Reason for Amendment (Statute, Rule, FBC, Industry) (11)(a)

Similar documents
Amend Base Code. Amend Base Code. Amend Base Code. Disposition. (Statute, Rule, FBC, Industry) Y/N

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

CITY OF PALM BEACH GARDENS ORDINANCE NO. 12, 2002

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

S 2758 S T A T E O F R H O D E I S L A N D

FIRE PREVENTION CODE

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

FIRE SERVICE FEATURES

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

Report on First Revisions with Statement June 2014 NFPA 101

New Facilities. Minimum Requirements

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

CHAPTER 7 ALTERATIONS LEVEL

The following are the Proposed Amendments to 2015 edition of the Fire Code (NFPA 1):

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

SECTION 915 CARBON MONOXIDE DETECTION

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

Codes and Standards FFP1510, BFST1510, ATCP1510

The following are the Proposed Amendments to 2015 edition of the Fire Code (NFPA 1):

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

FIRE PREVENTION AND PROTECTION*

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Definitions; contractors licensed by Board; examination; posting license, etc.

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973

2.2* NFPA Publications National Fire Protection Association, 1 Batterymarch Park, Quincy, MA

Residential Based Care Facility Guidelines

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

Iowa (2) Delete section and insert in lieu thereof the following new section:

Large Family Daycare Guideline

Consumer Fireworks in Georgia

Florida Senate SB 982 By Senator Bennett

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

BUILDING/FIRE CODE REFERENCES 2006 EDITION

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Chapter 2: Definitions

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS

Montgomery County Fire Marshal's Office

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Report on First Revisions with Statement June 2014 NFPA 101

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

Florida Building Code 2010

*HB0217* H.B. 217 H.B STATE FIRE CODE ACT AMENDMENTS. LEGISLATIVE GENERAL COUNSEL 6 Approved for Filing: C.R. Gilbert :11 PM 6

Schools and the Fire Code A Partnership for Safety

FIRE PREVENTION CODE. conditions hazardous to life and property from fire, hazardous materials, or explosion.

Fire & Life Safety Requirements For Fire Department Access and Water Supplies

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Narrative Reports As Regulated by 780 CMR, Section 903.0

Title: BFST1505 Syllabus

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

ORDINANCE NUMBER

FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

INTERIOR FINISHES AND FIRE PROTECTION SYSTEMS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

Fire Suppression Introduction Contact Information

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Agency for Health Care Administration

Site Plans. Fire Code Requirements

Washoe County Department of Social Services

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

TAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida Telephone: (954) , Fax: (954)

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

ORDINANCE NO

Fire Department Access and Water Supply

SECRETARY S CERTIFICATE

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

Osceola County Department of Fire Rescue and Emergency Medical Services

SPRINKLER ORDINANCE Town of Yarmouth, Maine Recodified: 1/15/98 Amended: 4/19/01 Amended: 6/18/15

Recommended Amendments to the 2009 International Building Code North Central Texas Council of Governments region

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

BULLETIN: Subchapter 4 Retrofit Requirements for Nightclubs

Outdoor Festival and Special Event Guidelines

Transcription:

