Natural refrigerants - naturally efficient

Similar documents
Winter sports fun all year round, thanks to natural refrigerants

Natural refrigerants: current developments and trends

Medal-worthy natural refrigerants

Natural refrigerants: small applications with great potential

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Chapter 10. Refrigeration and Heat Pump Systems

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

HFCs or the Old Refrigerants - what is the best Choice?

Ammonia. Background on ammonia as a refrigerant

Thermodynamics I. Refrigeration and Heat Pump Cycles

Chapter 11 REFRIGERATION CYCLES

Chapter 2. Alternatives to HCFCs and their Characteristics

CHAPTER 1 INTRODUCTION

A Comparison Between Refrigerants Used In Air Conditioning

Hydrocarbons as refrigerants

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Chapter 11 REFRIGERATION CYCLES

Thermodynamics II Chapter 5 Refrigeration

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

The Problem of Counterfeit Refrigerants

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Oyelami S., Bolaji B. O.

March 10, 2016 San Joaquin Valley RETA Meeting

CHAPTER 1 INTRODUCTION

Low GWP alternative refrigerants to R404A

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

Refrigerants by Nature

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

11/22/2014. (c) DR.A.M.SURENDRA KUMAR

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

Alternative refrigerants or HFCs: an obvious choice? Safety first when choosing a refrigerant!

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Global Solutions for Ammonia Industrial Refrigeration

Guidance for Stationary Refrigeration & Air-Conditioning

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Brazed Plate Heat Exchanger for CO Applications

Making equipment decisions

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Refrigerant trends especially focusing on CO 2

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Design of LPG Refrigeration System

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Evaluation of HCFC Alternative Refrigerants

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

COLD. Basic Training Course II. November ESSE - Wilhelm Nießen

Synthetic or Natural?

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Alternative Refrigerants For Household Refrigerators

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

The natural solution for domestic refrigeration

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

investment in R&D, the commitment to - name.

Path into a green future

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Refrigerants for commercial refrigeration applications

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

η second law = Second law efficiency

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Scroll Chillers Transition from HCFC-22 to HFCs

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Natural Choice -- Ammonia

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Transcription:

Natural refrigerants - naturally efficient Operating systems with natural refrigerants for energy efficiency Frankfurt (Main), 10/11/2016. Whether energy transition in Germany or Energy Efficiency Act in Austria - from an environmental and economic point of view, it is becoming ever more important for companies in Europe and worldwide, to use energy efficiently. An increasing number of planners, builders and operators of refrigeration systems and air-conditioning systems are recognizing the cost reduction potential that energy efficient refrigeration technology has to offer. Efficient system performance is evident in the operating costs and is also dependent on the choice of refrigerant. Natural refrigerants can score highly here: they are available in unlimited quantities, and are sustainable. Moreover, they are very inexpensive and can be used in virtually any refrigeration application. With an ODP of 0 and a global warming potential between 0 and 3 they are also environmentally friendly. In the following interview Michael Elsen, Sales Manager of eurammon member Kreutzträger Kältetechnik GmbH & Co. KG, explains why the use of natural refrigerants have a positive effect on the energy efficiency of refrigeration systems. 1. The refrigerant is the central work and operating material of each refrigeration system and thus plays a significant part in their performance. How large an influence does the refrigerant have on the energy efficiency of the system? The refrigerant has influence on the energy efficiency of the refrigeration system. The thermodynamic properties determine the compressor size and the associated loss ratios, which also have a share of the total power requirement of the refrigeration system. The power requirement of the auxiliary drives such as pumps and the fans of the heat exchanger is by no means to be ignored. Direct cooling systems in which the refrigerant evaporates directly in the evaporator by heat absorption have a clear advantage over indirect systems that use a cold transfer medium, as these require an additional temperature difference for the heat transport, and pumping capacity for transporting the cold transfer medium. Modern plant designs allow the use of direct cooling systems with natural refrigerants in minimal quantities. Even with large industrial refrigeration systems in the megawatt 1

