Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Similar documents

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

Transcritical CO2 Bottle Cooler Development

Low GWP Refrigerants for Air Conditioning Applications

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Application of Air Source Variable Refrigerant Flow in Cold Climates

lmprovin Industrial Refrigeration -!nergy Efficiency

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Performance Optimization of the Evaporative Condenser Design

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

DISCLOSURE THIS GUIDEBOOK WAS PREPARED BY THE IRC. NEITHER THE IRC, NOR ANY PERSON ACTING ON BEHALF OF THEM:

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Thermodynamics II Chapter 5 Refrigeration

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

Performance of an Improved Household Refrigerator/Freezer

Thermodynamics I. Refrigeration and Heat Pump Cycles

Case 13 Food Storage & Processing Center

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

R-404A Alternative with Low Compressor Discharge Temperature

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Air Conditioning Clinic

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Partial Load Performance Of Refrigeration System

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Refrigerator and Heat Pump Objectives

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

ICE CHILLER Thermal Storage Products... F2. Benefits... F4. Proven Technology... F7. Construction Details TSU-M - Internal Melt Application...

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

HVAC Water chiller selection and optimisation of operation

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

How to Cut Chiller Energy Costs by 30%

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

Impact of TXV and Compressor in the Stability of a High-End Computer Refrigeration System

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

1 /35 2 /35 3 /30 Total /100

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

THERMAL ICE STORAGE: Application & Design Guide

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Binoe E. ABUAN, Menandro S. BERANA, Ruben A. BONGAT. University of the Philippines Diliman, Quezon City, Philippines

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Chiller Plant Design. Application Guide AG McQuay International. Elevation Difference. Column Height When Pump Is Off

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Owner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 )

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Air Conditioning Inspections for Buildings Condensers

R07. Answer any FIVE Questions All Questions carry equal marks *****

The Refrigeration Cycle

Energy Use in Refrigeration Systems

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Chapter 14, Problem 27.

The Refrigeration Cycle

ACHIEVING ENERGY-EFFICIENT DATA CENTER COOLING: DOES REDUCING FAN SPEED ALWAYS RESULT IN ENERGY SAVINGS?

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Fundamental Principles of Air Conditioners for Information Technology

Effect of magnetic field on the performance of new refrigerant mixtures

Ice-System Operations Brief review of Refrigeration principals for Cold and Warm Brine Refrigerant Solution Ice-Surface Formation Procedure

The results of an experiment with a new energy-saving technology tested on five skating rinks

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

ENERGY EVALUATION OF A

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Closing the Loop What s best for your system?

Chapter 9. Refrigeration and Liquefaction

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Modeling And Testing Of R23/R134a Mixed Refrigerant System With Water Cooled Separator For Low Temperature Refrigeration

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

ASHRAE JOURNAL ON REHEAT

Environmentally friendly refrigeration systems for industrial use

Week 9. Refrigeration Cycles I. GENESYS Laboratory

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

System Considerations for Refrigerant Blends with Temperature Glide

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

Chapter 10. Refrigeration and Heat Pump Systems

Refrigeration Systems and Accessories

Transcription:

energy center Paper Report Summary 210-1 174-2 Fixed and Floating Head Pressure Comparison for Madison Ice Arena Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power July 1998 April, 2002 ENERGY CENTER OF WISCONSIN

P A P E R Fixed and Floating Head Pressure Comparison for Madison Ice Arena 174-2 July 1998 Prepared by Kyle A. Brownell Brownell Engineering 7010 Brianna Street Schofield, WI 54476 (715) 355-9426 Prepared for 455 Science Drive, Suite 200 Madison, WI 53711 Phone: (608) 238-4601 Fax: (608) 238-8733 www.ecw.org

Copyright 1998 Energy Center of Wisconsin All rights reserved This report was prepared as an account of work sponsored by the Energy Center of Wisconsin (ECW). Neither ECW, participants in ECW, the organization(s) listed herein, nor any person on behalf of any of the organizations mentioned herein: (a) makes any warranty, expressed or implied, with respect to the use of any information, apparatus, method, or process disclosed in this report or that such use may not infringe privately owned rights; or (b) assumes any liability with respect to the use of, or damages resulting from the use of, any information, apparatus, method, or process disclosed in this report. Project Manager Ruth Urban Energy Center of Wisconsin

Contents Introduction...1 Refrigeration System Head Pressure Control...3 Conclusions...7 References...8