Code Reference NFPA 1 1.1.2.1 Florida Specific Amendment Anytime a reference is made to NFPA 1 or NFPA 101 within this code it shall be the Florida specific version of NFPA 1 and NFPA 101. Reason for Amendment (Statute, Rule, FBC, Industry) 633.0215 Disposition SERC (Y/N) 1.3.2.5 (New) The Florida Building Code shall be referred to anytime a reference is made to the building code or to NFPA 220, Standard on Types of Building Construction in this Code or an adopted standard. 553.73 "Catch all" language to ensure the Florida Building Code is referenced. 1.3.3.3 Florida Fire Prevention Code and Florida Building Code Interrelation. The Florida Fire Prevention Code contains several provisions and requirements that may interrelate with the Florida Building Code. It is not the intent of this Code that such interrelation result in duplicate reviews and inspections by either the firesafety authority or the building official. The authority having jurisdiction over firesafety is responsible for enforcement of the Florida Fire Prevention Code hereof, and, in the event that a dispute arises regarding the enforcement of the Florida Fire Prevention Code as related to the enforcement of the Florida Building Code, the authority having jurisdiction over firesafety shall resolve the dispute by the procedure set forth in Chapter 633 and Chapter 553, Florida Statutes, as required by Section 633.01(5), Florida Statutes. 553.73(11)(a) (11)(a) In the event of a conflict between the Florida Building Code and the Florida Fire Prevention Code and the Life Safety Code as applied to a specific project, the conflict shall be resolved by agreement between the local building code enforcement official and the local fire code enforcement official in favor of the requirement of the code which offers the greatest degree of lifesafety or alternatives which would provide an equivalent degree of lifesafety and an equivalent method of construction. 1.7.4.1 If deemed necessary by a fire official for a complete, accurate, and thorough firesafety plan review or inspection, the fire official may request assistance from a building, electrical, plumbing, or similar specialty inspector; however, nothing in this rule gives authority or jurisdiction to any person other than a firesafety inspector certified under Section 633.081, Florida Statutes, to perform firesafety inspections required by law, rule, ordinance, or code. 633.081 10/2/2013 Page 1 NFPA 1

1.12.7 The authority having jurisdiction shall have the authority to issue permits for the operations in Table 1.12.7(a) Permits shall be required in accordance with Table 1.12.7(a) through Table 1.12.7(d). 1.13 Certificates of Fitness. (Deleted in entirely) 633.021 Addresses licensing regulated by DPBR or 633.021 NFPA 220, Standard on Types of Building Construction, 2009 edition; NFPA 472, Standard for Competence of Responders to Hazardous Materials/Weapons of Mass Destruction Incidents, 2008 633.0215(2) 2.2 edition. 633.34 &.35 ; add NFPA NFPA 1031, Standard for Professional Qualifications for Fire 633.081 1963 as Inspector and Plan Examiner, 2009 edition. NFPA 5000, Building Construction and Safety Code, 2009 edition. 553.72 strikethrough 2.4 NFPA 472, Standard for Competence of Responders to Hazardous Materials/Weapons of Mass Destruction Incidents, 2008 edition. NFPA 1031, Standard for Professional Qualifications for Fire Inspector and Plan Examiner, 2009 edition. NFPA 1141, Standard for Fire Protection Infrastructure for Land Development in Suburban and Rural Areas, 2008 edition. NFPA 5000, Building Construction and Safety Code, 2009 edition. ASCE 7, Minimum Design Loads for Buildings and Other Structures, 2005. 633.34 &.35 633.081 633.0215 553.72 ; Add NFPA 220 as strikethrough 3.1 The definitions contained in this chapter shall apply to the terms used in this Code. Where terms are not defined in this chapter or within another chapter, they shall be defined using the definition within the Florida Building Code. their ordinarily accepted meanings within the context in which they are used. Merriam-Webster s Collegiate Dictionary, 11th edition, shall be the source for the ordinarily accepted meaning. 553.72 10/2/2013 Page 2 NFPA 1

3.1.1 10.12.1.2 10.12.1.2.1 11.6.2.1 Where terms are not defined in this chapter, within another chapter, or the Florida Building Code, they shall be defined using their ordinarily accepted meanings within the context in which they are used. Webster s Third New International Dictionary of the English Language, Unabridged, shall be a source for ordinarily accepted meaning. Address numbers shall contrast with their background. Numerals shall be not less than three inches in height for residential buildings, structures, or portions thereof, and at least six inches in height for all other buildings, structures, or portions thereof. Where address identification is required by the fire official on other elevations of buildings, structures, or portions thereof, such numbers shall be not less than three inches in height for residential and at least six inches in height for all other buildings, structures, or portions thereof. Chapter 51 of NFPA 1 and NFPA 86 shall apply to crematory furnaces for humans and animals. NFPA 82 shall not apply. 553.72 11.10 In-Building Public Safety Radio Enhancement Systems 11.10.1 11.10.2 11.10.3 In-Building Public Safety Radio Enhancement Systems shall be provided in all new buildings where minimum radio signal strength for fire department communications is not achieved at a level determined by the AHJ. The AHJ is authorized to accept alternatives to In-Building Public Safety Radio Enhancement Systems when such alternative provides an equivalent level of fire department communication capability. The AHJ is authorized to approve as an alternative any In-Building Public Safety Radio Enhancement System installed and maintained in accordance with Annex O of this Code. using the strikethrough language from NFPA 1:3.1 (base code) NFPA 1 does not assign a size, but requires "legible and visible from the street". No change in NFPA 1, 12 ed. NFPA 86 Standard for Ovens and Furnaces Similar language added to NFPA 1, 12 ed Similar language added to NFPA 1, 12 ed Similar language added to NFPA 1, 12 ed Similar language added to NFPA 1, 12 ed 10/2/2013 Page 3 NFPA 1

