available for the discharge of the condensed water and discharge without backwater must be ensured. If no floor drain or drain connection close to the floor is available, the water lifting system AH-300 can be installed downstream of the system (refer to accessories). Use the hoses supplied with the system to make the connections (resp. refer to chapter C, accessories). Should additional hoses and fittings be needed, only approved, corrosion-resistant materials according to ATV-worksheet - A251 (e. g. PP, PE, PVC,...) may be used. Do not use any parts made of brass, copper or steel. Additional condensing boilers or/and flue gas systems may be integrated up to the max. neutralisation capacity by using corresponding T pieces. 21

GENO -Neutra NO-12 GENO -Neutra NO-24 The drain hose must not be connected directly to the drain pipe in order to prevent retroactive bacterial contamination from the drain to the neutralisation system (refer to Fig. D-1). Direct the inlet hose with a gradient to the neutralisation system and the outlet hose with a gradient to the drain (see Fig. D-1). Do not bend the hoses! If no siphon is available, the inlet hose must be directed to the neutralisation system with a backwater loop (refer to Fig. D-1) as well as a gradient. A siphon with a trap seal depth of 46 mm is integrated into the inlet connection for the NO-5. Therefore, no additional siphon may be available here and the inlet hose must be directed with a gradient without a backwater loop (refer to Fig. D-1). GENO -Neutra NO-12 GENO -Neutra NO-24 GENO -Neutra NO-5 Fig. D-1: Installation example 2.1 Preliminary work Unpack all system components and check for completeness (for the scope of supply, please refer to chapter C) and soundness. Select an installation site where the inlet and outlet hoses can be as short as possible. For the NO-24, connect both NO-12 systems with the enclosed connecting hose and fasten by means of hose clamps. Remove the lid of the neutralisation tank. Fill the activated carbon and neutralisation granulate acc. to Fig. D-5 and D-7. The NO-5 is already fillled acc. to D-3. If necessary, install accessories as indicated in the operation manuals that come with these systems. 22

Granulate filling level max. Activated carbon Inlet DN20 Outlet DN20 Neutralisation granulate Fig. D-2: Granulate filling level for NO-5 Fig. D-3: NO-5 Filling areas Granulate filling level max. Activated carbon Inlet DN20 Outlet DN20 Fig. D-4: Granulate filling level for NO-12 Neutralisation granulate Fig. D-5: NO-12 Filling areas Granulate filling level max. Activated carbon Neutralisation granulate Inlet DN20 Outlet DN20 Activated carbon Neutralisation granulate Fig. D-6: Granulate filling level for NO-24 Fig. D-7: NO-24 Filling areas 23

2.2 How to connect the system Strictly observe the direction of flow as well as the technical specifications! Connect the system according to the installation instructions and fasten the hoses by means of hose clamps. 3 Start-up Connect the power cable of the aeration pump(s) to the designated socket(s). This power connection must conduct a continuous current or be connected in parallel to the burner of the condensing boiler. Other operating modes may considerably affect the function of the neutralisation system. Fill the neutralisation system with water. Check the system as well as the inlet and outlet lines for tightness. Close the lid of the neutralisation tank. The system is now ready for operation. Properly instruct the user resp. the operating personnel Fill out the operation log (refer to chapter F, operation log) 24

E Troubleshooting Note: Note: Note: Even carefully designed and manufactured technical systems that are operated properly, may experience malfunctions. Table E-1 provides an overview of possible problems that may occur during the operation of the neutralisation system and indicates the causes and their elimination. Grünbeck's technical customer service/authorised service company must be notified in case of malfunctions that cannot be remedied with the information given in table E-1! When contacting Grünbeck's technical service, please indicate the system designation as well as order number and serial number. Depending on the operating conditions (season, operating hours of the burner, temperature of heat supply and return,...), the granulate consumption may vary considerably. This is normal and due to technical reasons. Clotty granulate is not considered to be a malfunction. If necessary, loosen up the clotty granulate. In general, the neutralisation efficiency is not affected by this. However, deposits of impurities contained in the condensed water may negatively affect the neutralisation efficiency. In general, this may be remedied by more frequent cleaning and renewal of the granulate (refer to chapter C-2). Only use genuine neutralisation granulate (refer to consumables)! 25

