Installation Manual. SB Domestic Refrigerated Container (DRC) Unit Single Temperature System. TK IM (Rev.

Similar documents
SB Domestic Refrigerated Container (DRC) Unit Single Temperature System TK IM (Rev. 2, 02/13)

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

Installation Manual. Truck Edition V-520 RT Series Model 10, 20, 30 and 50 Single Temperature Systems. TK IM (Rev.

Truck Edition V-520 RT Series Models 10, 20, 30 and 50 Single Temperature Systems TK IM (Rev. 8, 1/16)

Trailer Edition Precedent S-600M, C-600M and S-600DE with S-2 and S-3 Remote Evaporator Systems TK IM (Rev. 4, 12/15)

Installation Manual. Truck Edition V-500 Series. TK IM (Rev. 3, 01/05) Copyright 2004 Thermo King Corp., Minneapolis, MN, U.S.A.

Installation Manual. Truck Edition SPECTRUM Multi-Temperature Systems T-800R, T-1000R and T-1200R (ESA ONLY) T-1000 (TSA)

Installation Manual. TriPac. Auxiliary Heating and Cooling Temperature Management System. TK IM (Rev. 13, 01/12)

Truck Edition V-520 Series Single Temperature and SPECTRUM Multi-Temperature Systems TK IM (Rev. 11, 03/18)

Truck Edition V-520 Series Single Temperature and SPECTRUM Multi-Temperature Systems TK IM (Rev. 4, 01/12)

Installation Manual. NAD Truck Edition V-200 and V-300 Series. TK IM (Rev. 7, 02/12)

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

Installation Manual. Truck Edition UT-1280 Undermount Systems. TK IM (Rev 0, 01/17)

Installation Manual. Truck Edition SPECTRUM TM TS Multi-Temperature Systems. TK IM (Rev. 11, 05/15)

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

BlueHeat AirTop 2000 Heater

User Manual Box Exhaust Fan Series (Belt Drive)

Heavy Duty Heater / Air Conditioner Model R-8545

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Installation Instructions

Sleeper Heater and Air Conditioner, Blend Air System 83.05

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Installation. Built-in Full Height Wine Cellar VCWB301

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Viking Installation Guide

1. General Description

Installation Instructions

HEATING AND AIR CONDITIONING

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

SAFETY AND INSTALLATION MANUAL MODEL 8100

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

an ISO 9001:2015 Registered Company

HEATING AND AIR CONDITIONING

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

UMA-1020 Light Weight Suspended Ceiling Kit

Installation Instructions

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

Disposal Manual. m{zd{ 6. Capacitor( -ELOOP ) October 2012 Mazda Motor Corporation

Installation Instructions Part No , Part No Part No

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Page 1 of 18. Part# /5/2013

Installation Instructions

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation Instructions

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE YCC-IG EB23D1-12

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

SB-210+ MAGNUM to be placed

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

RK-02 Multi Point Detector Operator s Manual

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Panel Fan Series Operators Manual (Galvanized and Polymer)

e Bath Fan with Light User s Guide

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

e Bath Fan with Light User s Guide

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

CF35 # INSTALLATION & OPERATION

Installation Instructions

Installation. Leveling

Installation Instructions

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

BC BRONCOS AIR CONDITIONING UNIT

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

R100 Oil-Less Refrigerant Recovery Unit

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Safety Message to Installers of Federal Signal Siren Speakers

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION INSTRUCTIONS

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

e Bath Fan with Light User s Guide

Ductless Split Air Conditioner

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

CMA-440 Light Weight Suspended Ceiling Kit

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Viking Installation Guide

Models , Equinox, and Sirens Clutch Replacement Service Manual

Installation Instructions

Be sure the siren amplifier and speaker(s) in your installation have compatible wattage ratings.

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Transcription:

Installation Manual SB-210+ 30 Domestic Refrigerated Container (DRC) Unit Single Temperature System TK 54654-5-IM (Rev. 0, 12/10) Copyright 2010 Thermo King Corp., Minneapolis, MN, U.S.A. Printed in U.S.A.