13.3.2.5.1 Where the occupant load exceeds 100, the following assembly occupancies shall be protected throughout by an approved, supervised automatic sprinkler system in accordance with 13.3.1.2: (1) Bars with live entertainment (2) Dance halls (3) Discotheques (4) Nightclubs or similar usage (5) Assembly occupancies with festival seating [101:12.3.5.1] FBC 903.2 adding the following language to "Dance Halls" to align with FBC - (serving food or drink). Renumber to 13.3.2.7.1 Language adds clarity renumbered to 13.3.2.7 NFPA 1, 12 ed; Bars with live enterainment removed from base code. FBC requires A- 1 & A-3 with occupant loads >300; A-2 with occupant load >100 13.3.2.6.1 Where the occupant load exceeds 300 100, the following assembly occupancies shall be protected throughout by an approved, supervised automatic sprinkler system in accordance with NFPA 13 13.3.1.2: (1) Bars with live entertainment (1) (2) Dance halls (2) (3) Discotheques (3) (4) Nightclubs or similar usage (4) (5) Assembly occupancies with festival seating [101:13.3.5.1] adding the following language to "Dance Halls" to align with FBC - (serving food or drink). Renumber to 13.3.2.8.1 Language adds clarity renumbered to 13.3.2.8 NFPA 1, 12 ed; NFPA 1, 12 ed withdraws Bars with live entertainment and 13.3.1.2 13.3.2.18.1 All new one- and two-family dwellings shall be protected throughout by an approved automatic sprinkler system in accordance with 13.3.2.18.2. [101:24.3.5.1] 633.025(9) renumbered 13.3.2.20 NFPA 1, 12 ed The provisions of the Life Safety Code shall not apply to newly constructed one-family and two-family dwellings. However, fire sprinkler protection may be permitted by local government in lieu of other fire protection-related development requirements for such structures. While local governments may adopt fire sprinkler requirements for oneand two-family dwellings under this subsection, it is the intent of the Legislature that the economic consequences of the fire sprinkler mandate on home owners be studied before the enactment of such a requirement... 10/2/2013 Page 4 NFPA 1

13.3.2.18.1 13.3.2.18. 2 Where an automatic sprinkler system is installed, either for total or partial building coverage, the system shall be in accordance with Section 9.7 of NFPA 101; in buildings up to and including four stories in height, systems in accordance with NFPA 13R and with NFPA 13D shall also be permitted. [101:24.3.5.2] base code & renumber to 13.3.2.20.1 reference number changed to reflect deletion of section above; NFPA 1, 2012 ed. Has new language 13.3.2.24.2.3 The entire building shall be required to be protected by an approved automatic sprinkler system by December 31, 2019. within 12 years of adoption of this Code FS 553.895(2) ; renumber to 13.3.2.26.2.3 (2) Except for single-family and two-family dwellings, any building which is of three stories or more and for which the construction contract is let after January 1, 1994, regardless of occupancy classification and including any building which is subject to s. 509.215, shall be equipped with an automatic sprinkler system installed in compliance with the provisions of chapter 633 and the rules and codes adopted pursuant thereto. A stand-alone parking garage constructed with noncombustible materials, the design of which is such that all levels of the garage are uniformly open to the atmosphere on all sides with percentages of openings as prescribed in the applicable building code, and which parking garage is separated from other structures by at least 20 feet, is exempt from the requirements of this subsection. Telecommunications spaces located within telecommunications buildings, if the spaces are equipped to meet an equivalent fire prevention standard approved by both the Florida Building Commission and the State Fire Marshal, are exempt from the requirements of this subsection. In a building less than 75 feet in height which is protected throughout with an approved and maintained fire sprinkler system, a manual wet standpipe, as defined in the National Fire Protection Association Standard 14, Standard for the Installation of Standpipe, Private Hydrant, and Hose Systems, shall be allowed. 10/2/2013 Page 5 NFPA 1

