INSTRUCTIONS FOR. Special Polypro Acid Resistant. Manifolds PPE SOUTH

Similar documents
Lime Buster III. Model LB-300P IMS # (CIC1-LB300P) INSTRUCTION MANUAL

Rules for Safe Operation

PARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08

Installation, Operation and Maintenance Instructions

COBRA -H EXTRACTOR 120V

Automatic Water System Pump SERIES

Safety In Chemistry. Identified Risks and Hazards

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

17 U.S. gallon portable low profile drain with electric pump

LS-JRE OPERATION & INSTRUCTION MANUAL

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

Page 1 of 18. Part# /5/2013

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

PRE INSTALLATION PROCEDURES

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

Zep Dyna Clean Installation and Operator's Manual

COBRA -300H EXTRACTOR

HHP-300 EXTRACTOR 120V

BEFORE OPERATING THE MACHINE: WARNING

SERVICE REQUIREMENTS

HP310-C EXTRACTOR 120V

ADVANTAGE-100H-SC EXTRACTOR

Supplemental Installation & Operation Manual. THE COLDWELL Stainless Steel Cold Trap

Refrigerant Recovery Machine. Model No Operating Manual

BETACURE 100 CO-REACTANT

Tornado Operation & Maintenance Manual

COMET 419TR 3 GALLON SELF-CONTAINED EXTRACTOR OWNER S/OPERATOR S MANUAL PROUDLY DESIGNED AND MANUFACTURED BY

XLT-60 EXTRACTOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

EXTREME HP-1 Reverse Osmosis System

PREDATOR CXC150 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

TCPSeries Installation Operation & Maintenance

Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

4-GALLON MOBILE PARTS WASHER

INFORMATION & OPERATING INSTRUCTIONS

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Mixing Training Course P/N Rev. D

PREDATOR CXH100 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

R100 Oil-Less Refrigerant Recovery Unit

PRE INSTALLATION PROCEDURES

PARTS MANUAL. American Dish Service. ADS HIGH TEMP SINGLE RACK DISHMACHINE MODELS: HT-25 5 WIRE 110 Volt Control System

Commercial Spotter Model number PS35

Hoshizaki America, Inc.

TSS 15/55 Hi-Lift Vacuum

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

OPERATION & MAINTENANCE MANUAL TX600

Application: Response procedures for major and minor spills, including: organic solvents acids bases dry chemicals mercury hydrofluoric acid

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

JT-SB116JH-G-NA JT-SB116JH-W-NA

Models: GW/R-T GW/R-2-T GW/R-3-T

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Operator & Parts Manual Self_Contained Extractor ie U REV.05( ) INTERNATIONAL CLEANING EQUIPMENT

EXTREME 4 Reverse Osmosis System

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Installation and Operation Manual

Condensate Pump. Installation and Safety Instructions CP-NL20 CP-NL20-230

BLEACH 2 NET2QT(64FLOZ)1.89L

EXTREME 1 Reverse Osmosis System

3.5 GALLON PARTS WASHER

bleach1 Whites Stay Brighter Longer concentrated NET 2 QT (64 FL OZ) 1.89 L regular scent

3-1/2 Gallon Parts Washer

PARTS MANUAL. American Dish Service ADS HIGH TEMP SINGLE RACK DISHMACHINE MODEL: HT Blake Street Edwardsville, Kansas (913)

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Used Fluid Handling Portable Used Oil Gravity Drains

OWNER S MANUAL (English)

G45 FastTrack. Page 1 of 8

Advantage Series Bathing System Specifications

INSTALLATION & OPERATION MANUAL

CAUTION: EYE IRRITANT. Economy Size 32 FL OZ NET 1 QT (32 FL OZ) 946 ml KEEP OUT OF REACH OF CHILDREN SEE BACK PANEL FOR PRECAUTIONARY STATEMENTS

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

FIBERPRO SPOTTER CARPET. 3.5 Gallon Carpet Spotter Machine. Operator and Parts Manual E

CH250 AND CH251 CHILLERS

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

Operating Instructions

INDUSTRIAL - AQUEOUS PARTS CLEANER EM1435A AIR OPERATED

The Safest Connections...

