NG4access ODF Platform Standard Chassis Installation Manual

Similar documents
Ribbon Breakout Kit Installation Instructions

Universal Connectivity Platform A Modular Approach to Infrastructure Design

DS3/STS-1 Protected Repeater System User Manual

TE Connectivity's AMP NETCONNECT Cable Management

Model T B Intraoffice T1 Repeater User Manual

Fiber Optic Products Catalog

Universal Connectivity Platform

Z-PACK TinMan 85 ohm Connector Overview

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Model IOR-MA4280/4285 T1 Repeater) Mounting Shelf (4-Inch, 28-Position) User Manual)

3 Scotch Mini-Weld Adhesive System User s Manual

Seal Kits for BUDI Enclosures

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Hydraulic Crimping Systems

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

FIBER OPTIC CONNECTOR CLEANERS

G4 Pulsed Fiber Laser

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

Qualification Test Report LC Duplex Adapter For LC Cutouts

Fibre Specification Standards

100% DATASHEET REV.1.0 Data center System. Datasheet. 3RU Slide-Out Fiber Enclosure Unloaded #51615 FHD-3UFRME. Tested.

A world of fiber Product overview

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

IFS SFP Tranceivers User Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

OPTICOM Fiber Optic Splice Module

Introducing Hermaphroditic Blade and Receptacle Connector

G4 Pulsed Fiber Laser

ST. KITTS CEILING FAN

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

4100U City and Relay Cards Installation Instructions

Hydraulic Crimping Head, PN 69069

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

SOLARLOK Interconnection System Installation Manual

MaxLite LED MICRO-T PANEL

Jan07 Rev B

C Electrical Connection Kit

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Cable Actuated Sensor Industrial Incremental Encoder Output

Hydraulic Crimping Heads and

Hydraulic Crimping Head, PN

Torrena 42 Ceiling Fan

6 Sheet Strip-Cut Shredder for Home/Office

Camarillo 52 Ceiling Fan

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Sound Cover [ , , , ]

TOUCHDOWN 48 CEILING FAN

Connecting and Routing the Cables

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

FEB 15 Rev C

TFS-FS1 Optical Leakage Detector. Operation Manual

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Neon LED Rope Light Installation Instructions

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

MaxLite LED Vapor Tight Linear Fixture

AMP SUPERSEAL 1.5 SERIES Connectors

JUL 17 Rev C

4120 Fire Alarm Network Reference

/Mar/2014 Rev A

Installing the 30-cm Column Heater/Cooler

Apr06 Rev A

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

Room Sensor for BACnet VAV Actuator

OWNERS MANUAL OPERATION GUIDE

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Environmental Monitoring SmartSlot Card

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

HPNLS-LO. Installation Manual

Standard and Customized Hand Tool Kits

Important Safety Notice

Introducing SlimSeal SSL Connector

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

100% DATASHEET REV.1.0 Data center System. Datasheet. 2 RU Slide-Out Fiber Enclosure Unloaded #51616 FHD-2UFRME. Tested. Description.

4009 Fiber Optic Link Option Installation Instructions

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

15R HARDWARE INSTALLATION GUIDE

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

AUTOMATION KIT. User s Manual. mysmartblinds.com/installation

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

AUTOMATION KIT. User s Manual. mysmartblinds.com/installation

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

IntelliDoX Operator Manual

Installation and Maintenance Manual IM 1038

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

PT9600. Cable Actuated Encoder Reel. General. Environmental

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

Transcription:

NG4access ODF Platform Standard Chassis Installation Manual TECP-90-703 Issue 1 8/2012 24939-A Content Page INTRODUCTION...1 1 PRODUCT DESCRIPTION...2 2 MAIN COMPONENTS...3 3 GROUNDING AND BONDING THE CHASSIS...4 4 CHASSIS INSTALLATION PROCEDURE...4 5 DOOR INSTALLATION AND OPERATION...6 6 WHERE TO FIND OTHER INFORMATION...8 6.1 Adapter Pack and Module Installation Instructions...8 6.2 Routing of Cables, Fibers, and Patch Cords....8 6.3 Phone Numbers, Mail Address, Email Address, and Product Portal...8 INTRODUCTION This installation manual describes the NG4access ODF Platform Standard Chassis and provides all information needed to install this product. This product is intended to be used in a Network Telecommunication Facilities and is suitable for installation in an Integrated Bonding Network or a Common Bonding Network. 300001749244 Rev A Page 1 2012 Tyco Electronics Corporation. All Rights Reserved.

Revision History ISSUE DATE REASON FOR CHANGE 1 08/2012 Original. Trademark Information Admonishments TE (icon), TE Connectivity (logo), and NG4access are trademarks of Tyco Electronics Corporation. Admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon, shown below. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. General Warning and Caution Statements Danger: Avoid eye exposure to unmated connectors. Unmated connectors may emit invisible laser radiation. Do not look directly into the end of a connector or an adapter port. Do not inspect with a magnifying device. To ensure safety, maintain caps on unmated connectors at all times. Caution: Handle cables with care. Fiber optic cable stubs should be handled with care throughout the installation procedure to avoid kinking and damage to cables. 1 PRODUCT DESCRIPTION The NG4access standard chassis is a 19-inch (48.26 cm) rack-mount, high-density fiber optic panel providing up to 576 terminations using LC adapters (or 288 SC terminations). A NG4access frame fully loaded with six standard chassis provides 3456 LC terminations per frame in a GR-449 compliant footprint. The chassis has features providing quick and easy access for connection and routing of fibers. Universal LC or SC adapter packs can be used with singlemode or multi-mode, APC or UPC connectors. LC packs have 12 adapters per pack (24 per access tray). SC packs have six adapters per pack (12 per access tray). Access trays can be moved toward front or rear to provide easy access to adapters from the front or rear side of the frame. Page 2 2012 Tyco Electronics Corportation. All Rights Reserved.