13.3.2.24.2.4 All existing high-rise apartment buildings shall be subject to the provisions of Section 718.111 and 718.112, Florida Statutes, which shall supercede sections 13.3.2.24.2 through 13.3.2.24.2.3. FS 718.111 & FS 718.112 ; renumber to 13.3.2.26.2.4 Notwithstanding chapter 633 or of any other code, statute, ordinance, administrative rule, or regulation, or any interpretation of the foregoing, an association, condominium, or unit owner is not obligated to retrofit the common elements, association property, or units of a residential condominium with a fire sprinkler system in a building that has been certified for occupancy by the applicable governmental entity if the unit owners have voted to forego such retrofitting by the affirmative vote of a majority of all voting interests in the affected condominium. The local authority having jurisdiction may not require completion of retrofitting with a fire sprinkler system before the end of 2019. By December 31, 2016, an association that is not in compliance with the requirements for a fire sprinkler system and has not voted to forego retrofitting of such a system must initiate an application for a building permit for the required installation with the local government having jurisdiction demonstrating that the association will become compliant by December 31, 2019. 13.7.3.1.3 14.4.4 16.4.3 When not connected to a fire alarm system, fire alarm notification appliances shall not be used as duct detector visual or audible signal devices. There shall be no storage above any component of the means of egress unless it is on a separate floor or mezzanine constructed in accordance with the Florida Building Code. Fire Protection During Construction. This sub-section shall apply to both commercial and residential developments. 10/2/2013 Page 6 NFPA 1

16.4.3.1.3.1 18.2.3.2.1 Completion of the water mains and hydrants may be on an alternate schedule approved by the fire official. A fire department access road shall extend to within 50 ft (15 m) of at least one exterior door that can be opened from the outside and that provides access to the interior of the building. When required by the authority having jurisdiction, road(s) or parking lots providing access to the main entrance door(s) shall be considered access roads and shall comply with the requirements of 18.2.3.4.1.1 and 18.2.3.4.1.2. 18.2.3.4.5 Bridges. Ramps and Elevated Roadways. 18.2.3.4.5.3 Vehicle load limits shall be posted at both entrances to bridges, ramps and elevated roadways where required by the AHJ. & amend 18.2.3.4.5.1 & 18.2.3.4.5.2 to include "ramps and elevated roadways NFPA 1 2012 edition has this language. 18.2.3.5.3 Fire lanes shall be marked with freestanding signs that are readily visiblie to the street with the wording, NO PARKING FIRE LANE BY ORDER OF THE FIRE DEPARTMENT or similar wording. Such signs shall be 12 in by 18 in. with a white background and red letters and shall be a maximum of seven feet in height from the roadway to the bottom part of the sign. The signs shall be within sight of the traffic flow and be a maximum of 60 feet apart., Possible Declaratory Statement but remove the word "freestanding" & add "that are readily visible to the street" May need to add after sign " or attached to the building where readily vissible to the street" 18.3.4.1 Hydrants Clearances of seven and one half feet (7 6 ) in front of and to the sides of the fire hydrant, with a four feet (4 ) clearance to the rear of the hydrant. Exception: These dimensions may be reduced by approval of the fire official. Clear Space Around Hydrants. A 3 ft (914.4 mm) clear space shall be maintained around the circumference of fire hydrants except as otherwise required or approved. NFPA 1, 2012 ed re-number to 18.5.3 requires 36 in clearance 10/2/2013 Page 7 NFPA 1

