Steel Fire Sprinkler Pipe

Similar documents
TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

Model F3 Dry Sprinklers

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SECTION DRY-PIPE SPRINKLER SYSTEMS

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

FIRE SUPPRESSION SPRINKLER SYSTEM

SECTION WET-PIPE SPRINKLER SYSTEMS

Model DDX Deluge Valve

DESIGN & CONSTRUCTION GUIDELINES

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS

quick response Sprinkler 105a October 25, 2010

standard response dry horizontal sidewall sprinklers

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SPRINKLERS TABLE OF CONTENTS

esfr dry pendent sprinkler Vk501 (k14.0)

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

DIVISION 21 - FIRE SUPPRESSION

The intelligent alternative for flue gas venting systems

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

esfr dry pendent sprinkler Vk502 (k14.0)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

standard response/ quick response extended coverage

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

WET-PIPE SPRINKLER SYSTEMS

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

Solutions at every turn.

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

***Specifications***

Compressed Air Distribution System

TECHNICAL DATA. Wet 26a. February 22, 2009

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

SECTION AUTOMATIC SPRINKLER PIPING

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

TECHNICAL DATA OBSOLETE

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

2. Welding Materials and Procedures shall conform to the ASME Code.

Big-Lock Tubing. Total Solutions for Air, Vacuum and Inert Gas Systems

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

SECTION PREACTION SPRINKLER SYSTEMS

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

Care and Maintenance

DIVISION 21 - FIRE SUPPRESSION

standard response large orifice dry

Hundreds of Satisfied Customers...

Box-in-Box Cold Storage Fire Protection Options

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

A Product of Southern Steel Pipe Sdn. Bhd. The Coloured. Smartube, Your Smarter Choice!

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Worldwide Contacts.

B. Related Sections: The following Sections contain requirements that relate to this Section.

Anvil International is the largest and most complete fitting and hanger manufacturer in the world. TODAY

TECHNICAL DATA. 319a. January 27, 2012

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Viega Fire Protection Systems. Safety starts here

TECHNICAL DATA OBSOLETE

Flow Control for Fire Protection

SECTION DRY-PIPE SPRINKLER SYSTEMS

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Model F1FR Series Quick Response Standard Spray

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

TECHNICAL DATA. model c-2

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Residential Sprinkler For Sloped Ceilings

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

SECTION FIRE-SUPPRESSION STANDPIPES

FLEXIBLE CORRUGATED TUBE

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

MSC Guidelines for Automatic Sprinkler Systems

Technical Data. to the physical properties of

Environmental Health & Safety

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

Transcription:

Steel Fire Sprinkler Pipe

Wheatland Tube Fire Sprinkler Products Wheatland Tube began producing steel fire sprinkler pipe in 1931, and today offers the most complete line of products in the industry. Engineers and contractors across the continent depend on us for steel fire sprinkler pipe and a number of proprietary products always in stock and ready to deliver. 100% Compatibility We guarantee our steel pipe is 100% compatible with fire protection systems that use only steel pipe. Why risk incompatibility? Wheatland's complete line of steel sprinkler pipe makes design easy and brings you peace of mind.* Accurate and Efficient Our products help you work safer and smarter not harder. With our extensive in-house capabilities, we offer the shortest production cycle times in the industry, and we deliver to you accurately and on time, every time. * Wheatland Tube has never warranted compatibility between its steel pipe products and CPVC products. Green and Sustainable Our steel fire sprinkler pipe contains recycled steel and provides decades of reliable service. At the end of its life, the steel may be almost fully recycled, supporting your green policies. Zekelman Industries Wheatland Tube is a division of Zekelman Industries, the largest independent manufacturer of steel hollow structural sections (HSS) and steel pipe in North America. We leverage our 100-plus years of pipe and tube manufacturing experience and expertise to produce 2 million tons of pipe and tube annually. Backed by Zekelman Industries, you can count on Wheatland for strength, innovation and service bringing exceptional value to your business.