Figures Figure 1 Figure 2 Figure 3 Schematic of the ice rink refrigeration system...2 System coefficient of performance...5 Fan and compressor power...6

Introduction A case study was performed on the refrigeration system serving the Madison Ice Arena which has 25,000 ft 2 (2323 m 2 ) of ice. The HCFC-22 based system, which was installed in the winter of 1996, consists of six semihermetic reciprocating compressors having a total capacity of 103 tons (355 kw). The shell-and-tube evaporator has two separate direct-expansion refrigerant circuits. A parallel rack of three compressors serves each refrigerant circuit. On the shell side of the evaporator, an ethylene glycol-water solution is cooled to the design leaving fluid temperature of 14 F (-10 C) prior to being pumped remotely for cooling two separate skating rinks. Heat is rejected from the refrigeration system by a two-circuit induced draft single speed evaporative condenser. As originally designed, the evaporative condenser fan cycles on and off as necessary to maintain the saturated condensing pressure between 220 and 250 psia (1517-1725 kpa). A schematic of the system is shown in Figure 1. 1

M a d i s o n I c e A r e n a Figure 1: Schematic of the ice rink refrigeration system Evaporative Condenser Receiver Receiver Evaporator Brine Supply Large Rink Return Small Rink Return Heat Exchanger Heat Exchanger Compressors Compressors 2

Refrigeration System Head Pressure Control The compressor discharge (or head) pressure is a function of the heat transfer rate in the condenser and the ambient wet bulb temperature (for evaporatively condensed systems). All else being the same, higher head pressures require additional compressor work and result in lower refrigeration system efficiency. However, a minimum pressure difference is required across the thermostatic expansion valve to ensure proper operation, so the head pressure is a controlled system parameter. The original method employed for head pressure control in this system is to cycle the evaporative condenser fan on and off as needed to maintain the head pressure (actually the saturated condensing pressure) between 220 and 250 psia (1517-1724 kpa) at all times during the year. During times when the fan operates, the heat rejection capacity of the evaporative condenser significantly increases and the condensing pressure (and discharge pressure) falls. When the fan cycles off, the heat rejection capacity of the condenser is diminished requiring the saturated condensing temperature (and pressure) to rise for rejecting heat to the ambient environment. Components on the refrigerant-side of the system are selected based on design refrigeration loads and design ambient conditions. For large capacity systems, ASHRAE (1993) recommends two or more compressors with multistage thermostats to control the compressor sequence of operation. Compressors should be selected with sufficient refrigeration capacity to pull-down (rapidly decrease the temperature of) the rink during system startup. The condenser selection and fan control should be based on: Maximum expected outdoor air wet-bulb temperature Ability to operate over a wide range in capacities Freeze protection for the water (for evaporative condensers and cooling towers) The easiest way to account for the varying outdoor operating temperatures is to maintain a controlled high head pressure in the condenser. The high head pressure ensures a large pressure differential is available to deliver the proper flow of refrigerant through the expansion valve. During the course of this study, it was found that ice arenas are commonly designed in this manner (Cox, D., Rink Tec International, Little Canada, MN, personal communication, 1998). One advantage of this control strategy is that it provides built-in freeze protection for the evaporative condenser by maintaining a high refrigerant saturated condensing temperature and thus a relatively high condenser return water temperature. Additionally, it ensures a high pressure difference across the expansion valve and therefore favorable control characteristics. Other large refrigeration systems, such as the systems for refrigerated warehouses, operate with a similar control strategy. Although a minimum head pressure is needed to maintain the required pressure drop across the expansion valve for refrigerant feed, it is easy to make the mistake of over-designing the system. Expansion valves are supplied with rated mass flows for given pressure drops. According to manufacturers data and studies done by Vinnicombe and Ibrahim (1991), expansion valves have an approximately 25 percent reserve capacity margin compared to data provided in the manufacturers catalog. To optimize system performance, it is necessary to determine the minimum allowable condenser pressure for a given evaporator pressure. This lower limit is determined by examining the minimum required expansion valve pressure drop as provided by the manufacturer. The reserve capacity of the expansion valve can be used as the system design margin of safety. A minor change in the head pressure control strategy to further float the head pressure can have a significant effect on refrigeration system performance. With floating head pressure control, the head pressure changes as a function of the ambient wet bulb temperature (for water cooled and evaporatively condensed systems). For the equipment installed in the ice arena, a minimum pressure difference across the expansion valve of 70 psi (483 3

