BIX B-One 100 kw INSTALLATION GUIDE

Similar documents
CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

Light oil burners. One stage operation

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

Oil burners Brûleurs fioul Stookoliebranders

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Light oil / kerosene burner

Light oil - kerosene burner

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

MALVA Multiair 10 UP! S1

Parts Available from

Easyfire Standalone biomass pellet boiler

PELLET BURNER PV 350

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Electronic Pellet Burner Controller NPBC-V3M

GUIDE BOOK MAINTENANCE

cod. 3540I818EN Rev /2014 SUN P7 - P12 EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

EasyTech.One Temperature Controller for Pellet Burner

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

Pellet Boilers. Instructions for Use and Maintenance

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

WHE 2.24 / WHE 2.24 FF

Operation and maintenance manual for the. KSP Spark. series boilers equipped with feeders

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Electronic Pellet Burner Controller NPBC-V3-1

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

HOT AIR WOOD STOVE AIRVENT TECHNICAL DOCUMENTATION V. 1.1

Model / Plus Technical data Colour Description Code Price. kw-m 4,7** kw-n 4,0** m 3 114** % >85** Capienza kg 10** kg/h 1** Dim. L-H-P.

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

.it AQ USER OPERATING INSTRUCTIONS

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

1. GENERAL INSTRUCTIONS Carefully read the instructions contained in this instruction booklet and store booklet in a safe place.

Model 60200FR Gas Primary Control Data Sheet

RIELLO 40 GS/M SERIES

NOVELLA EVO - NOVELLA PLUS EVO MADE IN ITALY. design & production Rev 001

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Price List. Wood Products and Thermo Products Pellet Products and Thermo Products RECOMMENDED RETAIL PRICE WITHOUT VAT

DH-Direct Fired Poultry Farm Diesel Heater

Water FOGHET stove INSTALLATION, USE AND MAINTENANCE MANUAL. FOGHET With curved front. FOGHET With straight front. WOOD version

USERS MANUAL FOR GAS BOILERS

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

VETO CLEANER 500 FLUE GAS CLEANER

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

DEVRON SERIES MULTI FUEL FIRED GASIFICATION HOT WATER BOILERS DEVRON-30, DEVRON-40 OPERATION, USE AND MAINTENANCE MANUAL

EasyTech.Full Temperature Controller for Pellet Stove. Idro

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

USER MANUAL 9kW LILLY PELLET STOVE

STILE BEAUTY AND TECHNOLOGY

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

USER'S INFORMATION MANUAL

ENVI Boiler Controller

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Model Universal Oil Primary Control

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

1. The structure and its description

2 OPERATION WITH PELLETS AND SPECIAL KIT... 9

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

.it INSTALLATION AND MAINTENANCE INSTRUCTIONS

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

A.D. METALNA INDUSTRIJA VRANJE Radnička br: 1 PELLET BOILER GRANDE

INSTRUCTIONS FOR ASSEMBLY, USE, AND MAINTENANCE PELLET STOVE LUCA S/LUKA S8

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

INSTRUCTION FOR THE USER THC V E OIL BLU

USE AND MAINTENANCE INSTRUCTIONS PELLET STOVE. Air Channelled Air Hydro Boilers

pellet stoves USER MANUAL lcd

anastasia plus MADE IN ITALY design & production Rev 002

Installation and operation manual for pellet boiler TANGRA HP 30. Manufactured in accordance with standard: - EN Rev.

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

LAGUNA P Installation, use and maintenance

Single stage operation oil burner

ir-range 8G /03.15 Changes reserved.

GAS AND PELLET BURNERS

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

THERMO PRODUCTS USER MANUAL. diadema idro - liliana idro MADE IN ITALY. design & production Rev 008

Eco Angus Wood Pellet Boilers

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Transcription:

BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality. The high consistency and advanced design of our pellet burner makes it adequate for use on most solid fuel boilers present today on the market. www.tradgardsteknik.se 0431-222 90 1