WLS 30 Light Wall A faster alternative to Wheatland's WLS 30 steel fire sprinkler pipe is a threadable, light-wall steel pipe approved for working pressures up to 300 psi. Finished in black or hot-dip galvanized When hot-dip galvanized, approved for dry system applications Available in standard or lengths; custom lengths may be ordered Saves on freight and installation costs NOM OD UL CRR* WLS WLS 10 WLS PCS. / 1 TON LIFT Pcs. / Lift PCS. / 1 TON LIFT 1 1.087 1.462 1.865 70 60 1 1/4 1.426 1.928 2.621 55 45 1 1/2 1.650 2.370 3.297 45 2 2.125 3.004 4.542 35 30 1 1.315 1.087 1.049 0.57 1.00 1.462 70 60 1 1/4 1.660 1.426 1.442 1.380 0.46 1.00 1.928 55 45 Pcs. / Lift 1 1/2 1.900 1.650 1.682 1.610 0.64 1.00 2.370 45 2 2.375 2.125 2.157 2.067 0.52 1.00 3.004 35 30 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). WLS Meets or Exceeds These Standards: ASTM A795, Type F, Grade A Hot-dip galvanized finish meets FM requirements for dry systems UL and C-UL Listed and FM Approved NFPA 13 ANSI / ASME B1.20.1 pipe threads

Mega-Flow Greater hydraulics, greater value ID up to 7% larger than 10 and 11% larger than Saves freight, labor and installation costs Standard hanger spacing (15') Available in standard lengths; custom lengths can be ordered Roll groove available from mill inventory Proprietary mill coating provides superior primer for printing Wheatland's Mega-Flow is an engineered, light-wall steel sprinkler pipe that offers ID up to 7% larger than 10 and 11% larger than for improved hydraulics. Mega-Flow saves freight, labor and installation costs with standard hanger spacing (15') and standard and custom lengths. With its proprietary mill coating, Mega-Flow is an excellent alternative to standard wall products so you can downsize your entire sprinkler system with the same or greater quality. NOM OD UL CRR* MEGA-FLOW Mega-Flow 10 Mega-Flow 1 1/4 1.530 1.108 1.904 61 1419 1622 1690 1 1/2 1.7 1.556 2.586 61 1993 2278 2373 2 2.215 1.961 3.631 37 1524 1741 1814 2 1/2 2.707 2.504 4.998 30 1578 1803 1878 3 3.316 3.349 7.090 19 1336 1527 1591 4 4.316 4.331 10.669 19 1728 1975 2057 6 6.395 8.000 21.900 10 1680 1920 2000 1 1/4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 Pcs. / Lift 1 1/2 1.900 1.7 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 2 1/2 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 0.75 1.00 8.000 10 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). Mega-Flow Meets or Exceeds These Standards: ASTM A795, Type E, Grade A UL and C-UL Listed and FM Approved for use with roll grooved, swage grooved, plain-end couplings and welded joints for wet, dry preaction and deluge systems FM Approved for roll grooved, plain-end and welded joints for wet systems NFPA 13 and NFPA 14

Mega-Thread Greater hydraulics, greater value ID 3.6% larger than Saves costs in threadable applications Superior flow characteristics Can be joined by screwed, grooved or plain-end fittings, or welded Threads smoothly and easily; requires no thread warning Proprietary mill coating extends shelf life, makes painting quicker and easier Approved for standard hanger spacing Wheatland's Mega-Thread is an engineered, light-wall steel sprinkler pipe that offers ID 3.6% larger than for superior flow. Mega-Thread saves costs in threadable applications and can be joined by screwed, grooved or plain-end fittings, or welded. With its proprietary mill coating, Mega-Thread is an excellent alternative that threads smoothly and easily so you can downsize your entire sprinkler system with the same or greater quality. NOM OD UL CRR* MEGA-THREAD Mega- Thread Mega- Thread L.W.T. Pipe * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). 1 1.087 1.462 1.865 70 2149 2456 2559 1 1/4 1.416 1.989 2.674 51 2130 2435 2536 1 1/2 1.650 2.370 3.297 44 2190 2503 2607 2 2.117 3.094 4.621 30 1949 2228 2321 Pcs. / Lift 1 1.315 1.087 1.049 1.00 1.00 0.61 1.462 70 1 1/4 1.660 1.416 1.380 1.00 1.00 0.39 1.989 51 1 1/2 1.900 1.650 1.610 1.00 1.00 0.31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 0.25 3.094 30 Mega-Thread Meets or Exceeds These Standards: ASTM A795, Type E, Grade A UL and C-UL Listed and FM Approved for wet, dry and preaction sprinkler systems FM Approved for use in wet systems Hot-dip galvanized finish meets FM requirements for dry systems NFPA 13 and NFPA 14 Rated 300 psi working pressure

