SPACE DETECTOR SP Presentation

Similar documents
Laser Distance Sensor Type M Analog-Output

new new Industrial plugs and sockets

High-Intensity cd Aviation Light

Open-area Smoke Imaging Detection (OSID)

BS-678BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

Installation Manual. Model 200QF 8/8 Model 200QF 8/ DC Edge III

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

LC1350 Level Controller

M7100 Pressure Transducer

PROJECT DATE FLANGE FINISH

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

INFRARED MODULATED BARRIERS

Introduction Page 2. Specifications Page 3. Dimensions Page 4. Included Parts and Accessories Page 6. Tweeter Installation Page 8

Half-Dome. the Design-Tower. Compact

Turbimax CUE21 / CUE22

Half Inch Round LED Rope Light

BC3250. Blowdown Controller

Reflective Beam Smoke Detector

BS-1015BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

VOICE ALARM-SERIES: LINEA LEN EN CERTIFIED LINE SOURCE LOUDSPEAKERS FOR USE WITH VOICE ALARM SYSTEMS.

Series M22 Signaling Beacons and Alarms

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

MASK4(T) & MASK6(T) Instruction manual

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Product Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW

New Beacon Series T & U

Installation and user manual for the BiWire / Conventional Repeater Panel

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

standards: standards:

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Netbiter Tank Sensor

OPTISENS TUR 2000 Technical Datasheet

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

signaling solutions visual signaling signal towers Audible signaling

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

HPNLS-LO. Installation Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

signaling solutions from auer signal

LED Flex Tube Assembly Guide

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Passive infrared ceiling sensor

Where technical minds provide innovative solutions

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

UP 258E11 OPTISENS OFFICE

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Amber In-wall & In-ceiling Speakers. P/Ns 24431, 24432, 24433, 24434, User's Manual

OEM Sensors for HVAC manufacturers Heat recovery Chiller

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

Engineering Guideline. pac- Carriers Type Universal

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Weight / 003 -Z M5 (SUCOFEED ¼ HF) bulk 10 pcs g / 5.25 oz.

High Pressure Conductivity Monitor

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

TrueAlert Notification Appliances

Attention Items: I. Brief Introduction

INSTRUCTION MANUAL TABLE OF CONTENTS

VAMP 120 & 121. Arc flash detection units. Product picture

optris TM Temperature Monitor for Infrared Sensors Operators manual

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

3kW 6kW, QUBE Fiber Lasers

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Dynaflex Hot melt hoses

EOTec 2C32 Installation Guide

LEAKSTOPPER RANGE Multizone water leak detection systems

CMT MANUAL 6. NMC SENSORS

Instructions for the fan motor control system with integrated wiring terminals SILVER C

REA 105 Arc Protection Module. Operator s Manual

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

MODELS 304GC, 304GCX, 314GC, and 314GCX

SONARRAY. Raising the Bar on Outdoor Entertainment

Installation Guide. Ceiling PIR Detector (311) Features and Connections

Altman Lighting Spectra Cyc UV 50 Specification

E3M-V. Mark Sensor. Applications

PANTHER. Condensate removal pump Installation and operating guide

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Open-area Smoke Imaging Detection (OSID)

Turbimax CUE21 / CUE22

Machine Protection Door Albany RP300 / RP300 Wide / RP300 USD. ASSA ABLOY Entrance Systems

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Transcription:

SPACE DETECTOR SP2-114 Presentation

1 CONTENTS 2 ULTRASOUND DETECTION 4 2.1 PRINCIPLE 4 2.2 FOR A PERFECT WORKING ORDER 4 3 DETECTOR PLACEMENT 5 3.1 PLACEMENT SITUATION 6 3.2 ZONE OF DETECTION 6 3.3 CITY CAR ON PARKED POSITION 7 4 DETECTOR MOUNTING OPTIONS 8 5 CONFIGURATIONS 9 5.1 STANDARD 9 5.2 DETACHED SENSOR 9 5.3 DISPLACED LED 10 5.3.1 FLEX 5.3.2 FINGER 10 10 6 DETECTOR MOUNTING 11 6.1 CANALIS BUSBAR SPECIFICATION 11 6.1.1 STANDARD RAIL 12 6.2 POSITIONING OPTIONS 13 6.2.1 DIRECT MOUNTING 13 6.2.2 HANGED 13 6.3 CABLE RUN 14 6.4 FLUSHED 15 6.5 FITTED 15 7 DISPLACED LEDS 16 7.1 THE FLEX 16 7.2 THE FINGER 17 8.1 STATES 18 8.2 COLORS OPTION 18 8.3 SINGLE/DOUBLE OPTION 18 9 ELECTRICAL CONNECTIONS 19 9.1 MAIN CONNECTION 19 9.2 DISPLACED LED 19 9.3 MASTER / SLAVE INTERCONNECTIONS 19 9.4 LOUD-SPEAKER 19 10 ACCESSOIRIES 20 10.1 CONNECTION 20 10.2 FIXING PARTS 20 11 FEATURES 21 12 SHORT SPECIFICATIONS 21 12.1 GENERAL 21 12.2 ELECTRICAL 21 12.3 LED INDICATOR 22 12.3.1 LED CHARACTERISTICS 22 2 /22