M a d i s o n I c e A r e n a kpa) was required to ensure proper control. In this system, the evaporator pressure is, essentially, constant at approximately 40 psia (275 kpa) year-round. A conservative minimum head pressure for this system needed to provide reliable thermostatic expansion valve control is 155 psia (1070 kpa) which corresponds to a saturated condensing temperature of 55 F (12.8 C) for HCFC-22. This minimum head pressure provides a pressure drop of approximately 115 psi (793 kpa) across the expansion valve which is well above the minimum required pressure drop of 70 psi (483 kpa). The original control strategy maintained the head pressure between 220 and 250 psia, (1517-1724 kpa) providing far more pressure difference across that expansion valve than required. The control system at the Madison Ice arena was modified to allow for floating of the head pressure in accordance with the recommendations in Brownell s study of the system (1998). Once these control changes were implemented, additional data was taken to determine the specific operating impact on the system. Figure 2 depicts these results. The coefficient of performance is directly calculated from data taken on the brine side of the system and the refrigerant side of the system. The refrigerant side COP is used in this analysis to allow for comparison with previous work (Brownell, 1998). As evident in Figure 2, the system operates with a COP of approximately 2.25 when the head pressure is allowed to float. The COP decreases drastically to approximately 1.75 when the head pressure control is changed to a set point of between 220 and 250 psia. This is a decrease in system operating efficiency of approximately 22percent. The outside air wetbulb temperature was approximately 50 F during this experimentation. According to Brownell s study, the COP using floating and fixed head pressure at 50 F wetbulb temperature were predicted to be 2.15 and 1.65, respectively. This is a difference in operating efficiency of approximately 23 percent. When comparing the actual and predicted COP values, the difference was found to be approximately five percent, which is within experimental error. One perceived disadvantage in using floating head pressure is that the fan is constantly operating rather than cycling on and off. This constant operation translates directly into increased energy consumption for the fan. However, as shown in Figure 3, the increased energy costs are offset by the decrease in fan power. 4

H e a d P r e s s u r e C o n t r o l Figure 2: System Coefficient of Performance 2.8 2.5 COP REFRIGERANT COP DATA (GLYCOL) 2.3 2.0 1.8 1.5 1.3 1.0 0.8 0.5 0.3 0.0 0 5 10 15 20 25 30 35 40 TIME (Minutes) 5

M a d i s o n I c e A r e n a Figure 3: Fan and Compressor Power 80.0 70.0 Power fan Power compress ors 60.0 50.0 40.0 30.0 20.0 10.0 0.0-10.0 0 5 10 15 20 25 30 35 40 TIME (Minutes) The first part of the graph depicts the compressor and fan power required during floating head pressure while the point where the compressor power substantially increases and the fan power decreases is where the system was being operated using fixed head pressure. As indicated in the figure, the compressor power increases from 61 kw to approximately 75 kw while the fan power decreases from approximately 5.7 kw to an average of 2 kw. The additional fan power was accounted for in this analysis. 6

Conclusions The major finding in this study is that the operating cost of large direct-expansion refrigeration systems can be significantly reduced by a simple change in the control strategy for the condenser fan. Many systems are designed to maintain high condensing pressures. However, to improve system efficiency, the head pressure should be allowed to float with varying environmental conditions to a minimum value dependent upon the characteristics of the installed thermostatic expansion valves. The floating head control strategy would cause the fan to cycle on and off at only conditions of extremely low outside air temperatures so that a minimum pressure difference across the thermostatic expansion valve is maintained. For the ice arena system investigated, the additional fan power required is greatly exceeded by the reduction in power needed to operate the compressors. The overall annual cost savings for this system using floating head pressure control is predicted to be $9600 (Brownell, 1998). The control change required to realize these savings cost the Madison Ice Arena approximately $1000. This amounts to a payback period of less than two months. 7

References American Society of Heating, Refrigeration, and Air Conditioning Engineers. 1993. ASHRAE Handbook, Fundamentals. Atlanta, GA: ASHRAE. Brownell, K.A. 1998. Investigation of the Field Performance for Industrial Refrigeration Systems (174-1). Madison, WI: Energy Center of Wisconsin. Vinnicombe, G.A. and Ibrahim, G.A. 1991. The Performance of Refrigeration Expansion Devices. London, UK: Electricity Association Technology Ltd. 8