Table of Contents INDEX 1.0 SAFETY 1.1 WARNINGS 2.0 FEATURES & TECHNICAL SPECIFICATIONS 2.1 PACKAGING CONTENTS 2.2 DIMENSIONS 2.3 TABLE OF TECHNICAL SPECIFICATIONS 2.4 EXPLODED VIEW 2.5 PARTS LIST 2.6 WIRING DIAGRAM 3.0 OPERATING INSTRUCTIONS 3.1 CONTROL PANEL AND KEY DESCRIPTION 3.2 USER SETTINGS 3.3 TECHNICAL SETTINGS 3.4 GENERAL SETTINGS 3.5 SETTING CANCELLATION 4.0 INSTALLATION 4.1 OPERATING INSTRUCTIONS 4.2 INSTALLATION INFORMATION 4.3 FUEL SUPPLY 4.4 INSTALLATION ON BOILER 5.0 SERVICE & MAINTENANCE 5.1 WIRING 5.2 START-UP 5.3 MAINTENANCE 5.4 FAULTS - CAUSES - SOLUTIONS 6.0 PRECONFIGURED PARAMETERS 6.1 PRECONFIGURED TECHNICAL PARAMETERS 6.2 PRECONFIGRUED GENERAL PARAMETERS 6.3 TECHNICAL PARAMETER VARIATION TABLE 6.4 GENERAL PARAMETER VARIATION TABLE www.tradgardsteknik.se 0431-222 90 2

1.0 SAFETY 1.1 WARNINGS! CHECK THAT THE FUME EXHAUST PIPE HAS AN ADEQUATE DRAUGHT BEFORE CONNECTING THE BURNER TO THE BOILER! Do not start the burner before it is connected to the boiler and the boiler is connected to the chimney.! We recommend using a mask during the handling of the pellets.! The boiler room where the burner is installed must comply with all legal regulations and recommendations! All wiring must be done by qualified professional! No inflammable material must be stored close to the burner WARNING» It is strictly prohibited to make modifications without written authorization from the manufacturer» Use only original spare parts approved by the manufacturer in order to prevent possible damage to the burner» Do not open any boiler doors until the burner is operating» Welding on the electronic card may be carried out only once the burner has been disconnected from the electricity mains. The circuit must be removed from the burner. www.tradgardsteknik.se 0431-222 90 3

FEATURES AND TECHNICAL SPECIFICATIONS Packaging contents 1. BURNER 2. GRILL (Brazier) 3. BOOT LINK FOR FLEXIBLE TUBE 4. O-RING 5. POWER CABLE 6. WATER PROBE CABLE 7. FLEXIBLE TUBE 8. INSTRUCTION MANUAL www.tradgardsteknik.se 0431-222 90 4

2.2 DIMENSIONS 2.3 TABLE OF TECHNICAL SPECIFICATIONS BURNER DATA 100 Kw UNITS VALUES Burner 100 [Kw] Max. Thermic Capacity Min. Thermic Capacity Max. Combust. Capacity. Min. Combust. Capacity. Supply Voltage/Frequency Absorbed Electric Power Electric Power Igniter Empty Weight Pellet Size (Ø / Max. Length) Non-floury grain kw kw kg/h kg/h V/Hz W W kg mm 100 50 20 7,3 230/50 50 300 21 Recommended www.tradgardsteknik.se 0431-222 90 5

2.4 EXPLODED VIEW www.tradgardsteknik.se 0431-222 90 6

2.5 PARTS LIST POS. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 DESCRIPTION CONTROL PANEL MAIN SWITCH AXIAL FAN THERMOSTATS CENTRIFUGAL FAN FAN SUPPORT TUBE FOR INTERNAL COCLEA SELF CLEANING GUIDE SYSTEM TRANSFORMER INFERIOR GRILL 11 SOCKET FOR LOADING COCHLEA WITH FAN [OPTIONAL] 220 VOLT POWER OUTLET BUTTON FOR MANUAL PELLET LOADING CONNECTIONS CARD SUPPORT PANEL ELECTRONIC CARD RIGHT PANEL INTERNAL PLATE SELF CLEANING BRACKET SYSTEM RESISTANCE (Spark Plug for Pellet Ignition) SMOKE SENSOR SUPPORT BRACKET FOR SMOKE SENSOR SELF CLEANING BRACKET SYSTEMS THREADED RODS RESISTANCE SUPPORT PLATE FOR RESISTANCE SUPPORT and INT. COCHLEA TUBE COMBUSTION GRILL COMBUSTION CHAMBER INTERNAL COCHLEA SUPPORT FOR SELF CLEANING GEARMOTOR PIN FOR SELFCLEANING GEARMOTOR SELFCLEANING GEARMOTOR ESCUTCHEON PIN SELFCLEANING GEARMOTOR ELASTIC RING PIN SELF CLEANING GEARMOTOR THERMOSTAT SUPPORT BRACKET AUTO SYSTEM COGWHEEL INTERNAL COCHLEA TUBE COVER COCHLEA TUBE AND MOTOR SUPPORT 2 CLOSURE MOTOR 2 FOR INTERNAL COCHLEA O-RING FRONTAL CARTER CONNECTING BOOT FOR FLEXIBLE TUBE LEFT PANEL www.tradgardsteknik.se 0431-222 90 7