Table E-1: Troubleshooting This is what you observe This is the cause This is what to do Short-term increase of the ph value at the outlet to more than 10. Longer period of standstill. No immediate action required. Repeat the check of the ph value after a longer period of continuous operation. ph value at the outlet is below 6.5 after a longer period of operation. Neutralisation agent is used up. Granulate is clotty or clogged due to deposits. Due to longer periods of standstill, e. g. in the summer months, the granulate is caked and cured. Filter plate is dirty. Clean the system in case of severe sludge deposits (refer to maintenance). Refill granulate. Loosen the granulate by adding water, perform maintenance, if necessary. Clean the filter plates. ph value at the outlet is permanently above 10 or below 6.5. Aeration pump is not running. Coating on the neutralisation granulate, air inlet filter on the aeration pump are dirty. Outlet system is blocked. Deviating from the reference value of the design specification, highly differentiating condensed water types and condensed water volumes may occur in boiler and flue gas systems and therefore a different system size may be required. No mains voltage available. Electrical connection is defective. Aeration pump is defective. Replace the air inlet filter on the aeration pump. Clean or replace the outlet system. Adapt the system size to the inlet volume of condensed water. Check the electrical connections; replace the aeration pump if necessary. 26

F and care 1 Basic information work may only be performed by Grünbeck's technical service/authorised service company or by an approved specialist company. Danger! When performing maintenance work or when cleaning the system, pull out power plugs and disconnect the power from the inlet hose of the voltage-free contacts. Attention! Danger of water damage! Clean resp. replace damaged, old or silted hose connections. Check system for tightness. Note: Note: In order to guarantee the reliable function of the neutralisation systems over a long period of time, some maintenance work has to be performed at regular intervals. All regulations and guidelines which apply at the installation site must be strictly adhered to. The regular inspections can be performed by the operator or by a trained expert contracted by him. Initially, we recommend inspecting the system at shorter intervals and later on as required. However, an inspection is compulsory at least every six months. Depending on the impurities contained as well as the volume and the ph value of the condensed water, maintenance work has to be performed at regular intervals, at least, however, once a year, otherwise the warranty will be void. must be performed by an approved installation company with appropriately trained experts or by Grünbeck s technical service/authorised service company. In order to document the inspection and maintenance work, an operation log must be kept (for the operation log, see appendix). In the case of system failure, the operation log helps to identify possible sources of error. In addition the log documents the proper system supervision. A maintenance contract ensures that all the required maintenance work will be performed in due time. Only use genuine neutralisation granulate and activated carbon (refer to chapter C, consumables)! 27

2 3 Note: work is sensible and necessary to ensure the function of the system and to identify maintenance requirements at an early stage. A minimum of the following components should be kept in stock for carrying out an inspection (refer to spare parts). Air inlet filter for the aeration pump Oil binder mats work Check the ph value at the condensate outlet. The ph value measured must be higher than 6.5. Check the inlet and outlet lines for deposits and clean them, if necessary. Check whether there is a film of oil on the surface of the water in the neutralisation tank (not necessary when operating the system with gas). If this is the case, remove the film of oil by means of an oil binder mat. Immediately inform or consult the technical service responsible for the condensing boiler about the film of oil. Do not use any loose oil binding agents! These can lead to a blockage of the neutralisation system. Check the air inlet filter on the aeration pump for any impurities and replace if necessary. If required, refill the neutralisation granulate or perform maintenance. Check the water level in the neutralisation system and if necessary, fill with water up to the outlet level. Check the system as well as the inlet and outlet lines for tightness. Record the inspection in the operation log (refer to chapter F, operation log). A minimum of the following components should be kept in stock for performing maintenance (refer to spare parts) set Oil binder mats Outlet system (recommended) 28

