PRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW

Similar documents
PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

Storage systems. Solarbayer. Fire protection insulation ISO B1

Storage systems. Warmth for coziness. New: HSK SLS. We develop for your future. System technology made in Bavaria

PRODUCT INFORMATION. Satellite collector NANOSOL. Solarbayer GmbH (29.14) 1

Installation instructions

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Buffer Tank FWSS 1000 V7-RH

ECOplus Solar Cylinder

Installation and operating instructions. DK energy storage and DK energy buffer

Flat plate collector SILVERSUN Mounting instruction Please read carefully before installation. Solarbayer GmbH [21.14] Solarbayer GmbH 1

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Installation manual Operating instructions

TERMO Combi Cylinder TECHNICAL INFORMATION

In cooperation with. sustainable energy solutions

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Technical information for installation and operation

Waste water ejection unit

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

sustainable energy solutions

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Mounting instruction Please read carefully before installation

Wood log boiler HVS. Solarbayer Gasifying wood log boiler. Ecological hea ng with highest comfort! HVS E ECONOMIC HVS LC.

Storage tank size Rated volume [l] Actual volume [l]

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

Installation, Operating and Servicing Instructions

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

SUN EQUINOX HEATING SYSTEMS

Installation, Operating and Servicing Instructions

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

CIRCO 6 Solar Circulation Unit

STORAGE WATER HEATERS

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Manual. Above-counter dispenser for hot drinks OTHG /12

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Pro-Clean Stratified Tank scope of delivery:

INDIRECT WATER HEATERS

Installation and instruction manual SOLAR STATION

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

using Solar energy efficient efficiency rate

Akva Vita Instantaneous water heater

Instruction manual ASPIMAX 16

OPERATION INSTRUCTION

ADVANCE ELECTRIC THERMAL STORE

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

CAS; -S; -B; -BS TECHNICAL MANUAL HEATING TECHNIQUE. for instalation, use and maintenance of the water accumulation tanks

Friwa Compact. Operating instructions EN

Product news 2018/19. Heat pump system WIKOSOL HPS. Tank for wall boiler WBO TN. Vacuum tube collector WIKOSUN HP 2340 / 1240

Instruction manual. Water treatment Boiler system D 30 L

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

Metal Cassette Ceiling with BEKA Heating and Cooling Mats

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Domestic Hot Water Tank

Installation and maintenance manual

Lifting Station Type ABS Sanimax

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

ThermoDual Domestic hot water charging system

Operating Instructions!

Operating Instructions

LATENTO Solar system. All-year solar systems Plastic storage tanks Vacuum tube collectors Solar - regulation Accessories

Installation and Operating Manual

Avensys Avensys FIN EST SLO RUS UAE

Thermostatic valves with radiator connection systems

DOMESTIC HOT WATER TANK

cod rev. 4 08/ Kombisolar 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation, operating and servicing instructions

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS, for the User and the Installer. SMART Line. Smart ME A Y2000 B

INSTALLATION GUIDE. soft duomatik evoline

ACCUMULATION OF EUROPEAN CLASS

*24168* Art. Nr.: P20-EN Subject to technical changes. SolvisStrato Installation. Stratified buffer tank

3-way switching valve

ENAMELED INDIRECT WATER HEATERS

REMKO HYBRID HEAT PUMPS

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Glass and Dishwashers AMX / AUX Series

REMKO Comfort-WP The versatile heat pump

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

Your Health, our Technology AWD655. Instrument Washer Disinfector

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

UFM-T100H US ES CA Power Alarm Test TM

WATER HEATERS EN - flyer 03/z/2018 Made in Poland

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Avensys Avensys FIN EST SLO RUS UAE

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

Transcription:

We develop for your future! PRODUCT INFORMATION Hygienic stratification storage tank Universal heat center for legionella safe preparation of DHW Technical description Solarbayer GmbH (18.12) Solarbayer GmbH 1

Content Safety regulations........................................................................... 3 Brief description............................................................................ 4 Description of connections................................................................... 5 Technical specifications...................................................................... 6 Technical facts, dimensions................................................................... 7 Installation/general information............................................................... 8 Connection example....................................................................... 10 Insulation................................................................................ 11 Installation of the insulation................................................................. 12 Trouble shooting.......................................................................... 14 Pictures and drawings in this product information are for information use only and do not replace professional planning. We assume no liability for completeness and accuracy because of technical changes, typing and printing errors. 2 Solarbayer GmbH Solarbayer GmbH (18.12)