Release History Released (12/10) 2

Domestic Refrigerated Container (DRC) 3

Introduction This manual was written to assist with the installation of the Thermo King SB-210+ 30 Single Temperature refrigeration systems onto a Domestic Refrigerated Container (DRC) that is specifically designed and built for refrigerated applications. Due to its complexity, you should not attempt this installation unless you: Are an experienced mechanic Can safely lift 34 kilos (75 lbs.) Are certified or trained in the repair and maintenance of diesel powered refrigeration systems Have a basic understanding of electricity and electrical wiring Have the necessary tools and equipment to complete the installation. This manual is published for informational purposes only. Thermo King makes no representations warranties express or implied, with respect to the information recommendations and descriptions contained herein. Information provided should not be regarded as all-inclusive or covering all contingencies. If further information is required, Thermo King Corporation Service Department should be consulted. Thermo King s warranty shall not apply to any equipment which has been so installed, maintained, repaired or altered as, in the manufacturer s judgment, to affect its integrity. Manufacturer shall have no liability to any person or entity for any personal injury, property damage or any other direct, indirect, special, or consequential damages whatsoever, arising out of the use of this manual or any information, recommendations or descriptions contained herein. 4

Table of Contents Safety Precautions........................................... 6 Domestic Refrigerated Container (DRC) Requirements.............. 8 SB-210+ 30 Unit Dimensions.................................. 9 Evaporator Opening Requirements............................. 10 Mounting Hardware Requirements............................. 12 Bulkhead Dimensions (Option)................................ 14 Lifting Bar Dimensions...................................... 16 Required Tools............................................. 18 Installation Components..................................... 20 Unpacking the Unit......................................... 22 Installing the Unit.......................................... 24 Installing the Exhaust Extension............................... 26 Installing the Drain Hoses.................................... 28 Installing the Bulkhead (Option)............................... 30 Installing the Fuel Tank...................................... 32 Installing the Fuel Lines..................................... 34 Installing the Fuel Level Sensor Harness (Option)................. 36 Installing the Battery........................................ 38 SR-2 Programming Procedures................................ 40 SYSTEM CHECK LIST...................................... 41 5

Safety Precautions The symbol appears next to a point that is particularly important: DANGER: Addresses a circumstance that, if encountered, will lead to death or serious injury WARNING: Addresses a circumstance that, if encountered, might lead to death or serious injury. CAUTION: Addresses a circumstance that, if encountered, may cause damage to equipment or minor injury. DANGER: Never operate the unit with the discharge valve closed because it could cause the compressor to explode, causing death or serious injury. DANGER: Never apply heat to a sealed refrigeration system or container because it could explode, causing death or serious injury DANGER: Fluorocarbon refrigerants, in the presence of an open flame or electrical short, produce toxic gases that are severe respiratory irritants capable of causing death. DANGER: Be careful when working with a refrigerant or refrigeration system in any enclosed or confined area with a limited air supply (i.e., a trailer, container or the hold of a ship). Refrigerant tends to displace air and can cause oxygen depletion which may result in death by suffocation. WARNING: Always wear goggles or safety glasses. Refrigerant liquid, refrigeration oil, and battery acid can permanently damage the eyes (see First Aid under Refrigeration Oil). WARNING: Keep your hands away from fans and belts when the unit is running. This should also be considered when opening and closing the compressor service valves. WARNING: Make sure gauge manifold hoses are in good condition. Never let them come in contact with a belt, fan motor pulley, or any hot surface. WARNING: Make sure all mounting bolts are tight and are of correct length for their particular application WARNING: Never drill holes in the unit unless absolutely necessary. Holes drilled into the unit may weaken structural components. Holes drilled into electrical wiring can cause fire or explosion. WARNING: When using ladders to install or service refrigeration systems, always observe the ladder manufacturer s safety labels and warnings. A work platform is the recommended method for installations. WARNING: Exposed coil fins are very sharp and can cause painful lacerations. 6

