Dräger REGARD 3900 Series Control System

Similar documents
Dräger REGARD -1 Control System

Dräger REGARD -1 Control System

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger QuadGard Control System

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Flame 5000 Flame Detection

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger REGARD -1 Control System

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Pac 3500 Single-Gas Detection Device

Dräger VVP 1000 System Components

Dräger X-am 2500 Multi-Gas Detector

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Pac 5500 Single-Gas Detection Device

Dräger Bump Test Station Calibration and Bump Testing

GS01 (wireless) Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

On-site & Shutdown Safety Service CSE Monitoring

Dräger PIR 7000 Flammable Gas Detection

Dräger Configuration and Evaluation Software

Dräger PIR 7200 Toxic Gas Detection Transmitter

The SharpEye 40/40I (IR3) Flame Detection

Training Authorised Gas Tester Level 1. Basic Information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger X-am 5000 Multi-Gas Detector

Dräger Bodyguard 1000 Warning Device

Dräger PEX 3000 Flammable Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Training Gas Detection Level 3 Maintenance and Repair

Dräger Flame 2700 (Multi-IR) Flame Detection

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 5000 Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Pac 7000 Single-Gas Detection Device

Dräger X-am 2500 Multi-Gas Detection

Tropic 2.0 ultrasonic nebuliser

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Pac 6000 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Pac 8500 Single-Gas Detection Device

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger Flame 2370 (UV&IR) Flame Detection

Powder Extinguisher ABC - composite Portable powder extinguishers

Dräger X-am 5000 Multi-Gas Detection

Dräger Flame 2100 (UV) Flame Detection

Portable wet chemical extinguishers

The SharpEye 40/40M (Multi IR) Flame Detection

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger FRT 1000 / ETR 1000 Location Devices

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Oxylog VE300 Emergency & Transport Ventilation

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

The SharpEye 40/40R (IR) Flame Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Oxylog VE300 Emergency & Transport Ventilation

Dräger VentStar Helix heated (N) plus Consumables and Accessories

VarioVac vacuum regulators Consumables and Accessories

Oxylog VE300 Emergency & Transport Ventilation

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger OR Lights Simply good light

Dräger Flame 2100 Flame Detection

Dräger Polytron 8000 Stationary gas detector (EC)

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger Flame 2500 Flame Detection

Dräger P4000 Pressure and Leak Testing

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger X-am 5000 Multi-Gas Detection

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

Dräger Pac 3500 Single-Gas Detection Device

Transcription:

Dräger REGARD 3900 Series Control System The devices of the Dräger REGARD 3900 series can be used as standalone controllers You can configure up to 16 measuring channels In addition, the modular setup enables you to customise the control units to the demands of your plant You can also embed further features to existing alarms Control buttons D-1130-2010 Display shows four channels at same time Status indicators for Input channels

02 Dräger REGARD 3900 Series Benefits Input modules You can connect up to four 4 to 20 ma transmitters with 2 or 3-core cables to an input module Up to a total of four input modules per controller can be installed Each module is populated with three relays These relays offer common Fault, Alarm 1 and Alarm 2 SPOC outputs In addition, the two alarm levels are fully configurable and can be set as rising or falling and latching or non-latching A third alarm is possible by using the relay module Relay module You can add two relay modules to the controller of the REGARD 3900 series Each module is populated with eight relays The first relay is dedicated as a Fault relay and cannot be reconfigured The remaining seven relays can be configured as Single, Common or Voting alarms An additional Alarm 3 is offered by the relay module along with a second fault threshold You acknowledge the alarm relays via the push buttons on the front panel The relays work with open-circuit current or close current Output module (Repeater module) Each 4 to 20 ma output repeats the signal of up to eight inputs This allows indication or recording of gas levels by other control units You can install up to two analogue output modules Configuration You configure your control unit quickly and easily with the configuration software Config 3900 via laptop or PC For new installations the configuration is prepared offline and uploaded during the commisioning For maintenance you can download the system configuration for a check You can get the neccessary cable as an accessory By using the push buttons on the front panel, the REGARD 3920 can be easily adjusted The configuration menu is easy to understand Mounting and installation The robust housing of REGARD 3900 and 3920 is dust-tight and protected against water jets (IP 65) Thus these control units can be installed in safe area The REGARD 3910 is equipped with built-in display and backplane You can easily mount it into a cabinet The modules can be intalled there as well Gateway solution The REGARD 3900 Modbus Gateway is an interface that converts a CAN bus protocol into a Modbus RTU protocol Due to this factor, the gateway allows the communication between the control unit of the REGARD 3900 series (CAN bus) with RVP 3900 (Remote Visualisation Panel) or other systems (Modbus RTU) Other possible gateways are: Modbus TCPIP and PROFIBUS Gateway You can use these to transfer data to third party control systems

Dräger REGARD 3900 Series 03 Dräger REGARD 3900 D-1130-2010 D-4258-2010 D-27777-2009 Details Dräger REGARD 3910 Dräger REGARD 3920 Dräger REGARD 3900/3910/3920 Modules In a Dräger REGARD 3900/3910/3920 you can use up to four input or relay modules Up to additional two output modules are possible

04 Dräger REGARD 3900 Series System Components Dräger PIR 7000 ST-11659-2007 The Dräger PIR 7000 is an explosion proof point infrared gas detector for continuous monitoring of flammable gases and vapours With its stainless steel SS 316L enclosure and drift-free optics this detector is built for the harshest industrial environments, eg offshore installations Dräger Polytron 7000 ST-3812-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and oxygen gas measurement applications on a single platform It is meeting the requirements of the compliance market as well as the high specification requirements of customized solutions Dräger PEX 3000 D-11158-2011 The transmitter Dräger PEX 3000 detects flammable gases and vapours in concentrations below their lower explosive limit Its DD-sensor provides a long-term stable measuring signal and responds to gas within a few seconds