18.3.4.2 18.4.1.3 (New) Fire Protection Appliances Clearances of seven and one half feet (7 6 ) in front of and to the sides of the appliances. Exception: These dimensions may be reduced by approval of the fire official. Section 18.4 shall be considered a recommendation for construction of one and two-family located on in-fill lots in existing neighborhoods and subdivisions. 20.3.4 Day-Care Occupancies Homes 20.3.4.1.1 In new day-care homes, The requirements of Section 16.6 of NFPA 101 shall apply to day-care occupancies homes in which more than 3, but not more than 12, clients receive care, maintenance, and supervision by other than their relative(s) or legal guardian(s) for less than 24 hours per day, generally within a dwelling unit. (See also 16.6.1.4 of NFPA.) [101:16.6.1.1.2] Licensing standards; child care facilities. Licensure of family foster homes, residential child-caring agencies, and child-placing agencies; public records exemption New amendment to 2010 FFPC & 69A-60 633.022 Uniform firesafety standards:...residential and nonresidential child care facilities, facilities for the developmentally disabled,... 69A-36 & 69A-41 use "Child Care Facilities" 20.3.4.1.2 In existing day-care occupancies homes, the requirements of Section 17.6 of NFPA 101 shall apply to existing day-care occupancies homes in which more than 3, but not more than 12, clients receive care, maintenance, and supervision by other than their relative(s) or legal guardian(s) for less than 24 hours per day, generally within a dwelling unit. An existing day-care occupancies home shall be permitted the option of meeting the requirements of Section 16.6 of NFPA 101 in lieu of Section 17.6 of NFPA 101. Any existing day-care occupancies home that meets the requirements of Chapter 16 of NFPA 101 shall be judged as meeting the requirements of this chapter. (See also of 17.6.1.4 NFPA 101.) [101 :17.6.1.1.2] 10/2/2013 Page 8 NFPA 1

20.3.4.1.3 20.3.4.1.4 In new day-care occupancies homes, where a facility houses more than one age group or one self-preservation capability, the strictest requirements applicable to any group present shall apply throughout the day-care occupancy home or building, as appropriate to a given area, unless the area housing such a group is maintained as a separate fire area. [101 :16.6.1.1.3] In existing day-care occupancies homes, where a facility houses clients of more than one self-preservation capability, the strictest requirements applicable to any group present shall apply throughout the day-care occupancy home or building, as appropriate to a given area, unless the area housing such a group is maintained as a separate fire area. [101 :17.6.1.1.3] 20.3.4.1.6 Places of religious worship shall not be required to meet the provisions of Section 16.6 or Section 17.6 of NFPA 101 where operating a day-care occupancy home while services are being held in the building. [101 :16.6.1.1.5; 101 :17.6.1.1.5] 20.3.4.2.3.5.3 Artwork and teaching materials shall be permitted to be attached directly to the walls in accordance with the following: (1) In new day-care occupancies, homes, the artwork and teaching materials shall not exceed 20 percent of the wall area in a building that is not protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 13.3. [101:16.7.4.3] (2) In existing day-care occupancies, homes, the artwork and teaching materials shall not exceed 20 percent of the wall area in a building that is not protected throughout by an approved automatic sprinkler system in accordance with Section 13.3. [101:17.7.4.3(1)] (3) The artwork and teaching materials shall not exceed 50 percent of the wall area in a building that is protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 13.3. [101:16.7.4.3] 10/2/2013 Page 9 NFPA 1