Safety Precautions (continued) Refrigerant First Aid WARNING: Although fluorocarbon refrigerants are classified as safe refrigerants, certain precautions must be observed when handling them or servicing a unit in which they are used. When released to the atmosphere in the liquid state, fluorocarbon refrigerants evaporate rapidly, freezing anything they contact. FROST BITE: In the event of frost bite, the objectives of First Aid are to protect the frozen area from further injury, to warm the affected area rapidly and to maintain respiration. EYES: For contact with liquid, immediately flush eyes with large amounts of water and get prompt medical attention. SKIN: Flush area with large amounts of lukewarm water. Do not apply heat. Remove contaminated clothing and shoes. Wrap burns with dry, sterile, bulky dressing to protect from infection/injury. Get medical attention. Wash contaminated clothing before reuse. INHALATION: Move victim to fresh air and use CPR or mouth-to-mouth ventilation, if necessary. Stay with victim until arrival of emergency medical personnel. Refrigeration Oil First Aid WARNING: Avoid refrigeration oil contact with the eyes. Avoid prolonged or repeated contact of refrigeration oil with skin or clothing. Wash thoroughly after handling refrigeration oil to prevent irritation. NOTE: In case of eye contact, immediately flush with plenty of water for at least 15 minutes. CALL A PHYSICIAN. Wash skin with soap and water. 7

Domestic Refrigerated Container (DRC) Requirements Approximate Weight of SB-210+ 30 (refrigeration unit only) = 742 kg (1635 lbs.) Front Wall Requirements DANGER: The front wall of the container must be structurally strong enough to support the combined weight of the Thermo King refrigeration unit, the fuel tank with mounting hardware, and the full capacity of diesel fuel! Evaporator Opening Requirements IMPORTANT: The location of the evaporator opening in the front wall of the container is critical to the proper installation and operation of the Thermo King unit. See Evaporator Opening Requirements on pages 10-11. Fuel Tank Mounting DANGER: An improperly installed fuel tank could lead to serious injury or death! Consult your container, trailer or rail car manufacturer for specific details on proper fuel tank installation and recommendations. Unit Dimensions Adequate clearance must be provided to allow for routine service and maintenance of the Thermo King unit. See SB-210+ 30 Unit Dimensions on page 9. Unit Mounting Hardware DANGER: The use of mounting hardware other than specified for installing the refrigeration unit could result in severe damage to equipment, void the warranty or cause personal injury or death! IMPORTANT: The location of the unit mounting bolts in the front wall of the container is critical for proper unit installation. See Mounting Hardware Requirements on pages 12-13. 8

SB-210+ 30 Unit Dimensions 9

Evaporator Opening Requirements Evaporator Opening Requirements IMPORTANT: The location of the evaporator opening in the front wall of the container is critical for the proper installation and operation of the Thermo King unit. VERIFY ALL DIMENSIONS BEFORE INSTALLING UNIT! 1. The evaporator opening must be square and the diagonal measurements must be ±3.0 mm (0.12 in.) 2. The gasket surface around the opening must be at least 76.2 mm (3.00 in.) wide, be flat ±3.2 mm (0.05 in.) and free of rivets, seams or bolt heads. 10

Evaporator Opening Requirements 11

Mounting Hardware Requirements Unit Mounting Hardware DANGER: The use of mounting hardware other than specified for installing the refrigeration unit could result in severe damage to equipment, void the warranty or cause personal injury or death! IMPORTANT: The location of the unit mounting bolts in the front wall of the container is critical for proper unit installation. All UNIT mounting hardware must be: Mounting bolts must be square with the front wall and securely fastened to the container to allow the mounting nuts be torqued to 82 N m (60 ft. lbs.) from outside the container. Mounting bolts must be 1/2-13 UNC- 28 rolled thread, grade 5, medium carbon steel, zinc plated with dichromate finish. Mounting bolts must extend a minimum 57.2 mm (2.25 in.) beyond the front wall. Matching locking nuts and flat washers (supplied) must be used to secure the unit. 12