Safety regulation Please read the manual carefully to prevent damages due to improper installation. The installation has to be carried out by a specialized company in accordance with the generally accepted codes of practice as well as with the valid regulations and norms. Country specific regulations have to be regarded. Non professional installation as well as other than the intended use will lead to the expiration of warranty. The following engineering rules have to be particularly regarded: DIN 1988 Codes of practice for drinking water systems DIN 4751 Safety requirements for heating installations DIN 4753 Water heaters and water heating installations for drinking water and service water; requirements, marking, equipment and testing DIN 4807 Expansion vessels DIN EN 12828 Heating systems in buildings Design for water based heating systems DIN 18380 Systems for heating and central water heating DIN 18381 Gas, water and sewage plumbing works inside of buildings VDI 2035 Prevention of damage in water heating installations DIN 18382 Electric Cable and Wiring Systems Inside Buildings VDE 0100 Erection of power installations VDE 0105 Operation of electrical installations VDE 0190 Potential equalizing of electrical installations *Before the installation it has to be tested if the DHW installation, especially the connection to the public water supply, is carried out in accordance with DIN 1988 and if the, stated in part 8, prescribed maintenance had taken place. The operability of security relevant units (e.g. pressure regulator) has to be checked in any case. Solarbayer GmbH (18.12) Solarbayer GmbH 3

Brief description A buffer tank as universal heat center with integrated stainless steel corrugated tube for legionellasafe preparation of DHW, with well dimensioned heat exchangers made of circular tube, improved heat layering of the heating return line in the stratification pipe. Perfectly suitable for single and two family houses. connections arranged in 90 angle, possible installation in the corner various connection possibilities perfect heat stratification due to the stratification pipe flexible foam insulation WLG 0,039, insulation thickness approx. 100 mm, silver PVC jacket, fire protection classification B2 high quality steel S235JR large solar heat exchange legionella safe DHW preparation stainless steel corrugated hose 1.4404 with DVGW authorization high hot water output installation of an electric heating element possible Corrosion protection The stainless steel DHW exchanger (stainless steel corrugated tube) can be used with all DHW conditions and in every network. The corrosion protection is given by the stainless steel design. The internal wall of the heating water tank is not corrosion protected since it is set for the application in closed heating systems as a buffer tank. The application of the tank in pressureless heating circuits with Der Einsatz des Speichers in drucklosen Heizkreisen mit nachlaufendem Frischwasser ist nur zulässig, wenn Pufferspeicher und Holzkessel mittels Systemtrennung vom drucklosen/offenen Teil der Heizungsanlage getrennt ist. 4 Solarbayer GmbH Solarbayer GmbH (18.12)

Description of connections Attention: The heating system has to be filled in accordance with VDI 2035. de airing boiler flow line boiler flow line sensor/thermometer sensor/thermometer heating flow line immersion heater Rücklauf Öl /Gaskessel not occupied sensor solar bottom return line wood log boiler return line heating solar flow line hot hot water solar heat exchanger top sensor solar top solar return line heat exchanger top sensor solar flow line heat exchanger bottom sensor Solarrücklauf Tauscher unten cold water solar return line cold Solarbayer GmbH (18.12) Solarbayer GmbH 5

Technical specifications Hygienic stratification storage tank HSK ÖKO 700 1000 capacity approx. L 674 913 height with insulation [A] mm 1690 2090 height without insulation [B] mm 1610 2010 tilted height mm 1795 2040 diameter with insulation [C] mm 990 990 diameter without insulation [D] mm 790 790 flexible foam insulation (PVC jacket) mm 100 100 weight approx. (without / with heat exchanger) kg 185 240 max. operating temperature heating water bar 6 6 max. operating pressure heating water C 95 95 internal tratification system mm Ø 185 Ø 185 max. size of electric heating element (optional) kw 6 6 Specification stainless steel DHW heat exchanger 700 1000 capacity DHW heat exchanger approx. L 39 39 heating surface DHW heat exchanger approx. m² 5,64 5,64 continuous output 10/45 at 17 kw and temperature buffer 65 C L/h 426 426 continuous output 10/45 at 27 kw and temperature buffer 65 C L/h 670 670 continuous output 10/45 at 50 kw and temperature buffer 65 C L/h 1200 1200 stainless steel DHW heat exchanger mm Ø 32 Ø 32 max. operating pressure DHW heat exchanger bar 6 6 max. operating temperature DHW heat exchanger C 95 95 Specification solar heat exchanger 700 1000 heating surface solar heat exchanger top m² 1,6 2,0 capacity solar heat exchanger top L 6,8 8,0 heating surface solar heat exchanger bottom m² 2,5 2,8 capacity solar heat exchanger bottom L 14,1 15,1 max. operating pressure solar heat exchanger bar 10 10 max. operating temperature solar heat exchanger C 110 110 recommended min. collector surface m² 14 17 Thermotechnical facts 700 1000 rate of heat loss in stagnancy according to DIN EN 12976 or DIN ENV 12977 3 W/K 2,02 2,22 rate of standby loss ΔT 45 C according DIN 4753 8 kwh/d 2,18 2,39 6 Solarbayer GmbH Solarbayer GmbH (18.12)