AUC Cell Washer. User Manual

Transcription:

INSTRUCTIONS FOR LIMEINATOR DESCALER USE TO REMOVE & DISSOLVE SCALE, LIME, RUST & CALCIUM FROM MOLD FLUID PASSAGES Requires cleaning & neutralizing solutions. Removeable Pump Mounting Plate Easy fill 3 fitting Outlet - Inlet Manifolds included Special Polypro Acid Resistant Manifolds Integral Roto-Molded Handle Hi-Flow CPVC Plastic Pump with Thermal Protected Continuous Duty Motor. Built-in On-Off Switch. 1/5 H.P., 115 Volts, 18 G.P.M. Strong, leakproof Roto-Molded one piece Tank. Not welded sheets, no seams to leak! Plumbing Kit Includes an assortment of fittings, plugs, clamps and 50 ft. of heavy transparent PVC fiber reinforced hose. 4 Rubber Wheel Swivel Casters DO YOU NEED A CLEANING ACID AND A NEUTRALIZER? Non-acid solvents won t attack mineral scale as well as a designed acid. Also, the EPA requires acids to be neutralized before disposal. Neutralization is simple as the acid changes color when it s time to strengthen or dispose of used acid solutions. CAUTION: Always follow chemical suppliers instructions. Copyright Plastic Process Equipment, Inc 2015 SPECIFICATIONS Tank: Seamless Roto-Molded MDPE Tank Capacity: 17 gallons Operating Capacity: 6 to 13 gallons Max Operating Temperature: 140 F Fluid Connections: 1/2 N.P.T. Pump Motor:1/5 H.P., 3450 RPM, 115 Volt with 8 ft. grounded line cord, 18 G.P.M. Open Discharge with Reset Button Integral grounded motor switch box mounted on Pump Motor Height Overall: 33 Tank Dimensions: 13 H x 17 W x 24 L Caster mounted, swivels, 4 dia.

FACTS, CAUTIONS & SAFETY ISSUES: The Limeinator is a fluid recirculating device designed for use with cleaning or descaling solutions to chemically clean mold passages and heat exchangers. Because of the need the use cleaning chemicals, the use of which is beyond our control, we ask you to user to be extra cautious with it s handling!! Be certain the operator has read all handling and instructions from and has read all SDS (Safety Data Sheets) and more importantly the instructions from the cleaning chemical supplier for the chemical that will be used. Follow the chemical suppliers instructions for cleaning solution use and/or the neutralizer. FOR EXAMPLE HANDLING: A) Simple table salt can be a danger if thrown in someone s eyes, yet a small amount in warm water gargled can help heal a sore throat. B) Household bleach can be a serious danger if mishandled. Yet, as a properly handled product, it is a ideal clothes whitener and a great disinfectant and germ killer. C) Drano: If not properly used can cause eye injury, skin burns and attacks mucous membranes on contact. Directions for use must be followed. Also note each chemical product clearly says DANGER: Keep out of reach of children. Our point, don t let someone use this equipment that would not be capable or qualified to do so. Management should always supervise and instruct in the use of this descaling device and all chemical products used in the cleaning process. 2

KNOW YOUR WARING SIGNS AND SYMBOLS! Be aware of and always follow Safety Warnings & Symbols. Always read chemical suppliers instructions & SDS information. Always have SDS on hand for quick reference. SDS are included with all containers of Acid and Neutralizers. WARNING: Wear full eye and skin protection when using this device. Also be aware of the dangers when handling acid cleaners. Follow chemical suppliers label instructions. Read their labels! Wear eye, hand and body protection for your safety! WASH YOUR HANDS AFTER HANDLING ANY CHEMICALS. 3

REFER TO THE CATALOG FOR SAFETY ITEMS AVAILABLE. Neoprene Rubber Gloves #650NL560 Faceshield & Headgear #HFS378 & #HFS840 Disposable Coveralls Laminated Polypropylene #CVL-NWPXL ADEQUATE VENTILATION: The chemicals supplier repeatedly cautions to provide adequate ventilation! Avoid breathing dust or vapors. If adequate ventilation is not available, wear suitable respiratory equipment. 4

CLEAN UP & SPILLS: Read all chemical suppliers labels for any products used to descale or neutralize. Always read SDS (Safety Data Sheets) for precautions and instructions. Always be prepared to clean up spills. Have on hand spill absorbent products and/or neutralizer solution. Always have SDS available. Spag Sorb #SS200 Never invert the motor after use. Always keep upright. If removed, place it upright over a 5 gallon empty pail to avoid acids from entering pump motor which can cause damage. ELECTRICAL: Motor & Pump have warning stickers listed, so be aware of the danger that exists if the electrical system is worked on for any reason. Only use a qualified Electrician! 5