Mounting Hardware Requirements 13

Bulkhead Dimensions (Option) THERMO KING RECOMMENDS USING A BULKHEAD Bulkheads are available from authorized Thermo King Dealers Return Airflow Restrictions of the return airflow adversely affects the performance of the unit. The area directly behind the evaporator return air inlet must not be restricted. Bulkhead Function A bulkhead is used to keep the return airflow from being restricted if the load shifts. The bulkhead also prevents the load from shifting into the return airflow passageway on the front wall of the inter modal container. 14

Bulkhead Dimensions (Option) 15

Lifting Bar Dimensions DANGER: Do not use a forklift to install the unit! This could result in severe damage to the equipment, void the warranty or cause personal injury or death! WARNING: Thermo King requires a 3 point lifting bar to safely lift and install units. A lifting bar can be made from the drawings provided (see Lifting Bar Dimensions). WARNING: All hardware used to assemble the lifting bar must be DIN 931 class 10.9 (SAE grade 8). The use of hardware other than specified may cause personal injury, severe damage to the evaporator and void the warranty. WARNING: The lifting bar and lifting device combined must be able to support minimum weight of 1360.8 kilos (1 1/2 tons). I. Recommended material: 76.2 mm (3.00 in.) x 12.7 mm (0.50 in.) mild steel. II. Use forged chain links and hooks, clevis and pins with strength equal to total lift capacity of hoist mechanism and meet all safety standards. III. Bolt together for maximum strength and safety. 1. Forged Clevis Pin 2. Forged Chain Links 3. Locking Master Chain Link 16

Lifting Bar Dimensions 17

1. Safety Glasses 2. Drill 3. Drill Bits 4. Tape Measure 5. Mechanics Tools 6. Lifting Bar 7. Work Platform (Recommended) 8. Torque Wrench 9. Forged Eyebolts NOTE: Equipment such as scales, gauges, refrigerant leak detectors, and torque wrenches should be in good working condition and routinely calibrated to assure accurate readings. Required Tools 18

Required Tools 19

Installation Components Unit Installation Components 1. Locking nuts 1/2-13 2. Washers 1/2 in. 3. Self tapping screws 4. Clamps 5. Cable ties 6. Fuel line fittings: 1/4 in. and 3/8 in. 7. Drain hose check valve 8. Exhaust pipe extension, hanger and clamps 20

Installation Components 21

Unpacking the Unit DANGER: Do not use a forklift to install the unit! This could result in severe damage to the equipment, void the warranty or cause personal injury or death! WARNING: Thermo King requires a 3 point lifting bar to safely lift and install units. A lifting bar can be made from the drawings provided (see Lifting Bar Dimensions). Units are shipped attached to disposable wooden pallet and wrapped with protective cardboard and plastic stretch wrap. To avoid unnecessary damage to your unit, place the crated unit near the container prior to its removal. DO NOT use a sharp knife to remove the stretch wrap or cardboard wrap as damage to the exterior of the unit will result! Unpacking the Unit Carefully remove plastic stretch wrap from unit. Carefully remove the top cardboard cover. Carefully remove the outer cardboard wrap. Remove installation kit boxes, bottom panel, and any other loose components from rear of unit. Remove the tie bands securing the fuel lines to the rear of the unit. Attach forged eyebolts and 3 point lifting bar to unit. Remove hardware holding unit to wooden pallet. Unit is now ready for installation. 22