VEHICULE DETECTOR FIXED ON CANALIS BUS BAR VEHICULE DETECTOR FIXED ON AN CABLE RUN DISPLACED LEDS SYSTEM 3 /22

2 ULTRASOUND DETECTION 2.1 PRINCIPLE 2.2 FOR A PERFECT WORKING ORDER In several scenarios, the detector can report the wrong state. Both main scenarios are: 1. When the cone of broadcast is blocked by a cable run or a water main positioned in the red zone. In this case the detector is occupied instead of vacant. 4 /22

2. when the distance of reflection is the same that when the space is vacant. In this case the detector is vacant instead of occupied. 3 DETECTOR PLACEMENT To optimize the feature of the detector, it is important to place it in the center of the space. 5 /22

3.1 PLACEMENT SITUATION On this over view, we show the five most popular car s shape on situation. 3.2 ZONE OF DETECTION You easily can see that with central placement all type of car can be detected, even a small city car. 6 /22

3.3 CITY CAR ON PARKED POSITION The smart is the smallest car. If the detector has been fixed at the middle of the space the system can detect the car in any parked position. 7 /22

4 DETECTOR MOUNTING OPTIONS There are several supports to fix the detector SP2-114. CANALIS Refer to the chapter 6.1 CABLE RUN Refer to the chapter 6.3 FLUSHED Refer to the chapter 6.4 FITTED Refer to the chapter 6.5 8 /22

5 CONFIGURATIONS 5.1 STANDARD Conditions: No (or small) visual obstructing elements No longitudinal mounting obstructions 5.2 DETACHED SENSOR Conditions : Visual obstructing elements Longitudinal mounting obstructions 9 /22

5.3 DISPLACED LED Refer to the chapter 7 5.3.1 FLEX 5.3.2 FINGER Conditions : Visual obstructing elements No longitudinal mounting obstruction 10 /22

6 DETECTOR MOUNTING There are several supports to fix the detector SP2-114. 6.1 CANALIS BUSBAR SPECIFICATION This is the preferred mounting solutions due to his fast mounting and low cabling errors. The detector is fixed on the CANALIS using an aluminium fixing part with M16 cable gland.led orientation is made possible by rotating the whole detector. 11 /22

6.1.1 STANDARD RAIL 3000 MM SECTION LENGTH, 1000 MM BETWEEN OUTLETS Power plug Straight lengths constitute the basic structure of the line and are made up of: 1 an all-in-one carrier casing, crimp closed, forming a rigid beam made of sheet steel, hot galvanized on both sides. This casing also acts as the protective earth conductor (PE), equivalent in size to 11 mm2 of copper. As an option (code W), the casing is available in RAL 9001 white lacquered sheet steel, 2 a ribbon cable with two or four copper conductors, protected against corrosion by tinning, 3 one, two, three or five tap-off outlets, 4 an electrical jointing unit ensuring automatic and simultaneous connection of all live conductors, 5 a mechanical joining device made of galvanized sheet steel that makes the connection of two lengths rigid and resistant to bending. 12 /22

6.2 POSITIONING OPTIONS The detector needs to be hanged at 5 meters max from the floor. If the roof is higher, then the hanged option is necessary. 6.2.1 DIRECT MOUNTING 6.2.2 HANGED 13 /22

6.3 CABLE RUN The detector is fixed on the cable run using the M16 nut of the central M12 connector. LED orientation is made possible by rotating the whole detector. Angled female connector M12 male socket with wires 14 /22

6.4 FLUSHED The detector is mounting on the cover of a LEGRAND brand electrical box. The detector is supplied with a M16 cable gland. 6.5 FITTED The detector is mounting under an AGRO brand electrical box, type 9909.99. The detector is supplied with a M16 cable gland. 15 /22

7 DISPLACED LEDS The ideal arrangement for spaces those are hard to see. The LEDs can be put in a position that gives to the motorist a better view of vacant spaces. 7.1 THE FLEX The length of the flex can be chosen between 150mm and 2000mm. For more information, refer to the specific documentation. 16 /22

7.2 THE FINGER This option is made for all parking with reduced visibility. For more information, refer to the specific documentation. The FINGER detached LED is mounted on Ø20mm plastic electrician tubes. A dot of glue is used for the assembly. The internal diameter of the tube must be Ø17.6mm. 17 /22