2.6 WIRING DIAGRAM www.tradgardsteknik.se 0431-222 90 8

3.0 OPERATING INSTRUCTIONS 3.1 CONTROL PANEL AND BUTTON DESCRIPTION BUTTONS 1 ON/OFF Button (Starts and turns off the burner) 2 Display 3 UP button (Increases Power, if used on the Home Screen) 4 DOWN button (Diminishes Power, if used on the Home Screen) 5 SET key» SET+UP = State of cycle (Shows temperature, etc.)» SET for 2 seconds= Configures Time, chronothermostat, language, display contrast.» SET open and release = Water temperature adjustment» ON/OFF+SET+UP+DOWN for 2 Secs,= Activates technical parameters www.tradgardsteknik.se 0431-222 90 9

3.2 USER SETTINGS 1. Open SET key for 2 seconds 2. Select the menu parameters with the arrow keys A. Time settings B. Chronothermostat settings C. Not used D. Language settings E. Display contrast TIME SETTINGS To set the time use the arrow keys, to scroll through the configuration screens press the SET key, to exit setting configuration press ON/OFF CHRONOTHERMOSTAT SETTING To configure the chronothermostat use the arrow keys, to scroll through the configuration screens press the SET key, to exit setting configuration press ON/OFF. FUEL TYPE The burner is calibrated only for the use of Pellets. LANGUAGE Select the language CONTRAST The contrast refers to display visualization 3.3 TECHNICAL PARAMETER SETTING (for the installer)» Press all keys at the same time» Insert access code = (in possession of the installer) and press SET» Select the Technical parameter menus with the arrow keys» To confirm press SET, to exit press ON/OFF www.tradgardsteknik.se 0431-222 90 10

1. Delta Control Temperature (0-9) [necessary for the setting, modulation or when burner is on for water temperature] 2. Delta Temperature Wait (0-30) [necessary for regulating the water temperature] If the room temperature is higher than the user temperature set + Delta, the burner turns off and wait. If Delta = 0, it is deactivated. 3. Ignition Attempts [If the max time of ignition has passed, and the burner is still off, new ignition attempts are carried out before saying that the burner is off] 4. Lamp Time [If during the minutes configured no key is pressed then the display light goes into standby] 5. Vacuometer Control 6. Pellet Thermostat Control 7. Ext. Thermostat Enablement [enables management of the external thermostat, when the external thermostat contact is at 0 the burner goes into modulation, mimum power: ON = Enabled - OFF = Not enabled] 8. Water Temperature [enables viewing and management of the water temperature on the main screen: ON = Enabled - OFF = Not enabled] 3.4 GENERAL SETTINGS (FOR THE INSTALLER)» Press all keys at the same time» Insert access code = (in possession of the installer) and press SET» Select the Technical parameter menus with the arrow keys» To confirm press SET, to exit press ON/OFF 1. Maximum Ignition Time in min. [maximum time within which the burner must turn on] 2. Flame Stabilizing Time [once the flame is on, wait for the stabilizing time of the flame to pass in order to ascertain the burner has started] 3. Time between Cleanings in min. [once the burner is on, this is the time before cleaning of brazier - if 0 = Deactivated] 4. Brazier Cleaning Time in secs. [brazier cleaning time if the time between cleanings ends; if time between cleanings = 0, cleaning has not been done - when the burner is off, the smoke extractor always starts at maximum speed for this time even if the time between cleanings = 0] 5. Alarm Delay in secs. [time of delay before alarm checking] 6. Lux minimum start-up [Lux time in which the Photoresistance must stay above a pre-programmed Lux time, before moving into the Flame stabilization and Stove switched-on phase] 7. Lux Turning Off [if the photoresistance for a particular Lux period remains under a pre-programmed time span in Lux, the burner turn-off function is started up, and in this phase it can give the ALARM signal: Fuel Low or Stove switched off] 8. TIM turning-off [time in minutes of fan functioning inside burner at MAX speed in turning-off phase] www.tradgardsteknik.se 0431-222 90 11

