Model 9001, Alarm

Similar documents
Model 9001, Alarm

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model Combination Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model TWBS.EW.H Tempered Water Blending System

Model 7656WCC Eye/face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model TWBS.SHE Tempered Water Blending System

Model 7500EB Portable Eyewash with Heater

Model 1011/1011HPS Drinking Fountain

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 1900 Retrofit Bottle Filler

Model H1011.8/H1011.8HPS Water Cooler

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

INSTALLATION & TESTING MANUAL

Model 7611 Eye/Face Wash

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

3121FR Pedestal Mounted Drinking Fountain

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

INSTALLATION & TESTING MANUAL

H Barrier-Free Wall Mounted Electric Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

Model 1920/1920HPS/1920W Bottle Filler

ADA Compliant Wall-Mount Fountain and Bottle Filler

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

Comfort Series Instant Hot Water System

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

VENTILATION FAN WITH LIGHT AND HEATER

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

FLCH4R Garage and Utility Electric Heater

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Static Pressure Alarm For Hazardous Location Fume Hoods

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

INSTRUCTIONS FOR OPERATION AND CARE OF

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

VENTILATION FAN / LED LIGHT

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

e Bath Fan with Light User s Guide

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

XT Series Thermostats

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

(HSTAT Series) Instruction Manual

INSTALLATION INSTRUCTIONS

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

OPERATION & INSTALLATION MANUAL

TrueClean ToteCleaner

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Quest Power Electric Heat EHS 31 Pro

Flat Line Spray Systems Kits

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

DISCONTINUED. Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

e Bath Fan with Light User s Guide

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

Owner s Manual Phoenix FireBird

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

! WARNING. Before using product, read and understand instructions.

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

e Bath Fan with Light User s Guide

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

TUB AND SHOWER FAUCET

Heater Installation Kit

Installation & Operation Manual for WarmlyYours Riviera Towel Warmers

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

M Series Fan Filter Units

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9001, 9001.5 Alarm No. 2080202(31) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 10/17 9001 Alarm Series Page 1 of 6

RECOMMENDED TOOLS: Pipe joint sealant, screwdriver, pipe wrench, 14 AWG wire, 1/2"conduit and basic electricians tools for power connection. LOCATION OF UNIT: The Model 9001 Alarm Series may be mounted directly to the upper standpipe of a safety shower or wall mounted next to a shower or eyewash. The alarm should be clearly visible from several directions. ELECTRICAL SUPPLY: Model 9001 & 9001.5 120 VAC 50/60 HZ. 14 watts average power consumption. WARNING: Power shall be supplied by a dedicated circuit through a 10 AMP maximum breaker or fuse and should not supply power to any other devices. NOT FOR USE IN CLASSIFIED AREAS. WATER SUPPLY: Model 9001 2.4 gpm minimum required to activate flow switch. Model 9001.5 1.5 gpm minimum required to activate flow switch. Mount flow switch in supply line with flow in horizontal direction and switch stem extending vertically from tee. Mount switch with at least 6 of straight pipe on both sides to minimize turbulence in switch. TROUBLESHOOTING PROBLEM 1. Alarm horn and light do not operate. REPAIR CHECKLIST 1. a. Check incoming circuit for power and power from flow switch. 2. Horn sounds but light does not flash. b. Check that the direction of water flow corresponds to the arrow on the flow switch body. c. Check that the switch located on the junction box is in the on position. d. Check for continuity through the switch. e. Check all electrical connections. f. Check that water flow is sufficient. g. Faulty flow switch. Replace entire switch assembly. 2. a. Check wiring connections. b. Replace flashing light. 3. Light flashes but horn does not 3. sound. a. Check wiring connections. b. Make sure the alarm silencing switch is in the on position. 4. Alarm stays on. 4. a. Check wiring connections. b. Disconnect flow switch wires and test for continuity. 10/17 9001 Alarm Series Page 2 of 6