Access trays can also be loaded with cabled modules that snap into position. Each cabled module is pre-terminated with 24 LC or 12 SC adapter/connectors and fibers. Snap-in MPO and VAM modules are also available. Routing guides manage the fibers within the chassis, allowing an access tray to be opened or closed with no pulling or pinching of fibers. 2 MAIN COMPONENTS Figure 1 shows the main components of the standard chassis. They are as follows: 24948-A ACCESS TRAY NOTE: CHASSIS DOORS NOT SHOWN TRAY DOORS UNIVERSAL ADAPTER PACK (WITH LC CONNECTORS) ROUTING GUIDES MOUNTING TAB GUIDE STRIP GUIDE STRIP Figure 1. Main Components of NG4access Standard Chassis Access Tray can be moved toward front or rear to provide front or rear access to adapter packs with the associated fibers and connectors. In place of adapter packs, each access tray may hold a snap-in cabled module, MPO module, or VAM module. Tray doors swing out when an access tray is opened. Tray doors protect the individual access trays and provide laser eye protection. Universal Adapter Pack (LC or SC) can be used with singlemode or multi-mode, APC or UPC connectors. LC packs have 24 adapters. SC packs have 12 adapters, Routing Guide holds fibers in an optimal route when access trays are moved toward the front or rear of the chassis. Mounting Tab provides a physical interface for mounting the chassis on a frame. The tabs hold four mounting screws, two on each side. Page 3 2012 Tyco Electronics Corporation. All Rights Reserved.

Guide Strip provides cable management for fibers routed into the chassis on the front or rear of the frame. 3 GROUNDING AND BONDING THE CHASSIS The standard chassis uses thread-forming mounting screws to provide an electrical path between the chassis and the metalwork in which it is mounted. It is required that nonconductive coatings must be removed on the mating metal surfaces. Before installation the mating surfaces must be cleaned and coated with an antioxidant. 4 CHASSIS INSTALLATION PROCEDURE 1. Identify the frame location where chassis will be installed. Prepare area around mounting holes to provide a good ground (remove paint, clean, and coat with rust preventative). 2. Install screws and star washers into the two left side holes on the rack to hang the chassis on the rack, then install screws and washers in the right two holes. See Figure 2. 24940-A Figure 2. Installing Chassis in Frame Note: The frame has six locations for mounting of the chassis. Page 4 2012 Tyco Electronics Corportation. All Rights Reserved.

3. Install guide strips (provided) on front and rear of chassis. To install a strip, align the tabs on the strip with the slots on the chassis as shown in rear view in Figure 3, then press the radius limiters into place as shown. Repeat for all four locations. PRESS RADIUS LIMITERS INTO PLACE ALIGN TABS WITH SLOTS SLOT TAB 24942-A SIDE VIEW Figure 3. Installing Guide Strip On Standard Chassis Page 5 2012 Tyco Electronics Corporation. All Rights Reserved.

5 DOOR INSTALLATION AND OPERATION The standard chassis is equipped with a separately packed door that when installed protects the access trays when the chassis is not being accessed. To install the door: 1. Position the door at a 90 degree angle with respect to the chassis to align the tabs with the slotted hole, as shown in Figure 4. Push out slightly on the mounting arms to clear the brackets, allowing the tabs to slide into the slotted hole. 2. Retract the slides and flip up the door to snap the door into a closed position as shown in Figure 5. To open the door: 1. Grasp the door at the top and unsnap it from the chassis. 2. Allow the door to hang down in the full open position shown in Figure 6. To close the door: Retract the slides and flip up the door to snap the door into a closed position as shown in Figure 5. ALIGN TABS WITH SLOTTED HOLE 25073-A EXTEND SLIDES AND BEND TO CLEAR BRACKET Figure 4. Lining Up Door With Slots Page 6 2012 Tyco Electronics Corportation. All Rights Reserved.

25075-A RETRACT SLIDES AND FLIP UP TO CLOSE Figure 5. Closing Door 25074-A Figure 6. Door in Full Open Position Page 7 2012 Tyco Electronics Corporation. All Rights Reserved.

6 WHERE TO FIND OTHER INFORMATION 6.1 Adapter Pack and Module Installation Instructions Refer to the laminated cards hanging on the rear of the frame. 6.2 Routing of Cables, Fibers, and Patch Cords Note: This product is designed for use with RBR (Reduced Bend Radius) fiber. For cable routing on the rear of the frame, refer to the laminated cards hanging on the rear of the frame. For patch cord routing, refer to the laminated cards hanging on the front of the frame. 6.3 Phone Numbers, Mail Address, Email Address, and Product Portal Refer to banner below. PHONE: U.S.A. or CANADA Sales: 1-800-366-3891 Extension 73000 (Direct 1-952-917-3000) Technical Assistance: 1-800-366-3891 Extension 73475 (Direct 1-952-917-3475) WRITE: Tyco Electronics Corporation PO Box 1101, Minneapolis, MN 55440-1101, USA PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: telnet.tac@te.com PRODUCT PORTAL: PDF copies of this manual and other DELTAccess manuals are available for downloading using a visual regonition app on a smartphone and the QR code on the front of the frame Publication Number: TECP-90-703 Contents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. 13944-U Page 8 2012 Tyco Electronics Corportation. All Rights Reserved.