9. Time before Resistance Ignition [minutes of time before resistance ignition before burner start up] 10.Manual Loading Time [time of pellet manual loading] 11.TIM [External Thermostat Shut off time 1-99 minutes] 12. TIM LUX Neutral Zone [LUX time which detects the Photoresistance before turning off burner] 13. Max. Cochlea Time sec. [maximum time of cochlea operating] 14.Time of cochlea loading in secs. [time of cochlea in ON phase of pellet loading to start up the burner, the OFF time is given from the difference between the maximum time and the ON time] 15. Cochlea Starting Time. [time of cochlea in ON starting phase after flame is burning] 16. Cochlea cleaning time in secs. [time of cochlea in ON brazier cleaning phase] 17. Cochlea Time Power 1 [ON time of cochlea to the power of 1 once burner is started] 18. Cochlea Time Power 2 [ON time of cochlea to the power of 2 once burner is started] 19. Cochlea Time Power 3 [ON time of cochlea to the power of 3 once burner is started] 20. Cochea Time Power 4 [[ON time of cochlea to the power of 4 once burner is started] 21. Cochlea Time Power 5 [ON time of cochlea to the power of 5 once burner is started] 22. Vacuum during Loading [extractor speed in loading phase] 23. Vacuum during Operation [extractor speed in start-up phase after lighting flame] 24. Vacuum during Cleaning [extractor speed during cleaning of brazier] 25. Vacuum Power 1 [extractor speed to the power of 1 once burner is started] 26. Vacuum Power 2 [extractor speed to the power of 2 once burner is started] 27. Vacuum Power 3 [extractor speed to the power of 3 once burner is started] 28. Vacuum Power 4 [extractor speed to the power of 4 once burner is started] 29. Vacuum Power 5 [extractor speed to the power of 5 once burner is started] 30. Not Used 31. Not Used 32. Not Used 33. Not Used! Notice= THE TECHNICAL AND GENERAL PARAMETERS ARE CONFIGURED IN THE FACTORY, WE STRONGLY DISCOURAGE ANY HANDLING BY UNTRAINED PEOPLE OR CHILDREN; ONLY SPECIALIZED OR QUALIFIED PERSONNEL SHOULD HANDLE THE BURNER. www.tradgardsteknik.se 0431-222 90 12

3.5 PARAMETER CANCELLATION In order to cancel parameters, turn off and start the burner again selecting the model. The selection of the model happens with the arrow kews. Confirmation comes by pressing the SET button. The selection operates the default parameters also. 4.0 INSTALLATION 4.1 OPERATING INSTRUCTIONS Operation of the burner, once installed and correctly set up, (AS PRECONFIGURED IN THE FACTORY) is completely automatic and does not require any command on the part of the user. In case of low fuel supply or faults the burner turns itself off and shuts down. We recommend that the fuel is reloaded before finishing completely in order to avoid irregular functioning of the burner. Adjustment of Minimum-Maximum Power Parameter Value 1 2 3 4 5 Power Burner 100 Kw 50 60 75 85 100 4.2 INSTALLATION WARNINGS The room in which the burner is installed must have openings towards the outside in compliance with current regulations. The installation area must be free of flammable objects, corrosive gases, dust and volatile substances that, if sucked up by the fan may obstruct internal ducts of the burner. The area must be dry and not exposed to snow, rain or ice. 4.3 FUEL SUPPLY The burner must be powered by the type of fuel for which it has been preconfigured (ONLY PELLET). We recommend only the use of good quality pellets, because low quality pellets determine lower performances, a higher ash content of ashes creating the need for much more frequent cleaning, and early wear of the burner components exposed to the fire and with the possibility of shut downs due to the sedimentation of non-combustible materials inside the burner. www.tradgardsteknik.se 0431-222 90 13

4.4 BOILER INSTALLATION FIGURE A : PREPARATION HOLE ON BOILER DOOR FIGURE B : ASSEMBLY DIAGRAM FOR BURNER ON BOILER 1 MAKE THE CASING HOLE JUST AS IN FIGURE A 2 FIX THE COLLECTING DOOR (4) EBK0001-P00 (OPTIONAL) FIGURE B WITH M8 SCREWS(2) WASHERS FOR M8 SCREWS (3) - M8 NUTS (6) 3 INSERT THE BURNER IN THE COLLECTOR (4) UNTIL THE LIMIT 4 FIX THE SCREW (7) www.tradgardsteknik.se 0431-222 90 14

5.0 SERVICE & MAINTENANCE 5.1 WIRING I 1. General ON/OFF power button 2. Cochlea loading power outlet with fan [Optional] 3. 220 Volt power outlet 4. Button for manual pellet loading 5. Supply motor 1 [external loading cochlea] 6. Connection for water and smoke sensor 7. Connection for self cleaning boiler kit [Optional] 8. Connection for thermostat 9. Connection for earthing www.tradgardsteknik.se 0431-222 90 15