INSTALLATION PROCEDURE STEP 1: STEP 2: STEP 3: STEP 4: Choose a location for mounting the flow switch in the water supply line. The inlet and outlet ports of the flow switch must be a minimum of 6 inches from any tees or elbows in the water supply line. See attached installation drawing. Mount the flow switch assembly in the water supply line. The switch body must be in the vertical position with the water pipe horizontal. The water flow must be in the direction marked by the arrow on the flow switch body. Use pipe sealing compound on all water pipe connections. Choose a location for mounting the alarm assembly. The alarm housing should be positioned along a vertical axis at least 7 feet above ground for best visibility. The alarm may be mounted directly to a water pipe using the supplied bracket, washers and nuts. The alarm can also be bolted to a flat surface such as a wall using appropriate fasteners (not supplied). Using the wire crimp terminals (supplied), connect the alarm to the power supply per attached installation drawing. The purple wire is connected to the second normally closed contact and the pink wire to the second common contact of the flow switch and may be used for remote alarm activation. The signal from the purple wire will be zero voltage when water is flowing and supply voltage when no water is flowing. If a remote alarm is not used, the purple wire must be insulated at its free end. Leaving the two crimp terminals (supplied) connected will be sufficient insulation. NOTICE: ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC CODE USING TYPE 4 COMPLIANT EQUIPMENT. OPERATION AND TEST INSTRUCTIONS Test weekly. Instruct all employees in the use of emergency showers and eyewashes. STEP 1: Apply power to the alarm branch circuit. The alarm should remain OFF. STEP 2: Open the shower or eyewash flow valve. The alarm should sound and the light should flash shortly after water flows. STEP 3: Shut off the flow valve. The alarm should turn OFF. For more information on Haws products, see our website: www.hawsco.com 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 10/17 9001 Alarm Series Page 3 of 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. PARTS BREAKDOWN ITEM DESCRIPTION 1 FLOW SWITCH 2 120V LIGHT 3 SELECTOR SWITCH 4 FLOW SWITCH 5 LEGEND PLATE 6 PIEZO ALARM PART NO. SP154DPDT 0003225300 0005726705.3 0005726850 0004465585.2 0210000283 2 3 5 6 1 4 9001 9001.5 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER ECN: 5232 GC 0002080202 DRAWN DATE CHKD 9001/9001.5 ALARM DRAWING NO. REV CLF 3/17/93 APPROVED DATE A 31 FV 11/22/17 SCALE: 1:2.5 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2017 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. PAGE 4 of 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: 1. THE SIGNAL FROM THE PURPLE WIRE WILL BE SUPPLY VOLTAGE WHEN NO WATER IS FLOWING AND ZERO VOLTAGE WHEN THE FLOW SWITCH AND LOCAL ALARM ARE ACTIVATED. IF A REMOTE ALARM IS NOT USED, THE PURPLE WIRE MUST BE INSULATED AT ITS FREE END. LEAVING THE TWO CRIMP TERMINALS (SUPPLIED) CONNECTED WILL DO THIS. 2. INSTALLER MUST USE A THREAD SEALANT, SUCH AS APPLETON TLC3, RECOMMENDED FOR USE ON ELECTRICAL COMPONENTS ON ALL ELECTRICAL NPT CONNECTIONS. SEE SHEET 2 FOR CLAMP ASSEMBLY DETAIL SHOWER (REF) 5 of 6 PAGE GROUND (CUSTOMER) POWER SOURCE HOT CUSTOMER 120 VAC POWER SOURCE FLEX CONDUIT FLOW SWITCH (DPDT) (PINK) NC (PURPLE) NO (GRN) COM NC (RED) COM NO (BLK) NEUTRAL (WHITE) CAUTION: DO NOT DISASSEMBLE OR ROTATE THIS ASSEMBLY AT ANY JOINT AS DAMAGE WILL OCCUR 1-1/4 IPS OR 1/2" IPS FOR MODEL 9001.5 WATER SUPPLY NOTE FLOW DIRECTION ARROW (13") (RED) (BLK) SWITCH (RED) 1-1/4" UNIONS OR 1/2" UNIONS FOR MODEL 9001.5 (BY OTHERS RECOMMENDED) 6"MIN. 152mm STRAIGHT (3-5/8") 6"MIN. 152mm STRAIGHT C (CUSTOMER) LOAD FL LT (BLK) HORN (WHT) WIRING DIAGRAM FLOW SWITCH MUST BE MOUNTED IN HORIZONTAL POSITION 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY: MODEL(S) PART NUMBER ECN: 5232 JP DRAWN: DATE: CHK'D.: 9001/9001.5 ALARM REVISION CH 01/09/01 GC APPROVED: DATE: 31 FV 11/22/17 SCALE: 1:1 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 2 R 2017 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080202.D

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: 1 SNAP CLAMP TO BE INSTALLED FIRST FOR VERTICAL SUPPORT. 2 SCREWS INSTALLED FROM FRONT, WITH BOX DOOR OFF. 3 NUTS TO BE INSTALLED TO A TORQUE OF 12 IN-LBS MAX. 4X 8-32 SCREW 2 6 of 6 PAGE LID TO BE INSTALLED TO 3 IN/LBS TORQUE 4X WASHER 2X PIPE CLAMP MAX PIPE SIZE Ø1 5/8" 4X HEX NUT 3 BOX DOOR 2 SNAP CLAMP 1 4X WASHER CLAMP ASSEMBLY DETAIL C 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY: MODEL(S) PART NUMBER. ECN: 5232 JP DRAWN: DATE: CHK'D.: 9001/9001.5 ALARM REVISION CH 01/09/01 GC APPROVED: DATE: 31 FV 11/22/17 SCALE: 1:1 DRAWING TYPE: INSTALLATION SIZE: A SHEET 2 OF 2 R 2017 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080202.D