Dräger REGARD 3900 Series 05 Related Products Dräger REGARD -1 ST-335-2004 The Dräger REGARD -1 is a standalone, self contained single channel control system for the detection of Toxic, Oxygen and Ex hazards The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head Dräger REGARD 2400 and REGARD 2410 ST-5647-2006 Dräger REGARD 2400 and 2410 are flexible small control units for detection of toxic gases and oxygen as well as combustible gases and vapours Combined with the Dräger transmitters or sensing heads Dräger REGARD 2400 or 2410 forms a low-maintenance gas detection system for reliable protection D-6806-2016 Dräger REGARD 7000 The Dräger REGARD 7000 is a modular and therefore highly expandable analysis system for monitoring various gases and vapours Suitable for gas warning systems with various levels of complexity and numbers of transmitters, the Dräger REGARD 7000 also features exceptional reliability and efficiency An additional benefit is the backward compatibility with the REGARD

06 Dräger REGARD 3900 Series Technical Data Type Control unit for location in a non-hazardous area Inputs all configuration via PC or laptop Gas and ranges see transmitter type for gas name, measuring range and units 4 to 20 ma transmitter with 2- or 3-core cable Outputs Alarm 1, Alarm 2 and Fault as standard Warning and inhibit relays on optional relay module Single, common or voted alarms on optional relay module Display Acknowledgeable relays on optional relay module Dräger REGARD 3900 and Dräger REGARD 3910 Dräger REGARD 3920 4 lines, 40 characters back-lit LCD 4 LEDs per channel (function, fault, Alarm 1 alarm 2) DC and AC power supply LEDs Inhibit-LED Large graphic display (4 x 62 mm, 64 x 128 pixel) Menu structure and messages in real text 3 push button navigation 4 LEDs per channel (function, fault, Alarm 1 alarm 2) DC and AC power supply LEDs Power supply External 24 VDC Dimensions (W x H x D) Dräger REGARD 3900 and 3920 Weight Ambient conditions Protection class Housing material Approvals Inhibit-LED Internal 110 / 240 VAC, 50 / 60 Hz ca 420 x 300 x 190 mm Dräger REGARD 3910 ca 300 x 225 x 20 mm Temperature 0 to 55 C Humidity 0 to 100 % rf, non-condensating ca 3 kg, depending upon type and installed power supply Pressure IP 65 ABS OV 700 to 1,300 hpa ATEX II (2) G, TRL 06 ATEX 21099X CE-Zeichen Electromagnetic Compability (Directive 89/336/EWG) SIL DNV/GL MED B+D SIL 1 Low Voltage Directive (72/23/EWG, 93/68/EWG) only Dräger REGARD 3910 only Dräger REGARD 3910 Ordering Information Dräger REGARD 3900 Dräger REGARD 3900 Basic Unit 42 08 780 Dräger REGARD 3900 (1x 4 to 20 ma Input Module + 2x Relay Module) 42 08 811 Dräger REGARD 3900 (1x 4 to 20 ma Input Module + 1x Relay Module) Dräger REGARD 3900 (2x 4 to 20 ma Input Module + 0x Relay Module) Dräger REGARD 3900 (2x 4 to 20 ma Input Module + 1x Relay Module) Dräger REGARD 3900 (2x 4 to 20 ma Input Module + 2x Relay Module) Dräger REGARD 3900 (3x 4 to 20 ma Input Module + 0x Relay Module) Dräger REGARD 3900 (3x 4 to 20 ma Input Module + 1x Relay Module) 42 08 810 42 08 812 42 08 813 42 08 814 42 08 815 42 08 816

Dräger REGARD 3900 Series 07 Ordering Information Dräger REGARD 3900 (4x 4 to 20 ma Input Module + 0x Relay Module) Dräger REGARD 3910 Dräger REGARD 3910 Display Board Dräger REGARD 3910 Mounting Plate for Modules Dräger REGARD 3920 Dräger REGARD 3920 Basic Unit Dräger REGARD 3900/3910/3920 Module 42 08 817 42 08 830 42 08 831 42 08 850 Dräger REGARD 3900/3910/3920 4 to 20 ma Input Module 42 08 782 Dräger REGARD 3900/3910/3920 4 to 20 ma Output/Repeater Module 42 08 797 Dräger REGARD 3900/3910/3920 Relay Module Dräger REGARD 3900/3910/3920 Accessories Dräger REGARD 3900/3910/3920 Modbus Gateway Dräger REGARD 3900/3910/3920 PROFIBUS DP Gateway Dräger REGARD 3900/3910/3920 Modbus TCPIP Gateway Dräger REGARD 3900/3910/3920 PSU 2,5 A Dräger REGARD 3900/3910/3920 PSU 5 A Dräger REGARD 3900/3910/3920 PSU 10 A Dräger REGARD 3900/3910/3920 CAN Interface Dräger REGARD 3900/3910/3920 Modbus RTU Dräger REGARD 3900/3920 Gateway Cable Dräger REGARD 3910 Gateway Cable Dräger Config 3900 PROFIBUS is a registered trademark of PROFIBUS and PROFINET International (PI) 42 08 784 SC 00 083 AG 01 100 SD 13 037 42 08 745 42 08 746 42 08 747 42 08 785 SC 00 083 SC 00 084 SC 00 085 on request

08 Dräger REGARD 3900 Series 91 02 376 1611-1 HQ PP Subject to modifications 2016 Drägerwerk AG & Co KGaA Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom REGION DACH Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Safety Asia Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377 9100 Fax +507 377 9130 contactcsa@draegercom