Technical facts, dimensions Connections with dimensioning 700 1000 1 de airing 1 IG [1] oben oben hot water 1 IG [2] mm 1370 1760 flow line solar exchanger top 1 IG [3] mm 1270 1610 sensor/thermometer ½ IG [4] mm 1220 1550 sensor solar top ½ IG [5] mm 1150 1400 sensor/thermometer ½ IG [6] mm 1060 1300 return line solar top 1 IG [7] mm 970 1230 electric heating element 1½ IG [8] mm 900 1100 sensor ½ IG [9] mm 730 1040 flow line solar exchanger bottom 1 IG [10] mm 830 940 sensor ½ IG [11] mm 550 640 sensor solar bottom ½ IG [12] mm 480 480 A B 21 20 19 18 17 16 15 2 3 4 5 6 7 8 9 10 11 12 13 14 return line solar exchanger bottom 1 IG [13] mm 370 380 cold water 1 IG [14] mm 270 280 return line heating 1 IG [15] mm 170 170 return line wood log boiler 1 IG [16] mm 360 360 not occupied 1 IG [17] mm 560 560 return line oil/gas boiler 1 IG [18] mm 810 870 C D flow line heating 1 IG [19] mm 980 1190 flow line boiler 1 IG [20 mm 1120 1410 flow line boiler 1 IG [21] mm 1290 1650 Solarbayer GmbH (18.12) Solarbayer GmbH 7

Installation / general information Location The tank hast to be located in a frost protected place. Ice formation inside the system may lead to the tank s destruction. The location has to have the necessary space for maintenance and repair work, as well as sufficient load bearing capacity of the ground! Site clearance for dismounting the tank and for transport has to be ensured permanently. Insulation The insulation has to be mounted before piping begin. Do not get near the insulation with fire, brazing flame, welding torch, etc.; fire hazard! Piping The tank is to be installed in accordance with the piping diagram [chapter: Description of connections]. This diagram is only a mounting proposal and does not replace professional planning. The connection has to be carried out in accordance with DIN.. The minimum diameter of the safety valve has to be DN20 (¾"). Attention has to be paid to possible electro chemical reactions when choosing the installation material (mixed installation)! Galvanzied pipe installations have to be replaced. With DHW temperatures of more than 60 C it is generally recommended to limit the temperature by a mixing valve to 60 C! The connection components have to be aligned to these temperatures or the temperature has to be limited by means of a mixing valve! Operating pressure The permissible operating pressures according to our technical specifications [chapter: technical specifications] have to be observed. Exceeding the permissible operating pressure may lead to leakages and destruction of the tank! Pressure reducing valve The installation of a pressure reducing valve is recommended. If the DHW supply is operated with higher pressure a pressure reducing valve has to be installed. In order to reduce sounds caused by fluxion inside the building the pipeline pressure should be adjusted to approx. 3,5 bar. DHW filter It is highly recommended to install a DHW filter in the cold water pipeline since floating particles may block fittings, etc. and may cause corrosion in the pipes. 8 Solarbayer GmbH Solarbayer GmbH (18.12)

Safety devices The tank has to be equipped with a non lockable safety valve. Moreover, an expansion vessel has to be installed that is dimensioned according to the tank s capacity. It is to be locked only with a cap valve. An expansion vessel for sanitary water has to be installed for the stainless steel heat exchanger. A safety temperature limiter has to be installed in accordance with heating system regulations for scalding protection means. Next to the exhaust line of the safety valve, or even better, on the valve itself, an indication plate has to be installed, saying: : "Water is leaking from the valve s pipe for safety reasons during the heating. Do not close!" Draining/de airing The tank hast to be installed in such a way that it can be drained without demounting it. While draining, hot water might exit and cause injuries. The upper socket is provided for de airing the tank. We do not recommend the use of an automatic bleeder. Immersion heater (optional) The tank can additionally be equipped with an electric heating element. You have to respect the regulations of your local public utility when installing an immersion heater. The electric heating elements have to be insulated. It is only with insulation that the corrosion protection is guaranteed. Electric heating elements with insulation and integrated temperature control and safety temperature limiter are optional available at Solarbayer. If electric heating elements without insulation are used, the tank s warranty expires.. Initial operation Connections that are not used have to be sealed professionally with plugs. Thoroughly rinse pipes and tank after mounting, heating system has to filled with treated water according to VDI 2035 and bleeded. Not for installers : Record the pressure test and the proper filling of the heating system with water in accordance with VDI 2035 and let it countersign by your customer. Solarbayer GmbH (18.12) Solarbayer GmbH 9