5.2 STARTUP Checks that must be carried out when first ignited, and after any maintenance operations that have led to the disconnection of the system or an intervention on the safety devices or on parts of the burner. Before starting up the burner Check that the burner is fixed correctly onto the boiler with calibrations as configured in the factory. Check that the boiler and the system is filled with water or diathermic oil, that the valves of the hydraulic system are open and that the smoke exhaust duct is free and correctly sized. Check that the boiler door is closed, so that the flame is generated only inside the combustion chamber. Check the correct positioning of the cochlea and of the flexible tube of connection to the burner. Fill the Pellet container. Check if positioned correctly and check the temperature sensor connection. MAINTENANCE Check periodically the cleaning of the parts of the burner that will tend to get dirty because of bad pellet qua lity or because of an incorrect setting of the burner The burner requires periodical maintenance; we recommend a weekly cleaning of the combustion grill by the user. Also have an ANNUAL maintenance session done by authorized personnel. www.tradgardsteknik.se 0431-222 90 16

5.4 FAULTS-CAUSES-SOLUTIONS The burner is equipped with a self diagnosis system and in the case of a fault to the burner on the Display these fault messages appear In the following table we have indicated the most common faults with the possible solutions. FAULTS CAUSES SOLUTIONS Pellet Container Empty Fill the container Cochlea Cable Disconnected or Interrupted Restore the connection or find the interruption Ignition Failed Black Out Alarm Water Sensor Out of Service Fuel Empty Alarm Damaged Temperature Sensor Alarm Ignition Resistance Damaged Combustion Grill Clogged Internal Cochlea Power Supply Clogged Power failure Badly connected sensor Sensor damaged Pellet Container Empty Cochlea Cable Disconnected or Interrupted Sensor Damaged Sensor Badly Connected Substitute the Resistance (call a specialized technician) Remove grill and clean Check the Cochlea that supplies the combustion chamber, in case for some reason it may be clogged Restore power, if after having restored power the alarm continues, call a specialized technician Verify connection Change the sensor Fill the container Find Fault and Restore the Connection Change the Sensor Check the Connection! WARNING= IF THE PROBLEM PERSISTS WITH THE FAULTS DESCRIBED DO NOT LOOK FOR OTHER SOLUTIONS OTHER THAN THE SOLUTIONS PRESENTED HERE IN ORDER TO AVOID CAUSING IRREPARABLE DAMAGE TO THE BURNER NOT COVERED BY THE WARRANTY, BUT CALL A SPECIALIZED TECHNICIAN INSTEAD. www.tradgardsteknik.se 0431-222 90 17

6.0 PRECONFIGURED PARAMETERS 6.1 PRECONFIGURED TECHNICAL PARAMETER BURNER PRECONFIGURED TECHNICAL PARAMETERS 100 Kw Burner with Pellet Comb. Delta Temperature Control 02 Delta Temperature Wait 05 Ignition Attempts 1 Lamp Time 05 Vacuometer Control OFF Pellet Thermostat Control OFF Ext. Thermostat Enablement OFF Water Temperature Visualization ON 100 Kw Burner with Other Comb 6.2 PRECONFIGURED GENERAL PARAMETERS BURNER PRECONFIGURED TECHNICAL PARAMETERS 100 Kw Burner with Pellet Comb. 100 Kw Burner with Pellet Comb. Maximum Ignition Time 15 15 Flame Stabilizing Time 001 001 Time between Cleanings 060 060 Brazier Cleaning Time 55 55 Alarm Delay 120 120 Lux Minimum Start-up 100 100 Lux Turning Off 60 60 Time before Resistance 04 04 Manual Loading Time 2 2 TIM (Thermic Shutting Off Time) 00 00 TIM LUX Neutral Zone 80 80 TIM Switching Off 15 15 Max. Cochlea Time 45,0 45,0 Cochlea Charging Time 00,8 00,8 Cochlea Operating Time 01,5 01,5 Cochlea Cleaning Time 01,5 01,5 Cochlea Time Power 1 00,6 00,6 Cochlea Time Power 2 01,5 01,5 Cochlea Time Power 3 02,0 02,0 Cochlea Time Power 4 02,7 02,7 Cochlea Time Power 5 03,7 03,7 Vacuum during Loading 46 46 Vacuum during Operation 42 42 Vaccuum during Cleaning 99 99 Power Vacuum 1 38 38 Power Vacuum 2 39 39 Power Vacuum 3 42 42 Power Vacuum 4 44 44 Power Vacuum 5 45 45 Configured Water Temperature 60 60 www.tradgardsteknik.se 0431-222 90 18