work 1. Stop the occurrence of condensed water or redirect it to a suitable collecting tank. 2. Pull the power plug on the aeration pump out of the socket. 3. If the accessory "overflow warning switch" is available, de-energise it and remove it from the system together with the lid. 4. Check whether there is a film of oil on the surface of the water in the neutralisation tank (not necessary when operating the system with gas). If this is the case, remove the film of oil by means of an oil binder mat. Immediately inform or consult the technical service responsible for the condensing boiler about the film of oil. Do not use any loose oil binding agents! These can lead to a blockage of the neutralisation system. 5. Detach the air hose on the aeration pump and remove the aeration pump from the system by lifting the band clamp. 6. Remove the granulate and activated carbon separately from the system, preferably with a wet suction device, fill the plastic bag included in the maintenance set and dispose of this as specified in chapter A-5. 7. Clean the outlet system and replace it if necessary (refer to spare parts) 8. Clean the tank. 9. Check the inlet and outlet lines for deposits and clean them, if necessary. 10. Install the outlet system again. 11. Replace the connecting hose between the non-return valve and aeration pump. 12. Replace the inlet filter and aeration pump feet. 13. Install the aeration pump and connect the air hose. 14. Insert the power plug on the aeration pump into the socket. 15. Fill activated carbon and neutralisation granulate into the corresponding areas (refer to chapter D-2.1). 29

16. Fill the system with water and check the system as well as the inlet and outlet lines for tightness. 17. Close the lid of the neutralisation system again. If the accessory "overflow warning switch" is available, energise it and check the function of the alarm signal (simulate backwater). Lift the outlet hose for a short time and fill the tank with water to the level of the overflow orifice. Close the lid - the overflow warning switch must be completely inserted in the terminal screw connection. 18. Record the maintenance in the operation log (see chapter F, operation log). 19. Hand over the operation manual to the operator. 4 Spare parts Note: Note: Note: For accessories and consumables refer to chapter C. You may order spare parts, accessories and consumables from your local Grünbeck representative. Wearing parts: Various components are subject to a certain wear and tear or ageing and therefore are considered to be wearing parts. Although these are wearing parts, we grant a limited warranty period of 6 months. The same applies for electrical components. The wearing parts are indicated below (refer to the table for Fig. F-1, F-2, F-3). Aeration pump The proper function of the aeration pump depends on environmental parameters (temperature, air humidity, air pollution, etc.), whereby the wearing parts or parts in which impurities may occur need to be renewed as required. These include the membranes, filter felt and possibly the pump head if it is dirty. As extensive repair work does not generally make sense and requires expert knowledge, we recommend that the entire aeration pump is replaced in the event of system failure. We generally recommend that the aeration pump is replaced every 4-5 years to prevent any malfunctions. As a general rule, the air inlet filter must be replaced as part of a general maintenance. 30

Fig. F-1 Wearing parts on the GENO -Neutra NO-5 Pos. Notes 1 Plugs 2 Angle-type hose connection 3 Seals 4 Overflow warning switch Accessories 5 * Outlet system for NO-5 6 * Non-return valve 7 * Air inlet filter and rubber feet 8 * Hose section 9 * Aeration pump 10 * Band clamp 11 Clamping pin w/o item no. * Hose DN 20 *Wearing parts 31

Fig. F-2: Wearing parts on the GENO -Neutra NO-12 Pos. Notes 1 * Outlet system for NO-12 2 Overflow warning switch Accessories 3 * Non-return valve 4 * Hose section 5 * Aeration pump 6 * Band clamp 7 * Air inlet filter and rubber feet 8 Clamping pin 9 * Connecting hose Only for NO-24 w/o item no. * Hose DN 20 5 m *Wearing parts 32

Fig. F-3: Wearing parts for the GENO -Neutra NO-24 Note: The GENO -Neutra NO-24 consists of two GENO -Neutra NO-12 systems connected in series. Therefore the same parts can be used. 33

34

Customer Name:... Address:......... Operation log Neutralisation system System type... Order no.... Serial number:... Installation: Date:...... Company:... Phone:... Start-up: Date:...... Company:... Phone:... Connection data/ condensing boiler: Manufacturer:... Type:... Capacity [kw]:... Combustible:... Material(s) of boiler:... Material(s) of heat exchanger:... Material(s) of flue gas system:... 35

Log of proof for inspection, maintenance and repair work System type:... Order no.... Serial no.:... Work performed Execution confirmed 36

Log of proof for inspection, maintenance and repair work System type:... Order no.... Serial no.:... Work performed Execution confirmed 37

Log of proof for inspection, maintenance and repair work System type:... Order no.... Serial no.:... Work performed Execution confirmed 38

Log of proof for inspection, maintenance and repair work System type:... Order no.... Serial no.:... Work performed Execution confirmed 39