GL Galvanized, Light Wall, Threadable Ideal for exposed, open areas Wheatland's GL steel fire sprinkler pipe is an OD galvanized, lighter-wall, threadable product. The nominal OD provides improved hydraulics resulting in an exceptional value. Ideal for branch line use in wet, dry, preaction or deluge systems Comparable mechanical strength to Readily paintable galvanized exterior Reduces freight and installation costs UL THREADED CRR* GL GL GL Mega- Thread 1 1.103 1.370 1.701 91 2618 2992 3117 1 1/4 1.448 1.761 2.365 61 2256 2578 2686 1 1/2 1.688 2.033 2.875 61 2604 2976 3100 2 2.153 2.686 4.142 37 2087 2385 2485 Pcs. / Lift 1 1.103 1.049 0.61 1.00 1.00 1.370 91 1 1/4 1.448 1.380 0.39 1.00 1.00 1.761 61 1 1/2 1.688 1.610 0.31 1.00 1.00 2.033 61 2 2.153 2.067 0.25 1.00 1.00 2.686 37 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). GL Meets or Exceeds These Standards: ASTM A795, Type E, Grade A for fire sprinkler applications up to 300 psi working pressure UL and C-UL Listed and FM Approved for wet, dry and preaction deluge systems FM Approved for use in wet systems Threaded and welded fittings are approved in accordance with NFPA 13

MLT Black, Light Wall, Threadable A smooth, customized look Wheatland's MLT is a black-coated, light-wall engineered product, with a nominal OD and reduced wall thickness that provide improved hydraulics. Ideal for previously installed systems and expansions Saves freight and installation costs As mechanically strong as pipe Easily paintable for a customized look Can be used in wet, dry, preaction and deluge systems Can be joined with threaded couplings, roll grooved or plain-end couplings, or welded UL THREADED CRR* MLT MLT MLT * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). MLT Meets or Exceeds These Standards: ASTM A795, Type E, Grade A for fire sprinkler applications up to 300 psi working pressure UL and C-UL Listed and FM Approved for wet, dry and preaction deluge systems FM Approved for use in wet systems Mega- Thread Threaded and welded fittings are approved in accordance with NFPA 13 1 1.103 1.370 1.701 91 2618 2992 3117 1 1/4 1.448 1.761 2.365 61 2256 2578 2686 1 1/2 1.688 2.080 2.875 61 2604 2976 3100 2 2.153 2.630 4.142 37 2087 2385 2485 Pcs. / Lift 1 1.103 1.049 0.61 1.00 1.00 1.370 91 1 1/4 1.448 1.380 0.39 1.00 1.00 1.761 61 1 1/2 1.688 1.610 0.31 1.00 1.00 2.033 61 2 2.153 2.067 0.25 1.00 1.00 2.686 37