CAUTION: NO HOT FLUIDS! DO NOT ADD CLEANING SOLUTIONS TO HOT FLUIDS: Hot fluids above 120 F will damage the pump or can cause a damaging reaction with the acid cleaning solution. The pump is rated for 180 F, but the cleaning acid can only rise in temperature to between 130 to 140 F MAXIMUM. The neutralizing solution cautions not to add their product to water warmer than 110 to 120 F (32 to 49 C). You must allow your molds or heat exchangers to cool down below 120 F. The use of heated fluids is not necessary for the descaling process. ALLOW FLUIDS TO COOL DOWN BELOW 120 F. UNPACKING & SET UP: A) Be sure shipping container is not damaged. If it is, call the delivering carrier. B) Remove Limeinator from container. C) NOTE: The 50 feet of PVC filer reinforced hose and fittings are contained within the tank. D) Remove the wing nuts from the motor mounting plate. Remove the plate. Remove the hose and fittings from inside the tank. E) Replace the motor manifold plate and secure it tightly with the wing nuts. Careful not to damage the sealing gasket. BE SURE TANK IS EMPTY BEFORE USE. F) Make your connection to and from your mold with the hose and fittings supplied. CAUTION: Always use stainless worm gear hose clamps to ensure against leaks! DANGER: Be sure your mold passages are clear and/or empty of any other chemical solutions as mixing other chemicals with the descaling acid can prove to be hazardous. 6

MODIFICATIONS: WARNING! Do not modify this machine in any way. Do not add a heating or cooling device to this machine. Modifications of any kind not only void any warranty, but it can cause serious injury or damage to personnel or equipment. FILLING THE TANK: Fill the clean Limeinator with clear clean water up to the higher fill mark on the tank, approximately 13 gallons. Do not overfill, however as you circulate through your mold, you may need to add water. Take note! The pump will not circulate fluid until the water level rises 2 inches above the minimum 6 gallon level line. The lower fill line on the tank is the minimum fluid level that should be maintained, although the pump intake line is located within 1 inch off of the tank bottom, you still need a fluid reservoir. After hose and fitting connections are made, test run the system with plain water only which allows you to check for possible fluid leaks or that passages are not fully blocked. REFER TO ACID Suppliers cleaning instructions. Before you add acid cleaner, follow acid suppliers instructions carefully. DANGER: Always pour acid powder into the tank of water! Do not pour water onto dry acid powder!! Do not pour water onto dry acid powder!! Pouring water onto dry acid powder will start a dangerous chemical reaction causing splatter & fumes. 7

ADDING ACID POWDER: Follow acid powder instructions on the chemical container! A) Be sure you have on protective gear! Be ready to fix a leak or spill. Always use a small plastic scoop to pour acid into the tank. Do not pour out of the large container as overdosing or splashing may occur!! B) Add acid powder slowly thru the 3 diameter fill port on the tank top. A 1/2 pound per gallon of water mixture gives a 6% solution at about 1pH. The solution will turn purple. Follow Solventol instructions when mixing. C) Solventol 2409 Acid Powder turns purple in water. CAUTION: Too much acid could cause damage or injury! D) Be sure to seal 3 fill port before start up. E) Plug unit into 120 volt supply and unit is ready to energize. F) Check water lines for color. Purple is acidic and yellow indicates more acid may be needed. CAUTION: Do not add acid while motor is running! Shut pump off! 8

TO NEUTRALIZE ACIDS: Follow the chemical neutralizer suppliers instructions. With pump off add a small amount of Enprox 714 to neutralize the acidic water until solution turns yellow. Recirculate for a few minutes to neutralize solutions still in your mold passages. Before disposal, test solution with neutral litmus paper. 1) If paper remains purple, but darkens, the solution is neutral. 2) If the paper turns red the solution is still acidic. Add more neutralizer. 3) If paper turns blue, the solution is too alkaline and you should add a very small amount of acid and retest. Neutral solutions should be disposed of as required by local, state or federal regulations. In most cases the neutralized solutions are not considered hazardous. For more disposal information if needed call Oakite Regulatory at 1-800-526-4473. CAUTION: Never leave the acid solution in the Limeinator tank for long periods unused. Flush tank and mold passages with neutralized solution or clean fluids to evacuate acid cleaners. Be sure pump has been flushed with clean water also. When you remove pump and motor mounting plate, set entire unit upright on a 5 gallon empty pail. Always keep motor and pump upright! DANGER: STORAGE Do not store in metal. Do not store acids or alkaline products in metal containers as they will eat through metal! Neutralizer will attack aluminum! 9

PLUMBING KIT INCLUDES: A) 50 ft. of #102-08 heavy transparent PVC Fiber Reinforced Fluid Hose. B) 16 ea. plastic fittings 1/2 N.P.T. x 1/2 dia. hose barb. C) 8 ea. plastic fittings 3/8 N.P.T. x 1/2 dia. hose barb. D) 8 ea. plastic fittings 1/4 N.P.T. x 1/2 dia. hose barb. E) 6 ea.1/2 N.P.T. blank plugs. F) 16 ea. #HSS-6 stainless steel hose clamps.