Unpacking the Unit 23

Installing the Unit WARNING: Do not use a forklift to install the unit! This could result in severe damage to equipment, void the warranty or cause personal injury or death! WARNING: Use only locking hooks to safely lift the unit! Failure to use locking hooks could result in severe damage to the equipment, void the warranty or cause personal injury or death! (Detail I). WARNING: Thermo King requires a 3 point lifting bar to safely lift and install units. A lifting bar can be made from the drawings provided (see Lifting Bar Dimensions). Unit Installation NOTE: Unbolt and remove any upper cross bracing or supports from the container that interfere with the installation of the unit using the 3 point lifting bar. 1. Install two 5/8-11 forged lifting eyebolts (installer supplied) into threaded holes located on the top of the unit (Detail I). 2. Attached the lifting bar to the both eyebolts and the unit support bracket. Lift unit up to the front wall opening: Align the eight mounting studs on the container with the mounting holes in the unit. Push the unit up flush with the front wall of the container. Install the supplied locking nuts and flat washers onto each mounting stud and tighten mounting hardware securely. See Access to Mounting Holes (Detail II). NOTE: All nuts that hold the unit to the container should be elastic stop nuts (Nylock Type) provided in the installation kit. Access to Mounting Holes (Detail II) 3. Top side mounting hole through the hinged roadside grille. 4. Center side mounting hole through hinged roadside grille. 5. Lower side mounting hole through hinged roadside panel and control box hole. 6. Center side mounting hole through hinged lower curbside door. 7. Lower side mounting hole through hinged curbside panel. 8. Center side mounting hole through hinged curbside grille. 9. Top side mounting hole through hinged curbside grille. 10. Top center mounting hole from top of the unit. NOTE: After the unit has been secured, reinstall any upper cross bracing and supports that may have been removed from the container earlier. 24

Installing the Unit 25

Installing the Exhaust Extension Installation 1. Install the exhaust hanger onto the stud located on the container. 2. Install the extension pipe onto the end of the exhaust pipe of the unit. 3. Install exhaust clamps as shown and tighten securely. 26

Installing the Exhaust Extension 2 1 3 3 27

Installing the Drain Hoses Installation DRC applications typically have the fuel tank mounted directly under the refrigeration unit which interferes with the drain hoses. The drain hoses will need to be routed off to one side and down the container wall. 1. Route both drain hoses off to one side of the container. 2. Secure with screws and clamps provided in installation kit. IMPORTANT: Drain hoses should run down from the unit with no kinks or sharp bends. 3. Cut off excess hose and attach the drain hose check valves provided in the installation kit onto the ends of each hose with cable ties. 28

Installing the Drain Hoses 29

Installing the Bulkhead (Option) THERMO KING RECOMMENDS USING A BULKHEAD Bulkheads are available from authorized Thermo King dealers. CAUTION: Do not drill holes into refrigeration, electrical or mechanical components or severe damage to the equipment will result! Return Airflow Restrictions of the return airflow adversely affects the performance of the unit. The area directly behind the evaporator return air inlet must not be restricted. Bulkhead Function A bulkhead is used to keep the return airflow from being restricted if the load shifts. The bulkhead also prevents the load from shifting into the return airflow passageway on the front wall of the container. Typical Bulkhead Shown Follow bulkhead manufacturer specific details for proper installation and recommendations. 30

Installing the Bulkhead (Option) 31

Installing the Fuel Tank Consult your container manufacturer for specific details on proper fuel tank installation and recommendations. 32

Installing the Fuel Tank BLANK PAGE 33

Installing the Fuel Lines Fuel Line Installation DANGER: Leaking fuel lines could cause a fire resulting in death or serious injury! All fuel line fittings must be tight and leak free! DANGER: Do not route fuel lines with battery cables or electrical wires, as this could cause a fire! 1. Uncoil the fuel supply and return lines from the rear of the unit. IMPORTANT: The fuel lines must remain routed through the provided insulated clamp as shown, then down to the fuel tank. 2. Route the 3/8 FUEL SUPPLY line to the fuel tank fitting: The supply line when installed into the tank must be no higher than 25.4 mm (1.00 in.) from the bottom of the tank. Determine this length and cut the supply line. Cut the end of the supply line at a 45 degree angle and slide on the fuel line fittings. Insert the supply line into the fuel pickup fitting until it is 25.4 mm (1.00 in.) from the bottom of the tank then tighten the fuel line fitting securely. 3. Route the 1/4 FUEL RETURN line to the fuel tank: Cut the return line to the appropriate length and slide on the fuel line fittings. Install the line onto the fuel return fitting and then tighten the fuel line fitting securely. 4. Remove the plastic cap from the fuel vent and point the outlet to the rear of the container. NOTE: Add a sufficient amount of fuel (1/4 tank) to allow the unit to run for 8 to 12 hours during engine break-in and pre-delivery procedures. 34