Connection example This connection diagram is only an installation proposal and does not replace technical planning! 10 Solarbayer GmbH Solarbayer GmbH (18.12)

Insulation flexible foam insulation jacket with zipper jacket color 100 mm PVC foil 0,8 mm + 5 mm flexibel foam silver foam density kg/m³ 14,1 (+/ 5% ) compressive resistance 40% KPo 2,1 (+/ 5% ) initial heat conductivity W/mK 0,039 (+/ 5% ) loss of density % 5 Max rebound elasticity % 45 (+/ 5% ) porosity N Celle cml 17 (+/ 5% ) fire protection classification B2 Attention! Only install the insulation with a room temperature of at least 22 C! Pre heat the insulation several hours in a heated room and mount it when still heated! The flexible foam and the PVC jacket are too hard and too short when the insulation is cold! Never use a tong or other tools in order to close the insulation! Solarbayer GmbH (18.12) Solarbayer GmbH 11

Installation of the insulation 1 2 3 Delivery condition Store single components in a warm room Lift the tank of the pallet 4 5 Only mount insulation when pre heated! Pre heat it for 24 hours to at least of 22 C. Adjust sockets to insulation 6 Watch out when closing the zipper (danger of tearing the insulation when cold) Do not use a tong or other tools. 12 Solarbayer GmbH Solarbayer GmbH (18.12)

7 Put on the insulation cap and its cover 8 Feel for the sockets We disclaim any liability for damages due to inappropriate installation. 9 10 Carefully cut out holes Attach covering rosette Inappropriate insulation of the tank s bottom is not allowed. Tank sockets are available for the common tank sizes up to 1000 liter. You can increase the energetic efficiency with a perfect bottom insulation. Especially when renovating old buildings an additional bottom insulation is recommended. Our tank socket is an easy to realize alternative for this since it has excellent insulation characteristics. Our tank sockets are made of galvanized steel and the rear side is insulated with rigid foam. 75 mm available in 2 sizes: Ø 850 mm and 1000 mm Solarbayer GmbH (18.12) Solarbayer GmbH 13

Trouble shooting problem possible reason solution leakage leaky pipe connection air in the system seal the connections tighten pipe connections bleed the system heating up period too long heating water temperature set too low with control unit scaled heat exchanger surfaces increase temperature setting at the control unit run system with water treated in accordance with VDI 2035 no/too small loading and unloading of the tank when heating is required (in the heating water circuit) unwanted tank cooling heating controller not set correctly tank temperature too low changeover valve defect or installed incorrectly flow rate is too low in the heating circuit gravity circulation in the solar/heating/circulation circuit piping insulation not sufficient set controller check heat sources (e.g. performance data) check function bleed heating circuits increase pump performance check pipe dimensions, if necessary adjust them check/install check valve with gravity break insulate piping/tank connections tank insulation not sufficient mount Solarbayer tank insulation safety temperature limiter set too low increase temperature at the safety temperature limiter (thermostatic DHW mixing valve) DHW temperature too low heating water temperature too low supplementary heating starts too late place tank sensor correctly increase tank temperature at the control unit check parameter of the heating controller (turn on temperature difference) 14 Solarbayer GmbH Solarbayer GmbH (18.12)

Notes Solarbayer GmbH (18.12) Solarbayer GmbH 15

We develop for your future Storage systems Fresh water systems Wood log boiler Solar systems Solarbayer GmbH Preith, Am Dörrenhof 22 85131 Pollenfeld Telefon +49(0)8421/93598 0 Telefax +49(0)8421/93598 29 info@solarbayer.de www.solarbayer.de This manual and the pictures and drawings within are protected by the copyright of SOLARBAYER GmbH Technical changes and errors reserved. Valid is the most recent version of this handbool which can always be found on our homepage www.solarbayer.de 16 Solarbayer GmbH Solarbayer GmbH (18.12)