range, costly approvals under the Federal Pollution Control Act (BImSchG) can be avoided. 2. What are the physical properties of natural refrigerants which ensure that systems run energy-efficient? Natural refrigerants are characterized by a number of physical properties, especially with regard to energy efficiency. For example, an efficient refrigerant has a preferably high specific enthalpy of vaporization value. That is the amount of heat required to produce 1 kg of refrigerant to evaporate at a constant temperature. Furthermore, considerable variations in the cooling capacity can be deduced from the volumetric cooling capacity which depends on the material properties. The volumetric capacity illustrates how much cooling capacity can theoretically be realised with 1 m³ refrigerant. The higher the value, the less refrigerant has to be circulated for a certain cooling capacity. This in turn means that the energy losses in system components are also reduced. The isentropic exponent is the quotient of the specific heat at constant pressure divided by the specific heat at constant volume. With refrigerants that have a high isentropic exponent, high discharge gas temperatures occur, which is an advantage especially for the heat recovery. A low pressure ratio between the suction and condensing pressure has a positive effect on the volumetric efficiency and the energy demand. 3. Where in refrigeration and air conditioning applications is the use of natural refrigerants particularly energy efficient and why? Using natural refrigerants is economically feasible in particular in industrial refrigeration systems. In systems with a cooling capacity over 100 kw, the efficiency advantages justify the necessary increased investment needs. These costs are usually redeemed within two to five years compared to systems with synthetic refrigerants. The range of applications for refrigeration systems with natural refrigerants is constantly expanding. Even in applications where one would have resorted to synthetic refrigerants in prior years, natural refrigerants such as ammonia, carbon dioxide and propane are the 2

first choice today. At the moment, systems with natural refrigerants are being used primarily in industrial cooling applications. For example, in logistics, freezing tunnels, blast freezers, breweries, dairies and in food-processing establishments (slaughterhouses, ice cream factories, industrial bakeries etc.). There is also growing use in applications including heat pumps and supermarkets. In ammonia-operated systems for water cooling that are equipped with evaporative condensers or with air-cooled condensers, the extremely high vaporisation enthalpy of ammonia can be used for free cooling, meaning for heat transmission to the environment without compressor operation, as soon as the outside temperature allows this. 4. The natural refrigerant ammonia is in many areas of application the most economical refrigerant. Why is this, what makes ammonia particularly energy-efficient? The high specific vaporisation enthalpy of ammonia, low operating pressures in refrigeration systems, relatively low density and excellent heat transfer properties have a positive effect on pipe cross-sections, heat exchangers and refrigerant compressors. This also has a positive impact on the total power requirement of the system compared to synthetic refrigerants. Due to the high isentropic exponent of ammonia, the compressor discharge temperature can be up to 150 C, depending on the design of the system components. This temperature level is ideal for hot water production. Thus, hot water temperatures of about 60 C at a heating capacity of about 15 percent of the total cooling demand can be achieved without additional energy requirement. 5. In many industries, refrigeration system operators face the challenge of reducing greenhouse gas emissions of their commercial refrigeration systems or consider it necessary within the framework of energy policy to increase the energy efficiency of their systems. For which industry and business is the change to a natural refrigerant a particularly effective option? Ultimately, the use of natural refrigerants is not limited to particular industries and refrigeration systems. On the contrary the thermodynamic properties of the refrigerant, whose application limits must be considered with regard to the application, additionally provide numerous advantages in terms of environmental performance and energy efficiency. When choosing the refrigerant, the efficiency of the overall system concept 3

should not be forgotten. A restriction to certain applications would be fundamentally wrong. That is why we find systems with natural refrigerants in almost every capacity and application area these days. In order to develop the optimal solution for the operator, professionally qualified and experienced companies are essential, to objectively develop the tailored solutions to meet the needs of the operator, while taking environmental and economic factors into account. Caption: Michael Elsen, Sales Manager of eurammon member Kreutzträger Kältetechnik GmbH & Co. KG 4