34.1.1.2 This chapter shall not apply to the following: (1) Unsprinklered buildings, except certain rack storage arrangements protected by high-expansion foam systems in accordance with this chapter (1) (2) Storage of commodities that, with their packaging and storage aids, would be classified as noncombustible (2) (3) Unpackaged bulk materials such as grain, coal, or similar commodities but excluding wood chips and sawdust, which are addressed in Chapter 31 (3) (4) Inside or outside storage of commodities covered by this Code, except where specifically mentioned herein (e.g., pyroxylin plastics) (4) (5) Storage of high-hazard materials covered by this Code, except where specifically mentioned herein (5) (6) Storage on plastic shelves on racks (6)* (7)* Miscellaneous tire storage (7) (8) Combustible fiber storage, which is covered in Chapter 45 (1) deleted from NFPA 1, 2012 ed therefore no need for Florida specific amendment 50.4.4.3 60.1.5.1.1 60.1.5.1.2 New Automatic fire-extinguishing systems shall comply with UL 300, Standard for Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Areas, or other equivalent standards and shall be installed in accordance with the requirements of the listing. [96:10.2.3] Exception: Existing installations may remain in place subject to the approval of the fire official. Permits may shall be required to store, dispense, use, or handle hazardous material in excess of allowable quantities specified in Section 1.12. A permit may shall be required where a material is classified as having more than one hazard category if the quantity limits are exceeded in any category. NFPA 1, 2012 ed has new language to address existing systems. 10/2/2013 Page 10 NFPA 1

60.1.5.1.3 Permits may shall be required to install, repair damage to, abandon, remove, place temporarily out of service, close, or substantially modify a storage facility or other area regulated by Chapter 60, except that permits shall not be required for the following: (1) Routine maintenance (2) Repair work performed on an emergency basis Table 60.2.5.5 65.11.3.14.4.2 Maximum Allowable Quantities of Hazardous Materials per Outdoor Control Area - Storage Liquid Gallons (pounds) 1950 500 Every egress door that has a latching device shall be provided with panic hardware complying with Chapter 14 and NFPA 101. [1124:7.3.14.4.2] This requirement shall not apply to: (a) Trailers, semitrailers, or metal shipping containers that are not normally occupied. (b) Within buildings or structures also used for other purposes in which seasonal retailers sell sparklers at retail from June 20 through July 5 and from December 10 through January 2 of each year, pursuant to Section 791.01(7), Florida Statutes. (c) In buildings or structures where novelties and trick noisemakers as defined in Section 791. 01(4)(c), Florida Statutes are offered for retail sale. No Statute, Rule, or Declaratory Statement 791, renumber to Table 60.4.4.1.2, renumber to 65.10.3.14.4.2 60.2.5.5 not in 2012 edition, 60.4.4.1.2 "Maximum Allowable Quantities of Hazardous Materials per Outdoor Control Area - Introduced in the 2007 FFPC but no amendment was proposed. No specific language in statute, changed in 2012 Code, now 65.10.3.14.4.2 65.11.4.4.1.1 65.11.4.4.1.2 Consumer fireworks, except for sparklers, novelties, and trick noisemakers as defined in Section 791.01(4)(b) and (c), F.S., stored in a building that is also used for other purposes shall be stored in a room or area used exclusively for the storage of consumer fireworks. When approved by the fire official, noncombustible materials shall be permitted to be stored in the same room or area with consumer fireworks. 791 791, renumber to 65.10.4.4.1.1, renumber to 65.10.4.4.1.2 No specific language in statute, 2012 65.10.4.4.1; requires 2 hours separation, may wish to include some language No specific language in statute 10/2/2013 Page 11 NFPA 1

65.11.4.4.1.3 Sparklers shall be stored or kept for sale in accordance with Section 791.055, F.S. 791.055, renumber to 65.10.4.4.1.3 791.055 Restrictions upon storage of sparklers. (1) Sparklers shall not be stored or kept for sale in any store: (a) In which paints, oils, or varnishes are manufactured or kept for use or sale unless the paints, oils, or varnishes are in unbroken containers. (b) In which resin, turpentine, gasoline, or flammable substances or substances which may generate vapors are used, stored, or offered for sale unless the resin, turpentine, gasoline, or substances are in unbroken containers. (c) In which there is not at least one approved chemical fire extinguisher ready, available, and equipped for use in extinguishing fires. (2) When sparklers are in storage to be offered for sale at retail, a sign shall be conspicuously displayed over the entrance to the room in which the sparklers are stored, which sign reads: CAUTION SPARKLERS-NO SMOKING. No person shall be in such room while in possession of a lighted cigar, cigarette, or pipe. 10/2/2013 Page 12 NFPA 1