Manufactured specifically for Acid Waste systems. NSF certified to meet all performance standard of ASSE 1051

Similar documents
MAXI-VENT Air Admittance Valve

Operating Temperature/Pressure Graphs: Flow Sensors

Effective Date: October 2016 Void After: October Product: Air Admittance Valves File No. C-3803

SECTION PLUMBING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

The intelligent alternative for flue gas venting systems

Duraplus ABS for Secondary Loop Refrigeration Control Systems

SECTION HYDRONIC PIPING

$0.98 $ KITCHEN SINK STRAINER, 3-1/2" x BATH TUB DRAIN, 1-15/16" x 2-3/4" x $ $1.89

W Limestone Chips, 50 lb. bag 31.80

introduction Submittal Data Sheet CENTRA-GUARD POINT LEAK DETECTION

Aqua Balance. Direct Exhaust Venting Kit Instructions

Price Sheet 104. Dilution Tanks/Traps 1/1/2019

DUKE UNIVERSITY CONSTRUCTION STANDARDS

1-1/2 gallon square dilution tank, 1-1/2" or 2" inlet/outlet with 3" cleanout on top

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what

DIVISION 21 - FIRE SUPPRESSION

CHAPTER 10 TRAPS AND INTERCEPTORS

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Volume VI: Double Containment Piping Systems

Direct Exhaust Venting Kit Instructions

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

WATERSTONE ASSISTED LIVING AND MEMORY CARE

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

PLUMBING REQUIREMENTS

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

THE NEXT GENERATION CARBOY

TECHNICAL INFORMATION WEIGHTS & DIMENSIONS

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

POUNDS PER FOOT MINIMUM WALL (IN.) 4" 4.80".192" 1.87 lbs..267" 2.55 lbs..343" 3.22 lbs. 6" 6.90".276" 3.90 lbs..383" 5.29 lbs..493" 6.70 lbs.

TECHNICAL DATA. Wet 26a. February 22, 2009

ASAHI/AMERICA Leak Detection Basics

Building Utilities 1 Plumbing and Sanitary Systems

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Volume VI: Double Containment Piping Systems

Effective Date: September 2017 Void After: September 2018

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

B. Provide unique numbers for all applicable equipment, valves, and similar.

FAUCET REPAIR RV PARTS & ACCESSORIES RV PARTS & ACCESSORIES FAUCET STEMS FAUCET ESCUTCHEONS

2015 UPC Chapter 8 Indirect Wastes RV

DESIGN GUIDELINES AND TECHNICAL STANDARDS

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

SECTION PLUMBING PIPING

A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following:

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

INFACT CORPORATION WATERWORKS PRODUCTS FLEX REDUCER SPECIFICATION S TOLL FREE:

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

Matrix of changes for the National Standard Plumbing Code July 2013

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

A. Section Joint Sealants: Seal fixtures to walls and floors.

Residential Fire Protection Sprinklers & Systems

FAARM-Underground Facility. Conceptual Design Review. Mechanical Systems. Dunham Associates, Inc.

Product Catalog June 2012

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

DIVISION 21 - FIRE SUPPRESSION

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

Planting Irrigation

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

PLUMBING FIXTURES CHAPTER 27

Innovation in air purification unmatched air quality

SECTION DOMESTIC WATER PIPING SPECIALTIES

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS EXTRA HEAVY OR SERVICE

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Plumbing Fundamentals. Ron Grendzinski

Installation Instructions

A. This Section includes the following domestic water piping specialties:

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Division 11 - Equipment

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Chemtrol Thermoplastic Flow Solutions. PVC, CPVC, PP, and PVDF Piping Solutions. Chemtrol is a brand of

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

Sentry Air Systems, Inc.

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Joining Large PE Pipes in No Time at All: Integration of large connecting lines made easy

PRICE BOOK CONTENTS 010 PIPE

The BEST Plumbing Specialties. One Source. F 1 BRAIDED SUPPLIES

Oetiker Stepless TM Ear Clamps

Miniplast Shop 4. Industrial Welding Equipment

Willoughby Industries - Security Products

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

NONMETALLIC LIGHT FIXTURES

SENSEI Series Features

Transcription:

CHEM-VENT VENT

The CHEM-VENT VENT Manufactured specifically for Acid Waste systems Material is NSF 014 and ASTM D-4101 compliant NSF certified to meet all performance standard of ASSE 1051 Designed and tested to operate in temperature up to 210º F High temp/chemical resistance EPDM sealing o-ring

The CHEM-VENT VENT Simplify venting of island sink chemical basins installations in Labs while providing proper and instant protection against negative pressure

MATERIAL Flame Retardant Polypropylene (FR-PP) The material of choice in Acid Waste for the last 20 years Excellent resistance to chemicals and solvents Capable of handling exothermic reactions Durable & easy to install