10 and High quality, high performance Wheatland's 10 and steel fire sprinkler pipe are subjected to the toughest possible testing to ensure the highest possible quality not to mention reliable, long-lasting performance. Proprietary mill coating ensures clean, corrosionresistant surface Outperforms and outlasts standard lacquer-coated pipe Easily painted, without special preparation Available with hot-dip galvanizing Also available in black WEIGHTS AND DIMENSIONS NOMINAL SIZE OD SCHEDULE in. Wall Inches Wt. lbs. / ft. Wt. / Ft. O Filled 1 1.315 0.133 1.68 2.055 1 1/4 1.660 0.1 2.27 2.922 1 1/2 1.900 0.145 2.72 3.602 2 2.375 0.154 3.66 5.109 2 1/2 2.875 0.203 5.80 7.871 3 3.500 0.216 7.58 10.783 3 1/2 4.000 0.226 9.12 4 4.500 0.237 10.80 16.311 5 5.563 0.258 14.63 23.262 6 6.625 0.280 18.99 31.498 10 and Meet or Exceed These Standards: ASTM A135, Type E, Grade A ( 10) ASTM A795, Type E, Grade A ( ) UL and C-UL Listed FM Approved NFPA 13 1 1/4 1.442 1.807 2.514 61 2315 2645 2756 1 1/2 1.682 2.087 3.049 61 2673 3055 3183 2 2.157 2.6 4.222 37 2051 2344 2442 2 1/2 2.635 3.534 5.895 30 2226 2544 2651 3 3.260 4.336 7.949 19 1730 1977 2060 4 4.260 5.619 11.789 19 2242 2562 2669 5 5.295 7.780 17.309 13 2124 2427 2529 6 6.357 9.298 23.038 10 1953 2232 2325 8 8.249 16.960.086 7 2493 2849 2968 SCHEDULE 10 NOM OD NOMINAL WALL NOMINAL WEIGHT UL PIECES in. mm in. mm in. mm lbs. / ft. kg / m CRR* Lift 1 1/4 1.660 42.2 1.442 36.6 0.109 2.77 1.81 2.69 7.3 61 1 1/2 1.900 48.3 1.682 42.7 0.109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 0.109 2.77 2.64 3.93 4.7 37 2 1/2 2.875 73.0 2.635 66.9 0.120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 0.120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 0.120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 0.134 3. 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 0.134 3. 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 0.188 4.78 16.96 25.26 2.1 7 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). SCHEDULE NOM OD NOMINAL WALL NOMINAL WEIGHT UL PIECES in. mm in. mm in. mm lbs. / ft. kg / m CRR* Lift 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.50 1.00 70 1 1/4 1.660 42.2 1.380 35.1 0.1 3.56 2.27 3.39 1.00 51 1 1/2 1.900 48.3 1.610.9 0.145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.45 1.00 30 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0).

WST 5 Light Wall A high-strength, light-wall sprinkler pipe Wheatland's Super Tube (WST) is a light-wall 5 product that's UL and C-UL Listed, and FM Approved for use with standard roll grooved and welded joining methods. Finished in black Large ID for better hydraulics and downsizing tubing requirements 1 1.185 0.869 1.346 91 1661 1898 1977 1 1/4 1.530 1.108 1.904 61 1419 1622 1690 1 1/2 1.770 1.275 2.3 61 1633 1867 1944 2 2.245 1.605 3.319 37 1247 1425 1485 Super lightweight Outstanding hydraulics Fast installation Approved for use with flexible pipe couplings for the roll grooved joining method High corrosionresistance ratios Standard hanger spacing NOM OD UL CRR* WST WST WST * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded steel pipe is used as the benchmark (value of 1.0). The average CRR values shown above are higher than any threaded sprinkler pipe (except 2). WST's larger ID can often lead to superior hydraulics and down-sizing of pipe systems. Pcs. / Lift 1 1.315 1.185 1.049 2.17 1.00 0.87 91 1 1/4 1.660 1.530 1.380 1. 1.00 1.11 61 1 1/2 1.900 1.770 1.610 1.11 1.00 1.27 61 2 2.375 2.245 2.067 0.90 1.00 1.60 37 WST Meets or Exceeds These Standards: ASTM A795 / ASTM A135 UL and C-UL Listed and FM Approved New York City MEA #259-91-M Dade County, Florida, 92-1210

700 South Dock Street Sharon, PA 16146 800.257.8182 info@wheatland.com wheatland.com Corporate Office 227 West Monroe Street Suite 2600 Chicago, IL 60606 312.275.1600 info@zekelman.com zekelman.com About Wheatland Tube Wheatland Tube, a division of Zekelman Industries, produces a wide range of steel tubular products, including standard steel pipe, galvanized mechanical tubing, fence framework, fire sprinkler pipe, electrical conduit, elbows, couplings and nipples. For more information, contact Wheatland Tube at: 800.257.8182 or info@wheatland.com Or, visit our website at wheatland.com Follow us on: twitter.com/wheatlandtube linkedin.com/company/zekelman-industries youtube.com/zekelmanindustries wheatland.com/blog WFS-031518