((Systems)) Ammonia (NH 3) Ammonia has been successfully used as a refrigerant in industrial refrigeration systems for over 130 years. It is a colourless, liquefied compressed gas with a pungent odour. The refrigerant ammonia is known under the refrigeration designation R717 (R = Refrigerant) and is produced synthetically for use in refrigeration. Ammonia has no ozone depletion potential (ODP = 0) and no direct global warming potential (GWP = 0). Due to the high energy efficiency, contribution to the indirect greenhouse effect is comparatively low. Ammonia is combustible. However, the required ignition energy is 50 times higher than that of natural gas, and without a supporting flame ammonia will not continue to burn. In conjunction with the high chemical affinity of ammonia for atmospheric humidity it is rated as difficult to ignite. Ammonia is toxic, but has a characteristic acrid odour with a high warning effect and is noticeable in the air from a concentration of 3 mg/m³, which means that the warning effect occurs long before a harmful concentration builds up (> 1,750 mg/m³). Furthermore, ammonia is lighter than air and therefore rises quickly. Carbon dioxide (CO 2) Carbon dioxide is known in the refrigeration industry under the refrigeration designation R 744 and has a long tradition dating back into the early 19th century. It is a colourless, liquefied compressed gas with slightly acidic smell and taste. Carbon dioxide has a ozone depletion potential (ODP = 0) and, when used as a refrigerant in closed circuits, a negligible direct greenhouse effect (GWP = 1). It is non-flammable, chemically inert and heavier than air. Carbon dioxide has an anaesthetising and suffocating affect on humans only in high concentrations. Since the energy efficiency of carbon dioxide is low compared to other refrigerants, there has been a particular effort recently to optimize plant technology for specific applications and more efficient refrigeration systems are continuously under development to close this gap. Carbon dioxide is naturally present in very large amounts. Hydrocarbons Refrigeration systems with hydrocarbons such as propane (C3H8), in refrigeration technology also known as R 290, or butane (C4H10), known as R 600a, have been used worldwide for many years in. Hydrocarbons are liquefied under pressure, colourless and nearly odourless gases that have neither an ozone depletion potential (ODP = 0) nor a significant direct global warming potential (GWP = 3). Thanks to their outstanding thermodynamic properties, hydrocarbons are particularly energy efficient refrigerants. They are heavier than air and have an anaesthetising and suffocating affect in high concentrations. Hydrocarbons are flammable and may form explosive mixtures with air. Due to the existing security devices, however, refrigerant losses are near zero. Hydrocarbons are worldwide inexpensively available and are used particularly thanks to their ideal refrigeration properties in systems with low refrigerant charges. 5

Ozone depletion and global warming potential of refrigerants Ozone Depletion Potential (ODP) Ammonia (NH3) 0 0 Carbon dioxide (CO2) 0 1 Hydrocarbons (propane C3H8, butane C4H10) 0 3 Water (H2O) 0 0 Global Warming Potential (GWP) Chlorofluorocarbons (CFCs) 1 4,680 10,720 Partially halogenated hydrochlorofluorocarbons (HCFCs) 0.02 0.06 76 2,270 Perfluorocarbons (PFCs) 0 5,820 12,010 Partially halogenated fluorocarbons (HFCs) 0 122 14,310 Ozone Depletion Potential (ODP) Ozone depletion is mainly caused by chlorine, fluorine or bromine in compounds, which are able to split ozone (O3) molecules and thus destroy the ozone layer. Ozone depletion potential (ODP) of a compound will be indicated as chlorine equivalent (ODP of a chlorine molecule = 1). Global Warming Potential (GWP) The greenhouse effect is caused by the ability of substances in the atmosphere to reflect the heat emitted by the earth back to the earth. The direct global warming potential (GWP) of a compound is measured as CO2 equivalent (GWP of a CO2 molecule = 1). About eurammon eurammon is a joint initiative of companies, institutions and individuals who advocate an increased use of natural refrigerants. As a knowledge pool for the use of natural refrigerants in refrigeration engineering, the initiative sees as its mandate the creation of a platform for information sharing and the promotion of public awareness and acceptance of natural refrigerants. The objective is to promote the use of natural refrigerants in the interest of a healthy environment, and thereby encourage a sustainable approach in refrigeration engineering. eurammon provides comprehensive information about all aspects of natural refrigerants to experts, politicians and the public at large. It serves as a qualified contact for anyone interested in the subject. Users and designers of refrigeration projects can turn to eurammon for specific project experience and extensive information, as well as for advice on all matters of planning, licensing and operating refrigeration plants. The initiative was set up in 1996 and is open to companies and institutions with a vested interest in natural refrigerants, as well as to individuals e.g. scientists and researchers. Internet URL: www.eurammon.com Kontakt eurammon contact eurammon Dr. Karin Jahn Lyoner Straße 18 D-60528 Frankfurt Tel.: +49 (0)69 6603-1277 Fax: +49 (0)69 6603-2276 Mail: karin.jahn@eurammon.com Press contact FAKTOR 3 AG Katarina Lisci Kattunbleiche 35 D-22041 Hamburg Tel.: +49 (0)40 679446-6187 Fax: +49 (0)40 679446-11 Mail: eurammon@faktor3.de In case of a publication, we are glad to receive a sample copy at the address of the press contact. 6