Installing the Fuel Lines 2 3 IMPORTANT: The fuel lines must remain routed through the provided insulated clamp as shown, then down to the fuel tank. 35

Installing the Fuel Level Sensor Harness (Option) Wire Routing and Connections DANGER: Do not route electrical wires with fuel lines as this could cause a fire! 1. Locate the short factory installed fuel level sensor harness with the 3-pin connector. This connector is located outside the control box and cable tied to other harnesses at the rear of the unit near the frame mounted ground plate. Apply a light coating of Superlube or equivalent to this connector. Connect the 6 ft. (1.8 m) fuel level sensor harness to the mating 3-pin connector on the factory installed harness. Route the harness to the fuel tank. IMPORTANT: The use of the supplied crimp and solder style connectors with separate heat shrink tubing is required when connecting the fuel level sensor harness wires. 2. At the tank, connect the harness wires to the fuel level sensor wires (wires are not polarity sensitive) by: Sliding supplied heat shrink tubing onto each wire and positioning them away from the joint. Striping the wire ends, inserting them into the wire connectors and crimping securely. Soldering the wires to the wire connectors with a soldering gun. Sliding the heat shrink tubing over the wire connectors and applying heat with a heat gun. 3. Use supplied cable ties, clamps and screws to secure the harness as shown. IMPORTANT: See SR-2 Programming Procedures on page 40 to enable the fuel level feature. 36

Installing the Fuel Level Sensor Harness (Option) 37

Installing the Battery CAUTION: Set all electrical controls to the OFF position before connecting the battery to prevent the unit from starting! CAUTION: Always wear protective clothing, gloves and eye wear when handling and installing batteries! CAUTION: Cover battery terminals to prevent accidental shorting during battery installation! NOTE: Thermo King units are designed for one 12 volt, group 31 battery. The battery must be suitable for deep cycling, heavy duty and rated with a minimum of 95 amp/hr. 1. Install the battery into the tray. 2. Install the battery hold down bracket and rods. Loosely install hardware onto the rods. NOTE: One of the hold down rods must fit into the notch located on the channel under the battery. You may have to move the electrical harness slightly to access this notch. 3. Align the tab of the battery hold down bracket over the two existing holes in the frame support channel. 4. Install the two mounting bolts and flat washers through the hold down bracket and support channel. Torque hardware to 13.5 N m (120 in-lbs). 5. Tighten the two battery hold down rods to 2.25 N m (20 in -lbs.) DO NOT over tighten as this may crack or distort the battery! 6. Install positive + battery cable on the positive battery post first to minimize accidental electrical shorting. Tighten the bolt securely. 7. Install negative - battery cable on negative battery post second to minimize accidental electrical shorting. Tighten the bolt securely. 38

Installing the Battery 39

SR-2 Programming Procedures Fuel Level 1. Enter the Guarded Access Menu. 2. Scroll down and select: Unit Configuration 3. Scroll down and select: Fuel Level Sensor. The choices are: NONE, SOLID STATE and FLOAT. Scroll to FLOAT by pressing the + key then the YES key. Fuel Level Percent will now be in the gauge menu. Press the exit key. The unit is now programmed to indicate fuel level. Remote Satellite Device (if applicable) 1. Enter the Guarded Access Menu. 2. Scroll down and select: Programable Features 3. Scroll down and select: Remote Device The choices are: Enable/Disable. Scroll to Enable then press the + key then the YES key Press the exit key. The unit is now programmed to accept remote satellite communications. 40

SYSTEM CHECK LIST All unit mounting hardware torqued to specifications. No air gaps between unit and container wall. Drain hoses properly routed, secured with drain valves installed. Fuel tank and mounting straps installed per tank manufacturers specifications Fuel lines properly routed and fuel fittings tightened securely. Bulkhead (recommended) installed. Battery secured and all connections clean and tight. Doors closed and secured. Run Pre-Trip test (refer to Host Unit Operating Manual). Unit operated under load for eight hours to properly break-in engine. Release to customer. 41