8 LED 8.1 STATES Here is the presentation of the principal states. VACANT OCCUPIED or CLOSED VACANT but RESERVED OCCUPIED and in OVERTIME 8.2 COLORS OPTION On request, blue or white LED is available for specific places such as handicapped places. 8.3 SINGLE/DOUBLE OPTION Option Viewing angle Apparence Aisle traffic Simple LED Prefered option 180 unidirectionnal Double LED 360 bidirectionnal 18 /22

9 ELECTRICAL CONNECTIONS 9.1 MAIN CONNECTION The main connection regroups the power supply and the data bus in one M12 male connector or a cable gland at the center of the detector. Designation Color M12 pin POWER bus DATA bus +48V BROWN 1 0V BLUE 3 D+ WHITE 2 D- BLACK 4 9.2 DISPLACED LED The displaced LED is connected to the detector through a 4 poles M8 connector. The cable length must not be longer than 10m (30ft). 9.3 MASTER / SLAVE INTERCONNECTIONS The MASTER/SLAVE interconnection uses a 3m (3ft) 3 poles M8 male-female extension cable. The use of longer cable is forbidden. 9.4 LOUD-SPEAKER Connect a loud-speaker with 8Ω impedance or more on the dedicated M8 3 poles female connector. Use the supplied 1m (3ft) cable with the loud-speaker for connecting on a detector with voice option. Using longer speaker cable than 3m (3ft) is forbidden. 19 /22

10 ACCESSOIRIES 10.1 CONNECTION POWER SUPPLY and COMMUNICATION Art. Length 42670 60cm 42670.020 200cm MASTER/SLAVE INTERCONNEXION Art. Length 240 300cm Canalis plug KBC-10DCB40 Art. 2760 10.2 FIXING PARTS FIXATION FOR CANALIS Art. Material 3621 Aluminum 20 /22

11 FEATURES Detection range Detection methode 0.05m 4.0m (5.0m in optimal condition) 40KHz ultrasonic pulses Addressing 0 to 240 LED mode ON, OFF, flashing Variable LED intensity 12.5% to 100% Same device for space and entrance LED synchronization Field updatable embedded software 12 SHORT SPECIFICATIONS 12.1 GENERAL Size Ø142.5mm x H42.6mm (without connectors) Weight Housing material Operating temperature range Degree of protection 269g (0.6lb) ABS. Color RAL7035 (light grey) PMMA. Transparent -25 C to 55 C (-13 F to +131 F) IP44 (IP67 for M12 connector) 12.2 ELECTRICAL Power supply 48VDC nominal (43.0VDC to 48.5VDC) Insulation category Consumption Communication bus standard Class III 35mA max. RS-485, 2 wires (half-duplex) 21 /22

12.3 LED INDICATOR The state indication of the detector uses high intensity surface mounted LED with lens. Size: 21 x 3mm Viewing angle (half intensity): 30º Viewing angle: 180º 12.3.1 LED CHARACTERISTICS Color 100% Intensity (typ.) Wavelength Green 2x 1600mcd 525nm Red 1600mcd 626nm Amber 1600mcd 590nm Blue 700mcd 470nm 22 /22

1 SP2-114 / TECHNICAL DATA SHEET 1.1 GENERAL Size Ø142.5mm x H42.6mm (without connectors) Weight Housing material Operating temperature range Storage temperature range Relative humidity Altitude Degree of protection 269g (0.6lb) ABS. Color RAL7035 (light grey) PMMA. Transparent UL94-V0 compliant plastics -25 C to 55 C (-13 F to +131 F) -40 C to 85 C (-40 F to +185 F) 5-95%RH (not condensing) 0 to 2000m IP44 (IP67 for M12 connector) Note: water on the ultrasonic cells prevents correct detection SP2-114_technical data sheet / 20.04.2011 1 /2

1.2 ELECTRICAL Power supply 48VDC nominal (43.0VDC to 48.5VDC) Note: voltages above 49.0V destroys internal surge protection Insulation category Consumption Communication bus standard Class III 35mA max. RS-485, 2 wires (half-duplex) 1.3 ULTRASONIC Detection range Frequency Emission mode Sound pressure Total beam angle 0.05m to 4.0m (5.0m with optimal conditions) 0.16 ft to 13.2ft (16 ft with optimal conditions) 40KHz 400µs pulses 112dB @ 30cm (1ft) 55 (-6db) See 7 ULTRASOUND DETECTION for details 1.4 LED INDICATOR The state indication of the detector uses high intensity surface mounted LED with lens. Color and intensity can change slightly between productions due to components tolerances. Size: 21 x 3mm Viewing angle (half intensity): 30º Viewing angle: 180º SP2-114_technical data sheet / 20.04.2011 2 /2