DESIGN FEATURE The CHEM-VENT VENT Purposely designed for Acid Waste systems installation Direct mount on any molded FR-PP sanitary Tee Usable with either Mechanical Joint or Electrofusion FR-PP fittings Easily adaptable to CPVC, glass, PVDF or Duriron systems

DESIGN FEATURE Must be located a minimum of 4 above the arm of the trap 4 min Patented Studor screen keeps business end of the valve clean Extended tailpiece assures the 4 minimum requirement High chemical resistant EPDM O-ring is used

CONNECTING TO THE SYSTEM FR-PP & PP systems Will directly mount to molded sanitary Tees manufactured by: IPEX-GF/SLOANE-ORION-ZURN A D 4 Electrofusion Preparation, assembly, clamping and machine programming shall strictly follow the fitting manufacturer instructions for a single (or multiple if other fittings are simultaneously welded) 11/2 pipe to fitting weld. Mechanical Joints Preparation (e.g. grooving) and assembly shall strictly follow the fitting manufacturer instructions for an 11/2 MJ pipe to fitting connection. In both cases no special equipment other than what supplied by the fitting manufacturer is required.

CONNECTING TO THE SYSTEM A B C D 4 CPVC systems The CHEM-VENT can be easily installed on molded sanitary Tees manufactured by: SPEARS CHARLOTTE PIPE SPEARS (LabWaste ) Using the special PP pipe adapter offered by this manufacturer. CHARLOTTE (ChemDrain ) Solvent/cementing a small CPVC pup piece into the side socket of the Tee and then connecting that spigot to the valve s tail piece with a no-hub coupling or special MJ adapter. The CHEM-VENT will meet or exceed operational temperature & chem. resistance parameters of CPVC systems

CONNECTING TO THE SYSTEM GLASS systems A B C D 4 The CHEM-VENT can be easily installed on borocilicate glass sanitary Tee manufactured by Schott or CheFlowtronics All that is needed to install The CHEM-VENT on a Kimax (Schott) or Borodrain (ChemFlwotronics) Tee is a glass/pp adapter offered by all FR-PP acid waste system manufacturers. Although the CHEM-VENT will easily meet most operational temperature & chem. resistance parameters of applications using glass, this may not always be the case. Studor should be consulted before a CHEM-VENT is installed on a glass system.

CONNECTING TO THE SYSTEM GLASS systems A B C D 4 The CHEM-VENT can be easily installed on borocilicate glass systems MJ glass adapter Electrofusion glass adapter

CONNECTING TO THE SYSTEM FR-PVDF systems Will directly mount to molded MJ sanitary Tees manufactured by: IPEX-GF/SLOANE-ORION-ZURN A B C D 4 Although the CHEM-VENT will easily meet most operational temperature & chem. resistance parameters of applications using FR-PVDF, this may not always be the case. Studor should be consulted before a CHEM- VENT is installed on a FR- PVDF system. The CHEM-VENT CANNOT BE USED IN PLENUM DESIGNATED AREAS

CONNECTING TO THE SYSTEM FR-PVDF systems A B C D 4 The CHEM-VENT can be easily installed on FR- PVDF systems MJ FR-PVDF Sanitary Tee

CONNECTING TO THE SYSTEM DURIRON systems The CHEM-VENT can be easily installed on silicon/iron cast alloy systems A B C D 4 All that is needed to install The CHEM-VENT on a Duriron MJ or bell & spigot Tee is one of two adapters commercially available either through Duriron itself or all FR-PP acid waste system manufacturers. The CHEM-VENT will meet or exceed operational requirements (especially chem. resistance) of most systems using Duriron pipe & fittings.

CONNECTING TO THE SYSTEM DURIRON systems The CHEM-VENT can be easily installed on silicon/iron cast alloy systems A B C D 4 MJ PP adapter + No-hub coupling Score pipe; use asbestos rope or acid resistant oakum; caulk with hot led, led wool or caulking cement MJ glass adapter

SELECTION PARAMETERS The use of the CHEM-VENT VENT is: Recommended: in Acid Waste systems when: FR-PP, PP, CPVC or DURIRON pipe & fittings are installed Conditionally recommended: in Acid Waste systems when: Glass or FR- PVDF pipe & fittings are installed If FR-PP is deemed resistant to the chemical waste in a glass system, the Chem-Vent can be used on glass systems unless the system is installed in a return air plenum. Not recommended: In Plenum rated areas or on systems which couldn t t be otherwise vented to open air without the use of filtration in order to retain organic or inorganic compounds which, if inhaled in the concentrations and proportions found inside the piping system, would be harmful to humans or animals.

www.studor.com